0% found this document useful (0 votes)
65 views

Hust CNC Controller Delta A. Hmi Factory Settings: Appendix B Communication - Scredit Software User Manual

This document defines the communication settings and register definitions for the HUST CNC controller. It provides: 1) The default baud rate, station number, and control/state areas for the HMI connection. 2) The register formats and read/write ranges for word, double word, bit, input, output, counter, and analog registers. 3) The pinout connections for the RS-232 port showing transmit and receive lines between the controller and DOP series unit.

Uploaded by

ryo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views

Hust CNC Controller Delta A. Hmi Factory Settings: Appendix B Communication - Scredit Software User Manual

This document defines the communication settings and register definitions for the HUST CNC controller. It provides: 1) The default baud rate, station number, and control/state areas for the HMI connection. 2) The register formats and read/write ranges for word, double word, bit, input, output, counter, and analog registers. 3) The pinout connections for the RS-232 port showing transmit and receive lines between the controller and DOP series unit.

Uploaded by

ryo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Appendix B Communication|ScrEdit Software User Manual

HUST CNC Controller DELTA

A. HMI factory settings

Baud rate: 9600, 7, EVEN, 2.

Controller station number: 0.

Control area/state area: W0 / W10.

B. Definition of controller Read/Write address

Registers

Read/Write Range
Register Type Format Data Length
Word No. Bit No.

Word Register Wn n: 0 ~ 13500 N/A Word


Double Word Register Dn n: 0 ~ 13500 N/A Double Word

NOTE

1) The unit for Hust CNC controller is D Word and Wn is the low word of Dn.

Contacts

Read/Write range
Contact Type Format
Word No. Bit No.
BIT_DEVICE_B Bm.n m: 0 ~ 13500 n: 0 ~ 31
BIT_DEVICE_I In N/A n: 0 ~ 255 (8 DW)
BIT_DEVICE_O On N/A n: 0 ~ 255 (8 DW)
BIT_DEVICE_C Cn N/A n: 0 ~ 255 (8 DW)
BIT_DEVICE_S Sn N/A n: 0 ~ 255 (8 DW)
BIT_DEVICE_A An N/A n: 0 ~ 1023 (32 DW)

C. Connections (Connector Pinouts)

RS-232

DOP Series Controller Controller


9 pin D-SUB male 9 pin D-SUB male 9 pin D-SUB male
(RS-232) (RS-232) (RS-232)
RXD (2) (2) TXD

TXD (3) (3) RXD


GND (5) (5) SG
(8) RTS
Top View
(7) CTS

B-28 Revision 05/30/2006, EH00