Specification Index
Specification Index
Specification Index
Item Applicable
ITEM DESCRIPTION
No. specification reference
1 Clearing and grubbing site/road/land including uprooting all
vegetation, grass, bush shrubs, saplings and trees with girth, removal of
stumps of trees of girth of all sizes including removing stumps of trees
cut earlier and disposal of unserviceable materials and stacking of As per attached
serviceable materials as directed by Engineer with all leads and lifts seprate sheet
etc. complete as per specification. before commencement and after
completion of the work.
2 Demarkation of road alignment including marking out road line by
providing and fixing wooden pegs or steel rod of required size at every
25 M to 50 M including excavating trenches ion both sides of 0.30 m x As per attached
0.30m including supplying of labours and all materials for every work seprate sheet
etc complete.
3 Dismentaling the flexible pavement including removing and stacking
the dismentalled materials as and where directed - Granular Course As per attached
seprate sheet
(b) Pier Cap, Abutment Cap, Padestal & Seismic Arrestor As per attached
seprate sheet
15 Providing and applying Coal Tar Epoxy protective paint for Pile Cap in
two coats of DFT 210 microns for foundations /concrete surfaces in As per attached
contact with soil complete as per Specifications and as directed by seprate sheet
the Engineer including all leads and lifts etc. complete.
16 Providing and casting in situ or precast controlled cement concrete M
45 for Prestressed concrete work in super structure including centering,
shuttering, curing, scaffolding, ramming, vibrating, finishing, launching As per attached
or shifting complete. (i) Solid Slab (ii) Deck Slab (iii) Main Girder (iv) seprate sheet
Diaphram or Cross Girder.
17 Providing & fixing in position (Thermo mechanically treated bars ) TMT
Fe500 D steel bars of various diameters for all RCC works in super
structure as per detailed design & drawings and schedule including
cutting, bending, hooking the bars, binding with 18 SWG GI wires and
supporting as required with all lifts and leads etc. complete including
As per attached
cost of all labour, materials, tools, plants, equipments etc. all complete
seprate sheet
as directed by Engineer and as per specifications.
(i) P.S.C. Girder
(ii) Diaphram (Cross Girder)
(iii) Deck Slab
18 Providing and fixing in position to exact profile High tensile steel wires
12.7/15.2mm dia of required ultimate strength conforming to low
Relaxation Prestressing steel strands including bending, cutting, tying
providing necessary standards as per IS 14268 and anchorages, As per attached
sheathing (HDPE), stressing, grouting, ducts as per detailed drawing seprate sheet
including necessary plant and machinary complete.
19 Providing and fixing in position fully moulded restrained elastomeric As per attached
bearings as per detailed drawings. seprate sheet
20 Providing and carrying out load test on bridge deck with simulated
loading including provision, placing and removal of loading,
supplying, fixing and removing deflection measuring instruments etc.
complete with platforms for fixing the instruments etc. complete as per As per attached
the details supplied and specification and as directed by Engineer seprate sheet
and including submission of required results in triplicate after
satisfactory completion of the load test.
Specification Index
Item Applicable
ITEM DESCRIPTION
No. specification reference
21 Providing and casting RCC in M-40 controlled concrete Crash Barriers
as per detailed drawings including necessary scaffolding, centering,
formwork, mixing in machine, transporting, placing, compacting, As per attached
finishing, curing, etc. complete including providing and fixing of inserts seprate sheet
if any with all leads and lifts as per drawing & specification and as
directed by Engineer, excluding reinforcement.
22 Providing and casting insitu controlled cement concrete M-35 in RCC
Approach Slab including formwork, curing and finishing complete. As per attached
seprate sheet
27 Providing and fixing 100 mm dia. G.I. Drainage spouts, as per MOST
Drg. No. SD/303 including grating with suitable clean out fixtures As per attached
including all leads and lifts etc. complete as per specification, design seprate sheet
& drawings and as directed by Engineer.
28 Providing and fixing in position strip seal type expansion joints as per
detailed drawing and approved Sp. including cost of all materials and
fixtures, welding, preparing surface for receiveing the joints including As per attached
all leads and lifts etc complete as per detailed approved drawing and seprate sheet
Sp. and as directed by Engineer. (Upto 40 mm Expansion)
Specification Index
Item Applicable
ITEM DESCRIPTION
No. specification reference
29 Providing and applying two coats of 100% acralic breathable, Anti-
carbonation, Water proof, Heat Insulating decorative external coating
of sunanda or equivalent of approved shade after applying a primer
coat of same materail. Mix 1 lit. of Acralic paint and applying it as a
primer allow it to dry for 4-6 hours. Mix 1 liter of anticarbonation paint
with 400-600 ml. of water and apply two coats using brush/roller/spray
at 24 hours of interval between each coat. Acralic paint shall be
spray/brush/roller applied with minimum DFT of 200-250 microns and
shall conform to the following properties. Carbon dioxide diffusion
equvalent air layer thickness(DIN EN 1062-6) > 100 m.: Carbon Dioxide
diffusion resistance coefficient (DIN EN 1060-6) > 105 when tested as
per DIN EN 1062-6 from a research institution NBA accredited Grade A As per attached
and internationaly ranked among top 5 research institution in the seprate sheet
world in annual survey conducteed by Georgia Institute of
Technology, ranking of research institutions; Elongation of cured film
shall be as per ASTMD 2370/98 > 400 %; Cloride Ion Diffusion (ASTM C
1202)=Zero penetration ; Adhesion to concrete (ASTM D 4541) > 2
N/mm2 ; Solar reflective index (ASTM E 1980-11, EN 673:2011, EN
410:2011) >104, Whwn tested from Government approved laboratory
CEPT or equivalent. The inter-coat gap to be 24 hours. The rate shall
include complete treatment mentioned above.
41 Box cutting the road surface to proper slope and camber for making a
base for road work including removing the excavated stuff and As per attached
depositing on the road side slope as directed upto 50m lead. seprate sheet
52 Cat Eye / Road Stud / RPM : supplying raised pavemnt markers made
of polycarbonate & ABS moulded body and reflective pannels with
micro prismatic lense (No glass bead lens) capable of providing total
internal reflection of the lightentering the lens face & self support a
load of 13635 kgs. Tested in accordance to ASTM D, 4280 type H and
complying to spcifications of category A of MORTH circular no. RW/NH
/33023/10-97-DO III Dt. 11.06.1997. The height , width and length shall
not exceeed 20 mm , 130 mm and 130 mm and with minimum
reflective area of 13 sqcm on each side and the slope to the base As per attached
shall be 35+/-5 degree. The strength of detachment of the intrigrated seprate sheet
cylinder shanks (of diameter not less than 19+/-2 mm and height not
less than 30+/-2 mm from the body is to be min. value of 500 kgf. fixing
will be by drilling holes on the road for the shank to go inside with out
nails and using epoxy resin base adhesive as per manufacturers
reccomendations and the colour of the marker should be as per the
IRC 35- 2015 and as directd by engineer - in - charge.
59 Providing and fixing pre-cast Rubber Dye inter locking concrete block
60mm thick with grade of concrete M250 pnumatic compressed by
mechanically pressed and as per approved design including 75mm As per attached
Sand layer for levelling and filling the joint with sand in proper line and seprate sheet
level etc complete.For R.E. wall Protection
Specification Index
Item Applicable
ITEM DESCRIPTION
No. specification reference
60 Providing and fixing marbal slab including engraving and painting As per attached
complete.(i) Size 75cm x 60cm x 4cm. seprate sheet