Automatic Hand Dryer: May Lwin Thant Khine Myint Mon, Khin Thandar Tun
Automatic Hand Dryer: May Lwin Thant Khine Myint Mon, Khin Thandar Tun
1.INTRODUCTION
2.FUNDAMENTALS OF COMPONENTS
Figure 2. Symbol of Relay
2.1. Light Sensor ( Photo-resistor)
The 555 timer can be configured in three difference 4.OPERATION OF CIRCUIT DIAGRAM
mode: astable, monostable and bistable mode. In
monostable mode, an external resistor and capacitor
connected are used to set up the 555 timer as a
nonretriggerable one-shot. The pulse width is determine Heating fan
by the time constant of R and C. coil
+5 V
Hot air
RLDR 4 8 RVR
50 kΩ
6
555 Timer 5 V Relay NC
Laser
IC 3
module
2 COM
7
1 5 LN 4007 NO AC
Figure 4. Pin Layout of 555 Timer IC R1 220 V
100 kΩ C1 C2
10 nF 100 µF
and fan.
VCC = 5 V
4 8 VR The value from measuring,
50 kΩ RLDR = 0.86 MΩ
6
555 Timer 𝑅1
IC 3 The voltage of the pin 2, V2 = ×VCC Equation
𝑅1+𝑅𝐿𝐷𝑅
2 7 (2)
1 5
100 𝑘
C2 = ×5
100 µF
100 𝑘+0.86 𝑀
= 0.53 V
Figure 8. Part of VR and C2
The V2 = 0.53 V is less than 1/3 VCC, therefore the output
In 555 timer monostable mode, voltage is high.
Delaytime,tw=1.1RC Equation The output voltage at pin 3 from measuring
(1) Vout = 2.7 V
For VR(min) = 0 kΩ,
Minimum delay time, tw (min) = 1.1VR(min)C2
= 1.1×0 ×100 µ 7.TEST AND RESULTS OF AUTOMATIC HAND
=0s DRYER
For VR(max) = 50 kΩ,
Maximum delay time, tw (max) = 1.1VR(max)C2
= 1.1×50 k×100 µ
= 5.5 s
Let VR = 45 kΩ,
The delay time of automatic hand dryer after the hand is
passed,
Delay time of hand dryer, tw = 1.1VRC2
= 1.1×45 k×100 µ
= 4.95 s