0% found this document useful (0 votes)
42 views

Design of Anchor For Curb Inlet Filter

This document summarizes the design of an anchor for a curb inlet filter. It provides input data such as a concrete strength of 3 ksi and fastener strength of 60 ksi. It then analyzes the anchor design for tension, shear, pullout, and interaction according to ACI 318-10. The analysis shows the anchor design is adequate to resist the factored loads of 0.5 k for tension and shear.

Uploaded by

Aaron Paul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views

Design of Anchor For Curb Inlet Filter

This document summarizes the design of an anchor for a curb inlet filter. It provides input data such as a concrete strength of 3 ksi and fastener strength of 60 ksi. It then analyzes the anchor design for tension, shear, pullout, and interaction according to ACI 318-10. The analysis shows the anchor design is adequate to resist the factored loads of 0.5 k for tension and shear.

Uploaded by

Aaron Paul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PROJECT PROJECT : Design of Anchor for Curb Inlet Filter PAGE :

CLIENT : Project Pink DESIGN BY : APIC


PINK JOB NO. : 001 DATE : 8/12 REVIEW BY : APIC
Single Fastener in Tension and Shear Near an Edge Based on ACI 318-10

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc ' = 3 ksi
SPECIFIED STRENGTH OF FASTENER fut = 60 ksi
(The strength of most fastenings is likely to be controlled by the embedment strength rather
than the steel strength, so it is usually economical to use ASTM A307 Grade A fastener.)
FACTORED DESIGN TENSION LOAD Nu = 0.5 k
FACTORED DESIGN SHEAR LOAD Vu = 0.5 k
EFFECTIVE EMBEDMENT DEPTH hef = 2 in
FASTENER DIAMETER d = 0.25 in [THE FASTENER DESIGN IS ADEQUATE.]
FASTENER HEAD TYPE 3 Hex
( 1=Square, 2=Heavy Square, 3=Hex, 4=Heavy Hex, 5=Hardened Washers )
DIST. BETWEEN THE FASTENER AND ED c = 2 in

ANALYSIS
EFFECTIVE AREA OF FASTENER Ase = 0.032 in2
BEARING AREA OF HEAD Ab = 0.117 in2, ( or determined from manufactures's catalogs.)
CHECK FASTENER TENSILE STRENGTH :

 N s   n Ase  0.8 f ut  = 1.382 k > Nu [Satisfactory]

where :  = 0.9
CHECK CONCRETE BREAKOUT STRENGTH :

ANo

 N cb   A N  2 3N b   A N2  0.7 
0.3c 
 3 24 f c he f
 9h  ef
' 1.5

1.5h e f 
  12
= 2.091 k > Nu [Satisfactory]
where :  = 0.75
3 term is 1.0 for location where concrete cracking is likely to occur.
CHECK PULLOUT STRENGTH :
 N pn   4  Ab8 f 'c  = 2.106 k > Nu [Satisfactory]

where :  = 0.75
4 term is 1.0 for location where concrete cracking is likely to occur.
CHECK SIDE-FACE BLOWOUT STRENGTH : (Since c > 0.4hef , this type of failure mode is applicable.)


 N sb   160c Ab fc
'
 = 4.496 k > Nu [Satisfactory]

where :  = 0.75
DETERMINE DESIGN TENSILE STRENGTH :

 N n  min  N s ,  N cb ,  N pn ,  N sb  = 1.382 k

CHECK FASTENER SHEAR STRENGTH :

V s   n0.6 Ase f ut = 1.037 k > Vu [Satisfactory]

where :  = 0.9
CHECK CONCRETE BREAKOUT STRENGTH FOR SHEAR LOAD :

A A   l  0.2 
V cb   V
 6 7V b   V
 6 7  7  d '
f c c1.5 
 = 0.616 k > Vu [Satisfactory]
AVo AVo  d 
where :  = 0.75
7 term is 1.0 for location where concrete cracking is likely to occur.
AV/AVo and 6 terms are 1.0 for single shear fastener not influenced by more than one free edge.
l term is load bearing length of the anchor for shear, not to exceed 8d.
(Cont'd)
CHECK PRYOUT STRENGTH FOR SHEAR LOAD :

A No

V cp   k cp A N  2 3 N b   k cp A N2  0.7 
0.3c 
9h  ef
 3 24 f c h ef
' 1.5

1.5h ef 
 
= 4.183 k > Vu [Satisfactory]
where :  = 0.75
3 term is 1.0 for location where concrete cracking is likely to occur.
kcp = 2.0 for hef > 2.5 in.
DETERMINE DESIGN SHEAR STRENGTH :

V n  min V s , V cb , V cp  = 0.616 k

CHECK TENSION AND SHEAR INTERACTION :


Since Nu > Nn and
Vu > Vn the full design strength is not permitted.
The interaction equation must be used

Nu V
 u  1.17 < 1.2 [Satisfactory]
 N n V n

Summary of Dimensional Properties of Fasteners


Effective
Fastener Gross Area of Bearing Area of Heads, Nuts, and Washers
Diameter Area of Threaded ( Ab ) ( in2 )
( in ) Fastener Fastener Heavy Heavy Hardened
Square Hex
( in2 ) ( in2 ) Square Hex Washers
0.250 1/4 0.049 0.032 0.142 0.201 0.117 0.167 0.258
0.375 3/8 0.110 0.078 0.280 0.362 0.164 0.299 0.408
0.500 1/2 0.196 0.142 0.464 0.569 0.291 0.467 0.690
0.625 5/8 0.307 0.226 0.693 0.822 0.454 0.671 1.046
0.750 3/4 0.442 0.334 0.824 1.121 0.654 0.911 1.252 Techincal Reference:
0.875 7/8 0.601 0.462 1.121 1.465 0.891 1.188 1.804 1. Ronald Cook, "Strength Design
1.000 1 0.785 0.606 1.465 1.855 1.163 1.501 2.356 of Anchorage to Concrete," PCA,
1.125 1 1/8 0.994 0.763 1.854 2.291 1.472 1.851 2.982 1999.
1.250 1 1/4 1.227 0.969 2.288 2.773 1.817 2.237 3.682
1.375 1 3/8 1.485 1.160 2.769 3.300 2.199 2.659 4.455
1.500 1 1/2 1.767 1.410 3.295 3.873 2.617 3.118 5.301
1.750 1 3/4 2.405 1.900 - - - 4.144 6.541
2.000 2 3.142 2.500 - - - 5.316 7.903

You might also like