0% found this document useful (0 votes)
214 views1 page

Deck Slab Reinforcement Details: Nagpur Metro Rail Project

The document appears to be an engineering drawing containing details for deck slab reinforcement. It includes labeling of various sections A through J and notes that the drawing has been proof checked and reviewed for its design and detailing and found suitable for construction. Reference drawings are also listed. The drawing contains dimensions, labels, and technical information about reinforcement bars, locations, and elevations.

Uploaded by

Nagpur Metro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
214 views1 page

Deck Slab Reinforcement Details: Nagpur Metro Rail Project

The document appears to be an engineering drawing containing details for deck slab reinforcement. It includes labeling of various sections A through J and notes that the drawing has been proof checked and reviewed for its design and detailing and found suitable for construction. Reference drawings are also listed. The drawing contains dimensions, labels, and technical information about reinforcement bars, locations, and elevations.

Uploaded by

Nagpur Metro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A A

B ON HOLD B
F
T12@100c/c
T12@100c/c

C C
T12@100c/c T12@100c/c
T12@100c/c
T12@100c/c
TOC +327.35M C

B T12@100c/c ON HOLD E D
D T12@100c/c T12@100c/c D
T12@100c/c TOC +327.35M TOC +327.35M
A

E E

TOC +327.05M TOC +327.05M TOC +327.05M

T12@100c/c
T12@100c/c
F F

T16@100c/c A T12@100c/c T16@100c/c

T16@100c/c T12@100c/c T12@100c/c TOC +327.35M TOC +327.35M T16@100c/c


T12@100c/c T12@100c/c
B T12@100c/c E D
G
ON HOLD
TOC +327.35M C T12@100c/c
T12@100c/c
T12@100c/c T12@100c/c

T12@100c/c

T12@100c/c
F
ON HOLD
I
DECK SLAB REINFORCEMENT DETAILS

J
LEGEND:-

REFERENCE DRAWINGS:-
MNM01-MM-CV-PRM-HIN_MD-DRP-0011A CONSTRUCTION REFERENCE DRAWINGS
NOTES :- THIS DRAWING INCLUDING ITS DESIGN AND DETAILING HAS
BEEN PROOF CHECKED/REVIEWED AND FOUND SUITABLE FOR
COUNTER SIGNED BY
MAHARASHTRA METRO
PROJECT: NAGPUR METRO RAIL PROJECT
1. CONCRETE GRADE SHALL BE M35. THE EXECUTION PURPOSE AND ISSUED AS `GOOD FOR RAIL CORPORATION LTD. Metro House, 28/2, CK Naidu Marg, Anand Nagar,
K 2. REINFORCEMENT SHALL BE OF GRADE Fe 500-D CONFORMING TO IS:1786-2008. CONSTRUCTION'/BEING GIVEN NO OBJECTION Civil Lines, Nagpur - 440 001 K
3. CLEAR COVER TO ANY REINFORCEMENT SHALL BE 25mm UNLESS NOTED OTHERWISE. Phone No: 07122554217
4. MINIMUM LAP LENGTH SHALL BE 46xd WHERE `d' IS THE DIAMETER OF SMALLER BAR.
GENERAL CONSULTANT TO NMRP
5. NOT MORE THAN 50 % BARS SHALL BE LAPPED AT ONE SECTION. LAP LENGTH SIGN:
CLIENT: MAHARASHTRA METRO RAIL CORPORATION LTD.
SHALL BE EQUAL TO 46 TIMES OF THE BAR. LAPS SHALL BE SUITABLY STAGGERED
AND MINIMUM C/C DISTANCE BETWEEN ADJACENT LAPS SHALL BE 1.3 TIME LAP DATE: LOCATION: METRO NEO
LENGTH.
NAME:
6. LIVE LOAD CONSIDERED IN DESIGN IS 4kN/m 2
7. DIAMETER OF HOLDING DOWN 'U' BOLTS = 28MM
TITLE: DECK SLAB REINFORCEMENT DETAILS (SHEET-1)
L L
8. MATERIAL OF HOLDING DOWN BOLTS = GRADE 8.8/YIELD STRESS 640 HIGH TENSILE STEEL
(confirming to IS:1367-Part-3) SYSTRA-AECOM-EGIS-RITES SCALE: N.T.S. DATE: 07.06.2021 STATUS: CRD REVISION NO:
Church House, Above SBI Bank, DRG NO:
B01 07.06.2021 FIRST ISSUE
DATE DESCRIPTION
First floor, Civil Lines Nagpur- 440001 MNM01-MM-CV-PRM-HIN_MD-DRP-0011 B01
REV NO SIGN
1 2 3 4 5 6 7 8 9 10 11 12 plot scale
15 16
TBA 50mm