THE VIBRATION MONITORING SPECIALISTS
PRODUCT INFORMATION
PCH 1106 COMPACT VIBRATION SENSOR
With optional temperature output as 4-20 mA
The vibration sensor PCH 1106 Mk2 can be used locity (mm/s), acceleration (m/s2) or displacement
on many different machines in a production envi- (mm) and measures in true RMS or Peak-Peak. Op-
ronment. It is suitable for monitoring blowers, tionally, the PCH 1106 Mk2 can be delivered with a 4-
ventilators, pumps, decanters, separators, com- 20 mA surface temperature reading in °C as well.
pressors and mills. The vibration sensor continu-
ously monitors the machine vibration level and The vibration sensor can be connected to a PLC or a
gives a DC output in relation to this. When con- machine monitoring system. Two DC outputs are
nected to a PLC or a CTS system the operator will available for vibration level as a 4-20 mA and 1-5 V
gain an active protection of the machine, which DC signal proportional to Full Scale to the PLC. Op-
limits the damages to the machine and conse- tionally, a temperature reading or a raw time wave-
quently will reduce the maintenance costs. Op- form output, 100 mV/g, can be delivered instead of the
tionally, PCH 1106 Mk2 can be delivered with a 1-5 VDC signal.
bearing temperature output measured on the bear-
ing housing or a raw time waveform output. Alarms for individual vibration levels can be pro-
grammed in the PLC or CTS system, where also a
Bearing damages preventive action can be initiated.
A bearing damage often occurs due to undetected
unbalance or misalignment of a machine. Hence, the Connecting the vibration sensor to the PLC or CTS
machine runs for a very long period of time with a far system only requires a single cable with 4 wires. The
too high vibration level. This is the most common rea- measuring and frequency ranges are pre-set by PCH,
son for serious machine crashes and down time. so the vibration sensor is ready for use at delivery.
Avoid unscheduled production stops PCH 1106 Mk2 can also be used for periodic meas-
Deciding not to invest in vibration monitoring only be- urements by connecting a portable meter, like the
cause of initial investments costs can be an unwise PCH 1033, which displays the actual vibration level at
decision. This will often lead to unexpected expenses the point of a permanently mounted PCH 1106 Mk2.
due to machine repairs, not to mentioned the further
economic losses due to a production stop.
Price attractive alternative
For users who prefer a simple protection against
damaging vibrations the PCH 1106 Mk2 is very price
attractive solution that easily can be connected to a
PLC or CTS system.
Functionality
The vibration sensor consists of a vibration sensor as
well as output electronics, which are embedded in a
stainless steel housing. The PCH 1106 Mk2 monitors
mechanical vibrations according to DIN/ISO 10816.
The PCH 1106 Mk2 can be delivered to measure ve-
VED KLÆDEBO 4 • DK-2970 HØRSHOLM • COPENHAGEN • DENMARK
TEL: +45 4576 8776 • FAX: +45 4576 8702 • E-MAIL:
[email protected] • WEB: www.pch-engineering.dk
THE VIBRATION MONITORING SPECIALISTS
Technical data
PCH 1106 COMPACT VIBRATION SENSOR
PCH 1106 Mk2 with cable PCH 1033 Vibration Meter CHA 1012 HT adaptor and isolator
Type Operating temperature: -20 °C to +70 °C
Sensor type: Capacitive accelerometer Housing (IP65): Stainless steel type 1.4305
Measuring parameter: Velocity (mm/s), Accelera- Weight: Approx 101 g
tion (m/s²), Displacement Connector: M 12, 4-pin
(mm) and °C Dimensions: Height: 66 mm, Ø 25
Measuring range: 0-10 mm/s, 0-20 mm/s and Cable (option): 1.5, 3, 5, 10 m
more, optional: Mounting: Threaded stud, M 8 mm
temperature 0-100 °C
Measuring accuracy: ±5% Ordering
Max. measuring range ± 18 g When ordering please inform about the requested
Shock 1000 g measuring range, frequency range and as an option
Frequency range: 10 Hz - 1000 Hz, 18 db/oct cable length.
(-3 dB, -60 dB/dec)
or to be agreed upon Options
Detector: True RMS Detector or Peak Surface temperature output as 4-20 mA (PCH 1106 T)
-Peak PCH 1033 Vibration meter for displaying in mm/s
Output CHA 1012 High Temperature adaptor, 90 °C radiation
2 Output signals: 4-20 mA and 1-5 V DC CHL 1073 Cable with M 12 connector, L=1500 mm
relative to 0-100 % of vi- CHL 1074 Cable with M 12 connector, L=3000 mm
bration measuring range. CHL 1075 Cable with M 12 connector, L=5000 mm
Optionally: 4-20 mA relative CHL 1088 Cable w. M12 90° connector, L = 5000 mm
to temperature 0-100 °C or CHL 1077 Cable with M 12 connector, L=10000 mm
raw time waveform output Raw time waveform signal output; contact PCH
100 mV/g, 0.1-1000 Hz
Note:
Connection PCH 1106 Mk2 replaces PCH 1102/1106 Mk1. Note that output has changed
Grounding: Ground (0 V) to housing from 1-6 V to 1-5 V output. Power supply and 4-20 mA remain unchanged.
Power supply: +24 V DC, ± 10 %,
max. 50 mA DC
PCH Engineering A/S reserves the right to change all specifications and accessories listed in this sheet without notice.
CHF 1124-UK14
VED KLÆDEBO 4 • DK-2970 HØRSHOLM • COPENHAGEN • DENMARK
TEL: +45 4576 8776 • FAX: +45 4576 8702 • E-MAIL:
[email protected] • WEB: www.pch-engineering.dk