CHIMEI INNOLUX DISPLAY CORPORATION

LCD MODULE
S P E C I F I C AT I O N

Customer:
Model Name: EJ101IA-01F
Date: 2012/01/03
Version: 01

■ Preliminary Specification
□ Final Specification

For Customer ’s Acceptance


Approved by Comment

Approved by Review ed by Prepared by

Stanley.CW.Leung Green Fu David Lee

2012/01/04 2012/01/04 2012/01/03

http://www.Datasheet4U.com
InnoLux copyright 2004
All rights reserved,
Copying forbidden.

Record of Revision
Version Revise Date Page Content
Pre-Spec.01 2012/01/03 Initial Release
CHIMEI INNOLUX
Contents
1. General Specifications ............................................................................................................ 1
2. Pin Assignment....................................................................................................................... 2
3. Operation Specifications ......................................................................................................... 4
3.1. Absolute Maximum Ratings ............................................................................................ 4
3.2. Typical Operation Conditions.......................................................................................... 4
3.3. Power Sequence ............................................................................................................ 5
3.4. LVDS Signal Timing Characteristics ............................................................................... 6
3.4.1. AC Electrical Characteristics .................................................................................. 6
3.4.2. Timing Table ........................................................................................................... 7
3.4.3. LVDS Data Input Format......................................................................................... 8
4. Optical Specifications.............................................................................................................. 9
5. Reliability Test Items ............................................................................................................. 13
6. General Precautions ............................................................................................................. 14
6.1. Safety ........................................................................................................................... 14
6.2. Handling ....................................................................................................................... 14
6.3. Static Electricity ............................................................................................................ 14
6.4. Storage ......................................................................................................................... 14
6.5. Cleaning ....................................................................................................................... 14
7. Mechanical Drawing ............................................................................................................. 15
8. Package Drawing ................................................................................................................. 16
8.1. Packaging Material Table............................................................................................... 16
8.2. Packaging Quantity........................................................................................................ 16
8.3. Packaging Drawing........................................................................................................ 16
CHIMEI INNOLUX Date: 2012/01/03 Page:1/17

1. General Specifications

No. Item Specification Remark

1 LCD size 10.1 inch(Diagonal)

2 Driver element a-Si TFT active matrix

3 Resolution 1280 × 3(RGB) × 800

4 Display mode Normally Black, Transmissive

5 Dot pitch 0.0565(W) × 0.1695(H) mm

6 Active area 216.96(W) × 135.60(H) mm

7 Module size 229.46(W) ×149.1(H) ×2.40(D) mm Note 1

8 Surface treatment HC

9 Color arrangement RGB-stripe

10 Interface Digital

11 Backlight power consumption TBD (Typ.) Note 1

12 Panel power consumption TBD (Typ.) Note 1

13 Weight TBD(Max)

Note 1: Refer to Mechanical Drawing.


Note 2: Including LED Driver power consumption.
Note 3: Including T-con Board power consumption
CHIMEI INNOLUX Date: 2012/01/03 Page:2/17

2. Pin Assignment
A 40pin connector is used for the module electronics interface. The recommended model is
F62240-H1210A manufactured by Vigorconn.

Pin No. Symbol I/O Function Remark


1 NC --- No connection
2 VDD P Power Supply
3 VDD P Power Supply
4 NC --- No connection
5 NC --- No connection
6 NC --- No connection
7 NC --- No connection
8 Rxin0- I -LVDS Differential Data Input
R0-R5, G0
9 Rxin0+ I +LVDS Differential Data Input
10 VSS P Ground
11 Rxin1- I -LVDS Differential Data Input
G1~G5, B0,B1
12 Rxin1+ I +LVDS Differential Data Input
13 VSS P Ground
14 Rxin2- I -LVDS Differential Data Input B2-B5,HS,VS,
15 Rxin2+ I +LVDS Differential Data Input DE

16 VSS P Ground
17 RxCLK- I -LVDS Differential Clock Input
LVDS CLK
18 RxCLK+ I +LVDS Differential Clock Input
19 VSS P Ground
20 Rxin3- I -LVDS Differential Data Input R6, R7, G6, G7,
21 Rxin3+ I +LVDS Differential Data Input B6, B7

22 VSS P Ground
23 LED_GND P LED Ground
24 LED_GND P LED Ground
25 LED_GND P LED Ground
26 NC --- No connection
CHIMEI INNOLUX Date: 2012/01/03 Page:3/17
27 LED_PWM I PWM Control Signal of LED Converter Note2
28 NC --- No connection
29 CABC_EN I CABC Enable Input Note1
30 NC --- No connection
31 LED_VCCS P LED Power
32 LED_VCCS P LED Power
33 LED_VCCS P LED Power
34 NC --- No connection
35 NC --- No connection
36 NC --- No connection
37 NC --- No connection
38 NC --- No connection
39 NC --- No connection
40 NC --- No connection

I: input, O: output, P: Power

Note1: The setting of CABC function are as follows.

Pin Enable Disable


CABC_EN High Voltage Low Voltage or open

Note2: LED_PWM is used to adjust backlight brightness.

Luminance
Bright

Luminance
Dark

Duty (0%) Duty (100%)


CHIMEI INNOLUX Date: 2012/01/03 Page:4/17

3. Operation Specifications

3.1. Absolute Maximum Ratings


(Note 1)
Values
Item Symbol Unit Remark
Min. Max.
VSS=0V,
VDD -0.3 5.0 V
TA=25℃
Power voltage
LED_VCCS -0.3 6.5 V

Operation Temperature TOP 0 50 ℃

Storage Temperature TST -20 60 ℃

Note 1: The absolute maximum rating values of this product are not allowed to be exceeded
at any times. Should a module be used with any of the absolute maximum ratings
exceeded, the characteristics of the module may not be recovered, or in an extreme
case, the module may be permanently destroyed.

3.2. Typical Operation Conditions


(GND=0V, TA=25 oC)
Values
Item Symbol Unit Remark
Min. Typ. Max.
VDD 3.0 3.3 3.6 V
Power voltage
LED_VCC
S
4.8 5.0 6.2
Input logic high VIH 3.0 3.3 3.6 V
voltage
Input logic low VIL 0 - 0.5 V
voltage
IVDD - TBD TBD mA VDD=3.3V
Current for Driver
ILED_VCC LED_VCCS
- TBD TBD mA =5V,Duty=100%
S
PWM High V
Level
3.0 - 3.6
PWM Control Level
PWM Low V
Level
0 - 0.4

PWM Control fPWM 1K - 20K Hz


Frequency
CHIMEI INNOLUX Date: 2012/01/03 Page:5/17
3.3. Power Sequence

a. Power on:

b. Power off:
CHIMEI INNOLUX Date: 2012/01/03 Page:6/17
3.4. LVDS Signal Timing Characteristics
3.4.1. AC Electrical Characteristics

Parameter Symbol Values Unit Remark


Min. Typ. Max.
LVDS Differential input high
RxVTH - - +100 mV
Threshold voltage
RXVCM=1.2V
LVDS Differential input low
RxVTL -100 - - mV
Threshold voltage
LVDS Differential input common
RxVCM 0.7 - 1.6 V
mode voltage
LVDS Differential voltage |VID| 250 - 600 mV
CHIMEI INNOLUX Date: 2012/01/03 Page:7/17
3.4.2. Timing Table

Values
Item Symbol Unit Remark
Min. Typ. Max.

Frame rate
Clock Frequency 1/Tc (68.9) 71.1 (73.4) MHz
=60Hz

Horizontal display area tHD 1280 Tc

HS period time tH (1410) 1440 (1470) Tc


HS Width +Back Porch tHW + tHBP
(60) 160 (190) Tc
+Front Porch +tHFP
Vertical display area tVD 800 tH

VS period time tv (815) 823 (833) tH


VS Width +Back Porch tvW + tvBP
(15) 23 (33) tH
+Front Porch +tvFP
CHIMEI INNOLUX Date: 2012/01/03 Page:8/17
3.4.3. LVDS Data Input Format
CHIMEI INNOLUX Date: 2012/01/03 Page:9/17

4. Optical Specifications

Values
Item Symbol Condition Unit Remark
Min. Typ. Max.

θL Φ=180°(9 o’clock) 75 85 -

θR Φ=0°(3 o’clock) 75 85 -
Viewing angle
degree Note 1
(CR≥ 10)
θT Φ=90°(12 o’clock) 75 85 -

θB Φ=270°(6 o’clock) 75 85 -

TON - 10 20 msec Note 3


Response time
TOFF - 15 30 msec Note 3

Contrast ratio CR 600 800 - - Note 4

WX Normal 0.26 0.31 0.36 - Note 2


θ=Φ=0°
Color chromaticity Note 5
WY 0.28 0.33 0.38 - Note 6

Luminance L 300 350 - cd/m² Note 6


Luminance
YU 70 75 - % Note 7
uniformity

Test Conditions:
1. VDD=3.3V, IL=240mA (Backlight current), the ambient temperature is 25℃.
2. The test systems refer to Note 2.
CHIMEI INNOLUX Date: 2012/01/03 Page:10/17
Note 1: Definition of viewing angle range

Normal line
θ=Φ=0°

Φ=90°
12 o’clock direction

θL
θT θR
θB

Φ=180° Φ=0°
Active Area

LCM

Fig. 4-1 Definition of viewing angle Φ=270°


Note 2: Definition of optical measurement system. 6 o’clock
direction
The optical characteristics should be measured in dark room. After 30 minutes
operation, the optical properties are measured at the center point of the LCD
screen. (Viewing angle is measured by ELDIM-EZ contrast/Height :1.2mm,
Response time is measured by Photo detector TOPCON BM-7, other items are
measured by BM-5A/ Field of view: 1° /Height: 500mm.)

Photo detector Normal line


θ=Φ=0°

Φ=90°
12 o’clock direction
500mm

Φ=180° Φ=0°
Active Area

LCM

Φ=270°
6 o’clock direction

Fig. 4-2 Optical measurement system setup


CHIMEI INNOLUX Date: 2012/01/03 Page:11/17

Note 3: Definition of Response time


The response time is defined as the LCD optical switching time interval between
“White” state and “Black” state. Rise time (TON) is the time between photo detector
output intensity changed from 90% to 10%. And fall time (TOFF) is the time
between photo detector output intensity changed from 10% to 90%.

White (TFT OFF) Black (TFT ON) White (TFT OFF)


Photo detector output

100%
(Relative value)

90%

10%
0%
TON TOFF

Fig. 4-3 Definition of response time

Note 4: Definition of contrast ratio


Luminance measured when LCD on the " White" state
Contrast ratio (CR) =
Luminance measured when LCD on the " Black" state

Note 5: Definition of color chromaticity (CIE1931)


Color coordinates measured at center point of LCD.

Note 6: All input terminals LCD panel must be ground while measuring the center area of
the panel. The LED driving condition is IL=240mA .
CHIMEI INNOLUX Date: 2012/01/03 Page:12/17

Note 7: Definition of Luminance Uniformity


Measure the luminance of gray level 63 at 9 points
δW 9p = {Minimum [L (1)+ L (6)+ L (7)+ L (8)+ L (9)+ L (10)+ L (11) +L (12) +L (13)] /
Maximum [L (1)+ L (6)+ L (7)+ L (8)+ L (9)+ L (10)+ L (11) +L (12) +L (13)]}*100%
10mm

6 7 8
H/4

2 3

X : Test Point
H/4

X=1 to 13
9 1 10
H
H/4

4 5
H/4

11 12 13

10mm 10mm
10mm

W/4 W/4 W/4 W/4


W
Active area
CHIMEI INNOLUX Date: 2012/01/03 Page:13/17

5. Reliability Test Items


(Note3)
Item Test Conditions Remark

High Temperature Storage Ta = 60℃ 240hrs Note 1,Note 4

Low Temperature Storage Ta = -20℃ 240hrs Note 1,Note 4

High Temperature Operation Ts = 50℃ 240hrs Note 2,Note 4

Low Temperature Operation Ta = 0℃ 240hrs Note 1,Note 4

Operate at High Temperature


+40℃, 90%RH 240hrs Note 4
and Humidity
-20℃/30 min ~ +60℃/30 min for a total 100
Thermal Shock cycles, Start with cold temperature and end Note 4
with high temperature.
Frequency range:10~55Hz
Stroke:1.5mm
Vibration Test Sweep:10Hz~55Hz~10Hz
2 hours for each direction of X. Y. Z.
(6 hours for total)

100G 6ms,±X, ±Y, ±Z 3 times for each


Mechanical Shock
direction
Random Vibration :
0.015G*G/Hz from 5-200HZ, -6dB/Octave
Package Vibration Test from 200-500HZ
2 hours for each direction of X. Y. Z.
(6 hours for total)
Height:60 cm
Package Drop Test
1 corner, 3 edges, 6 surfaces

Electro Static Discharge ± 2KV, Human Body Mode, 100pF/1500Ω


Note 1: Ta is the ambient temperature of samples.
Note 2: Ts is the temperature of panel’s surface.
Note 3: In the standard condition, there shall be no practical problem that may affect the
display function. After the reliability test, the product only guarantees operation,
but don’t guarantee all of the cosmetic specification.
Note 4: Before cosmetic and function test, the product must have enough recovery time,
at least 2 hours at room temperature.
CHIMEI INNOLUX Date: 2012/01/03 Page:14/17

6. General Precautions
6.1. Safety

Liquid crystal is poisonous. Do not put it in your mouth. If liquid crystal touches your
skin or clothes, wash it off immediately by using soap and water.

6.2. Handling

1. The LCD panel is plate glass. Do not subject the panel to mechanical shock or to
excessive force on its surface.
2. The polarizer attached to the display is easily damaged. Please handle it carefully
to avoid scratch or other damages.
3. To avoid contamination on the display surface, do not touch the module surface
with bare hands.
4. Keep a space so that the LCD panels do not touch other components.
5. Put cover board such as acrylic board on the surface of LCD panel to protect panel
from damages.
6. Transparent electrodes may be disconnected if you use the LCD panel under
environmental conditions where the condensation of dew occurs.
7. Do not leave module in direct sunlight to avoid malfunction of the ICs.

6.3. Static Electricity

1. Be sure to ground module before turning on power or operating module.


2. Do not apply voltage which exceeds the absolute maximum rating value.

6.4. Storage

1. Store the module in a dark room where must keep at 25±10℃ and 65%RH or less.
2. Do not store the module in surroundings containing organic solvent or corrosive
gas.
3. Store the module in an anti-electrostatic container or bag.

6.5. Cleaning

1. Do not wipe the polarizer with dry cloth. It might cause scratch.
2. Only use a soft sloth with IPA to wipe the polarizer, other chemicals might
permanent damage to the polarizer.
CHIMEI INNOLUX Date: 2012/01/03 Page:15/17

7. Mechanical Drawing
CHIMEI INNOLUX Date: 2012/01/03 Page:16/17

8. Package Drawing

8.1. Packaging Material Table

TBD

8.2. Packaging Quantity

TBD

8.3. Packaging Drawing

TBD