Airslide Calculation Form Project: Department: Equipment No

This document contains an airslide calculation form for a cement project. It provides information for selecting material properties like density and weight, as well as airslide dimensions like length, inlet and discharge sizes, number of blowers, and estimated blower power. Dimensions are in millimeters. The airslide slope for layout is specified as 8 degrees. Walkways of 800mm and 600mm are recommended on each side unless a specific size is requested. The airslide top should be 1200mm from the walkway top with a minimum 750mm gap below for piping and an inspection door. The airslide trough length should be maintained at 3000mm.

Uploaded by

Manoj Thakur
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
2K views

Airslide Calculation Form Project: Department: Equipment No

This document contains an airslide calculation form for a cement project. It provides information for selecting material properties like density and weight, as well as airslide dimensions like length, inlet and discharge sizes, number of blowers, and estimated blower power. Dimensions are in millimeters. The airslide slope for layout is specified as 8 degrees. Walkways of 800mm and 600mm are recommended on each side unless a specific size is requested. The airslide top should be 1200mm from the walkway top with a minimum 750mm gap below for piping and an inspection door. The airslide trough length should be maintained at 3000mm.

Uploaded by

Manoj Thakur
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

AIRSLIDE CALCULATION FORM

PROJECT:
DEPARTMENT:
EQUIPMENT NO:

INSERT
RESULT

Density Weight Blower volume No. of Vent volume Approx. Blower


Select Material Cap. (TPH) Length A B C D
t/m³ (kg./m) (m³/h) Blowers (m³/h) Shaft Power (KW)

Cement 0.80 99 4500 300 32 400 75 39 243 1 243 0.822

Nominal * All Dimensions Are In Millimeters


cap. * Considered Blower capacity Maximum 2000 m³/h for each blower
cu.m/hr.
Air slides slopes for layout purpose
124 Select Material Angle
Cement 8°
Airslide Inlet Box Airslide Discharge Box

Ф 400
degree of Airslide
Ф 350 to suit (0° to 15°)

Ф 300
16 nos. Ф 14 Holes Equally Spaced to Top /
Straddle Center lines Fa 340 555
bric
5 Thk Flange

degree of Airslide
to suit (0° to 15°)
555 360
5
Thk Flange
16 nos.
Ф 14 Holes Equally Spaced to
Ф 300 Straddle Center lines
350
Ф 350

300 0 Ф 400

Discharge & Vent Flange are identical

Rectangular Inlet Flange Size, Flange Inside 300 SQ. Rectangular Discharge Flange Flange Inside 300 SQ.
If Required Bolt Holes 360 SQ. Size, If Required Bolt Holes 360 SQ.
Flange Outside 400 SQ Flange Outside 400 SQ

Flange Thickness Same As Circular Size Flange Thickness Same As Circular Size
1 Keep clear walkway 800 & 600 each side of the Air slide unless client requested for specific size.

2 Maintain air slide top 1200 from top of walkway but make sure that min 750 gap is available below air slide
for aeration piping & inspection door.

3 Maintain air slide trough length 3000