Anti Stick Acrylic Clear Coat: Technical Data Sheet

This technical data sheet provides information on an acrylic clear coat paint. It has excellent weathering and alkaline resistance. It dries within 1 hour and can be recoated after 2 hours. It has a theoretical coverage of 6 square meters per liter per coat when applied at 80-100 micrometers thickness. The paint uses acrylic resin as the binder and can be thinned up to 30% with solvents. It is recommended for use on concrete and plastered walls to protect from fungus and exterior conditions.

Uploaded by

Jeh Tat Wong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
132 views2 pages

Anti Stick Acrylic Clear Coat: Technical Data Sheet

This technical data sheet provides information on an acrylic clear coat paint. It has excellent weathering and alkaline resistance. It dries within 1 hour and can be recoated after 2 hours. It has a theoretical coverage of 6 square meters per liter per coat when applied at 80-100 micrometers thickness. The paint uses acrylic resin as the binder and can be thinned up to 30% with solvents. It is recommended for use on concrete and plastered walls to protect from fungus and exterior conditions.

Uploaded by

Jeh Tat Wong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TECHNICAL DATA SHEET

ANTI STICK ACRYLIC CLEAR COAT Updated Aug’16

Nippon Acrylic Finish is an acrylic resin based finish with excellent alkaline and weathering
resistance
Product Features:
• Excellent alkaline resistance
• Excellent weathering resistence
• Highly resistant to fungus and exterior condition.
• Easily remove illegal advertisement with adhesive sticker

Paint Type Product Finishing Recommended Pack Size


Type Substrate
Solvent based Exterior Matt Concrete / 1, 5, 20 Litres
plastered wall
Composition
Pigment : Clear
Binder : Acrylic resin
Thinner : Combination of Ester, Ketone and Hydrocarbon
Technical Data
Drying Time : Touch Dry : 20 minutes (Dependent on temperature and humidity)
: Hard Dry : 1 hour (Dependent on temperature and humidity)
Recoating Time : Minimum 2 hours (Dependent on temperature and humidity)
Dry Fil Thickness :80 - 100 m per coat
No. of Coats : 2 coats
Theoretical Coverage : 6 m2 per litre per coat (Actual coverage is dependent on substrate condition, application method,
application condition and finishing appearance)
It is recommended to go for actual application to estimate the practical coverage for project.
Volume Solid : Not Applicable
Shelf Life : Up to 24 months in tight sealed container

Application Method
Brush/ Roller Dilute with 10% – 30% Nippon Acrylic 3000 Thinner or Nippon Acrylic 3000 SD Thinner.
For internal wall application, it is recommended to apply paint using short hair roller and dilute
with Nippon Acrylic 3000 SD Thinner for better film appearance.
Recommended Coating System
CONCRETE /
PLASTERED WALL

Intermediate Coat : Anti Stick Acrylic Clear BASECOAT : 1 coat

Top Coat : Anti Stick Acrylic Clear FINISH : 1 Coat

Surface Preparation

CONCRETE / PLASTERED WALL


Remove all loose, defective paint or powdery residues. Repair cracks, uneven surfaces with Nippon ACS Putty or suitable
fillers. Smoothen the putty/filler areas with sandpaper. Surfaces to be painted must be cleaned thoroughly and dry, it must
be free from dirt, grease and other foreign matters. Allow all surfaces to dry completely prior to painting. Avoid painting
when the moisture content and alkalinity of the walls are still high. (Recommended painting specification requires the
moisture content of the walls to be below 16% measured by protimeter and alkalinity of the wall to be below pH9.)

P a g e 1|2
TECHNICAL DATA SHEET
Cleaning
Clean up equipment with thinner immediately after use.

Safety Precautions
• Keep container tightly closed and keep out of reach children or away from food and drink.
• Ensure good Ventilation during application and drying.
• When applying paint, it is advisable to wear eye protection.
• In case of contact with eye, rinse with plenty of water immediately and seek medical advice.
• Remove splashes from skin by using soap or water.
• Paint must always be stored in a cool place.
• When transporting paint, care must be taken. Always keep container in a secure upright position.
• Dispose off any paint waste in accordance with the appropriate Environment Quality Regulations.

Note
* Theoretical Coverage is based on a mathematical formula

𝑉𝑜𝑙𝑢𝑚𝑒 𝑆𝑜𝑙𝑖𝑑 % 𝑥 10
[ ] = m2/lit/coat
𝐷𝑟𝑦 𝐹𝑖𝑙𝑚 𝑇ℎ𝑖𝑐𝑘𝑛𝑒𝑠𝑠

and does not consider LOSS FASTORS.


Variables like porosity of substrate, application method, dilution ratio, dry film thickness, opacity and so on will affect the
loss factor and can vary from 30% - 50% or even more.

The above information is given to the best of our knowledge based on laboratory tests and practical experience.
However, since we cannot anticipate or control the many conditions under which our products may be used, we can only
guarantee the quality of the product itself.
We reserve the right to alter the given without prior notice

P a g e 2|2