Smart Energy & Power Quality Solutions

THE JANITZA
CURRENT TRANSFORMER RANGE
Smart Energy
Smart Energy
& Power
& Quality
Power Quality
Solutions
Solutions

UMG 96 RM PN

THE LINK BETWEEN HEAVY


CURRENT AND MEASUREMENT
TECHNOLOGY

2
Smart Energy & Power Quality Solutions

The right current transformer


for every application

Anyone wanting to record energy consumption,


must measure currents. This is done by using
a  current transformer to measure the magnetic
field created by the current. In principle, the current
transformer is similar to a power transformer.
The primary circuit is formed by the line to be
measured, the connection to the measurement
device forms the secondary circuit. As a result,
on the one hand there is a  galvanic separation
between the measurement device and the current
circuit to be measured and on the other hand, the
size of the current can be transformed down by a
defined ratio to a size suitable for the measurement
device:

For example, a high-power 320 Amp line can


be reduced by means of a 500:5 transformer to
more convenient 3.2 Amps. At the same time,
the measurement equipment is protected by the
so-called saturation effect in the event of a fault,
e.g. with a short-circuit: This phenomenon means
that the magnetisation of a material through a
magnetic field only rises until it reaches saturation
point. The current in the secondary circuit is
thus automatically limited through the physical
characteristics of the current transformer.

The appropriate combination of measurement


device and transformer is critical for the quality
and accuracy of a measurement: As with
measurement devices, there are permissible
nominal currents and accuracy classes with
transformers too, the knowledge of which is
essential for correct measurement.

3
Smart Energy & Power Quality Solutions

Current transformers;
Safe – robust – precise
The ideal expansion for energy measurement devices

Janitza electronics® has a broad spectrum of different current cable split core current transformers. Low-power transformers
transformers, ranging from moulded case current transformers, with mA outputs and Rogowski coils including converter with
summation transformers to differential current transformers and 1 A output complete the product range.

Differential
current
transformers

Moulded case
Split-core current
current
transformers
transformers

Cable split core


current
transformers

4
Smart Energy & Power Quality Solutions

Flexible and easy to install

DIN rail current


transformers

Summation
current Rogowski coils
transformers

Three-phase
current
transformers

5
Smart Energy & Power Quality Solutions

Current transformers
for every area of application
The ideal expansion for energy measurement devices

Janitza electronics® has a broad spectrum of different current and core balance transformers. Low-power transformers with
transformers, ranging from plug-on current transformers, sum- mA outputs and Rogowski coils including converter with 1 A
mation current transformers to residual current transformers output complete the product range.

10 Moulded case current transformer (for billing purposes)

13 Summation current transformer

14 Cable split core current transformer

17 Three-phase current transformer

18 DIN rail current transformer

19 Compact current transformer

20 Flexible current transformer (Rogowski coils)

6
Smart Energy & Power Quality Solutions

Axim reptiatas modit aliquid quatior enditatium nimi, et quas disit quae. Cae nobit debis dolore nemolesequi quibusc iissitiis
dolorate di volum lia estrum que dolorerum laborum quis eius accus autecto verum adi simus est, ullabo. Ihiliquas am aliquodi
sit quo con rempe nihicabo. Ut ideserc iaturib usdaesto bla ven- atae sequunt fugit offic toreper ibustota susamus et ant fugiti

21 Split-core current transformer for the UMG 20CM

23 6-fold DIN rail current transformer

25 Feedthrough residual current transformer

27 Split-core residual current transformer

29 Differential current transformer type B+

32 Accessories

7
Smart Energy & Power Quality Solutions

8
Smart Energy & Power Quality Solutions

Features and advantages of


Janitza current transformers
Advantages at a glance

 Ideally suited for energy and power


quality measurement devices

 H
 igh measurement accuracy up to class 0.2

  easurement of harmonics up to
M
the 50th. harmonic

 Long service life

 High overload capability

 Unbreakable plastic housing

  ariable, space-saving and particularly


V
rapid installation

 Ideal for use in very compact installation


spaces

  igh level of safety thanks to galvanic


H
separation between measurement circuit
and measurement device

 Large selection for different parameters

  ow power losses even with high


L
primary currents

 Safe connection technology

  igh interference resistance to external


H
magnetic fields

9
Smart Energy & Power Quality Solutions

Moulded case
current transformer
Class 1 and 0.5 to / 5 A

Moulded case current transformers are used if high currents are shock and vibration resistance with mechanical loading
to be recorded and further processed. The line to be measured (IEC 68). This is the most common and cost-effective form of
(conductor rail or wire) is fed through the window opening and current transformer. However, the primary conductor must be
forms the primary circuit for the plug-on current transformer. disconnected during installation. This form of transformer is
Moulded case current transformers are predominantly used therefore most commonly used in new system installations.
for mounting on conductor rails. Through additional potting
it is possible to achieve droplet-tightness, as well as greater

10
Smart Energy & Power Quality Solutions

Versatility & increased safety

Main features

Increased safety Secondary connection feed


 Both halves of the housing overlap rather than butting up  Feeding of the secondary connection to the connection
against one another terminals through the rectangular opening in the front and
 Burst-resistant plastic housing made from polyamide rear sides
 Non-combustible per UL 94 VO and self-extinguishing  During installation, e.g. behind the safety strip, the
secondary connection is implemented by means of cable
Protective caps for primary rail fastening screws lugs through the side slots
 Screw-in pins for the primary rail terminals can be insulated
by means of protective caps, available as an option Expanded secondary terminal covering
 Safeguard to prevent accidental contact  In addition to the normal terminal covering, extra protective
hoods are available
 Locking of the front and rear feed to the secondary
terminals

General mechanical properties

 Nominal frequency 50 – 60 Hz
 Insulation class E (other classes on request)
 Thermal rated short-term current Ith = 60 x IN/1s Current transformer 50 / 5 A, Imax = 50 A
 Rated surge current Idyn = 2.5 x Ith, min.,
however 100 kA with all plug-on current transformers
 Highest voltage for operating equipment Um = 0.72 kV
 Rated insulation level (test voltage) 4 kV / 1 min
(per EN 61869-2)
 Over-current limit factor FS5 or FS10
 Harmonics current up to 50th harmonic

Equivalent to a transformer 100 / 5 A, Imax = 50 A

11
Smart Energy & Power Quality Solutions

Moulded case current trans-


former for billing purposes

Moulded case current transformer for billing purposes

The applicable regulations for kWh measurement devices can  Transformation ratio: 50/5 A to 2500/5 A
be fulfilled with these tariff current transformers.  Rated power: 1.25 to 5 VA
 Precision class: 0.5 / 0.2S
All tariff current transformers are equipped with an integrated Round
 conductor: Ø
 23 to 85 mm
lockable terminal cover, produced from polycarbonate. The
 Width: 60 to 129 mm
current transformers are supplied with a fastening tool, for
 Insulation class E
mounting on rails or cables. The transformers can be optionally
ordered with clips, which enable mounting on a DIN rail.

12
Smart Energy & Power Quality Solutions

Summation
current transformer

If the current measurement is carried out with two or more current


transformers (e.g. two transformers) and if the total consumption
is to be calculated, the secondary signals from the individual
current transformers can be summed with the help of summation
current transformers. This enables the total consumption to be
recorded with just one measurement instrument. The output of the
summation current transformer is a standardised measurement
signal. Alongside the addition of the input currents, the total is also
divided by the number of summands (number of inputs).

Summation current transformer Summation current transformer


for plug-on and split transformers for core current transformers

 Summation of the secondary currents from multiple main  High measurement accuracy
transformers  Simple spring-clamp technology
 Access to the measurement possible for a measurement  Perfect interaction with the KUW series core current
instrument transformers
 There is a standardised measurement signal available at the output  Rated power: 0.2 VA
 Distinction for similar and dissimilar main transformers  Precision class: 1
 Burst-resistant plastic housing made from ABS, IP40  Secondary current: 1 A
 Rated power: 10 to 15 VA  Dimensions: 80 x 30 x 60 mm and
 Precision class: 0.5 and 1 80 x 55 x 60 mm (H x W x D)
 Secondary current: 1 A and 5 A
 Maximum conductor cross-section: 2.5 Ø solid, 1.5 Ø flexible
 Dimensions: 115 x 45 x 73 mm (W x H x D)

13
Smart Energy & Power Quality Solutions

Cable split core


for retrofitting existing systems

Compact, splitting current transformers for retrofitting

 Ideal for retrofitting as the primary current circuit need not  Transformation ratio: 60/1 A to 1000/5 A
be disconnected  Rated power: 0.2 to 0.5 VA
 Ideally suited for energy and power quality measurement  Precision class: 0.5, 1 and 3
devices  Round conductor: Ø
 18 / 28 / 42 or 42 x 84 mm
 Ideal for use in very compact installation spaces  Dimensions: 48 x 50.4 to 66.2 x 139 mm
 Especially fast installation  Current transformer per IEC 61869-2
 Including colour-coded secondary lines
 Fastening of the transformer with the two UV-resistant
cable ties provided

14
Smart Energy & Power Quality Solutions

Clear rating plate


with technical details

Double insulated
color coded leads

Special lugs for cable


mounting with tyraps

Suitable for insulated


conductor

Split-core Build in spring for


continuous pressure
on the cores

Easy closing by Easy mountable


click system in narrow situations
by removable hinge

15
Smart Energy & Power Quality Solutions

Cable split core


current transformer

Compact, splitting and safe

 Core can be split at the push of a button  Transformation ratio: 250/1.5 A to 1250/7,5 A
 Ideal for retrospective installation in existing systems  Rated power: 1.5 to 5 VA
 Simple and secure attachment - current transformer audibly  Precision class: 0.5 and 1
latches  Conductor feed-through: 55 x 85 or 85 x 125 mm
 Can be securely fastened in place through numerous  Dimensions: 125 x 158 and 155 x 198 mm
clamping screws  Applied technical standards:
DIN EN 61869, part 1 + 2; IEC 61010-2;
Low voltage directive 2014/35/EU

16
Smart Energy & Power Quality Solutions

Three-phase current
transformer

Cost-effective, space-saving and simple to install

 Transformation ratio: 50/5 A to 150/5 A


 Simple DIN rail mounting
 Rated power: 1 to 2.5 VA
 Low costs due to reduced wiring work
 Precision class: 0.5 and 1
 Lower spatial requirements thanks to compact construction
 Round conductor: Ø 13.5 mm per phase
 For connection to current measuring systems with 5 A input
 Dimensions: 105 x 90 x 54 mm
 Applied technical standards:
DIN EN 61869, part 1 + 2; IEC 61010-2;
Low voltage directive 2014/35/EU

17
Smart Energy & Power Quality Solutions

DIN rail current transformer


with voltage tap-off & back-up fuse

Circuit diagram

Space-saving and time-saving

 Space-saving and easily installed rail clamps with integrated  Transformation ratio: 35/1 A and 64/1 A
current transformer and fused voltage tap-off  Rated power: 0.2 VA
 Precise current and voltage measurement  Precision class: 0.5 and 1
 High short-circuit resistance 70 kA to 400 V / 50 Hz  Round conductor: 1.5 – 16 mm2
 Prevention of connection errors  Dimensions: 72 x 32 x 96 mm
 High degree of reliability due to fewer connections  KEMA-KEUR certified
 Specially developed for energy measurement up to 64 A

18
Smart Energy & Power Quality Solutions

Compact current transformer

Suitable for operating and residual current

 Transformation ratio: 35/1 A, 64/1 A, 700/1 A (RCM)


 Connection of multiple transformers from this series
 Rated power: 0.2 VA
possible (Lego-transformers)
 Precision class: 1
 Space-saving installation directly above circuit breakers
 Round conductor: 7.5 mm
 Installation also possible in the tightest of spaces
 Dimensions: 46 x 27 x 23 mm
 Particularly well suited to digital measurement devices
 Current transformer per IEC 61869-2
 Primary window can be used for insulated cable Ø 7.5 mm
 For use on a 3-phase disconnector with a phase spacing
of 17.5 mm
 DIN rail mounting (35 mm) via rail clamps (optional)

19
Smart Energy & Power Quality Solutions

Rogowski coils
and Measurement transducer

The operation of the Rogowski coils as per the


technical data mentioned herein can only be
assured in combination with Janitza measuring
transducer “RogoTrans”.

Flexible and precise Rogowski current transformer Measurement transducer for Rogowski current transformer

 Frequency bandwidth of the Rogowski coil 50/60 Hz,  Measurement transducer for Rogowski current transformer
up to 700 kHz without load (no-load operation) (item no. 15.03.609, 15.03.610, 15.03.611)
 Accuracy per class 0.5, in accordance with IEC 61869  Standardised output signal 0 to 1 A
 Operating temperature: -40°C to +80°C  For measuring alternating currents
 Rated insulation voltage 1 kV CAT III  Metering range up to 4000 A
 Rogowski coil from 10 to 10000 ARMS – in combination  Voltage supply 24 V DC
with Janitza measurement transducer RogoTrans  Compact construction in a plastic housing
up to 4000 ARMS  Assembly on DIN rail possible
 CE-certified (2014/30/EU)and tested in accordance with
the standard IEC 61010-1
 IP67, unique AC current transformer with separating core

20
Smart Energy & Power Quality Solutions

Split-core current transformer


for the UMG 20CM

Record the operating current with the UMG 20CM Recording the operating and residual currents
with the UMG 20CM

 Compact, divisible, split-core current transformer  Compact, divisible, split-core current transformer
 Separable current transformer up to max. 63 A for  Suitable for residual current monitoring
retrofitting in existing systems  High measurement accuracy
 Specially designed for use with the UMG 20CM  Simple installation thanks to clip technology
 Transformation ratio: 3000/1  Specially designed for use with the UMG 20CM
 Precision class: 1  Transformation ratio: 700/1
 Round conductor: Ø 10 mm  Precision class: 1
 Dimensions: 41.4 x 32 x 32.3 mm  Round conductor: Ø 8 mm
 Current transformer per IEC 61869-2  Dimensions: 35 x 35 x 16 mm
 UL and EN 61010-1 certified

21
Smart Energy & Power Quality Solutions

Split-core current transformer


for the UMG 20CM

Rapid installation – reliable measurement

 Transformation ratio: 3000/1 to 6000/1


 Snap-in technology makes installation in existing equipment
 Max. operating current: 100 A to 600 A
easier
 Precision class: 0.5 and 1
 High number of secondary windings
 Round conductor: 16 to 36 mm
 Secure latching in place, small size, low weight
 Dimensions: 55 x 29.5 x 31 mm to 91.4 x 57.1 x 40.2 mm
 Suitable for the UMG 20CM
 Current transformer per IEC 60044-1

22
Smart Energy & Power Quality Solutions

6-fold DIN rail


current transformer for the UMG 20CM

Monitor, assess and treat

 Current transformer for operating and residual current suitable for the measurement device UMG 20CM
 Residual current acquisition with integrated current transformers (residual currents per IEC 60755 type A)
 6 measurement channels, individually adjustable for operating current or residual current
 Compact construction, DIN rail mounting
 Parallel acquisition and processing of measured values
 Use in distribution outputs for consumers and systems

23
Smart Energy & Power Quality Solutions

Measurement of the CGP


(central ground point)

24
Smart Energy & Power Quality Solutions

Feedthrough residual
current transformer

Detection of very small currents

 Compact construction  Transformation ratio: 700/1


 Makes it possible, in conjunction with the UMG  Internal diameter: Ø 35 mm ... 210 mm
measurement device, to determine the residual current to  Dimensions: 92 x 113 x 56 to 290 x 323 x 64 mm
earth of machines or systems  Current transformer per IEC 60664-1
 Suitable for the UMG 96RM-E, UMG 96RM-PN,  Max. primary residual current: 21000 mA
UMG 509, UMG 512 and UMG 20CM

25
Smart Energy & Power Quality Solutions

Moulded case
current transformer

Rogowski coil

Cable split core


current transformer

RCM

PE

26
Smart Energy & Power Quality Solutions

Split-core residual
current transformer

Handy and compact

 Simple and economical installation  Transformation ratio: 600/1


 Practical locking system: Separating and detachment of  Max. primary residual current: 18000 mA
primary cores not required  Conductor feed-through: 20 x 30 to 80 x 120 mm (W x H)
 Available in various different sizes  Dimensions: 93 x 106 x 58 to 155 x 198 x 58 mm (W x H x D)
 No interruption of operations  Applied technical standards:
 Suitable for UMG 96RM-E, UMG 20CM, UMG 509 DIN EN 61869, part 1 + 2; IEC 61010-2;
and UMG 512 Low voltage directive 2014/35/EU

27
Smart Energy & Power Quality Solutions

Split-core residual
current transformer

Easy to handle and can be retrofitted

 Makes it possible, in conjunction with the UMG  Transformation ratio: 700/1


measurement device, to determine the residual current to  Round conductor: Ø 110 to 310 mm
earth of machines or systems (e.g. insulation faults)  Dimensions: 235 x 219 mm to 400 x 416 mm (W x H)
 C ompact construction
 Detection of very small currents
 Suitable for the UMG 96RM-E, UMG 96RM-PN,
UMG 509, UMG 512 and UMG 20CM

28
Smart Energy & Power Quality Solutions

Differential current
transformer type B+
for the UMG 96RM-E

Ever-vigilant – intelligent current transformer

 Recording of DC type B+ residual currents (up to 300 mA)  Standard interface 4–20 mA


 Pre-alarm in the event of faults  Internal diameter: Ø 35 and 70 mm
 Continuous monitoring of residual currents  Dimensions: 106 x 113 and 141 x 143 (W x H)
 Reduction of the DGUV V3 (substitute for insulation  24 V DC supply voltage
measurement in stationary electrical systems)  Current sensor per EN 62020, DIN IEC 381
 Simple implementation of fire and system protection part 1: 1989-11
 Decentralised direct shutdown of system parts
 Simple installation and commissioning
 Autonomous relay output
 Local test button

29
Smart Energy & Power Quality Solutions

Example measurement system

30
Smart Energy & Power Quality Solutions

Current transformer
fault curve
Überstrombereich
für Messwandler FS5

Überstrom
für Messw
Fi / %
Arbeitsstrombereich
Ei / %
6 Überstrombereich
für Messwandler FS5
5
4 Überstrombereich
Fehlergrenzkurve für Kl. 3
3 für Messwandler FS10
Fi / % 2 Arbeitsstrombereich
Ei / % 1
6
5 0
2 3 4 5 10 20 50 100 120 200 500 1000
4 1
Fehlergrenzkurve für Kl. 3 %/
3 2 1
r cl.
r ve fo
2 3 it Cu
r Lim
Erro Error Limit Curve fpr cl. 3
1 4
0
25 3 4 5 10 20 50 100 120 200 500 1000
1 6 % / IN
2 l. 1
rc
rve fo
3 it Cu
r Lim
Erro Error Limit Curve fpr cl. 3
4
5 FS5-Grenze

6 Working Current Area FS5-limit

Overcurr
FS5-Grenze c.t.´s FS
Overcurrent Area for
Working Current Area FS5-limit
c.t.´s FS5

Overcurrent Area for


c.t.´s FS10
Overcurrent Area for
c.t.´s FS5

Beispiel eines Strom-Messwandlers der Kl. 1 FS5 bei 1/1 Bürde Beispiel eines Schutzwandlers 10P10 bei 1/1 Bürde

Example for a measuring c.t. of cl. 1 FS5 at 1/1 burden Example for a protection c.t. 10P10 at 1/1 burden

Beispiel eines Strom-Messwandlers der Kl. 1 FS5 bei 1/4 Bürde Beispiel eines Schutzwandlers 10P10 bei 1/4 Bürde
Beispiel eines Strom-Messwandlers deraKl.
Example for 1 FS5 bei c.t.
measuring 1/1 Bürde
of cl. 1 FS5 at 1/4 burden Beispiel eines Schutzwandlers 10P10 bei 1/1for
Example Bürde
a protection c.t. 10P10 at 1/4 burden
Example for a measuring c.t. of cl. 1 FS5 at 1/1 burden Example for a protection c.t. 10P10 at 1/1 burden

Beispiel eines Strom-Messwandlers der Kl. 1 FS5 bei 1/4 Bürde Beispiel eines Schutzwandlers 10P10 bei 1/4 Bürde

Example for a measuring c.t. of cl. 1 FS5 at 1/4 burden Example for a protection c.t. 10P10 at 1/4 burden

31
Smart Energy & Power Quality Solutions

Current transformer accessories

Useful accessory

Protection and safety through integration and installation aids

In conjunction with the current transformers, Janitza offers The modularly constructed current transformer terminal blocks
helpful accessories, such as voltage tap-offs and current on the other hand are suitable for installation on DIN rails and
transformer terminal blocks. Voltage tap-offs can be used, are required for the short-circuiting of current transformers or
for example, for measurement purposes and to tap off the for monitoring measurements. In addition, they can also be
voltage on current-conducting rails. They ensure high levels used as insulated bridges for earthing and short circuiting the
of operational reliability, a protected measurement voltage transformer terminal.
connection and can be easily installed.

Terminals to tap off the voltage Insulated tool


on current-conducting rails

Current transformer terminal block –


Protected measurement voltage Short circuiting of current transformers,
connection monitoring measurement of energy
measurement devices

32
Smart Energy & Power Quality Solutions

Janitza product range

Hand in hand

No current transformers without measurement devices

The Janitza current transformers and the UMG measurement meters. Because all Janitza devices have a wide selection of
devices represent an ideal combination. Current transformers communication and interface facilities, the area of Industry 4.0
convert almost any level of primary current into "bite-sized" is nothing new, but rather has been part of our daily business for
secondary current, which can be recorded and displayed by years. So, Janitza offers not only the corresponding hardware,
UMG measurement devices. Almost any current transformer but also the associated software through which the data can be
can be combined with the energy measurement devices. recorded, displayed and evaluated. With this, Janitza offers the
customers an individual tailored solution where the software
The Janitza measurement devices are suitable for front panel and hardware components are ideally matched to one another.
mounting or for DIN rail mounting. The product portfolio ranges "Made in Germany" is the Janitza seal of quality. For over
from universal measurement devices through power quality 30 years this has attested to our excellent quality.
analysers with class A certification through to MID energy

33
Smart Energy & Power Quality Solutions

Energy Monitoring Systems


„Made in Germany“
Log energy data, display energy consumption, reduce costs
Nowadays, energy management is not only relevant for the environment and for society but is also a critical ✔
competitive factor. Only those who can keep a close eye on their energy consumption can reduce costs and
increase efficiency. To ensure optimum use of the measurement devices, Janitza offers the corresponding
accessories and tailored software - a complete package that guarantees efficient energy management.

The comprehensive Janitza product portfolio ranges from the current transformer and measurement device, from
the communications devices and the IT environment, right through to software solutions and databases including
data analyses and evaluations. After formulating the technical solution, on request Janitza provides support
throughout the entire product life cycle. For more information visit our website at www.janitza.com

Digital energy
measurement devices
Individual, tailored
solutions for RCM, energy
and power quality
measurement technology
GridVis® network
Commissioning to meet every visualisation software
requirement Software for the development
Commissioning of the
monitoring systems of an RCM, energy and power
quality monitoring system

Service
Energy-Portal (SaaS)
Janitza provides support
with selection, The Cloud solution for
maintenance and support MADE your energy management
of the systems IN
GERMANY

APPs
Training
Software-based develop-
Training of the personnel
ments with ‘know-how’
Current
transformers

The link between heavy


current and measurement
technology

34
Smart Energy & Power Quality Solutions

35
Smart Energy & Power Quality Solutions

CURRENT TRANSFORMER
TECHNICAL DATA
Smart Energy & Power Quality Solutions

Moulded case current


transformer Class 1 and 0.5 to / 5 A
Device overview, moulded case current transformer, class 1 … / 5 A secondary current*
Type Primary current in A Power in VA Primary conductor Round conductor in mm Width in mm Weight (kg) Item no.
IPA40.5 60 2 40 x 10; 30 x 15; 25 x 20 30 70 0.6 09.05.347
IPA40 75 2 40 x 10; 30 x 15; 25 x 20 30 70 0.4 09.05.348
6A315.3 100 2.5 30 x 15 ; 20 x 20 28 60 0.3 09.00.404
6A315.3 150 5 30 x 15; 20 x 20 28 60 0.3 09.00.452
6A315.3 200 5 30 x 15, 20 x 20 28 60 0.3 09.00.424
6A315.3 250 5 30 x 15; 20 x 20 28 60 0.3 09.00.425
6A315.3 300 5 30 x 15; 20 x 20 28 60 0.3 09.00.426
6A315.3 400 5 30 x 15; 20 x 20 28 60 0.3 09.00.427
6A315.3 500 5 30 x 15; 20 x 20 28 60 0.3 09.00.428
6A315.3 600 5 30 x 15; 20 x 20 28 60 0.3 09.00.429
7A412.3 800 5 40 x 12; 2 x 30 x 10 33 70 0.4 09.00.981
7A412.3 1,000 5 40 x 12; 2 x 30 x 10 33 70 0.4 09.00.982
8A512.3 1,250 5 50 x 12; 2 x 40 x 10 42 85 0.5 09.01.412
8A512.3 1,500 5 50 x 12; 2 x 40 x 10 42 85 0.5 09.01.413
9A615.3 1,500 5 63 x 15; 2 x 50 x 10 53 95 0.5 09.01.900
9A615.3 1,600 10 63 x 15; 2 x 50 x 10 53 95 0.5 09.01.901
9A615.3 2,000 10 63 x 15; 2 x 50 x 10 53 95 0.5 09.01.902
9A615.3 2,500 10 63 x 15; 2 x 50 x 10 53 95 0.5 09.01.903

Device overview, moulded case current transformer, class 0.5 … / 5 A secondary current*
Type Primary current in A Power in VA Primary conductor Round conductor in mm Width in mm Weight (kg) Item no.
IPA40.5 60 2 40 x 10; 30 x 15; 25 x 20 30 70 0.6 09.05.349
IPA40.5 75 2 40 x 10; 30 x 15; 25 x 20 30 70 0.6 09.05.350
IPA40.5 100 2.5 30 x 15 ; 20 x 20 30 70 0.5 09.05.351
IPA40.5 150 10 30 x 15; 20 x 20 30 70 0.6 09.05.236
6A315.3 200 3.75 30 x 15, 20 x 20 28 60 0.3 09.00.360
6A315.3 250 5 30 x 15; 20 x 20 28 60 0.3 09.00.361
6A315.3 300 5 30 x 15; 20 x 20 28 60 0.3 09.00.362
6A315.3 400 5 30 x 15; 20 x 20 28 60 0.3 09.00.363
6A315.3 500 5 30 x 15; 20 x 20 28 60 0.3 09.00.364
6A315.3 600 5 30 x 15; 20 x 20 28 60 0.3 09.00.365
7A412.3 800 5 40 x 12; 2 x 30 x 10 33 70 0.4 09.00.887
7A412.3 1,000 5 40 x 12; 2 x 30 x 10 33 70 0.4 09.00.888
8A512.3 1,250 5 50 x 12; 2 x 40 x 10 42 85 0.4 09.01.339
9A615.3 1,500 5 63 x 15; 2 x 50 x 10 53 95 0.5 09.01.820
9A615.3 1,600 10 63 x 15; 2 x 50 x 10 53 95 0.5 09.01.821
9A615.3 2,000 10 63 x 15; 2 x 50 x 10 53 95 0.5 09.01.822
9A615.3 2,500 10 63 x 15; 2 x 50 x 10 53 95 0.5 09.01.823

Accessories
Snap fastening For DIN rail EN 50022-35, suitable for 9A615.3, IPA40 style, 1 pair 0.01 09.09.000
Snap fastening For DIN rail EN 50022-35, suitable for 6A315.3, 7A412.3, 8A512.3 and 9A615.3 style, 1 pair 0.01 09.09.001
Snap fastening For DIN rail EN 50022-35, suitable for IPA40.5 style, 1 pair 0.01 09.09.002

* Secondary current transformer … / 1 A as well as other types on request.

2
Smart Energy & Power Quality Solutions

Dimension diagrams All dimensions in mm

IPA40 IPA40.5 6A315.3

7A412.3 8A512.3 9A615.3

3
Smart Energy & Power Quality Solutions

Moulded case current transformer


for billing purposes
Class 0.5 to / 5 A

Device overview, moulded case current transformer, class 0.5 … / 5 A Secondary current*
Type Primary current in A Power in VA Primary conductor Round conductor in mm Width in mm Weight (kg) Item no.
30.5 x 10.5; 25.5 x 25.5; 23
EIPA30.5 50 1.25 70 0.4 09.14.810
10.5 x 30.5
30.5 x 10.5; 25.5 x 25.5; 23
EIPA30.5 75 2.5 70 0.4 09.14.812
10.5 x 30.5
EIPA30.5 30.5 x 10.5; 25.5 x 25.5; 23
100 2.5 70 0.3 09.14.811
10.5 x 30.5
E6A315.3 200 2.5 33 x 16; 23 x 23; 16 x 33 28 60 0.3 09.10.340
E6A315.3 250 5 33 x 16; 23 x 23; 16 x 33 28 60 0.3 09.10.367
E6A315.3 300 5 33 x 16; 23 x 23; 16 x 33 28 60 0.3 09.10.366
E6A315.3 400 5 33 x 16; 23 x 23; 16 x 33 28 60 0.3 15.02.907
E6A315.3 500 5 33 x 16; 23 x 23; 16 x 33 28 60 0.3 09.10.364
E6A315.3 600 5 33 x 16; 23 x 23; 16 x 33 28 60 0.3 09.11.365
E7A412.3 800 5 40.5 x 13; 31 x 31; 13 x 40.5 33 70 0.3 09.10.390
E7A412.3 1,000 5 40.5 x 13; 31 x 31; 13 x 40.5 33 70 0.4 09.10.888
E9A615.3 64 x 16; 54 x 32; 42 x 42; 53
1,500 5 95 0.4 09.10.387
32 x 54; 16 x 64
E13A1030.3 1,600 5 101 x 31; 84 x 64; 54 x 81 85 129 0.5 09.12.887
E13A1030.3 2,000 5 101 x 31; 84 x 64; 54 x 81 85 129 0.5 09.12.888
E13A1030.3 2,500 5 101 x 31; 84 x 64; 54 x 81 85 129 0.5 09.12.889

Description Item no.


Declaration of conformity with error directory 09.50.011

* Transformers are manufactured on an order-by-order basis, no stock held, no returns. Current transformers with different primary or secondary currents on request.

4
Smart Energy & Power Quality Solutions

Dimension diagrams All dimensions in mm

EIPA30.5 E6A315.3 E7A412.3

56 56
15

56

16
23

16

16

33
28

33
71

74

74
35,5

64

10,5x30,5

37
37
25,5x25,5
32

16x33 13x40,5
30,5x10,5 23x23 13x40,5 31x31
49 33x16 30 31x31 40,5x13
70 70

30 30 40,5x13
60 70

E9A615.3 E13A1030.3

56
16

85
140

70

54x81
84x64
30 129 101x31

5
Smart Energy & Power Quality Solutions

Moulded case current transformer


for billing purposes
Class 0.2S

Device overview, moulded case current transformer, class 0.2S / 0.5S, 5 A secondary current
Primary Power in Transformation Round conductor Width Weight
Type Class Primary conductor Item no.
current in A VA ratio in mm in mm (kg)
ERM60-E3A 150 0.2S 0 – 1 VA 150/5 A 30 x 10 24.5 60 0.4 09.06.212
ERM60-E3A 200 0.2S 0 – 2 VA 200/5 A 30 x 10 24.5 60 0.4 09.06.213
ERM60-E3A 250 0.2S 0 – 2.5 VA 250/5 A 30 x 10 24.5 60 0.4 09.06.214
ERM70-E4A 300 0.2S 0 – 2.5 VA 300/5 A 40 x 10 30.5 70 0.4 09.06.215
ERM70-E4A 400 0.2S 0 – 5 VA 400/5 A 40 x 10 30.5 70 0.4 09.06.216
ERM70-E4A 500 0.2S 0 – 5 VA 500/5 A 40 x 10 30.5 70 0.4 09.06.217
ERM70-E4B 600 0.2S 0 – 5 VA 600/5 A 40 x 10 30.5 70 0.5 09.06.218
ERM70-E4B 750 0.2S 0 – 5 VA 750/5 A 40 x 10 30.5 70 0.5 09.06.219
ERM85-E6A 1000 0.2S 0 – 5 VA 1000/5 A 60 x 10 30.6 85 0.6 09.06.220

Accessories
Mounting clips ERM60/ERM70 09.09.012
These transformers are not on stock and will be ordered to customer order, products are excluded from return.

6
Smart Energy & Power Quality Solutions

Dimension diagrams All dimensions in mm

ERM60-E2A ERM60-E3A ERM70-E4A ERM85-E6A

43 43 53 65
H+ 18

H+ 18
H+ 18

H+ 24
H

H
H

H
6,5

6,5

6,5

6,5
Type Height (mm)
A 30
Type Height (mm) B 50 Type Heig
Type Height (mm) A 40
A 30
A 30 B 55
B 50
B 50 C 70
C 70
C 70
80

Ø 22,7

80

Ø 24,5
11,7
13,5
10,5

89

Ø 30,5
17,8
13,8

110

Ø 30,6
16,6
26,2

15,6
10,6
33
23,7

33
26,8
25
28

35
30
28

15,5
20,5
41,7
38,2
37,2

20,5

47
25,5
60 30,6
30,5
60 40,6
70
41
50,6
60,7
85

7
Smart Energy & Power Quality Solutions

Summation current transformer


Class 1 and class 0.5 for feedthrough and split core

Device overview – summation current transformer, class 1


Primary current Secondary Transformation Dimensions in
Type Power in VA Weight (kg) Item no.
in A current in A ratio mm (H x W x D)
IPS20 5+5 5 15 1:1 115 x 45 x 73 0.4 15.02.510
IPS30 5+5+5 5 15 1:1:1 115 x 45 x 73 0.4 15.02.515
IPS40 5+5+5+5 5 15 1:1:1:1 115 x 45 x 73 0.5 15.02.520
IPS20 1+1 1 15 1:1 115 x 45 x 73 0.5 09.05.306
IPS30 1+1+1 1 15 1:1:1 115 x 45 x 73 0.5 09.05.316
IPS40 1+1+1+1 1 15 1:1:1:1 115 x 45 x 73 0.5 09.05.326
IPS21 5+5 5 15 Customer-specific 115 x 45 x 73 0.4 15.02.526
IPS31 5+5+5 5 15 Customer-specific 115 x 45 x 73 0.4 15.02.521
IPS41 5+5+5+5 5 10 Customer-specific 115 x 45 x 73 0.5 15.02.525

Device overview – summation current transformer, class 0.5


Primary current Secondary Transformation Dimensions in
Type Power in VA Weight (kg) Item no.
in A current in A ratio mm (H x W x D)
IPS20 5+5 5 15 1:1 115 x 45 x 73 0.5 15.02.511
IPS30 5+5+5 5 15 1:1:1 115 x 45 x 73 0.5 15.02.516
IPS40 5+5+5+5 5 15 1:1:1:1 115 x 45 x 73 0.5 15.02.519

Not to be used in conjunction with split-core current transformers.


*1 Other currents on request.

Dimension diagrams All dimensions in mm

8
Smart Energy & Power Quality Solutions

Summation current transformer


Class 1 for cable type split core current transformers

Device overview – summation current transformer, class 1


Primary current Secondary Transformation Dimensions in
Type Power in VA Weight (kg) Item no.
in A current in A ratio mm (H x W x D)
STS20 1+1 1 0.2 1:1 80 x 30 x 60 0.2 15.02.560
STS30 1+1+1 1 0.2 1:1:1 80 x 30 x 60 0.2 15.02.561
STS40 1+1+1+1 1 0.2 1:1:1:1 80 x 55 x 60 0.4 15.02.562
STS50 1+1+1+1+1 1 0.2 1:1:1:1:1 80 x 55 x 60 0.4 15.02.563
STS60 1+1+1+1+1+1 1 0.2 1:1:1:1:1:1 80 x 55 x 60 0.4 15.02.564
STS21 1+1 1 0.2 Customer-specific 80 x 30 x 60 0.2 15.02.570
STS31 1+1+1 1 0.2 Customer-specific 80 x 30 x 60 0.2 15.02.571
STS41 1+1+1+1 1 0.2 Customer-specific 80 x 55 x 60 0.4 15.02.572
STS51 1+1+1+1+1 1 0.2 Customer-specific 80 x 55 x 60 0.4 15.02.573
STS61 1+1+1+1+1+1 1 0.2 Customer-specific 80 x 55 x 60 0.4 15.02.574

With dissimilar main transformers, the ratio of the largest to the smallest primary current should not be greater than 10:1.

Dimension diagrams All dimensions in mm

STS20 / STS30 / STS21 / STS31 STS40 / STS50 / STS60 / STS41 / STS51 / STS61

9
Smart Energy & Power Quality Solutions

Cable split core


current transformers
Series KUW1 for insulated cable up to max. 18 mm diameter
Primary Secondary Power in VA Cable length Diameter Weight
Type Class Item no.
current in A current in A (at the end of the wire) in m Primary conductor in mm (kg)
KUW1/30-60 60 1 0.2 3 3 18 0.3 15.03.510
KUW1/30-75 75 1 0.2 3 3 18 0.3 15.03.511
KUW1/30-100 100 1 0.2 3 3 18 0.3 15.03.512
KUW1/30-125 125 1 0.2 3 3 18 0.3 15.03.513
KUW1/30-150 150 1 0.2 3 3 18 0.3 15.03.514
KUW1/30-200 200 1 0.2 1 3 18 0.3 15.03.515
KUW1/30-250 250 1 0.2 1 3 18 0.3 15.03.317
KUW1/40-100 100 1 0.2 1 3 18 0.4 15.03.320
KUW1/40-125 125 1 0.2 1 3 18 0.4 15.03.321
KUW1/40-150 150 1 0.2 1 3 18 0.4 15.03.322
KUW1/40-200 200 1 0.2 0.5 3 18 0.4 15.03.325
KUW1/40-250 250 1 0.2 0.5 3 18 0.4 15.03.326
KUW1/40-150 150 5 1 1 0.5 18 0.4 15.03.329
KUW1/40-200 200 5 1 1 0.5 18 0.4 15.03.330
KUW1/40-250 250 5 1 0.5 0.5 18 0.4 15.03.331

Series KUW2 for insulated cable max. 28 mm diameter


Primary Secondary Power in VA Cable length Diameter Weight
Type Class Item no.
current in A current in A (at the end of the wire) in m Primary conductor in mm (kg)
KUW2/40-200 200 1 0.2 1 3 28 0.3 15.03.351
KUW2/40-250 250 1 0.2 1 3 28 0.3 15.03.352
KUW2/40-300 300 1 0.2 1 3 28 0.3 15.03.354
KUW2/40-400 400 1 0.2 1 3 28 0.4 15.03.356
KUW2/40-500 500 1 0.2 0.5 3 28 0.4 15.03.358
KUW2/40-250 250 5 1 1 0.5 28 0.3 15.03.353
KUW2/40-300 300 5 1 1 0.5 28 0.3 15.03.355
KUW2/40-400 400 5 1 1 0.5 28 0.3 15.03.357
KUW2/40-500 500 5 1 1 0.5 28 0.3 15.03.359

Series KUW4/60 for insulated cable up to max. 42 mm diameter


Primary Secondary Power in VA Cable length Diameter Weight
Type Class Item no.
current in A current in A (at the end of the wire) in m Primary conductor in mm (kg)
KUW4/60-250 250 1 0.5 1 5 42 0.6 15.03.565
KUW4/60-300 300 1 0.5 1 5 42 0.6 15.03.566
KUW4/60-400 400 1 0.5 0.5 5 42 0.6 15.03.568
KUW4/60-500 500 1 0.5 0.5 5 42 0.6 15.03.570
KUW4/60-600 600 1 0.5 0.5 5 42 0.6 15.03.572
KUW4/60-750 750 1 0.5 0.5 5 42 0.6 15.03.574
KUW4/60-800 800 1 0.5 0.5 5 42 0.6 15.03.576
KUW4/60-1000 1,000 1 0.5 0.5 5 42 0.6 15.03.578
KUW4/60-300 300 5 0.5 1 3 42 0.6 15.03.367
KUW4/60-400 400 5 0.5 1 3 42 0.5 15.03.369
KUW4/60-500 500 5 0.5 1 3 42 0.6 15.03.371
KUW4/60-600 600 5 0.5 0.5 3 42 0.5 15.03.373
KUW4/60-750 750 5 0.5 0.5 3 42 0.6 15.03.375
KUW4/60-800 800 5 0.5 0.5 3 42 0.6 15.03.377
KUW4/60-1000 1,000 5 0.5 0.5 3 42 0.6 15.03.379

10
Smart Energy & Power Quality Solutions

Series KUW4.2/60 for insulated cable up to max. 2 x 42 mm diameter


Primary Secondary Power in VA Cable length Diameter Weight
Type Class Item no.
current in A current in A (at the end of the wire) in m Primary conductor in mm (kg)
KUW4.2/60-250 250 1 0.5 1 5 42 x 84 0.7 15.03.580
KUW4.2/60-300 300 1 0.5 1 5 42 x 84 0.8 15.03.581
KUW4.2/60-400 400 1 0.5 0.5 5 42 x 84 0.7 15.03.583
KUW4.2/60-500 500 1 0.5 0.5 5 42 x 84 0.8 15.03.585
KUW4.2/60-600 600 1 0.5 0.5 5 42 x 84 0.7 15.03.587
KUW4.2/60-750 750 1 0.5 0.5 5 42 x 84 0.8 15.03.589
KUW4.2/60-800 800 1 0.5 0.5 5 42 x 84 0.8 15.03.591
KUW4.2/60-1000 1,000 1 0.5 0.5 5 42 x 84 0.8 15.03.593
KUW4.2/60-300 300 5 0.5 1 3 42 x 84 0.7 15.03.382
KUW4.2/60-400 400 5 0.5 1 3 42 x 84 0.8 15.03.384
KUW4.2/60-500 500 5 0.5 1 3 42 x 84 0.6 15.03.386
KUW4.2/60-600 600 5 0.5 0.5 3 42 x 84 0.7 15.03.388
KUW4.2/60-750 750 5 0.5 0.5 3 42 x 84 0.8 15.03.390
KUW4.2/60-800 800 5 0.5 0.5 3 42 x 84 0.8 15.03.392
KUW4.2/60-1000 1,000 5 0.5 0.5 3 42 x 84 0.8 15.03.394

Dimension diagrams All dimensions in mm

KUW1/30 KUW1/40 KUW2/40 KUW4/60 KUW4.2/60

11
Smart Energy & Power Quality Solutions

Cable split core


current transformer
Type KBU

Cable split core current transformer, type KBU


Primary Secondary Power in VA Dimensions in mm Weight
Type Class Item no.
current in A current in A A B C / C1 D E (kg)
KBU 58 250 5 1.5 1 125 158 34 / 58 55 85 0.9 15.02.316
KBU 58 400 5 1 0.5 125 158 34 / 58 55 85 0.9 15.02.868
KBU 58 500 5 2.5 0.5 125 158 34 / 58 55 85 0.9 15.02.819
KBU 58 600 5 2.5 0.5 125 158 34 / 58 55 85 1.0 15.02.315
KBU 58 1000 5 5 0.5 125 158 34 / 58 55 85 1.0 15.02.320
KBU 812 600 5 2.5 0.5 155 198 34 / 58 85 125 1.3 15.02.869
KBU 812 800 5 2.5 0.5 155 198 34 / 58 85 125 1.3 15.02.870
KBU 812 1000 5 5 0.5 155 198 34 / 58 85 125 1.3 15.02.871
KBU 812 1250 5 7.5 0.5 155 198 34 / 58 85 125 1.3 15.02.328

Dimension diagrams All dimensions in mm

KBU 58 KBU 812

12
Smart Energy & Power Quality Solutions

Three-phase current transformer


Type ASRD 14

Three-phase current transformer type ASRD 14


Primary cur- Secondary Power in VA Round con- Dimensions in mm Weight
Type Class Item no.
rent in A current in A ductor in mm (W x H x D) (kg)
ASRD 14 50 5 1 1 13.0 105 x 90 x 54 0.5 15.03.403
ASRD 14 75 5 1.5 1 13.0 105 x 90 x 54 0.5 15.03.404
ASRD 14 100 5 2.5 1 13.0 105 x 90 x 54 0.5 15.03.405
ASRD 14 125 5 2.5 0.5 13.0 105 x 90 x 54 0.5 15.03.406
ASRD 14 150 5 2.5 0.5 13.0 105 x 90 x 54 0.5 15.03.407

Dimension diagrams All dimensions in mm

13
Smart Energy & Power Quality Solutions

DIN rail current transformer


With voltage tap-off and back-up fuse

DIN rail current transformer


Type Transmission ratio Power in VA Class Dimensions in mm (H x W x D) Weight (kg) Item no.
CT 35/1A 35/1 A 0.2 1 approx. 72 x 32 x 96 0.2 15.03.002
CT 64/1A 64/1 A 0.2 0.5 approx. 72 x 32 x 96 0.2 15.03.003

Dimension diagrams All dimensions in mm

14
Smart Energy & Power Quality Solutions

Compact current transformer


Class 1

For operating current


Compact current transformer CT27 - class 1
Power in VA Max. primary
Primary current Secondary Dimensions in
Type (on the termi- conductor diam- Weight (kg) Item no.
in A current in A mm (H x W x D)
nals) eter in mm
CT27-35 35 1 0.2 7.5 approx. 46 x 27 x 23 0.05 15.03.080
CT27-64 64 1 0.2 7.5 approx. 46 x 27 x 23 0.04 15.03.081
Accessories

Snap fastening For DIN rail EN 50022-35, suitable for CT27-35 and CT27-64 approx. 14 x 41 x 27 Approx. 0.1 09.09.010

Dimension diagrams All dimensions in mm

For operating current and residual current for the measurement


device UMG 20CM
Device overview - Current transformer CT-20 - operating or residual current transformer type A
Operating or Max. primary
Max. operating Residual current Transformation Dimensions in Weight
residual current conductor diam- Class Item no.
current in A in mA ratio mm (H x W x D) (kg)
transformer type A eter in mm
CT-20 63 (with load) 10 to 1000 700/1 7.5 1 approx. 46 x 27 x 23 0.05 15.03.082
Accessories

Snap fastening For DIN rail EN 50022-35, suitable for type CT-20 approx. 14 x 41 x 27 Approx. 0.1 09.09.010

Pre-finished
1.5 m with load (0.8 Ω) and spring terminal for operating current measurement 15.03.085
connection cable

Dimension diagrams All dimensions in mm

15
Smart Energy & Power Quality Solutions

Flexible current transformer


Rogowski coils
Description Item no. Diameter Length Weight
Rogowski current transformer Ø 70 mm 15.03.609 70 mm 3m 192 g
Rogowski current transformer Ø 175 mm 15.03.610 175 mm 3m 206 g
Rogowski current transformer Ø 300 mm 15.03.611 300 mm 3m 222 g
Rogowski coil, 600mm (without measurement transducer) 15.03.603 190 mm 600 mm 195 g

Technical data
Item no. 15.03.609 15.03.610 15.03.611
Max. output voltage 30 V 30 V 30 V
Primary current*1 up to 10000 A*1 up to 10000 A*1 up to 10000 A*1
Rated transformation ratio (@ 50 Hz) 44,44 kA/V 44,44 kA/V 44,44 kA/V
Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz
Secondary voltage 22,5 mV (at 1000 A / 50 Hz) 22,5 mV (at 1000 A / 50 Hz) 22,5 mV (at 1000 A / 50 Hz)
Mutual inductance 71,98 nH 72,314 nH 72,84 nH
Temperature coefficient of M ±30 ppm/K ±30 ppm/K ±30 ppm/K

Frequency bandwidth (cable length 1,5 m)*2 420 kHz*2 350 kHz*2 300 kHz*2

Phase displacement 0,004°*3 0,004°*3 0,004°*3


Coil inductance 180 µH 343 µH 566 µH
Coil resistance 56 Ω 105 Ω 170 Ω
– 0,5 ... 0,5 % class 0,5 – 0,5 ... 0,5 % class 0,5 – 0,5 ... 0,5 % class 0,5
Ratio error (cenred)
Accuracy per IEC 61869-2 Accuracy per IEC 61869-2 Accuracy per IEC 61869-2
– 0,75 ... 0,75*4 – 0,75 ... 0,75*4 – 0,75 ... 0,75*4
Ration error (all positions)*4
incl. positioning errors incl. positioning errors incl. positioning errors
Linearity error none none none
Influence of external current*5 ±0,2*5 ±0,2*5 ±0,2*5

*1 In combination with Janitza measurement transducer RogoTrans up to 4000 A.


*2 On request, the frequency bandwidth and phase shifting model can be made available.
*3 With installation at a right angle to the phase conductor.
*4 Under consideration that the Janitza Rogowski current transformer is installed perpendicular to a primary conductor of min. Ø 15 mm.
*5 Under consideration that a further phase conductor of min. Ø 15 mm is installed at the same height and at a right angle to the Janitza Rogowski current transformer.

16
Smart Energy & Power Quality Solutions

Measurement transducer
General data for measurement transducer
Item no. 15.03.612
Dimesions 22.5 x 100 x 110 mm (W x H x D)
Weight approx. 0.2 kg
Power supply 24 V DC (18 to 36 V) / 1 A
< 300 mA (with 1 A output current)
Current draw
< 80 mA (without output current)
Janitza Rogowski coil
Input
max. 90 mV (4000 A range)
1 to 4000 A
1 to 2000 A
Current metering ranges 1 to 1000 A
1 to 500 A
1 to 250 A
Metering range setting (button) LED (yellow) Wear-free metering range selection via micro-controller and PGA
Operating and metering range display via 6 LED (green)
Phase angle < 1°
Linearity error at 50 Hz < 0.2% in all metering ranges
Measuring error at 50 Hz < 0.2% in all metering ranges
Input impedance 10 k Ω in all metering ranges
Signal output 0 to 1 A
Measurement range exceeding 110%
Burden 0 to 1.5 Ohm
Linearity error burden 0 to 1.5 Ohm < 0,02%
Alarm output 24 V DC / 200 mA (floating potential optical output, open with fault)
Overload (range exceeding)
Alarm messages (via red LED) Burden too great (output circuit)
Undervoltage (24 V)
Alarm delay 60 seconds
Protection type IP30
Ambient temperature –20°C to +70°C
Vertical; if multiple devices are used next to each other then a minimum distance of 5 mm
Installation position
must be maintained between the devices (heat development)
Storage temperature –25°C to +85°C

17
Smart Energy & Power Quality Solutions

Split-core current transformer


for the UMG 20CM

For operating current


Device overview - Split-core current transformer SC-CT-20
Max. primary
Max. operating Transformation Accuracy Dimensions in mm
Type conductor Class Weight (kg) Item no.
current (A) ratio (%) (H x W x D)
diameter in mm
SC-CT-20* 63 3,000/1 10 1 1 approx. 41.4 x 32 x 32.3 0.04 15.03.092
Individual accessory (load is included the scope of the SC-CT-20 delivery)
Load (3.9 Ω) for operating current transformer SC-CT-20 with 1.5 m connection cable and spring terminal 15.03.086
* Incl. ready-made connection cable; 1.5 m with load and spring terminal for operating current measurement

Dimension diagrams All dimensions


8.5 8.5

6 6
in mm

32 mm 14,7 mm
34

34

32,3 mm
Black White Black White I I

41,4 mm
160 ± 20

160 ± 20

AWG#22 AWG#22

S2(l) S2(l) S1(k) S1(k)


Black White
Black White

For operating current For operating current and residual current for the measurement device
UMG 20CM

For operating current and residual current for the measurement


device UMG 20CM
Device overview - Split-core current transformer SC-CT-21
Max. primary
Residual current Transformation Accuracy Dimensions in mm
Type conductor Class Weight (kg) Item no.
(mA) ratio (%) (H x W x D)
diameter in mm
SC-CT-21 10 to 1,000 700/1 8 1 1 approx. 35 x 35 x 16 0.05 15.03.084

18
Smart Energy & Power Quality Solutions

Split-core current transformer


for the UMG 20CM

For operating current


Technical data
Type SC-CT-20-100 SC-CT-20-200 SC-CT-20-300 SC-CT-20-400 SC-CT-20-500 SC-CT-20-600
Current ratio 120 A / 40 mA 200 A / 66.6 mA 300 A / 100 mA 400 A / 100 mA 500 A / 100 mA 600 A / 100 mA
0.01 to 100 A 0.01 to 200 A 0.1 to 300 A 0.01 to 400 A 0.01 to 500 A 0.01 to 600 A
Current range (50/60 Hz)
(RL = 10 Ohm) (RL = 10 Ohm) (RL = 10 Ohm) (RL = 5 Ohm) (RL = 5 Ohm) (RL = 5 Ohm)
Position of installation Use in indoor areas (any mounting position)
Operating temperature -20 to +50 °C -20 to +55 °C
Storage temperature -30 to +90 °C, rel. humidity <85 % (no condensation)

Device overview - Divisible operating current transformer up to 600 A


Max.
Max. primary Dimensions
Transformation Accuracy in mm (H x W x D) Weight
Type Operating mode operating conductor Item no.
ratio (%) (kg)
current in A diameter in
mm A B C D E
Operating current Approx.
SC-CT-20-100 100 3000/1 16 1 55 41 29.5 31 19 15.03.093
measurement*1 0.075
Operating current
SC-CT-20-200 200 3000/1 24 1 74.5 52 45 34 22 Approx. 0.2 15.03.094
measurement*1
Operating current
SC-CT-20-300 300 3000/1 24 1 74.5 52 45 34 22 Approx. 0.2 15.03.095
measurement*1
Operating current
SC-CT-20-400 400 4000/1 36 0.5 91.4 57.0 57.1 40.2 21.1 Approx. 0.3 15.03.097
measurement*1
Operating current
SC-CT-20-500 500 5000/1 36 0.5 91.4 57.0 57.1 40.2 21.1 Approx. 0.3 15.03.099
measurement*1
Operating current
SC-CT-20-600 600 6000/1 36 0.5 91.4 57.0 57.1 40.2 21.1 Approx. 0.3 15.03.101
measurement*1
Individual accessory (load is included the scope of the transformer delivery)
Load (2.2 Ω) for operating current transformer SC-CT-20-100 with 1.5 m connection cable and spring terminal 15.03.087
Load (1.1 Ω) for operating current transformer SC-CT-20-200 with 1.5 m connection cable and spring terminal 15.03.088
Load (0.8 Ω) for operating current transformer SC-CT-20-300/400/500/600 with 1.5 m connection cable and spring terminal 15.03.085

* Incl. ready-made connection cable; 1.5 m with load and spring terminal for operating current measurement
1

Dimension diagrams All dimensions in mm


Abmessungen in mm / Anschlussbild

D C
I

E L K

Ød l k
SC

M3 Schraube M3 Schraube

k l

19
Smart Energy & Power Quality Solutions

Split-core residual
current transformer
Technical data
General
Construction style Low voltage residual current transformer
Housing material Polycarbonate, grey RAL 7035
Max. voltage for electrical equipment Um < = 0.72 kV
Insulation test voltage 3 kV Ueff.; 50 Hz; 1 min
Rated frequency 50 Hz
Secondary connection Brass profile, nickel plated, max. 4.0 mm2
Nominal ratio Ipn / Isn 10 / 0.0167 A
Working frequency range 30 … 1000 Hz
Secondary rated apparent power 0.05 VA
Operational temperature range -5 to +45 °C
Max. temperature of the primary conductor 90 °C

Device overview - split-core residual current transformer type A


Max. primary residual Dimensions in mm
Type Transformation ratio Weight (kg) Item no.
current in mA*1 A B C / C1 D E
KBU 23D*2 600/1 18000 93 106 34/58 20 30 0.7 15.03.400
KBU 58D*2 600/1 18000 125 158 34/58 55 85 1.1 15.03.401
KBU 812D*2 600/1 18000 155 198 34/58 85 125 1.5 15.03.402
Accessories
Burden (3,9 Ω) with 1.5 m ready-made connection cable and spring type terminal adapter 15.03.086

*1
When using the analogue inputs of the UMG 96RM-E, UMG 96RM-PN, UMG 509-PRO and UMG 512-PRO.
*2
If the Differential current transformer of the series KBU is in use with the UMG 20CM, the measuring range of the UMG 20CM can be stepped up also higher
from 900 mA to 14 A and from 1 to 15 A by integrating a burden, item no. 15.03.086.

Dimension diagrams All dimensions in mm

20
Smart Energy & Power Quality Solutions

General data
Insulation voltage 0.72 kV
Frequency 3 kHz
Operating temperature -10 to +55 °C
Test voltage 3 kV RMS 50 Hz / 1 min.

Device overview - Plug-in residual current transformer type A


Max. primary residual
Type Transformation ratio Item no.
current in mA*
CT-AC RCM A110N 700/1 21000 15.03.462
CT-AC RCM A150N 700/1 21000 15.03.465
B
CT-AC RCM A310N 700/1 21000 15.03.461
28 100
* When using the analogue inputs
6 of the UMG 96RM-E, UMG 96RM-PN, UMG 509 and UMG 512
10

C
A E D
59 47

Gewicht 200g

Dimension diagrams All dimensions in mm

CT-AC RCM A110N/150N

S1 S2

S3 S4

Fig. CT-AC RCM A310N


C A

310 30

400 B 79

Dimensions - Plug-in residual current transformer type A


M ODELE POIDS
Gewicht 3,8Kg
Dimensions in mm Weight
Type
A B C (kg)
CT-AC RCM A110N 110 235 219 2.35
CT-AC RCM A150N 150 275 259 2.50
CT-AC RCM A310N 310 400 416 3.80

21
Smart Energy & Power Quality Solutions

Feedthrough residual
current transformer
General data
Insulation voltage 0.72 kV
Frequency 3 kHz
Operating temperature -10 to +55 °C
Test voltage 3 kV RMS 50 Hz / 1 min.

Device overview – Feedthrough residual current transformer type A


Max. primary residual current
Type Transformation ratio Item no.
in mA*
CT-AC RCM 35N 700/1 21000 15.03.458
CT-AC RCM 80N 700/1 21000 15.03.459
CT-AC RCM 110N 700/1 21000 15.03.463
CT-AC RCM 140N 700/1 21000 15.03.460
CT-AC RCM 210N 700/1 21000 15.03.464
* When using the analogue inputs of the UMG 96RM-E, UMG 96RM-PN, UMG 509 and UMG 512

Dimension diagrams All dimensions in mm


B

C
A E D

Dimensions – Feedthrough residual current transformer type A


Dimensions in mm Weight
Type
A B C D E (kg)
CT-AC RCM 35N 35 92 113 36 56 0.25
CT-AC RCM 80N 80 125 160 36 56 0.35
CT-AC RCM 110N 110 165 198 36 56 0.50
CT-AC RCM 140N 140 200 234 36 56 0.70
CT-AC RCM 210N 210 290 323 44 64 1.20

22 S1 S2

S3 S4
Smart Energy & Power Quality Solutions

Differential current transformer


Type B+
Overview of devices
Internal con- Dimensions in mm
Max. primary resid-
Attribute DC supply voltage sumption Item no.
ual current in mA A B C D E

CT-AC/DC type B+ 35 RCM 24 V (21.6 to 26.4 V) 0.3 A max. 1.5 W 35 106 104 113 69 15.03.469

CT-AC/DC type B+ 70 RCM 24 V (21.6 to 26.4 V) 0.3 A max. 1.5 W 70 141 104 143 69 15.03.468

Accessories
1-phase switched mode power supply devices in the installation housing
Prim. 115 – 230 V 50/60 Hz, sec. 24 V DC; 1 A 16.05.002
Dimensions in mm (H x W x D): 90.5 x 52 x 62.5; Weight: Approx. 169 g

Dimension diagrams All dimensions in mm


D
E

G
F

B H
C

Dimensions differential current transformer type B+


Dimensions in mm
Type
A B C D E F G H
CT-AC/DC Typ B+ 35 RCM 35 99 106 69 66 87 113 104
CT-AC/DC Typ B+ 70 RCM 70 134 141 69 66 100 143 104

23
Smart Energy & Power Quality Solutions

6-fold DIN rail current transformer

General data
Number of measuring channels 6 (measurement transformer integrated)
Measured value acquisition Parallel, real effective value measurement ("True RMS")
Residual or operating currents (configurable as
Evaluation
required)
Rated isolation level 4 kV
Transformer rated voltage max. 720 V AC
Transformer rated frequency 50 to 60 Hz
Therm. rated short-term current 60 x In / 1 sec.
Therm. Continuous current 100%
Environmental temperature -10 to +55 °C
Class 1
Protection class E
Protection class IP20

6-fold DIN rail current transformer CT-6-20 (operating and residual current transformer type A)

Residual Number of Internal


Operating Dimensions
Operating current in measuring Transformation Measurement transformer
Type current with in mm Weight (kg) Item no.
mode*1 mA channels*2 ratio accuracy diameter in
load in A (H x W x D)
mm

Residual or
CT-6-20 operating 0 to 63 10 to 1,000 6 700/1 1 11 45 x 174 x 56 0.30 14.01.630
currents

Accessories
Ready-made connection cable 1.5 m twisted, screened with connector 08.02.440

* Pre-configurable as needed via DIP switch


1
* Measurement transformer integrated.
2

174,00 mm

Operating current and RCM fault sensor strip for UMG20CM

Dimension diagrams All dimensions in mm


Janitza electronics GmbH
T1 T2
T3 T2 T3
T3 T5
45,00 mm

Vor dem Polstück 1


D-35633 Lahnau Deutschland
X1
ON - Operating Current Mode
www .janitza.de OFF - RCM-Mode
OC ON
ON ON ON ON ON ON
RCM OFF

CT -6-20 T4 T4
T2 T5 T5 T6
T4 1 2 3 4 5 6
number of CT

Ib max: 63A
Ratio: 1/700 Burden RCM/Operating Current: 0/1 Ohm Made in Germany Idiff max: 1000mA

174,00 mm 21,00

Operating current and RCM fault sensor strip for UMG20CM


Janitza electronics GmbH
56,00 mm

T1 T2
T3 T2 T3
T3 T5
45,00 mm

Vor dem Polstück 1


D-35633 Lahnau Deutschland
X1
ON - Operating Current Mode
www .janitza.de OFF - RCM-Mode
OC ON
ON ON ON ON ON ON
RCM OFF

CT -6-20 T4 T4
T2 T5 T5 T6
T4 1 2 3 4 5 6
number of CT

Ib max: 63A
Ratio: 1/700 Burden RCM/Operating Current: 0/1 Ohm Made in Germany Idiff max: 1000mA

21,00
56,00 mm

24
Smart Energy & Power Quality Solutions

Voltage tap-offs

Voltage tap-offs
Max. operating voltage 690 V
Test voltage / pulse 3 kV / 50 Hz 6 kV
In max. 10 A
Insulation class E (max. 120°)
Fuse type 5 x 25 mm (with notification), 10 A SIBA DIN 41576-2
Environmental temperature -5 to +40 °C*1
Temperature increase, rail Max. 75 K*1
Primary connection M8 Allen screw
Allen size Number 6
Max. rail thickness 4 – 15 mm
Housing Polyamide (PA6.6) *1 Max. temperature of the primary rail 120 ºC (total
of environmental temperature and temperature
Terminal material Nickel plated brass increase of the rail)

Device overview - Voltage tap-off


Cross-section
Back-up connection Dimensions in mm (H x W x D) Weight
Type Colour Description Item no.
fuse (A) measurement (kg)
conductor (mm²) A B
ZK4S Black With fuse 6.3 1.5 – 4 71 78 0.2 10.11.525
ZK4B Blue Without fuse - 0 – 16 58.2 76 0.1 10.11.526
Accessories
1 x voltage tap-off set 3 x ZK4S (item no. 10.11.525); 1 x ZK4B (item no. 10.11.526) 0.7 10.11.527
ZK4R Insulated tool for fastening the tap-off; 1,000 V, EN / IEC 60900 0.9 10.11.528

Dimension diagrams All dimensions in mm


ZK4S-ZK4B

15 B
42,7

15,2 13,9

A
50
36,6
12


12

25
Smart Energy & Power Quality Solutions

Voltage tap-offs
Environmental conditions
Installation location Only in indoor areas (suitable for copper rails)
Temperature range for use -10 to +55 °C
Relative humidity 5 to 85 % (no thawing)
Protection class IP20 (basic insulation)
Application conditions
Standard IEC 60947-7-3
Umax 400 V ~
Test voltage 3 kV / 50 Hz
Surge voltage 6 kV 1.2 / 50 µs
Imax 2A
Voltage drop < 500 m V ~
2 A, 450 V, F, 70 kA, 5 x 25 mm, ceramic
Fuse
(SIBA Part.no. 7008913.2 )
Torque max. 2.0 Nm

Device overview – Voltage tap-off


Cross-section
Primary connec- Dimensions in mm (H x W x D)
Back-up fuse connection
Type Colour tion (mm) Weight (kg) Item no.
(A) measurement
conductor (mm²) A B
ZK4/M6 Black 6 2 1.5 – 4 18.8 13.5 0.03 10.11.534
ZK4/M8 Black 8 2 1.5 – 4 23.2 17 0.03 10.11.535

Dimension diagrams All dimensions in mm


ZK4M6-M8

M6/M8 B
14

36,5 A
46,9

26
Smart Energy & Power Quality Solutions

Current transformer
terminal block
General data
DIN mounting rail installation 35 mm DIN rail
Connection max. 4 transformers
4 pairs, 2-conductor, disconnecting and measurement terminals with contact protected test sockets
Test connector (ø) 4 mm (with switching bridge)
Rated voltage EN 500 V
Measurement surge voltage 6 kV
Rated current 30 A
Pollution degree 3
Connection design CAGE CLAMP® S
Type of conductor Single or fine-stranded Each terminal is labelled. The terminal position S2 on
Fine stranded diameter 0.5 – 6 mm² each transformer is connected to ground potential via
"f" + "e" diameter 0.5 to 10 mm² a fixed, pre-installed bridge. Each pair of disconnecting
and measurement terminals is equipped with a yellow
"f" diameter with AEH 0.5 to 6 mm² switch lock for the disconnect lever. 2 disconnect levers
Stripping length 13 – 15 mm are coupled together via an interlocking cap.

Device overview – Current transformer terminal block


Measurement Dimensions in
Nominal Rated voltage Diameter Weight
Type voltage surge Type of conductor mm Item no.
current (A) EN (V) (mm²) (kg)
(kV) (H x W x D)
Current transformer terminal strip 30 500 6 Single or fine-stranded 0.5 – 6 190 x 85 x 65 0.3 15.07.001

Dimension diagrams All dimensions in mm

86.3

1 2 3 4 5 6 7 8
49.9

PE L1 L1 L2 L2 L3 L3 N N
50.9

S1 S2 S1 S2 S1 S2 S1 S2

27
Smart Energy & Power Quality Solutions

Janitza electronics GmbH


Vor dem Polstück 6 | 35633 Lahnau
Germany

Phone: +49 6441 9642-0


Fax: +49 6441 9642-30
[email protected] | www.janitza.com