NORTH

Copyright documenta on
18.498
0.200 3.500 0.200 4.100 0.200 4.000 0.200 4.300 0.200 NOTES
0.200 0.215 0.376 2.750 2.750 2.512 2.994 2.994 4.499
0.200 1.100 1.500 0.900 1.487 1.000 1.000 1.473 1.500 1.250 0.200 0.610 1.845 0.200

S-01
ROOF DETAILS GENERAL

0.200
All dimensions are in mm unless otherwise specified.
o

1.481
Pitch- 22 Drawings are not to be scalled. only figured dimensions to be used
0.200

0.200

Eaves overhang - 400mm The contractor must check and verify all dimensions before

1.300
commencement of any work .

0.200
BEDROOM 2 Ra ers to be securely CONSTRUCTION
cer. tiles fastened to the ridgeboard All slab at ground level to be poured over 1000 guage polythene

0.610
3.500

3.500

0.200
sheet on 50mm thick murram blinding on 250 mmhardcore
.

4.404
Ba ens to be securely fastened to

1.800
BEDROOM 1 MASTER BATH All soil under slab around and under foundaon to be poisoned
cer. tiles Non-slip for termite control.
the ra ers.

2.892

0.600
cer. tile
0.200

0.200

0.538 CIVIL
WEST

0.200
1.613 Distribu on of ba ens, purlins, All soil on cut embarkment to be stabilized.The slope not to

EAST
0.200
exceed the natural angle of repose
0.745

11.479
collar es to S.E detail.

0.322

1.470

12.208
cer. tiles

12.708
STRUCTURAL
2.100
0.610

BATHROOM LOUNGE All black co on soil to be removed from al l buildings and paved
cer. tiles surfaces
0.745

Non-slip

1.500
cer. tile For all R.C work,refer to stuctural Engineer's details.
DINNING

4.800
Depth of foundaon to be detemined on site to S . E's aproval

4.408
0.200

0.200

BEDROOM 3 All walls less than 150mm thick to be reinfoced with hoop iron at
cer. tiles every alternate course.
MASTER BEDROOM

2.600

1.830
KITCHEN ISLAND
cer. tiles All adjacent R .C. work and masonary walls to beded with strip iron
3.500

3.500

at every alternate course.

0.200
0.200
MECHANICAL
0.200 0.998 KITCHEN
0.900

Non-slip All plumbing and drainage to comply with relevant local authority

1.915
1.733
cer. tile

1.929

1.929
PANTRY SVP denotes soil vent pipe to be provided ahead of the drainage
2.200

Non-slip system

1.229
cer. tile
0.200

0.200

Drains passing beneath buildings& driveways to be encased in150mm


1.100

3.302 concrete surround.


0.472

0.200
The storm drain pipes to comply with BS 556 specificaon .
All underground foul and waste drain pipes shall be uPVC to comply
0.200

0.579

with BS 5255.
3.700 3.451 3.451 3.390 4.506
All inspec on chambers covers and framing shal l be cast iron.
18.498
S-01

Minimum slope in the drains pipes to be 1 in 100


No chases will be allowed for pipes. Sleeves will be allowed with
ROOF PLAN wrien ap proval of structural Eng's. No cung of concret e without
1.200 1.500 1.000 0.970 1.500 1.453 0.900 0.928 1.500 1.450 1.400 1.500 1.600 SCALE: 1:100 express approval of the Architect or structural Eng.
0.200 3.500 0.200 4.902 0.200 3.198 0.200 4.300 0.200 All tes ng of pipes must be completed before plastering .
All mechanical works must be co-odinated with electrical and any
SOUTH conflict must be clarified be work begin.
PV denotes permanent ven la on
FLOOR PLAN
SCALE: 1:100 ROOF STRUCTURE:
Roof consists of Septic Tank Details REVISIONS
Galvanised G.I 200 3,200 200
GL GL

roofing sheets 22* 450X600mm MANHOLE 8mm Ө MAIN BAR AT


12mm Ө MAIN BARS AT 300mm CENTRES

degrees inclina on COVER AND FRAME

120
300mm C/C 150mm THK
GL GL 8mm Ө DISTR. BARS AT 200mm CENTRES 12mm Ө BARS AT 150mm CONC. BLOCKS
12mm Ө MAIN BARS AT 300mm CENTRES CENTRES BOTH WAYS

supported on Wooden 450X600mm MANHOLE 8mm Ө MAIN BAR AT

120
GL COVER AND FRAME GL 200mm C/C
INLET MANHOLE

350
450X600mm

150
OUTLET MANHOLE 150mm THK
C1 4 Ө INLET PIPE C1 4 Ө OUTLET PIPE MANHOLE COVER
10mm Ө MAIN BAR

trusses

450
BLOCK WORK 1000 C/C

No of Units

100

450
IL E

250

250

E
TO FRENCH DRAIN OR

150
TWL SOAK PIT AS SPECIFIED
A B C 150mm THK STONE

Ceiling to Dets.

'H' Varries
150
BLOCKS TO DRAIN INVERT
WATER LEVEL 'H' DEPTH OF SOAK PIT Date

150
150
12mm Ө MAIN BARS

500
AS SPECIFIED OR

550
100mm th. CONCRETE
FOUNDATION MIX 1:3:6
AT 200mm CENTRES DIRECTED BY DRAWING
No of Floors
1500mm x 1500mm A B C

200mm th. SOAK PIT DETAIL


Steel casement

F2
100 BLOCK WORK 200mm THK
150 600 200

1,400
200mm th BLOCK WORK
BLOCK WORK D
12mm WATER PROOF
CEMENT -SAND RENDERING
Approx. Area
PLAN WITH COVER LIGHTLY COMPACTED

200mm thick plastered 12mm WATER PROOF CEMENT-


SAND PLASTER SLAB REINFORCEMENT GL SUITABLE SPORT FILLINGS GL

Masonry wall, Masonry


12mm WATER PROOF 1,000
Total. Area

150
CEMENT-SAND PLASTER

COMPACTED MURRAM

200
400

150
keys exterior finish, Interior 400 150 mm CONCRETE 1:2:4 - 3/4 GRADED

SECTION X-X
CAPACITY
NUMBER
OF DIMENSIONS IN MILLIMETRES NOTES
POLYTHENE SHEET OR
ANY OTHER APPROVED
MATERIAL

Septic Tank Details


PERSONS
to be plastered and painted SECTION Y-Y
GALLONS LITRES A B C D E F F2 1. CONCRETE TO BE 1:2;3 3/4"

600
CRUSHED STONES
300 1360 UPTO TO 10 400 300 1300 2200 700 900 1360 GRADED AND TO BE ACCORDING
600 2720 11-20 750 600 1350 2900 900 1100 2720 TO GENERAL SPECIFICATION.
in 2coats pure sa n emulsion 900
1200
4080
5440
21-30
31-40
900
900
750
850
1350
1350
3200
3300
1100
1300
1200
1300
4080
5440
2. REINFORCEMENT TO BE MILD STEEL
TO BS 785.
6" PERFORATED CLAY OR
PITCH FIBRE PIPES 600mm
LONG WITH 50mm OPEN JOINTS

paint on appropriate 1500 6800 41-50 1000 950 1350 3500 1400 1400 6800 3. MINIMUM COVER TO BARS SHALL

undercoat
1800

3000

5000

8000
7500

13600

25600

39200
51-60

91-100

101-200

201-300
1000

1500

2500

4000
1050

1900

3500

5400
1350

1550

2050

3600
3600

5000

7000

13600
1500

2000

2800

3600
1500

2000

2800

3600
7500

10600

13600

18600
BE 25mm.
4. 1:2 CEMENT SAND RENDERING ON
WALLS AND SCUM BAFFLES.
FRENCH DRAIN DETAIL
PROJECT TITLE
250mm well compacted Septic Tank Details PROPOSED RESIDENTIAL
Hardcore fill
150mm R.c slab DEVELOPMENT ON PLOT
Depth of founda on NUMBER:.................................
SECTION 1-1 to be determined on site
min 1200mm
..................................................
SCALE: 1:100
GITHIRA-LAKIPIA COUNTY
ROOF STRUCTURE:
Roof consists of Galvanised G.I
roofing sheets 22*degrees .
inclina on
supported on Wooden trusses DRAWING TITLE
2.992
WORKING DRAWING
200mm thick plastered
Masonry wall, Masonry
keys exterior finish, Interior
to be plastered and painted CLIENT:

5.249
Car park
in 2coats pure sa n emulsion
paint on appropriate
undercoat 0.200 3.500 0.200 4.100 0.200 4.000 0.200 4.300 0.200
PATRICK GITAHI

0.200
0.200

1.502
1.300

0.200
EAST ELEVATION NORTH ELEVATION

3.500

0.200
SCALE: 1:100 SCALE: 1:100

1.800
2.892
0.200
0.538
1.613
Designed Checked:
ROOF STRUCTURE:

0.200
and drawn by:

0.322
Roof consists of Galvanised G.I

0.600
2.100
. roofing sheets 22*degrees BATHROOM

inclina on

4.800
supported on Wooden trusses.

0.200

2.600
3.500

0.200
200mm thick plastered 0.200 0.998 S. MURIITHI P.W

0.900
Masonry wall, Masonry

1.733
1.929
0726812262 0717642129

2.200
keys exterior finish, Interior

0.200

1.100
to be plastered and painted . 3.302

0.472

0.200
in 2coats pure sa n emulsion

0.200

0.579
paint on appropriate
undercoat. 0.200 3.500 0.200 4.902 0.200 3.198 0.200 4.300 0.200

SITE LAYOUT Scale AS SPECIFIED Job No:


SOUTH ELEVATION SOUTH ELEVATION SCALE: 1:200

Date 8-05-2021 A0521-01


SCALE: 1:100 SCALE: 1:100
GSPublisherVersion 0.15.100.100