Virgin Hyperloop ECB Design
Virgin Hyperloop ECB Design
Linear Motor & Eddy Current Brake Design For The Worlds First
Hyperloop Test Track
Abstract :
Last year, the first full scale hyperloop test track, DevLoop, was successfully built and
tested in Apex, Nevada. By the end of 2017, a peak speed of 240mph (387kph) has been
reached on a track length of only 500 meters.
One of the many challenges was to design a linear motor that could take the pod to such a
speed in a short distance and later to design a fail-safe braking system, that brings the pod
to a complete stop on less than 200 meters of track.
This presentation will give insight into the hyperloop system and the design and analysis of
the DevLoop linear motor and the eddy current braking system.
24 - 1
December 5-6, 2018 JMAG Users Conference 2018
Dr Arbi G. Siraki
S r. M a n a g e r P ro p u l s i o n S y st e m s
1 © 2018 Virgin Hyperloop One Inc. All rights reserved. Confidential – Not for Distribution
OUR VISION
24 - 2
December 5-6, 2018 JMAG Users Conference 2018
PA S S E N G E R | C A R G O
LOW-PRESSURE
TUBE
ELECTRO-MAGNETIC
PROPULSION
AUTONOMOUS CONTROL
P L AT F O R M
300 m/s
1080 km/h
670 mph
Road – 4+ hours
R
A B
500 km | 310 miles
24 - 3
December 5-6, 2018 JMAG Users Conference 2018
Commute
Zone
A B
Regional
Airport
Centre
Suburban Area
500 km
Commute
Zone
A B
Regional
Airport
Centre
Suburban Area
500 km
Radically Efficient
100% ELECTRIC,
ZERO EMISSIONS
24 - 4
December 5-6, 2018 JMAG Users Conference 2018
XP-1
NORTH LAS VEGAS, NEVADA
First Hyperloop
One vehicle
DEVLOOP
NORTH LAS VEGAS, NEVADA
World’s first
full scale
Hyperloop
P H A S E 3 T EST S
DEC 14, 2017
24 - 5
December 5-6, 2018 JMAG Users Conference 2018
Desi gn Highlights
¾ Initial Target: Reach 300m/s within 2km distance (2.3g of acceleration)
¾ Designed for full system proof of concept not carrying passengers
¾ Motor design can be simply modified for lower accelerations ( around 0.25g ) for carrying passengers
300m 200m
Acceleration Deceleration
With LPMSM With Eddy current brake
24 - 6
December 5-6, 2018 JMAG Users Conference 2018
Rotor Design
¾ PM synchronous motor topology was selected.
Double sided PM rotor was proposed for maximum flux generation.
¾ Embedded magnet options not considered due to large air gap and pole pitch.
17 © 2018 Virgin Hyperloop One Inc. All rights reserved.
14,000
12,000
10,000
Force [N]
8,000
6,000
4,000
2,000
0
50 100 150 200 250
Gap Between Arrays [mm]
24 - 7
December 5-6, 2018 JMAG Users Conference 2018
Motivation:
¾ Shorter end winding thus lower copper losses and lower end-
winding contribution to total inductance
¾ Ease of manufacturing
Design Spec:
¾ A design with 1 coil/pole/phase (q=0.5) is considered
¾ No subharmonics
¾ Theoretical winding factor of ܭ௪ ൌ ͲǤͺ
ܹ݃݊݅݀݊݅ ݀݁ݐܽݎݐ݁݊݁ܿ݊ܥ
ܭ௪ ൌ ൌ ͲǤ
ܹ݃݊݅݀݊݅ ݀݁ݐݑܾ݅ݐݏ݅ܦ
24 - 8
December 5-6, 2018 JMAG Users Conference 2018
24 - 9
December 5-6, 2018 JMAG Users Conference 2018
• Aluminum
• Copper
• Ferromagnetic Steel
• Stainless Steel
3m 90m 3m 80m
24 - 10
December 5-6, 2018 JMAG Users Conference 2018
Brackets
Ferromagnetic carbon steel
Attaching rail to tube
Test Results
Deceleration profile of high speed run
Final part of
acceleration
Transition from
acceleration to braking
1.5g -> -4g)
(1
24 - 11
December 5-6, 2018 JMAG Users Conference 2018
• Excellent agreement
between JMAG FEA and
measurement
• Error <3.3% across full
operating range
2018 Focus
S t ro n g G o ve r n m e n t - S p o n s o re d P ro j e c t s G l o b a l l y
UNITED ARAB
E M I R AT E S INDIA
USA
24 - 12
December 5-6, 2018 JMAG Users Conference 2018
Questions?
W W W. H Y P E R LO O P - O N E .CO M
@ H Y P E R LO O P O N E
24 - 13