0% found this document useful (0 votes)
126 views

SPARC S7 Architecture and Common Compone

The document provides information about the SPARC S7-2 server through a series of multiple choice questions. It tests knowledge about the server's components, specifications, and configurations. Specifically, it asks about which button resets the Service Processor, that the server supports 1 or 2 processors, and that the "dash two" in the product name represents the maximum number of processor chips.

Uploaded by

ElvÏs ElvÏs
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views

SPARC S7 Architecture and Common Compone

The document provides information about the SPARC S7-2 server through a series of multiple choice questions. It tests knowledge about the server's components, specifications, and configurations. Specifically, it asks about which button resets the Service Processor, that the server supports 1 or 2 processors, and that the "dash two" in the product name represents the maximum number of processor chips.

Uploaded by

ElvÏs ElvÏs
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 11

1.

 Which
button  Question à revoir 
can be (1) Points
used to
reset the
Service
Processor
in the
SPARC
S7-2?

Locate Button
Reset Button
SP Reset Button (*)
Power OK button

Correct!

2.  How many cores does the S7 processor support?


 Question à revoir 
(1) Points

4
32
16
8 (*)

Correct!

3.  A customer has asked to have his SPARC S7-2 Server with one processor
upgraded to two processors. Your response is?  Question à revoir 
(1) Points

The SPARC S7-2 with one processor cannot be upgraded to two


processors (*)
Open a service request for the upgrade
I will schedule the upgrade for you
I am not familiar with the upgrade procedure

Correct!

4.  What is the height of the SPARC S7-2 Server?


 Question à revoir 
(1) Points

2U
4U
1U (*)
3U

Incorrect. Please refer to the “SPARC S7-2


Server Architecture” course for more
information.

5.  Which components are cold service FRUs in the SPARC S7-2?
 Question à revoir 
(1) Points

Fan Modules, Power Supplies


DIMMS PCIe Cards
Motherboard, Disk Backplane (*)

Correct!

6. What
does the  Question à revoir 
“dash (1) Points
two” (-2)
represent
in the
SPARC
S7-2
product
name?

The maximum number of processor chips in the server (*)


The minimum number of cores in each processor chip
The height of the server
The number of PCIe slots supported

Correct!

7.  How many internal GbE ports controlled by Solaris are on the rear of the
SPARC S7-2 servers?  Question à revoir 
(1) Points

Two 1GbE port and Two 10GbE ports


Four 1GbE ports only
One 1GbE port and Four 10GbE ports
Four 10GbE ports only (*)

Correct!

8.  How many memory slots are there in a SPARC S7-2 with 1 processor?
 Question à revoir 
(1) Points

8 (*)
6
16
32

Correct!
9.  How many of the chassis disk slots support SAS HDDs / SSDs in the SPARC
S7-2?  Question à revoir 
(1) Points

8 (*)
2
4
6

Correct!

10.  How many PCIe switches are supported in the SPARC S7-2 servers?
 Question à revoir 
(1) Points

3
2 (*)
4
1

Correct!

11. Which
internal  Question à revoir 
PCIe (1) Points
slot
houses
the HBA
that
supports
the
SPARC
S7-2
chassis
disks?

Slot 7
Slot4 (*)
Slot1
Slot2

Incorrect. Please refer to the “SPARC S7-2


Server Architecture” course for more
information.

12.  How many processors does the SPARC S7-2 Server support?
 Question à revoir 
(1) Points

1 or 2 (*)
5 or 6
3 or 4
2 or 3

Correct!

SPARC S7-2L Server Architecture


This assessment tests the participant's knowledge of the content in Oracle’s SPARC S7-2L Server Architecture
course. 
(Répondez à toutes les questions de cette section.)

13.  How many memory slots are there in a SPARC S7-2L?


 Question à revoir 
(1) Points

8
16 (*)
6
32

Correct!!

14.  What combination of disks is available in the SL7-2L DBP12?


 Question à revoir 
(1) Points

12x SFF SAS HDDs / SSDs + 2x Rear SFF HDDs or 8x SFF SAS HDDs /
SSDs and 4x SFF NVMe SSDs + 2x Rear SFF HDDs
12x 3.5” LFF + 2x Rear SFF HDDs (*)
12x SFF NVME SSDs
12x 2.5” SFF SAS HDDs / SSDs, or 8x 2.5” SFF SAS HDDs / SSDs and
4x SFF NVME SSDs

Correct!!

15.  The SPARC S7-2L has four different disk configurations, which are the
correct configurations?  Question à revoir 
(1) Points

DBP8, DBP24, DBP36, DBP12-NVME


DBP8, DBP24, DBP12, DBP12-NVME (*)
DBP8, DBP16, DBP32, DBP8-NVMe
DBP8, DBP12, DBP24, DBP8-NVME

Correct!!

16. What
combination  Question à
of disks is revoir 
available in (1) Points
the S7-2L
DBP8?
8x SFF SAS HDDs / SSDs + 2x Rear SFF HDDs or 4x SFF SAS HDDs
/ SSDs and 4x SFF NVMe SSDs + 2x Rear SFF HDDs
8x SFF NVME SSDs
8x 3.5” LFF + 2x Rear SFF HDDs
8x 2.5” SFF SAS HDDs / SSDs, or 4x 2.5” SFF SAS HDDs / SSDs and
4x SFF NVME SSDs (*)

Correct!!

17.  Which components are hot service CRUs in the SPARC S7-2L?
 Question à revoir 
(1) Points

DIMMS PCIe Cards


Motherboard, Disk Backplane
Fan Modules, Power Supplies (*)

Correct!!

18.  What is the height of the SPARC S7-2L?


 Question à revoir 
(1) Points

1U
2U (*)
4U
3U

Correct!!

19.  What combination of disks is available in the SL7-2L DBP24?


 Question à revoir 
(1) Points

24x SFF SAS HDDs / SSDs + 2x Rear SFF HDDs or 20x SFF SAS
HDDs / SSDs and 4x SFF NVMe SSDs + 2x Rear SFF HDDs (*)
24x SFF NVME SSDs
24x 2.5” SFF SAS HDDs / SSDs, or 20x 2.5” SFF SAS HDDs / SSDs
and 4x SFF NVME SSDs
24x 3.5” LFF + 2x Rear SFF HDDs

Correct!!

20.  What combination of disks is available in the SL7-2L DBP12-NVMe


 Question à revoir 
(1) Points

12x SFF SAS HDDs / SSDs + 2x Rear SFF HDDs or 8x SFF SAS
HDDs / SSDs and 4x SFF NVMe SSDs + 2x Rear SFF HDDs
12x 3.5” LFF + 2x Rear SFF HDDs
12 2.5” SFF SAS HDDs / SSDs, or 8x 2.5” SFF SAS HDDs / SSDs
and 4x SFF NVME SSDs
12x SFF NVME SSDs (*)
Correct!!

21. Which
internal  Question à revoir 
PCIe (1) Points
slot
houses
the HBA
that
supports
the
SPARC
S7-2L
chassis
disks?

Slot 4
Slot 1
Slot 2
Slot 7 (*)

Correct!!

22.  How many internal GbE ports controlled by Solaris are on the rear of the
SPARC S7-2L servers?  Question à revoir 
(1) Points

Four 1GbE ports only


Two 1GbE port and Two 10GbE ports
Four 10GbE ports only (*)
One 1GbE port and Four 10GbE ports

Correct!!

23.  How many processors does the SPARC S7-2L support?


 Question à revoir 
(1) Points

3
1
2 (*)
4

Correct!!

24.  If the SPARC S7-2L has its service required indicator lit, what other
indicators can assist in isolating a suspected cooling problem?  Question à revoir 
(1) Points

Power Supply indicator


Power OK indicator
Fan and Overtemp indicators (*)
Service Processor indicator

Correct!!

SPARC S7 Server Common Components


This assessment tests the participant's knowledge of the content in Oracle’s SPARC S7 Common Components
course. 
(Répondez à toutes les questions de cette section.)

25.  How many fans can fail in a SPARC S7 server fan module and still guarantee
the server will continue to operate?  Question à revoir 
(1) Points

One fan (*)


None
Two fans

Correct!!

26. How
many  Question à revoir 
NVMe (1) Points
drives
can
most of
the S7
servers
support?

Two NVMe drives


Six NVMe drives
Four NVMe drives (*)

Incorrect. Please refer to the “SPARC S7


Common Components” course for more
information.

27.  Which of the following can be checked using the nvmeadm command on a
SPARC S7 server?  Question à revoir 
(1) Points

(Choisir toutes les réponses correctes)

Drive health (*)


Error logs (*)
Network throughput
Data center power usage
Drive temperature (*)
SMART data (*)
Correct!!

28.  How many DIMMs are in a half populated 1 socket S7-2 and 1 socket Netra
S7-2?  Question à revoir 
(1) Points

Four DIMMs (*)


Eight DIMMs
Sixteen DIMMS

Correct!!

29.  How many fan modules are present in the 1 socket SPARC S7-2?
 Question à revoir 
(1) Points

Two fan modules


Three fan modules (*)
Four fan modules
Five fan modules

Incorrect. Please refer to the “SPARC S7


Common Components” course for more
information.

30.  How many fan modules are present in the 2 socket SPARC S7-2 and SPARC
S7-2L?  Question à revoir 
(1) Points

Two fan modules


Three fan modules
Five fan modules
Four fan modules (*)

Correct!!

31. The
SPARC  Question à revoir 
S7-2L (1) Points
server
and the 1
or 2
socket
Netra S7-
2 servers
operate
on which
of the
following?

100-120 Vac and 200-240 Vac


100-120 Vac
200 to 240 Vac (*)

Incorrect. Please refer to the “SPARC S7


Common Components” course for more
information.

Netra S7-2 Server Architecture


This assessment tests the participant's knowledge of the content in Oracle’s Netra S7-1 Server Architecture
course. 
(Répondez à toutes les questions de cette section.)

32. 
What is the height of the Netra S7-2?  Question à revoir 
(1) Points

4U
2U (*)
3U
1U

Correct!!

33.  How many of the chassis disk slots support SAS HDDs/SSDs in the Netra
S7-2?  Question à revoir 
(1) Points

6
4
8 (*)
2

Correct

34.  How many processors does the Netra S7-2 support?


 Question à revoir 
(1) Points

3 or 4
2 or 3
1 or 2 (*)
5 or 6

Correct!!

35.  How many USB ports are on the Netra S7-2?


 Question à revoir 
(1) Points

4 rear
2 front and 2 rear
4 front
2 front and 1 rear (*)

Incorrect. Please refer to the “Netra S7-2


Architecture” course for more information.

36. 
Which  Question à revoir 
is the (1) Points
function
of the
locator
button?

Make the locator beep sound so that the server can be located in a
datacenter
Make the white locater LED flash so that the server can be located in a
datacenter (*)
Light up the power OK LED of the server so it can be located in a
datacenter
Light up the front faceplate of the server so it can be located in a
datacenter

Incorrect. Please refer to the “Netra S7-2


Architecture” course for more information.

37.  A customer has asked to have his Netra S7-2 with one processor upgraded
to two processors. Your response is?  Question à revoir 
(1) Points

The Netra S7-2 with one processor cannot be upgraded to two


processors (*)
Open a service request for the upgrade
I will schedule the upgrade for you
I am not familiar with the upgrade procedure

Incorrect. Please refer to the “Netra S7-2


Architecture” course for more information.

38.  Which Netra S7-2 Front Panel Telco indicator is not only controlled by the
customer’s application, but also by Solaris?  Question à revoir 
(1) Points

Major
None
Critical (*)
All

Incorrect. Please refer to the “Netra S7-2


Architecture” course for more information.

39.  What are the four physical HDD/SDD drive slots that also support NVMe
SSDs in the Netra S7-2?  Question à revoir 
(1) Points
Slots 4, 5, 6 and 7
Slots 0, 1, 6 and 7
Slots 2, 3, 4 and 5
Slots 0, 1, 2 and 3 (*)

Correct!!

40.  Which components are cold service CRUs in the Netra S7-2?
 Question à revoir 
(1) Points

Fan Modules, PCIe Cards (*)


Power Supplies
Motherboard, Disk Backplane

Incorrect. Please refer to the “Netra S7-2


Architecture” course for more information.

You might also like