0% found this document useful (0 votes)
97 views

Beam Design

The document contains details of the beam layout and reinforcement for a building structure. It includes tables specifying the size, reinforcement, and stirrups for plinth beams, first floor beams, second floor beams, roof beams, and a stair roof beam. It also provides loading data and design parameters for interior beams, including maximum and minimum axial forces, shear forces, torsional moments, and bending moments.

Uploaded by

Arpan Saha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views

Beam Design

The document contains details of the beam layout and reinforcement for a building structure. It includes tables specifying the size, reinforcement, and stirrups for plinth beams, first floor beams, second floor beams, roof beams, and a stair roof beam. It also provides loading data and design parameters for interior beams, including maximum and minimum axial forces, shear forces, torsional moments, and bending moments.

Uploaded by

Arpan Saha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 21

1 2 3 3'

TB-1 TB-1 TB-1


B
TB-3
TB-2 TB-2 TB-2 TB-2

A
TB-1 TB-1 TB-1

Plinth Beam Layout (T.O.C-RL.-469.400m)

Beam
Beam Size Reinforcement Stirrups
Mkd.
B(mm) D(mm) Top Bottom
TB-1 300 600 4-T16 4-T16 2L-10T@150c/c
TB-2 400 600 4-T20 3-T20 2L-10T@200c/c
TB-3 250 400 3-T16 3-T16 2L-10T@150C/C

1B1 1B1 1B1

1B4

1B4 1B4 1
1 B
1 B 1 4
1 B 3 1B4
B
B 3 3
2 1
1 1 B
1B3 B 1B3
B 2
2 1 2
1 B
B 1B3 1B3 3
4

1B3 1B3
Y X
Z
Load 2055

1B1 1B1 1B1


1st Floor Beam Layout

Beam
Mkd. Beam Size Reinforcement Stirrups

B(mm) D(mm) Top Bottom


1B1 300 600 4-T20 4-T20 2L-10T@175 C/C
1B2 400 600 6-T25 6-T25 2L-10T@150 C/C
1B3 300 450 4-T20 4-T20 2L-10T@125 C/C
1B4 250 400 3-T16 3-T16 2L-10T@125 C/C
2B1 2B1 2B1

2B3 2B3
2B5 2
2
B 2 2 2 B
2 B B B 2
4 2 4 2
B
2B3 2B3 2

Y X
Z
Load 2055

2B1 2B1 2B1

2nd floor beam layout

Beam
Beam Size Reinforcement Stirrups
Mkd.
B(mm) D(mm) Top Bottom
2B1 300 600 4-T25 4-T20 2L-10T@150 c/c
2B2 400 600 4-T25 4-T25 2L-10T@150 c/c
2B3 300 450 3-T16 3-T16 2L-10T@150 c/c
2B4 400 600 3-T20 4-T25 2L-10T@200 c/c
2B5 250 400 3-T12 3-T16 2L-10T@200 c/c

RB1 RB1 RB1

R R RB4
B B
3 3
R R
B R B
2 B 2
RB3 R RB3
B 2
2
Y X
Z
Load 2055

RB1 RB1 RB1

Roof Beam layout

Beam
Mkd. Beam Size Reinforcement Stirrups

B(mm) D(mm) Top Bottom


RB1 300 600 3-T20 3-T16 2L-10T@175 C/C
RB2 400 600 4-T20 4-T25 2L-10T@200 C/C
RB3 300 500 3-T20 3-T20 2L-10T@200 C/C
RB4 250 400 3-T16 3-T16 2L-10T@175 C/C
SB1

SB1 SB2 SB1

YX
Z
Load 2055

SB1
Stair roof beam Layout

Beam
Beam Size Reinforcement Stirrups
Mkd.
B(mm) D(mm) Top Bottom
SB1 300 600 3-T16 3-T16 2L-10T@175 C/C
SB2 250 400 2-T12 2-T16 2L-10T@200 C/C
Design Of interior Beam : (As T Beam)

Loading Data:

Axial Shear Torsion Bending


Beam d Fx Fy Fz Mx My Mz
(m) (Mton) (Mton) (Mton) (MTon-m)(MTon-m) (MTon-m)
Max Fx 9 2027 0.0 2.5 6.2 0.0 0.2 0.0 7.9
Min Fx 6 2053 0.0 -4.9 7.6 0.0 -0.4 0.0 8.1
Max Fy 9 2036 0.0 -4.4 9.1 0.0 0.3 0.0 10.2
Min Fy 8 2036 6.6 -3.6 -9.5 0.0 -0.3 0.0 10.8
Max Fz 7 2064 0.0 -2.3 3.6 0.0 0.0 -0.1 2.7
Min Fz 10 2018 0.0 0.1 3.3 -0.1 0.1 0.1 1.6
Max Mx 9 2037 0.0 -4.5 7.8 0.0 0.4 0.0 8.7
Min Mx 6 2037 0.0 -4.8 7.7 0.0 -0.4 0.0 8.2
Max My 10 2018 0.0 0.1 3.3 -0.1 0.1 0.1 1.6
Min My 8 2051 6.6 -4.0 -8.2 0.0 -0.3 -0.1 9.4
Max Mz 5 2055 6.6 -4.4 -8.6 0.0 0.2 0.0 11.0
Min Mz 8 2036 3.3 -3.6 -0.6 0.0 -0.3 0.0 -5.6

Maximum Support Moment:Mu = 10.963 T-m = 79.29538 kip-ft


Maximumn Span Moment: Mu = 5.6 T-m = 40.77 kip-ft
Maximum shear Force : 9.1 T = 20.15999 kip

Parameters:
Concrete characteristic strength,fc' = 25 N/mm2 = 3625.95 psi

Reinforcement yield stress,fy = 420 N/mm2 = 60915.96 psi

λ for normal weight concrete = 1

Beam Size:
Width =bw= 300 mm = 11.8 in
Depth = D = 600 mm = 23.6 in
Clear cover = 35 mm = 1.4 in
Column Size:
Width= 450 mm = 17.7 in
Depth= 450 mm = 17.7 in

Span length of beam = 3.275 m = 10.74 ft


Tributory width = Sw = 3.66 m = 12.0 ft

Slab thickness = hslab 150 mm = 5.91 in

Longitudinal reinforcement Dia=d b = 19 mm = 0.75 in


Stirrups- Dia = dtie = 10 mm = 0.39 in

Effective depth =d= 545.5 mm = 21.5 in

Calculation:

Flange width = bf = bw + 2x Min( 8Xhslab, Sw/2,ln/8)

8 X hslab = 1200 mm = 47.24 in


Sw /2 = 1830 mm = 72.05 in
ln/8 = 353 mm = 13.90 in

bf = 1006 mm = 39.62 in

Equivalent concrete compressive depth=a = β1c

Where, β1 = 0.85

In Beam, compressive force = Tensile force, C=T

So, 0.85fc'xbxa = Asxfy

For, span moment ,b = bf= 39.62 in

For, Support moment =b= 11.8 in

So, for Span moment = a= 0.50 x As


For support moment =a= 1.67 x As

M u ≤ φ Mn

Where, φ = 0.9
Mn = As x fy x(d- a/2)

For Support moment


φMn = 54824.364 As X ( 21.5 - 1.67 x As / 2 )
So, 17.35624 = 21.5 As - 0.84 As2
As2 + -25.7 As + 20.74353 = 0
As = 0.83534 in 2
= 538.9281 mm2

For Span moment


φMn = 54824.364 As X ( 21.5 - 0.50 x As / 2 )

So, 8.922716 = 21.5 As - 0.25 As2


As2 + -86.1 As + 35.76917 = 0
As = 0.42 in2 = 269.3485 mm2

Minimum Reinforcement:

As = 3x√fc'/fyxbwxd = 485.3076 mm2 = 0.75 in2

As = 200/fyxbwxd = 537.2976 mm2 = 0.83 in2

So, Minimum reinforcement,As = 537.2976 mm2 = 0.83 in2

Provided, As at support Top = 538.9281 mm2 = 0.84 in2

Provided, As at span bottom = 537.2976 mm2 = 0.83 in2

Shear Design:

Shear strength, φVn ≥ Vu

Where, φ= 0.75
Vn = Vc + Vs
Vu = 20.16 kips

Vc = 2√fc'xbw x d = 30.55 kips

φVc = = 22.91 kips

Shear reinforcement not required

Cross sectional dimension checking:

Vu≤φ(Vc +8√fc' xbw x d) = = 114.6 kips

>Vu,Sectional dimension is ok
Shear Reinforcement:

φVs ≥ Vu - φVc

Where, Vs = Av x fy x d/s

φVs = 0.00 kips

Av = 157.08 mm2 = 0.24 in2


(For 10 dia 2-legged stirrups)

s= NA in

so, Maximum stirrup spacing = 10.7 in

Provide stirrup 10 dia-2L @ 8 inch c/c =2-L-10 Dia @250 C/c



Design Of interior Beam : (As T Beam)

Loading Data:

Axial Shear Torsion Bending


Beam d Fx Fy Fz Mx My Mz
(m) (Mton) (Mton) (Mton) (MTon-m)(MTon-m) (MTon-m)
Max Fx 168 2029 0.0 -0.2 -0.7 0.0 0.3 0.1 -7.4
Min Fx 2 2037 0.0 -10.9 2.5 0.0 0.0 0.0 4.2
Max Fy 3 2053 0.0 -5.2 13.5 0.1 1.1 -0.2 19.2
Min Fy 167 2051 4.4 -5.2 -12.4 0.0 -0.8 -0.1 18.5
Max Fz 3 2053 0.0 -5.2 13.5 0.1 1.1 -0.2 19.2
Min Fz 4 2064 0.0 -2.1 6.4 0.0 -0.3 0.1 2.8
Max Mx 3 2037 0.0 -5.8 12.6 0.0 1.4 0.0 14.4
Min Mx 4 2002 0.0 -1.0 12.5 0.0 -1.3 0.0 14.1
Max My 168 2053 4.4 -2.8 -9.2 0.1 0.6 0.1 6.7
Min My 3 2053 0.0 -5.2 13.5 0.1 1.1 -0.2 19.2
Max Mz 3 2018 0.0 -3.4 13.4 0.0 1.0 -0.1 19.7
Min Mz 4 2051 2.9 -2.8 2.9 0.0 -0.9 -0.1 -12.0

Maximum Support Moment:Mu = 19.738 T-m = 142.765 kip-ft


Maximumn Span Moment: Mu = 12.0 T-m = 86.98 kip-ft
Maximum shear Force : 13.5 T = 29.6438 kip

Parameters:
Concrete characteristic strength,fc' = 25 N/mm2 = 3625.95 psi

Reinforcement yield stress,fy = 420 N/mm2 = 60915.96 psi

λ for normal weight concrete = 1

Beam Size:
Width =bw= 400 mm = 15.7 in
Depth = D = 600 mm = 23.6 in
Clear cover = 35 mm = 1.4 in
Column Size:
Width= 450 mm = 17.7 in
Depth= 450 mm = 17.7 in

Span length of beam = 3.275 m = 10.74 ft


Tributory width = Sw = 3.66 m = 12.0 ft

Slab thickness = hslab 150 mm = 5.91 in

Longitudinal reinforcement Dia=d b = 19 mm = 0.75 in


Stirrups- Dia = dtie = 10 mm = 0.39 in

Effective depth =d= 545.5 mm = 21.5 in

Calculation:

Flange width = bf = bw + 2x Min( 8Xhslab, Sw/2,ln/8)

8 X hslab = 1200 mm = 47.24 in


Sw /2 = 1830 mm = 72.05 in
ln/8 = 353 mm = 13.90 in

bf = 1106 mm = 43.55 in

Equivalent concrete compressive depth=a = β1c

Where, β1 = 0.85

In Beam, compressive force = Tensile force, C=T

So, 0.85fc'xbxa = Asxfy

For, span moment ,b = bf= 43.55 in

For, Support moment =b= 15.7 in

So, for Span moment = a= 0.45 x As


For support moment =a= 1.26 x As

M u ≤ φ Mn

Where, φ = 0.9
Mn = As x fy x(d- a/2)

For Support moment


φMn = 54824.364 As X ( 21.5 - 1.26 x As / 2 )
So, 31.24851 = 21.5 As - 0.63 As2
As2 + -34.2 As + 49.79608 = 0
As = 1.522773 in 2
= 982.4321 mm2

For Span moment


φMn = 54824.364 As X ( 21.5 - 0.45 x As / 2 )

So, 19.03914 = 21.5 As - 0.23 As2


As2 + -94.6 As + 83.90861 = 0
As = 0.89 in2 = 577.404 mm2

Minimum Reinforcement:

As = 3x√fc'/fyxbwxd = 647.0768 mm2 = 1.00 in2

As = 200/fyxbwxd = 716.3968 mm2 = 1.11 in2

So, Minimum reinforcement,As = 716.3968 mm2 = 1.11 in2

Provided, As at support Top = 982.4321 mm2 = 1.52 in2

Provided, As at span bottom = 716.3968 mm2 = 1.11 in2

Shear Design:

Shear strength, φVn ≥ Vu

Where, φ= 0.75
Vn = Vc + Vs
Vu = 29.64 kips

Vc = 2√fc'xbw x d = 40.73 kips

φVc = = 30.55 kips

Shear reinforcement not required

Cross sectional dimension checking:

Vu≤φ(Vc +8√fc' xbw x d) = = 152.7 kips

>Vu,Sectional dimension is ok
Shear Reinforcement:

φVs ≥ Vu - φVc

Where, Vs = Av x fy x d/s

φVs = 0.00 kips

Av = 157.08 mm2 = 0.24 in2


(For 10 dia 2-legged stirrups)

s= NA in

so, Maximum stirrup spacing = 10.7 in

Provide stirrup 10 dia-2L @ 8 inch c/c =2-L-10 Dia @250 C/c



Design Of interior Beam : (As T Beam)

Loading Data:

Axial Shear Torsion Bending


Beam d Fx Fy Fz Mx My Mz
(m) (Mton) (Mton) (Mton) (MTon-m)(MTon-m) (MTon-m)
Max Fx 41 2050 0.0 1.2 7.7 0.0 0.7 0.0 7.4
Min Fx 43 2016 0.0 -1.6 13.7 0.0 -0.6 0.0 15.8
Max Fy 39 2037 0.0 0.4 17.8 0.0 -0.7 -0.1 17.8
Min Fy 114 2002 0.8 -0.3 -21.3 0.0 -0.7 0.0 23.6
Max Fz 114 2030 0.0 -1.2 -10.6 0.2 -0.1 0.1 5.2
Min Fz 114 2052 0.0 0.1 -17.1 -0.2 -0.5 -0.1 8.1
Max Mx 41 2002 0.0 0.1 6.6 0.0 0.8 0.0 5.7
Min Mx 44 2002 0.0 -0.7 6.3 0.0 -0.9 0.1 5.4
Max My 39 2028 0.0 -0.9 10.4 -0.1 -0.2 0.3 9.7
Min My 39 2053 0.0 -0.5 16.2 0.2 -0.5 -0.4 15.9
Max Mz 114 2002 0.8 -0.3 -21.3 0.0 -0.7 0.0 23.6
Min Mz 111 2002 0.0 -0.3 -2.6 0.0 -0.7 0.0 -16.0

Maximum Support Moment:Mu = 23.635 T-m = 170.952 kip-ft


Maximumn Span Moment: Mu = 16.0 T-m = 115.51 kip-ft
Maximum shear Force : 17.8 T = 39.121 kip

Parameters:
Concrete characteristic strength,fc' = 25 N/mm2 = 3625.95 psi

Reinforcement yield stress,fy = 420 N/mm2 = 60915.96 psi

λ for normal weight concrete = 1

Beam Size:
Width =bw= 300 mm = 11.8 in
Depth = D = 600 mm = 23.6 in
Clear cover = 35 mm = 1.4 in
Column Size:
Width= 450 mm = 17.7 in
Depth= 450 mm = 17.7 in

Span length of beam = 3.275 m = 10.74 ft


Tributory width = Sw = 3.66 m = 12.0 ft

Slab thickness = hslab 150 mm = 5.91 in

Longitudinal reinforcement Dia=d b = 19 mm = 0.75 in


Stirrups- Dia = dtie = 10 mm = 0.39 in

Effective depth =d= 545.5 mm = 21.5 in

Calculation:

Flange width = bf = bw + 2x Min( 8Xhslab, Sw/2,ln/8)

8 X hslab = 1200 mm = 47.24 in


Sw /2 = 1830 mm = 72.05 in
ln/8 = 353 mm = 13.90 in

bf = 1006 mm = 39.62 in

Equivalent concrete compressive depth=a = β1c

Where, β1 = 0.85

In Beam, compressive force = Tensile force, C=T

So, 0.85fc'xbxa = Asxfy

For, span moment ,b = bf= 39.62 in

For, Support moment =b= 11.8 in

So, for Span moment = a= 0.50 x As


For support moment =a= 1.67 x As

M u ≤ φ Mn

Where, φ = 0.9
Mn = As x fy x(d- a/2)

For Support moment


φMn = 54824.364 As X ( 21.5 - 1.67 x As / 2 )
So, 37.4181 = 21.5 As - 0.84 As2
As2 + -25.7 As + 44.72073 = 0
As = 1.879987 in 2
= 1212.892 mm2

For Span moment


φMn = 54824.364 As X ( 21.5 - 0.50 x As / 2 )

So, 25.28314 = 21.5 As - 0.25 As2


As2 + -86.1 As + 101.3545 = 0
As = 1.19 in2 = 770.1967 mm2

Minimum Reinforcement:

As = 3x√fc'/fyxbwxd = 485.3076 mm2 = 0.75 in2

As = 200/fyxbwxd = 537.2976 mm2 = 0.83 in2

So, Minimum reinforcement,As = 537.2976 mm2 = 0.83 in2

Provided, As at support Top = 1212.892 mm2 = 1.88 in2

Provided, As at span bottom = 770.1967 mm2 = 1.19 in2

Shear Design:

Shear strength, φVn ≥ Vu

Where, φ= 0.75
Vn = Vc + Vs
Vu = 39.12 kips

Vc = 2√fc'xbw x d = 30.55 kips

φVc = = 22.91 kips

Shear reinforcement required

Cross sectional dimension checking:

Vu≤φ(Vc +8√fc' xbw x d) = = 114.6 kips

>Vu,Sectional dimension is ok
Shear Reinforcement:

φVs ≥ Vu - φVc

Where, Vs = Av x fy x d/s

φVs = 16.21 kips

Av = 157.08 mm2 = 0.24 in2


(For 10 dia 2-legged stirrups)

s= 14.738 in

so, Maximum stirrup spacing = 10.7 in

Provide stirrup 10 dia-2L @ 8 inch c/c =2-L-10 Dia @250 C/c


Max Fx 41 2050 0 1.192 7.672 -0.019 0.674
Min Fx 43 2016 0 -1.582 13.693 0.007 -0.604
Max Fy 39 2037 0 0.357 17.75 0.022 -0.651
Min Fy 114 2002 0.75 -0.31 -21.326 0.017 -0.651
Max Fz 114 2030 0 -1.225 -10.609 0.197 -0.149
Min Fz 114 2052 0 0.11 -17.074 -0.199 -0.538
Max Mx 41 2002 0 0.082 6.574 -0.008 0.811
Min Mx 44 2002 0 -0.652 6.336 -0.036 -0.9
Max My 39 2028 0 -0.927 10.398 -0.147 -0.23
Min My 39 2053 0 -0.522 16.184 0.161 -0.462
Max Mz 114 2002 0.75 -0.31 -21.326 0.017 -0.651
Min Mz 111 2002 0 -0.304 -2.569 0.004 -0.651

0.028 7.434
-0.048 15.75
-0.051 17.786
0.034 23.635
0.103 5.227
-0.071 8.099
0.008 5.743
0.058 5.374
0.323 9.696
-0.351 15.854
0.034 23.635
0.009 -15.97

You might also like