Numerical Analysis of Water Temperature Distribution in The Tank of ASHPWH With A Cylindrical Condenser
Numerical Analysis of Water Temperature Distribution in The Tank of ASHPWH With A Cylindrical Condenser
ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency, Vol. IV-9-1
Abstract: Air source heat pump water heaters There are three popular types of residential
(ASHPWH) are becoming increasingly popular for water heater used in China market: electric resistance,
saving energy, protecting the environment and security direct gas fired and solar water heater. They have
purposes. The water temperature distribution in the tank their own advantages and disadvantages. For example,
is an important parameter for an ASHPWH. This paper energy efficiency of electric resistance water heater is
presented a mathematic model for a cylindrical water low. Gas fired water heater has safety incipient fault.
tank with a cylindrical condenser as its heat source. The Solar water heater is mainly confined by terrene,
computational fluid dynamics (CFD) software package, climate, building level[1].
FLUENT, was used to study hot water temperature ASHPWH composed of heat pump circulation
distribution in the tank of the ASHPWH. In addition, the system and water tank, is a type of heater utilizing air
effects of tank dimension and the type of condenser coil as heat source and its structure is shown as Fig.1[2].It
on water temperature distribution were discussed. The makes use of refrigerant in evaporator absorbing the
work of this paper could be used for the optimization of air heat, and the condenser is directly inserted into the
tank and condenser coil designs. tank for heating water. Its heating coefficient is 3 to 4
Key words: air source heat pump water heater; water times greater than conventional electrical resistance
temperature distribution; numerical analysis; tank heater’s. The condenser coil water heating can
dimension; condenser coil achieve water-electricity separation which makes it
good electrical security. Therefore, ASHPWH has
NOMENCLATURE such advantages as pollution-free, high- efficiency,
D1 diameter of water tank energy saving, safe-reliability and perfect self-control,
H height of water tank etc. The common design is to insert the condenser
D2 diameter of condenser coil coil of ASHPWH into the water tank. This design
L length of condenser coil could be less expensive than others and more
TC condenser coil temperature efficient because of the elimination of the water
T water temperature circulating pump and a heat exchange. Comparing
t time with general air conditioning, it is in dynamic
P pressure environment. Evaporating pressure, condensing
r
u velocity vector pressure and heating capacity increase with hot water
temperature rising. For using the water heater in daily
Greek Symbols life, hot water is drawn off the top of the water tank
ν kinematic viscosity and replaced by cold water entering at the bottom.
ρ density When the outlet temperature is constant, if the
β thermal expansion coefficient longitudinal temperature difference in a water tank
gives rise , the average hot water temperature will
1. INTRODUCTION reduce, the value of COP will increase. Therefore,
Proceedings of the Sixth International Conference for Enhanced Building Operations, Shenzhen, China, November 6 - 9, 2006
ESL-IC-06-11-118
ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency, Vol. IV-9-1
according to the hot water temperature distribution, To simplify the issue, the model was assumed as
design the rational water tank and the type of follows:
condenser coils, and thus greatly increase the heating (1)The water tank sidewall was assumed
coefficient [3]. adiabatic.
(2)The condenser coil immersed in tank was
cylindrical.
(3)The condenser coil was regarded as the fixed
3 temperature wall boundary, the temperature was the
average value of results of testing.
(4)The water flow was turbulence[4],[5].
4 (5)Natural convection flow was modeled with
2
Boussinesq approximation[2].
1 For many natural-convection flows, you can get
faster convergence with the Boussinesq model than
Fig1. Schematic diagram of ASHPWH you can get by setting up the problem with fluid
1—Evaporator 2—Compressor 3—Condenser density as a function of temperature. This model
4—Capillary tube treats density as a constant value in all solved
In this paper, the impact that the tank dimension equations, except for the buoyancy term in the
and the type of condenser coil of an ASHPWH with momentum equation[6]:
cylindrical condenser on the water temperature
(ρ − ρ 0 )g ≈ − ρ 0 β (T − T0 )g (1)
longitudinal stratification was investigated by using
FLUENT computational fluid dynamics software
where ρ 0 is the (constant) density of the flow,
package.
Proceedings of the Sixth International Conference for Enhanced Building Operations, Shenzhen, China, November 6 - 9, 2006
ESL-IC-06-11-118
ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency, Vol. IV-9-1
Proceedings of the Sixth International Conference for Enhanced Building Operations, Shenzhen, China, November 6 - 9, 2006
ESL-IC-06-11-118
ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency, Vol. IV-9-1
345.00
Average
Water temperature (K)
340.00
Maximum
335.00
Minimum
330.00
325.00
320.00
315.00
310.00
328 333 338 343 348 353
Condenser temperature(K)
Fig.7 Results of condition Ⅲ
Fig.5 Results of condition Ⅰ
Average
326.00 Maximum
Water temperature (K)
Minimum
324.00
322.00
320.00
318.00
316.00 (b)
0.6 0.8 1.0 1.2 1.4
Fig.8 The temperature contour of flow along
Length of condenser(m)
asymmetric cutplane; (a) The ratio of
Fig.6 Results of condition Ⅱ tank’s diameter to height is 0.465. (b)
The ratio of tank’s diameter to height is
3.3.3 Effects of the Tank Dimension on Water 0.118.
Temperature Distribution Fig.7, with the ratio of the tank’s diameter to height
With the condenser temperature, heating time increasing, the average temperature, the maximum
and the tank volume fixed, the height of tank was temperature and the minimum temperature increased
gradually up to 2.5m from 0.5m, and its diameter firstly, then reduced, the maximum average
reduced to 0.294m from 0.658m gradually. temperature was 322.6K at 0.465 ratio of the tank’s
Preliminary analysis showed that water temperature diameter to height. The maximum temperature
changed little when the length of condenser coil was difference in the tank altitude direction was up to
greater than 2/5 of the tank height. So the length of 9.4K from 1.5K, the temperature stratification was
condenser coil was taken as 2/3 height of the tank. In remarkable. Fig.8 (a), (b) gave the water temperature
Proceedings of the Sixth International Conference for Enhanced Building Operations, Shenzhen, China, November 6 - 9, 2006
ESL-IC-06-11-118
ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency, Vol. IV-9-1
distribution in two tanks whose ratio of diameter to water temperature changed little. With the ratio of the
height were 0.465 and 0.118. Because of the increase tank’s diameter to height increasing, the average
of the tank height, the water velocity was reduced, temperature, the maximum temperature and the
which eliminated water natural convection, minimum temperature increased firstly, then reduced,
aggravated the temperature uniformity. the maximum average temperature was 322.6K at
3.3.4 Effects of Heating Time on Water Temperature 0.465 ratio of the tank diameter to its height. The
Distribution water tank was optimized according to the above
In Fig.7, other conditions were constant, the influencing factors.
maximum average temperature was 322.6K at 0.465
ratio of the tank diameter to height. Although the REFERENCES
average temperature was the maximum value in this [1] Qinghai LUO, Guangfa TANG, Guangcai GONG.
tank, the temperature difference was not the Investigation on a novel thermoelectric heat pump
minimum value. Therefore, the heating time was water heater[J]. Journal of Hunan
extended to observe the variation of temperature University(Natural Sciences), 2005, 32(4):
difference. Fig.8 illustrated the temperature 34-38.(In Chinese)
difference in the tank altitude direction changed [2] Zhiming GAO,Vince C.MEI. CFD solution and
unobviously with the increase of heating time. The experimental testing of buoyancy-driven
temperature grew 1K after 1.5h of heating, and then convection caused by condenser immersed in a
there wasn’t remarkable change. water tank of HPWH[C]. American Society of
327.00 Mechanical Engineers, Advanced Energy Systems
326.00 Division (Publication) AES, v 43, Proceedings of
Water temperature (K)
Proceedings of the Sixth International Conference for Enhanced Building Operations, Shenzhen, China, November 6 - 9, 2006
ESL-IC-06-11-118
ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency, Vol. IV-9-1
Chinese) inside a horizontal freezer[J]. Journal of Tianjin
[9] Tianji CHEN, Yingying SUN, Haofeng YAN. A University of Commerce. 1996, No.3:6-13.(In
numerical study of the temperature distribution Chinese)
Proceedings of the Sixth International Conference for Enhanced Building Operations, Shenzhen, China, November 6 - 9, 2006