Design of Anchor For Curb Inlet Filter
Design of Anchor For Curb Inlet Filter
ANALYSIS
EFFECTIVE AREA OF FASTENER Ase = 0.032 in2
BEARING AREA OF HEAD Ab = 0.117 in2, ( or determined from manufactures's catalogs.)
CHECK FASTENER TENSILE STRENGTH :
where : = 0.9
CHECK CONCRETE BREAKOUT STRENGTH :
ANo
N cb A N 2 3N b A N2 0.7
0.3c
3 24 f c he f
9h ef
' 1.5
1.5h e f
12
= 2.091 k > Nu [Satisfactory]
where : = 0.75
3 term is 1.0 for location where concrete cracking is likely to occur.
CHECK PULLOUT STRENGTH :
N pn 4 Ab8 f 'c = 2.106 k > Nu [Satisfactory]
where : = 0.75
4 term is 1.0 for location where concrete cracking is likely to occur.
CHECK SIDE-FACE BLOWOUT STRENGTH : (Since c > 0.4hef , this type of failure mode is applicable.)
N sb 160c Ab fc
'
= 4.496 k > Nu [Satisfactory]
where : = 0.75
DETERMINE DESIGN TENSILE STRENGTH :
N n min N s , N cb , N pn , N sb = 1.382 k
where : = 0.9
CHECK CONCRETE BREAKOUT STRENGTH FOR SHEAR LOAD :
A A l 0.2
V cb V
6 7V b V
6 7 7 d '
f c c1.5
= 0.616 k > Vu [Satisfactory]
AVo AVo d
where : = 0.75
7 term is 1.0 for location where concrete cracking is likely to occur.
AV/AVo and 6 terms are 1.0 for single shear fastener not influenced by more than one free edge.
l term is load bearing length of the anchor for shear, not to exceed 8d.
(Cont'd)
CHECK PRYOUT STRENGTH FOR SHEAR LOAD :
A No
V cp k cp A N 2 3 N b k cp A N2 0.7
0.3c
9h ef
3 24 f c h ef
' 1.5
1.5h ef
= 4.183 k > Vu [Satisfactory]
where : = 0.75
3 term is 1.0 for location where concrete cracking is likely to occur.
kcp = 2.0 for hef > 2.5 in.
DETERMINE DESIGN SHEAR STRENGTH :
Nu V
u 1.17 < 1.2 [Satisfactory]
N n V n