0% found this document useful (0 votes)
378 views

Formulir Technical Analysis Report: Nomor Dokumen Tanggal Efektif Revisi Halaman

The technical analysis report summarizes an issue with a Hitachi excavator's hydraulic system. Specifically, the EHC valve for bucket roll-in was stuck, preventing that function. Testing found the valve itself was stuck and rusty. To resolve the problem, the report recommends replacing the faulty EHC valve with a new one and checking the hydraulic oil sample. The required part is listed along with its estimated replacement cost.

Uploaded by

Zidan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
378 views

Formulir Technical Analysis Report: Nomor Dokumen Tanggal Efektif Revisi Halaman

The technical analysis report summarizes an issue with a Hitachi excavator's hydraulic system. Specifically, the EHC valve for bucket roll-in was stuck, preventing that function. Testing found the valve itself was stuck and rusty. To resolve the problem, the report recommends replacing the faulty EHC valve with a new one and checking the hydraulic oil sample. The required part is listed along with its estimated replacement cost.

Uploaded by

Zidan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

0

FORMULIR Nomor Dokumen CORP/PLANT/F-0007


Tanggal Efektif 10-Aug-20
TECHNICAL ANALYSIS REPORT Revisi 0
Halaman 1 dari 1

WO :
Fax : 021-29661511
To : Plant Departement Head Office TAR No. : .…/ TAR/052C/2020
Address : Jakarta Date : 1-May-21
Attn : Damanhuri
Telp : 021-75924414 Delivery Date : 1-May-21
CC : Plant HO
Model Make : Model Type : Kilometers :
HITACHI EX3600-6
Serial No. : Unit Code. : Hour meters : 48894.5 H
EX-8003
Component : Description : Trouble Date : 6-Mar-21
HYDRAULIC SYSTEM EHC VALVE

Problem/Issue :
Bucket roll in is not working
Reason of Failure :
Stuck EHC valve bucket roll in position (Power from ELU OK, Solenoid OK), we remove the EHC Solenoid, and found stuck valve,
rusty is the problem.
Suggestion and Action taken:
1. Check the oil hydraulic sample
2.
j Replace EHC Valve with the new one
Component List :
Estimasi Cost :
Parts Number Description QTY
9242460 VALVE SOLENOID 1

TOTAL
PPN 10%
Grand Total

Picture :

Reporting by : Aknowledge by : Data base by :