0% found this document useful (0 votes)
56 views

HF-525plus Product Data

The document provides product data and specifications for the HF-525plus radiographic system from Econet Medical. It describes the key features and components of the system including the table, bucky, generator, and optional wall stand component. The system is designed for general radiographic exams and provides ergonomic operation and high image quality.

Uploaded by

abdulla alsurabi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views

HF-525plus Product Data

The document provides product data and specifications for the HF-525plus radiographic system from Econet Medical. It describes the key features and components of the system including the table, bucky, generator, and optional wall stand component. The system is designed for general radiographic exams and provides ergonomic operation and high image quality.

Uploaded by

abdulla alsurabi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

General Purpose of Radiographic System Econet Medical CO.,LTD.

HF-525plus Radiographic System Product Data


Product Data file : ERN60731
Fit for purpose, Easy to use.

HF-525plus is a compact, cost-


efficient radiography workplace based
on a cassette catapult bucky. As a
reliable, easy-to-use solution, HF-
525plus is especially suited for all
acquisitions of skeletal radiography of
the recumbent and seated patient:

z Orthopedic diagnostics
z Trauma, routine and ER
diagnostics
z Thorax diagnostics

The simple-to-use system minimizes


training time, allows efficient workflow
and speeds up your patient
throughput.

HF-525plus consists of a patient table


with floating tabletop, a catapult
Bucky and an integrated tube support
with tube assembly and collimator. It
is prepared for use with film-cassette
or phosphor storage acquisition
systems.

The floating tabletop provides transverse movements of ± 13 cm and longitudinal movements of 58 cm (one end to the other) with a fixed table height of 68
cm. Obese patients are imaged with ease, with a high table weight capacity of up to 200 kg (450 Ibs).

The tube assembly stand is integrated into the system with tube assembly and collimator for vertical, oblique, horizontal and lateral acquisitions. The high-
frequency X-ray generator works with multi-pulse waveform. This enables high data accuracy, precise reproducibility, and short exposure times.
The combination with the optional Bucky wall stand broadens the wide application spectrum of the HF-525plus. The catapult Bucky is equipped with an
oscillating grid for high image quality and provides height adjustment for convenient system handling. Of course the workplace features automatic exposure
control.

Thanks to its ergonomic design and operator friendly controls, the system is very easy to use. HF-525plus minimizes training efforts and keeps your patient
throughput flowing.

Patients up to 190cm (75 inches) in body height can be imaged from head to toe without repositioning. The high table weight capacity of up to 200kg allows
convenient patient positioning for patients of all sizes. The cassette tray with single-handed operation is suitable for right-hand or left-hand loading with
cassette centering to optimize image quality. The tube can be rotated for cross-table exposures while chest radiography can be easily performed on a Wall
Bucky stand.

HF-525plus offers high quality for limited budgets. The high quality system from Econet Medical offers good value with its feature-rich operations and wide
clinical imaging applications.

The integration of its generator into the table requires minimal room space and also facilitates and accelerates the installation. Therefore the system is
specifically designed to provide a high degree of flexibility even in small rooms. HF-525plus is a cost-efficient, all-in-one X-ray room solution – one with the
potential to bring new momentum into your daily medical imaging business.

Strong performance through the Compact features…

Combining years of experience with innovative design and reliable technology, the HF-525plus sets new standards in radiography. This system is a secure
investment for the future, providing optimal ease of use and cost-effective solutions for the modern hospital or private practice.

ƒ All routine exposures with patients lying on the table, sitting or standing
ƒ Optimal image quality at the lowest possible dose
ƒ Easy, ergonomic one-hand operation of the entire system
ƒ High patient throughput with minimal staff requirements
ƒ Patient weight up to 150 kg, unrestricted; 227kg with restricted positioning of the tabletop and cassette tray
General Purpose of Radiographic System Econet Medical CO.,LTD.

Specifications
Bucky Table Collimator
Collimator type: Manual (Multi-layer, square field X-
Table top dimensions : 200cm X 73cm ray collimator, 6 pairs of lead-lined
shutters)
Height from floor : 68cm Field lamp: 100W, 24VAC
Table top composition : Laminated structure Lighting timer : Less than 30 sec
Table top-to-film distance: 7.8cm Average luminosity: Over 100 lx
Table top Al. equivalence : <0.8mm Al at 100kVp Alignment light: Lamp
Inherent filteration: 1.5mm aluminum
Table top weight limit : 200kg
Retractable measuring tape
Table top movement : Manual. 4-way floating top
Longitudinal travel : ± 29cm Wall Bucky Stand
Transverse table top travel 26cm Standard type: Non-tilting Bucky
Table locks : Electromagnetic brakes Bucky: Super speed
Full-length foot switch along table Vertical Bucky travel : 165cm (from 5 to 170cm)
Table lock controls:
base
Table bucky: Super speed Vertical movement : Manual, fully counterbalanced
Bucky travel 48cm Minimum distance: 40cm
Total center-to-center Cassette sizes: Up to 17 x 17 inch
Radiographic coverage : 161cm
Oscillating Grid: 40 lines/cm, 8:1 line ratio focused at
Grid 40 lines/cm, 8:1 line ratio
129cm
Cassette size : 10 X 10 ~ 17 x 17 inch Bucky front Al. equivalence: <1mm at 100 kVp
Option (Elevating table: 6-way floating) Locks: Electromagnetic brakes
Table top to floor: Variable from 40 to 87cm Left or Right load weight: 145kg
Longitudinal travel: 80cm
Table top up/down Central foot switched along table
Optional items
movement : base
AEC controller in HFG
AEC ion chambers
Automatic Exposure Control
(upto 2 chambers) –
single field or three field.
Floor-to-Mounted Tube stand High Speed Rotor Only available from 700mA
Manual movement, with fully
Design : counter balanced horizontal tube Ceiling suspension
arm
Longitudinal tube travel: 175cm Uninterruptible Power Supply Enabling to use normal AC power
Transverse tube travel: 30cm, with detent at table center
Vertical tube travel: 124cm Standard accessories
Focal spot-to-floor Hand Switch (with a holder)
Variable from 40 to 202cm OP manual
distance:
Service manual
X-ray tube rotation: +/- 180° (detents at +90° ~ -90°)
HV cable gel
Tube stand column rotation: +/- 180° (detents at +90° ~ -90°)
Locks: Electromagnetic brakes
Longitudinal, transverse, vertical, 10:1 or 12:1 grid into the bucky
X-ray protector cloths
Tube arm console controls: and rotational lock control
Optional accessories Compression band
buttons Hand grip
SID and tube angle around
Tube arm console displays:
horizontal axis

X-ray tube
Model Maker Heating Unit Focal spot Max current & voltage Target angle
E7239X Toshiba (Japan) 140kHU 1.0/2.0mm 500mA/125kV 16°
E7252X Toshiba (Japan) 300kHU 0.6/1.2mm 1000mA/150kV 12°
Rad 14 Varian (USA) 300kHU 0.6/1.2mm 1000mA/150kV 12°

* More detailed information can be found in the product data sheet from each maker.
General Purpose of Radiographic System Econet Medical CO.,LTD.

High Frequency X-ray Generators


SPECIFICATIONS
Power Ratings of Constant Potential 30kW 40kW 50kW
Radiographic kV range in 1 kV steps 40 – 125kV (1kV step) 40 - 125kV (1kV step) 40 - 125kV/150kV(1kV step)
Accuracy ± 3% ± 3% ± 3%
mA Range and Stations 50, 75, 100, 150, 200, 250, 300 50, 75, 100, 150, 200, 250, 300, 50, 75, 100, 150, 200, 250, 300,
400, 500 400, 500, 600, 700
Accuracy (± 3%) (± 3%) (± 3%)
Power Output 300mA @ 100kV 500mA @ 80kV 700mA @ 70kV
200mA @ 125kV 300mA @ 125kV 500mA @ 100kV
300mA @ 150kV
Exposure Time Range 0.01 – 6 seconds (81 steps) 0.01 – 6 seconds (81 steps) 0.01 – 6 seconds (81 steps)
Accuracy ± 2% ± 2% ± 2%
mAs Range 0.5 – 500 mAs 0.5 – 500 mAs 0.5 – 600 mAs
High Voltage Ripple (TYP) <1 kV @100kV <1 kV @100kV <1 kV @100kV
Automatic Exposure Control
Optional
(upto 2 chambers)
Buckys (2 standard) Standard
Anatomical Program Standard (288)
Uninterruptible Power Supply (*) Optional
(*)Uninterruptible Power Supply option – Line Power Requirement is 500W

3 Point Operation Console Standard


Line Voltage Range and Phase 220 – 230VAC 50/60Hz Single Phase
Automatic Line Compensation ± 15% ± 15% ± 15%
Dimensions (mm) 590 * 600 * 440mm 590 * 600 * 440mm 590 * 600 * 440mm
Weight (Kg) 110KG 120KG 130KG
General Purpose of Radiographic System Econet Medical CO.,LTD.

Overall dimensions
General Purpose of Radiographic System Econet Medical CO.,LTD.

Room dimension (recommended)

Econet Medical Co.LTD


B-715, SK Twintech Tower, 345-9, Gasan dong, Geumcheon gu, Seoul, Korea 153-773
Tel)+82 2 62922780 Fax)+82 2 62922785
email to [email protected] Visit us at www.econetmedical.com

You might also like