Design For Isolated Footing 22

This document provides design details for isolated footing 22, including: 1) Geometry of the footing which is 1.5m x 1.5m x 0.25m. 2) Reinforcement details including #16 bars at 220mm centers for bottom reinforcement in the Mx and Mz directions. 3) Design calculations for the footing size based on load cases and soil properties. 4) Calculation of flexural reinforcement along the X direction to resist a critical moment of 50.108 kNm, resulting in #16 bars at 220mm centers.

Uploaded by

Jose Cacdac
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
194 views

Design For Isolated Footing 22

This document provides design details for isolated footing 22, including: 1) Geometry of the footing which is 1.5m x 1.5m x 0.25m. 2) Reinforcement details including #16 bars at 220mm centers for bottom reinforcement in the Mx and Mz directions. 3) Design calculations for the footing size based on load cases and soil properties. 4) Calculation of flexural reinforcement along the X direction to resist a critical moment of 50.108 kNm, resulting in #16 bars at 220mm centers.

Uploaded by

Jose Cacdac
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Isolated Footing Design

Isolated Footing Design(ACI 318-05)


Design For Isolated Footing 22

Footing No. Group ID Foundation Geometry


- - Length Width Thickness
22 1 1.500m 1.500m 0.250m

Footing No. Footing Reinforcement Pedestal Reinforcement


- Bottom Reinforcement(Mz) Bottom Reinforcement(Mx) Top Reinforcement(Mz) Top Reinforcement(Mx) Main Steel Trans Steel
22 #16 @ 220 mm c/c #16 @ 220 mm c/c N/A N/A N/A N/A

Isolated Footing 22

Design Calculations

Footing Size

Initial Length (Lo) = 1.500m

Initial Width (Wo) = 1.500m

Page 1 of 6
Isolated Footing Design

Reduction of force due to buoyancy = 0.000kN


Effect due to adhesion = 0.000kN
Area from initial length and width, Ao = L X W = 2.250m2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 1.988m2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 1.500 m Governing Load # 101


Case :
Width (W2) = 1.500 m Governing Load # 101
Case :
Depth (D2) = 0.250 m Governing Load # 109
Case :
Depth is governed by Ultimate Load Case
(Service check is performed with footing thickness requirements from concrete check)
Area (A2) = 2.250 m2

Final Soil Height = 1.750 m


Footing Self Weight = 13.500 kN
Gross Soil Bearing Capacity 242.00kN/m2
=
Soil Weight On Top Of
57.328 kN
Footing =

Compression Development Length Check


Development length skipped as column reinforcement is not specified in input (Column Dimnesion Task Pane)

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Page 2 of 6
Isolated Footing Design

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of
Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 109

The strength values of steel and concrete used in the formulae are in ksi

Bars parallel to X Direction are placed at bottom


Effective Depth deff= 0.167 m

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.03729

From ACI Cl. 10.3.3, = 0.02797

From ACI Cl. 7.12.2, = 0.00200

From Ref. 1, Eq. 3.8.4a, constant m = 15.629

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column 0.525 m
at a distance, Dx =

Ultimate moment, 50.108 kNm

Nominal moment capacity, Mn = 55.675 kNm

(Based on effective depth) Required


0.00504
=

(Based on gross depth) x deff / Depth = 0.00337

Since ρmin≤ ρ≤ ρmax OK

Area of Steel Required, As = 1262.013 mm2

Selected bar Size = #16


Minimum spacing allowed (Smin) = = 50.000mm

Selected spacing (S) = 222.333mm


Smin<= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318 Clause No- 10.6.4
Max spacing for Cracking Consideration = 385.642mm

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#16 @ 220.000mm o.c.

Required development length for bars = =0.305 m

Page 3 of 6
Isolated Footing Design

Available development length for bars, DL


0.450 m
=
Try bar size # 16 Area of one bar = 201.064 mm2

Number of bars required, Nbar = 7

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1407.449 mm2
deff = D - Ccover - 0.5 X (dia. of one bar) = 0.167 m

Reinforcement ratio, = 0.00562

From ACI Cl.7.6.1, minimum req'd clear distance between bars


Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 50.000mm

Provided Steel Area / Required Steel Area = 1.115

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of
Reinforced Concrete Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 109

The strength values of steel and concrete used in the formulae are in ksi

Bars parallel to X Direction are placed at bottom


Effective Depth deff= 0.151 m

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.03729

Page 4 of 6
Isolated Footing Design

From ACI Cl. 10.3.3, = 0.02797

From ACI Cl.7.12.2, = 0.00200

From Ref. 1, Eq. 3.8.4a, constant m = 15.629

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column 0.525 m
at a distance, Dz =

Ultimate moment, 47.360 kNm

Nominal moment capacity, Mn = 52.622 kNm

(Based on effective depth) Required


0.00603
=

(Based on gross depth) x deff / Depth = 0.00359

Since ρmin≤ ρ≤ ρmax OK

Area of Steel Required, As = 1347.795 mm2

Selected Bar Size = #16


Minimum spacing allowed (Smin) = 50.000mm

Selected spacing (S) = 222.333mm


Smin<= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318 Clause No- 10.6.4
Max spacing for Cracking Consideration = 385.642mm

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#16 @ 220.000mm o.c.

Required development length for bars = 0.305 m

Available development length for bars, DL


0.450 m
=
Try bar size # 16 Area of one bar = 201.064 mm2

Number of bars required, Nbar = 7

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1407.449 mm2
deff = D - Ccover - 1.5 X (dia. of one bar) 0.151 m
=

Page 5 of 6
Isolated Footing Design

Reinforcement ratio, = 0.00621

From ACI Cl.7.6.1, minimum req'd clear distance between bars


Cd = max (Diameter of one bar, 1.0" (25.4mm), Min. User Spacing) = 50.000mm

Provided Steel Area / Required Steel Area = 1.044

Check to see if width is sufficient to accomodate bars