0% found this document useful (0 votes)
629 views

10.dowtherm A Util He 1x

The document describes the Dowtherm A requirements for several process equipment units. It includes tables listing the equipment name, Dowtherm A requirement in kg/jam, inlet and outlet temperatures for each unit. It then shows a process flow diagram of the Dowtherm A distribution system including furnace, heater, reactor, and reboiler units. Calculations are provided for the furnace design including the heat load required, fuel consumption, heat transfer area and number of tubes needed to meet the duty. Specifications for a blower to supply air to the furnace are also included.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
629 views

10.dowtherm A Util He 1x

The document describes the Dowtherm A requirements for several process equipment units. It includes tables listing the equipment name, Dowtherm A requirement in kg/jam, inlet and outlet temperatures for each unit. It then shows a process flow diagram of the Dowtherm A distribution system including furnace, heater, reactor, and reboiler units. Calculations are provided for the furnace design including the heat load required, fuel consumption, heat transfer area and number of tubes needed to meet the duty. Specifications for a blower to supply air to the furnace are also included.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 47

DOWTHERM A 01 DOWTHERM A 02

14,800 Kg/jam
344.94 °C

800 Kg/jam 800 Kg/jam 15,600


344.94 °C 228.05 °C 339.7172
HEATER-02

2,100 Kg/jam 2,100 Kg/jam


REAKTOR-01
344.94 °C 202.80 °C
17,700 Kg/jam
344.94 °C

REBOILER

17,700 Kg/jam
FURNACE
325.78 °C
17,700 Kg/jam
380.00 °C
Kebutuhan Dowtherm A pada peralatan proses
Kebutuhan Dowtherm A Suhu masuk alat Suhu keluar alat
No Nama alat
(kg/jam) (°C) (°C)
1. Melter-01 2,500 258.35 142.51
2. Heater-01 3,000 258.35 70.96
3. Reaktor-01 2,100 344.94 202.80
4. Heater-02 800 344.94 228.05
5. Reboiler-01 17,700 380.00 344.94
6. Cooler-02 6,000 60.00 258.35
500 Kg/jam
15,600 Kg/jam 258.35 °C
339.7172 °C
MELTER
2,500 Kg/jam 2,500 Kg/jam
258.35 °C 142.51 °C

3,000 Kg/jam 3,000 Kg/jam


258.35 °C 70.96 °C
HEATER-01

6,000 Kg/jam
258.35 °C

6,000 Kg/jam
60.00 °C

COOLER-02
3000 Kg/jam
164.04 °C

6000 Kg/jam
120.714 °C

COOLER
UTILITAS
Lampiran Utilitas-Unit Penyedia Dowtherm AG

UNIT PENYEDIA DOWTHERM A

Kebutuhan Dowtherm A pada peralatan proses


No Nama alat Kebutuhan Dowtherm A (kg/jam) Suhu masuk alat (°C) Suhu keluar alat (°C)
1. Heater-01 7,987 140.00 74.12
2. Heater-02 6,381 240.56 108.63
3. Heater-03 7,987 300.00 140.00
4. Reboiler-01 1,846 300.00 260.00
5. Cooler-02 7,987 74.12 230.89

Untuk memenuhi kebutuhan tersebut, maka dirancang alat pendukung pada unit penyedia dowtherm A
berupa : Furnace, Blower, Tangki penyimpanan bahan bakar, Pompa, dan Cooler utilitas

FURNACE

Tugas : Memanaskan Dowtherm A dari suhu 150.35 °C menjadi 300.00 °C

Massa Dowtherm A = 9833 kg/jam = 21677.66 lb/jam


Kondisi Dowtherm A :
Suhu Masuk (t1) = 150.3500 °C = 302.63 °F
Suhu Keluar (t2) = 300.0000 °C = 572.00 °F
Suhu rata-rata (t avg) = 225.1750 °C = 437.32 °F = 498.18 K
Pada suhu rata-rata diperoleh :
Kapasitas panas (Cp) = 0.488 Btu/lb °F
Viskositas (µ) = 0.160 cP
Densitas (ρ) = 56.395 lb/ft3
Konduktifitas thermal (k) = 0.061 Btu/hr ft °F

Menentukan beban panas yang dibutuhkan (Q)


Q = Laju massa Dowtherm A (lb/jam) x Cp (Btu/lb°F) x (t2-t1) °F
= 21677.66 (lb/jam) x 0.488 (Btu/lb °F) x ( 572.00 - 302.63 ) °F
= 2847583.31 Btu/jam
Bila effisiensi pembakaran = 70%
Maka panas yang harus diberikan (Qt)
Qt = Q / Effisiensi pembakaran
= 4067976.15 Btu/jam

6
Lampiran Utilitas-Unit Penyedia Dowtherm AG

Menentukan kebutuhan bahan bakar


Fuel oil yang digunakan = Low sulfur No.6 FO, 12.6 °API (Tabel 24.6 Perry 8th ed)

Digunakan bahan bakar Fuel Oil dengan heating value = 152000 Btu/gal, (Fig. 24-1 Perry)
Qt (Btu/jam) 4067976.15 Btu/jam
Kebutuhan bahan bakar = = = 27 gallon/jam
Heating value (Btu/gal) 152000 Btu/gal

Densitas fuel oil = 8.180 lb/gal (Engineering toolbox)

7
Lampiran Utilitas-Unit Penyedia Dowtherm AG

Kebutuhan bahan bakar = 27 (gallon/jam)x 8.180 (lb/gallon)


= 218.930 lb/jam
= 99.305 kg/jam
Luas Permukaan
Fkuks Panas maksimum = 20000 Btu/jam ft2
Fluks panas yang diambil = 20000 Btu/jam ft2
Fluks panas = Q/A

Beban panas (Btu/jam) 4067976.15 Btu/jam


Luas perpindahan panas (A) = =
Fluks panas (Btu/jam ft2) 20000 Btu/jam ft2
= 203.40 ft2
Spesifikasi jenis tube yang digunakan: (Tabel 10, kern)
OD = 3/4 in
ID = 0.62 in
BWG = 16
Surface per lin ft, ft2 (As') = 0.1963 ft2/ft
Panjang (L) = 16 ft

Luas perpindahan panas 1 tube (As'') = As' x L


= 0.1963 (ft2/ft) x 16 ft
= 3.1408 ft 2

Luas perpindahan panas total (ft2)


Jumlah tube (Nt) =
Luas perpindahan panas 1 tube (ft2)
203.40 ft2
= = 64.8 tube = 65 tube
3.1408 ft2

KESIMPULAN FURNACE

Nama alat = Furnace


Tugas = Memanaskan dowtherm A dari suhu 150.35 °C menjadi 300.00 °C
Beban panas = 4067976.15 Btu/jam
Luas perpindahan panas = 203.40 ft2
Ukuran tube :
OD = 3/4 in
ID = 0.62 in

8
Lampiran Utilitas-Unit Penyedia Dowtherm AG

BWG = 16
Panjang tube = 16 ft
Jumlah tube = 65
Jumlah alat = 1
Kebutuhan bahan bakar = 99.305 kg/jam
BLOWER

Tugas : Mengalirkan udara kedalam furnace


jenis : Blower Sentrifugal

Menentukan kebutuhan udara


Udara yang diperlukan 25% berlebih atau setara dengan 17.4 kg udara/kg bahan bakar
Kebutuhan udara = Kebutuhan bahan bakar (kg/jam) x 17.4 kg udara/kg bahan bakar
= 99.305 kg bahan bakar/jam x 17.4 kg udara/kg bahan bakar
= 1727.906 kg udara
= 3809.380 lb/jam
Suhu udara masuk = 30 °C = 86 °F

Kebutuhan udara (lb/jam) 3809.380 lb/jam


Kecepatan mol udara = = = 132.27 lbmol/jam
BM (lb/lbmol) 28.80 lb/lbmol
Kecepatan volumetrik udara (Q)
n x R x T Dimana :
Q =
P P = 14.7 psi
R = 10.73 ft3 psi/lbmol R
T = 86 °F = 546 R
132.27 (lbmol/jam) x 10.73 (ft3 psi/lbmol R) x 546 (R)
Q =
14.70 psi
= 52683.5 ft3 /jam
= 878.1 ft3 /menit

Diambil faktor keamanan = 20% maka:


Q = 878.1 ft3 /menit x 120%
= 1053.7 ft /menit
3

= 7882.0 gpm
Blower bekerja secara adiabatis , maka menurut Mc Cabe Smith ed 4 hal 189 diperoleh :
𝑃=(0,0643.𝑇𝑎.𝛾. 𝑞𝑜)/(520.(𝛾−1)"ƞ " )
[(𝑃𝑏/𝑃𝑎)^(1−1/𝛾)−1] Dimana :

9
Lampiran Utilitas-Unit Penyedia Dowtherm AG
𝑃=(0,0643.𝑇𝑎.𝛾. 𝑞𝑜)/(520.(𝛾−1)"ƞ " )
[(𝑃𝑏/𝑃𝑎)^(1−1/𝛾)−1]
P : Power blower (Hp)
A B Ta : Suhu operasi (R)
qo : Kecepatan volumetrik udara ft3 /menit
ƞ : Effisiensi blower %
Pa : Tekanan masuk blower psi
Pb : Tekanan keluar blower psi
ɤ : Konstanta ratio kapasitas panas (Cp/Cv)
Nilai variabel :
Ta = 546 R
qo = 1053.7 ft3 /menit
ƞ = 85%
Pa = 14.7 psi
Jika diasumsikan pressure drop pada furnace = 2 psi,, maka Pb = Pa + Pressure drop
Pb = 16.7 psi
Cp udara = 0.0292 (Engineering toolbox)
Cv udara = 0.0208 (Engineering toolbox)
ɤ = Cp/Cv
= 1.4056
Sehingga :
A = 289.876
B = 1.037
P = 10.9 Hp Dipakai power standar sebesar 10.0 Hp (NEMA)

KESIMPULAN BLOWER

Tugas : Mengalirkan udara kedalam furnace


Jenis : Blower Sentrifugal
Kapasitas = 7882.0 gpm
Motor Standar = 10.0 Hp

10
Lampiran Utilitas-Unit Penyedia Dowtherm AG

TANGKI BAHAN BAKAR

Tugas : Menyimpan bahan bakar untuk persediaan 15 hari sebagai bahan bakar furnace
Jenis alat : tangki silinder vertikal

Perhitungan dimesi alat


Kapasitas untuk waktu tinggal = Jumlah hari x 24 jam/hari
= 15 hari x 24 jam/hari
= 360 jam
Massa bahan bakar yang disimpan (M) = Kebutuhan bahan bakar (kg/jam) x waktu tinggal (jam)
= 99.305 kg/jam x 360 jam
= 35749.78 kg
= 78814.77 lb
Volume bahan bakar (Vl) = M (lb) / Densitas bahan bakar (lb/gal)
= 78814.77 lb / 8.180 lb/gal
= 9634.68 gal = 36.47 m3
Over design = 20%
Volume tangki (Vt) = 120% x Vl = 43.77 m3
Dirancang rasio = 1 : 1 (H : D)
π x D2
H = Vt
4
π x D2
D = Vt
4
4 x Vt
D3 =
π
D = 3.820 m
L = 1 x 3.820 m = 3.820 m
Sehingga :
Tinggi tangki = 3.820 m
Diameter tangki = 3.820 m

11
Lampiran Utilitas-Unit Penyedia Dowtherm Ag

COOLER UTILITAS-01
Fungsi : Mendinginkan dowtherm yang keluar dari Melter dan Heater-01 dengan fluida pendingin
berupa air
Jenis : Shell and tube exchanger

Kondisi dowtherm A umpan cooler :


Laju massa = 6000 kg/jam = 13227.7 lb/jam
Tekanan = atm
Suhu = 120.71 °C atau 249.29 °F
Dowtherm tersebut akan didinginkan menjadi 60.00 °C atau 140.00 °F
Sehigga :
T1 = 120.71 °C = 249.29 °F
T2 = 60.00 °C = 140.00 °F
T average = 90.36 °C = 194.64 °F Pada suhu rata-rata diperoleh :
Kapasitas panas (Cp) = 0.42 Btu/lb°F
Viskositas (µ) = 1.09 cP
Densitas (ρ) = 62.33 lb/ft3
Konduktifitas thermal(k) = 0.074 Btu/hr ft °F

Menentukan beban panas (Q)


Q = Laju Massa (lb/jam) x Cp (Btu/lb°F) x (T1-T2) °F
= 13227.7 lb/jam x 0.42 Btu/lb°F x ( 249.3 - 140.0 ) °F
= 613501.38 Btu/jam
Sehingga :
Beban cooler = 613501.38 Btu/hr

Menentukan jumlah pendingin


Jenis pendingin : Air
Range suhu operasi : 30-50 °C
Kondisi pendingin :
Suhu masuk (t1) = 30.00 °C = 86.00 °F
Suhu keluar (t2) = 50.00 °C = 122.00 °F
Suhu masuk rata-rata = 40.00 °C = 104.00 °F
Pada suhu rata-rata diperoleh :
Kapasitas panas (Cp) = 1.000 Btu/lb °F
Viskositas (µ) = 0.67 cP
Densitas (ρ) = 63.29 lb/ft3
Konduktifitas thermal(k) = 0.362 Btu/hr ft °F
Specific gravity = 1.000
Q (Btu/hr) 613501.38
Massa pendingin = Cp (Btu/lb hr) x (t -t )°F = = 17047.13 lb/jam
2 1 1.0 x 36.0
= 7732.45 kg/jam

12
Lampiran Utilitas-Unit Penyedia Dowtherm Ag

Menentukan ΔT LMTD
T1 = 249.29 °F
T2 = 140.00 °F
t1 = 86.00 °F
t2 = 122.00 °F

Sehingga diperoleh ΔT LMTD = 85.47 °F

Menentukan koeffisien perpindahan panas (U)


Hot Fluid = Dowtherm (Diasumsikan Seperti Heavy Organic)
Cold Fluid = Air
Range U = 5 s.d. 75 Btu/hr ft2 oF
Dipilih = 20.000 Btu/hr ft2 oF
PERKIRAAN DIMENSI
Menentukan Heat Transfer Area (A)
𝐴=𝑄/(𝑈 𝑥 ∆𝑇 𝐿𝑀𝑇𝐷) Dimana :
Q = 613501.38 Btu/hr
U = 20.00 Btu/hr ft2 oF
ΔT LMTD = 122.00 °F
Sehingga diperoleh
A= 251.43 ft2 Karena A > 100 ft2 maka digunakan shell and tube exchanger
(Kern hal 103)
Menentukan jumlah pass pada shell side
S=((t_2−t_1
R=((T_1−T_2 ))/((t_2−t_1 Diperoleh
) ) ))/((T_1−t_1 )) : Berdasarkan fig.18-23 hal 828-833 kern
R = 3.04 Dipilih jumlah pass pada shell side= 2
S = 0.22 Dengan jumlah pass tube side 4 atau lebih
Ft = 0.96
Sehingga diperoleh ΔT LMTD sesungguhnya= ΔT LMTD x Ft = 82.05 °F

Menentukan ukuran Tube


Dipilih :OD = 1 1/4 in = 0.1042 ft
BWG = 16.00
Panjang standar (L) = 16.00 ft
Dari tabel 10 Kern didapat, harga
ID tube = 1.12 in = 0.0933 ft
Flow area per tube (at') = 0.985 in
Surface per lin ft (at'') = 0.3271 ft2/ft

Menentukan jumlah tube (Nt)


𝑁𝑡=𝐴/(𝑎𝑡′′ 𝑥 𝐿) Dimana : A = 251.43 ft2
at'' = 0.3271 ft2/ft
L = 16.00 ft
Sehingga diperoleh
Nt = 48.04

13
Lampiran Utilitas-Unit Penyedia Dowtherm Ag

Dari tabel 9 kern, diperoleh cooler dengan spesifikasi :


OD = 1.25 in
Jenis pitch = Triangular
Nilai pitch = 1.56 in
Jumlah tube pass = 4.00
Jumlah tube (Nt) = 62.00
ID shell (IDs) = 17 1/4 in = 1.44 ft
Menentukan Heat Transfer Area Terkoreksi (A terkoreksi)
𝐴 𝑡𝑒𝑟𝑘𝑜𝑟𝑒𝑘𝑠𝑖=𝑁𝑡 𝑥 𝑎𝑡^′′ 𝑥 𝐿
Dimana : Nt = 62.00 Sehingga diperoleh : A terkoreksi = 324.48 ft2
at'' = 0.3271 ft2/ft
L = 16.00 ft
Menentukan koeffisien perpindahan panas terkoreksi (U terkoreksi)
𝑈 𝑡𝑒𝑟𝑘𝑜𝑟𝑒𝑘𝑠𝑖=𝑄/(𝐴 𝑡𝑒𝑟𝑘𝑜𝑟𝑒𝑘𝑠𝑖 𝑥 ∆𝑇 𝐿𝑀𝑇𝐷) Dimana : Q = 613501.38 Btu/hr
A terkoreksi = 324.48 ft2
ΔT LMTD = 82.05 °F
Sehingga diperoleh U terkoreksi = 23.04 Btu/hr ft F
2 o

Menentukan koeffisien hi dan hio pada Tube side


Fluida :Dowtherm A :
Kapasitas panas (Cp) = 0.424 Btu/lb °F
Viskositas (µ) = 1.088 cP
Densitas (ρ) = 62.325 lb/ft3
Konduktifitas thermal(k) = 0.074 Btu/hr ft °F
Specific gravity = 1.034
Mass rate = 13227.75 lb/jam

1. Luas Pipa (at)


𝑎𝑡=(𝑁𝑡 𝑥 𝑎𝑡′)/(144 𝑥 𝑛)Dimana : Nt = Jumlah tube = 62.00
at' = Flow area per tube = 0.985 in
n = Jumlah pass tube side = 4.00
Sehingga diperoleh at = 0.1060 ft2
2. Kecepatan Massa Umpan (Gt)
𝐺𝑡=(𝑀 )/𝑎𝑡 Dimana : M = Mass rate = 13227.75 lb/hr
at = Luas pipa = 0.106 ft 2

Sehingga diperoleh Gt = 124761.4540 lb/ ft2 hr = 34.6560 lb/ ft2 s


3. Kecepatan linier umpan (Vt)
𝑉𝑡=(𝐺𝑡 )/𝜌 Dimana : Gt = Kecepatan massa umpan = 34.656 lb/ ft2 s
ρ = Densitas = 62.325 lb/ft3
Vt = 0.556 ft/ s
4. Bilangan Reynold (Re)

𝑅𝑒=(𝐼𝐷 𝑡𝑢𝑏𝑒 𝑥 𝐺𝑡 )/µ Dimana : Gt = 124761.45 lb/ ft2 hr


ID tube = 0.09 ft
µ = 1.09 cP = 2.63 lb/ft hr

14
Lampiran Utilitas-Unit Penyedia Dowtherm Ag

Re = 4426.04
L/D = 171.43
Pada fig.24 diperoleh nilai jH = 17.00
Dimana :
ℎ𝑖=𝑗𝐻 (𝑘 )/𝐷 ((𝐶𝑝 𝜇)/𝑘)^(1/3) (( 𝜇)/𝜇𝑤)^0,14
jH = 17.00 µ = 2.63 lb/ft hr
k = 0.07 Btu/hr ft °F
D = 0.09 ft
Cp = 0.42 Btu/lb °F
µ/µw= Diabaikan (dianggap 1)
hi = 33.18 Btu/hr ft2 °F
ℎ𝑖𝑜=ℎ𝑖 (𝐼𝐷 𝑡𝑢𝑏𝑒 )/(𝑂𝐷 𝑡𝑢𝑏𝑒) Dimana :
hi = 33.18 Btu/hr ft2 °F
ID tube = 0.0933 ft
OD tube = 0.1042 ft
hio = 29.73 Btu/hr ft °F 2

Menentukan koeffisien ho pada shell side


Fluida : Air pendingin
1. Clearence (C')
"C" ^′=pt−OD tube Dimana : pt = Pitch = 1.56 in
OD tube = 1.25 in
Sehingga :
C' = 0.3125 in
2. Jarak Baffle (B)
IDs = 17.25 in
Range = 1/5 IDs sampai IDs
Dipilih B = 1/5 IDs = 3.45 in
3. Luas Penampang shell (as)
𝑎𝑠=(𝐼𝐷𝑠 (𝑖𝑛) 𝑥 𝐶^′ (𝑖𝑛) 𝑥 𝐵 (𝑖𝑛))/(144 (𝑖𝑛^2/𝑓𝑡^2
Dimana : IDs) =
𝑥 𝑝𝑡17.25
(𝑖𝑛)) in
C' = 0.31 in
B = 3.45 in
pt = 1.56 in
Sehingga :
as = 0.083 ft2
4. Kecepatan umpan pada shell side (Gs')
𝐺𝑠′=(𝐿𝑎𝑗𝑢 𝑚𝑎𝑠𝑠𝑎 (𝑙𝑏/ℎ𝑟) )/(𝑎𝑠 (𝑓𝑡^2Dimana
)) : Laju massa = 7732.448 kg/hr
= 17047.132 lb/hr
as = 0.08 ft2
Sehingga :
Gs' = 206241.29 lb/hr ft2

5. Kecepatan umpan pada shell side (Gs'')


Diameter ekivalen (De) = 0.91 in
= 0.0758 ft
𝐺𝑠′′=(𝐿𝑎𝑗𝑢 𝑚𝑎𝑠𝑠𝑎 (𝑙𝑏/ℎ𝑟) )/(𝐿 (𝑓𝑡)𝑥 〖𝑁𝑡〗
Persamaan 12.43 Kern
^(2/3) )

15
Lampiran Utilitas-Unit Penyedia Dowtherm Ag
𝐺𝑠′′=(𝐿𝑎𝑗𝑢 𝑚𝑎𝑠𝑠𝑎 (𝑙𝑏/ℎ𝑟) )/(𝐿 (𝑓𝑡)𝑥 〖𝑁𝑡〗 ^(2/3) )
Dimana : Laju massa = 17047.132 lb/hr
L = 16.00 ft
Nt = 62.00
Sehingga Gs'' = 68.01 lb/hr lin ft
6. Menentukan suhu dinding (t wall)
Trial nilai ho= 527.39 Btu/hr ft2 °F
t wall=ta+(ho )/(ho+hio) (Tv−ta)Dimana : ta = Suhu rata-rata pengembun
Tv = Suhu rata-rata uap
ta = 104.00 °F Sehingga :
Tv = 194.64 °F t wall = 189.81 °F = 87.67 °C = 360.67 K

Tv = 194.64 °F = 90.36 °C = 363.36 K


ta = 104.00 °F = 40.00 °C = 313.00 K
7. Properties fluida pada ta dan t wall
Specific gravity (s) = 1.0000
Viskositas (µ) = 0.6730 cP
= 1.6282 lb/ft hr
Konduktifitas thermal (k) = 0.3616 Btu/hr ft °F
Kaspitas panas (Cp) = 0.9997 Btu/lb °F
Viskositas t wall (µw) = 0.3230 cP
= 0.7815 lb/ft hr
8. Koeffisien transfer panas ho
Re=(De x Gs )/𝜇 Dimana : De = 0.0758 ft
Gs = 206241.29 lb/hr ft2
µ = 1.6282 lb/ft hr
Sehingga :
Re = 9605.66 Pada fig.28 page 838 Kern diperoleh nilai jH
jH = 60.00 Btu/hr ft2 °F
ho=jH (k )/De ((𝐶𝑝 𝜇)/𝑘)^(1/3) (( 𝜇)/𝜇𝑤)^0,14
Dimana : k = 0.3616 Btu/hr ft °F
De = 0.0758 ft
Cp = 0.9997 Btu/lb °F
µ = 1.6282 lb/ft hr
µw = 0.7815 lb/ft hr
Sehingga :
ho = 523.47 (Trial tepat)

Menentukan koeffisien hi dan hio terkoreksi pada Tube side


µw = 1.13 cP Pada t wall
µ = 1.09 cP
(𝜇/𝜇𝑤)^0,14 〖ℎ𝑖 𝑡𝑒𝑟𝑘𝑜𝑟𝑒𝑘𝑠𝑖 =ℎ𝑜(𝜇/𝜇𝑤) 〗 ^0,14 hi = 33.18 Btu/hr ft2 °F
= 0.994
hio =
〖ℎ𝑖𝑜 𝑡𝑒𝑟𝑘𝑜𝑟𝑒𝑘𝑠𝑖 =ℎ𝑖𝑜(𝜇/𝜇𝑤) 〗 ^0,14 29.73 Btu/hr ft2 °F

16
Lampiran Utilitas-Unit Penyedia Dowtherm Ag

Menentukan koeffisien Transfer panas keseluruhan (Uc)


𝑈𝑐=(ℎ𝑖𝑜 𝑥 ℎ𝑜)/(ℎ𝑖𝑜+ℎ𝑜)
Dimana : ho = 523.47 Btu/hr ft2 °F
hio = 29.73 Btu/hr ft2 °F
Sehingga : Uc = 28.129 Btu/hr ft2 °F

Menentukan Dirt Factor (Rd)


𝑅𝑑=(𝑈𝑐 −𝑈𝑑)/(𝑈𝑐 𝑥 𝑈𝑑)Dimana : Uc = 28.129 Btu/hr ft2 °F
Ud = 23.043 Btu/hr ft2 °F
Sehingga :Rd = 0.00785
Rd min :
Heavy organic = 0.00100 (Kern page 845)
Air = 0.00200 (Kern, 845)
Jumlah Rd min = 0.00300
Syarat Kelayakan HE :
Rd > Rd min Terpenuhi
Uc > Ud Terpenuhi

MENENTUKAN PRESSURE DROP

Pressure drop tube side


1. Menentukan faktor friksi (f)
Re = 4426.04
Pada fig.26 page 836, diperoleh f = 0.00034
2. Pressure drop tube (ΔPt)
∆𝑃𝑡=(𝑓 𝑥 〖𝐺𝑡〗 ^2 𝑥 𝐿 𝑥 𝑛)/(5,22 𝑥 〖 10 Dimana : 𝑥Gt𝑠 𝑥 𝜑𝑡)
〗 ^10 𝑥 𝐷 : Laju alir massa (lb/hr ft2)
L : Length of tube path (ft)
n : Number of tube Passes
D : ID tube (ft)
s : Specific gravity
ϕt : (µ/µw)0,14 Above Re >2100
: (µ/µw) 0,25
Below Re >2100
Nilai variabel :
Gt = 124761.4540
L = 16.00
n = 4.00
D = 0.0933

s = 1.03
ϕt = 0.99
Sehingga :
ΔPt = 0.0676 psi
3. Return pressure loss (ΔPr)
Dimana : n : Number of tube passes
∆𝑃𝑟=(4 𝑛)/( 𝑠) 𝑉^2/( 2 𝑔′) (62,5/( 144))
s : Specific gravity
V : Velocity (ft/s)

17
Lampiran Utilitas-Unit Penyedia Dowtherm Ag

g' : Acceleration of gravity (ft/s2)


Nilai variabel :
n = 4.00
s = 1.03
V = 0.556
g' = 32.20
Sehingga :
ΔPr = 0.0322 psi
4. Total Pressure drop tube side (ΔPTt)
∆𝑃𝑇𝑡=∆𝑃𝑡+∆𝑃𝑟
ΔPt = 0.07 psi
ΔPr = 0.0322 psi
ΔPTt = 0.0998 psi < 10 psi, HE memenuhu standar

Pressure drop shell side


Specific gravity= 1.00000

1. Bilangan Reynold (Re)

Re = 9605.656 Pada fig.29 page 839 kern diperoleh f = 0.00190


2. Number of cross (N +1)
𝑁+1=(12 𝑥 𝐿 (𝑖𝑛) )/(𝐵 (𝑖𝑛))
Dimana : L = 16.00 ft
B = 3.45 in
Sehingga :
N + 1 = 55.65
3. Pressure drop shell side (ΔPs)
Dimana
∆𝑃𝑠=1/( 2) (𝑓 𝑥 〖𝐺𝑠〗 ^2 𝑥 𝐼𝐷𝑠 𝑥 (𝑁+1))/( 5,22:𝑥 f〖 10 〗 ^10
= 𝑥 0.00190
𝐷𝑒 𝑥 𝑠)
Gs = 206241.29 lb/hr ft2
IDs = 1.43750 ft
N + 1 = 55.65217
De = 0.07583
s = 1.00000
Sehingga :
ΔPs = 0.81665 psi < 10 psi, HE memenuhu standar

18
Lampiran Utilitas-Unit Penyedia Dowtherm Ag

KESIMPULAN

Fungsi : Mendinginkan dowtherm A yang keluar dari Melter dan Heater-01 dengan
fluida pendingin berupa air
Beban panas : 613501.4 Btu/jam
Tipe : Shell and tube exchanger
Tube
Diameter dalam = 0.0933 ft = 0.0284 m
Diameter luar = 0.10 ft = 0.0318 m
BWG = 16.00
Susunan = Triangular
Jumlah = 62.00
Panjang = 16.00 ft = 4.8768 m
Pass = 4.00
Bahan = Stainless steel
Pressure drop = 0.10 psi
Shell
Diameter dalam = 1.44 ft = 0.4382 m
Pass = 2.00
bahan = Stainless steel
Pressure drop = 0.82 psi
Luas transfer = 324.48 ft2 = 30.145 m2
Uc = 28.129 Btu/hr ft2 °F
Ud = 23.043 Btu/hr ft2 °F
Rd min = 0.0030
Rd = 0.0078
Harga = $ 2,617.17

19
Lampiran Utilitas-Unit Penyedia Dowtherm AG

POMPA UTILITAS-06

Tugas : Memompa Dowtherm A menuju Furnace dan reboiler

Sketsa :

0,5 m
0,5 m
1,97 m

1,94 m
HE-1
R-01 0,5 m FURNACE 0,5 m

51, 1 m 0,5 m 0,5 m RB-01


43 m
2m

Informasi penunjang :
Bidang datum = Permukaan tanah (Z = 0 m)
Pada Titik 1 (Titik keluaran Dowtherm A dari Reaktor-01)
P1 = 1 atm = 101325 Pa = 101325 kg/m.s2
Z1 = 1.97 m
V1 = V2

Pada Titik 2 (Ujug pipa pemasukan Reboiler-01) :


P2 = 1 atm = 101325 Pa = 101325 kg/m.s2
Z2 = 1.94 m
V3 = V2

Data fluida masuk pompa :


Suhu = 150.35 °C
Tekanan = 1 atm = 101325 Pa
Tekanan uap = 3.700 bar
= 370000 Pa = 370000 kg/m.s2
1. Menentukan kapasitas pompa
W = 17700 kg/jam = 39022 lb/jam
ρ = 981.194 kg/m3 = 61.254 lb/ft3
Laju massa 17700 kg/jam
QL = = = 18.0393 m3/jam = 0.00501 m3/s
Densitas 981.194 kg/m 3

= 0.17696 ft3/s

20
Lampiran Utilitas-Unit Penyedia Dowtherm AG

= 0.30065 m3/menit
= 79.4245 gpm
2. Menentukan ukuran pipa
Untuk menghitung diameter optimum pipa, digunakan persamaan (Peters, M., dan K.D. Timmerhaus,
edisi 4, halaman 497)
Dopt = 3,9 qf0,45 ρ0,13
Dimana,
Dopt = diameter dalam pipa, in
qf = laju alir fluida, ft3/s
ρ = densitas fluida, lb/ft3
Maka,
0.45 0.13
Dopt = 3.9 x 0.177 x 61.254
= 3.054 in
Diambil ukuran pipa dengan spesifikasi sebagai berikut (Tabel. 11, Kern, 1965, hal 844) :
IPS = 4 in
OD = 4.5 in
Sch.no = 40
ID = 4.026 in = 0.10226 m
At = 12.7 in 2
= 0.00819 m2

3. Menentukan Head Pompa


a. Bahan Konstruksi
Dipilih bahan konstruksi berupa Commercial steel.
Berdasarkan Tabel. 6.1, hal. 349, Fluid Mechanics 4th, Frank M. White, 1997.
Maka,diperoleh kekerasan pipa 𝝴 = 4.6E-05 m
b. Kekerasan relatif
Berdasarkan data diatas, diperoleh kekerasan realtif :
𝝴 4.6E-05 m
= = 4.5E-04
ID 0.10226 m
c. Kecepatan linear (Vlin)
Untuk menghitung kecepatan linier, digunakan rumus sebagai berikut:
QL 0.00501 m3/s
Vlin = = = 0.61157 m/s
At 0.00819 m2
d. Viskositas (µ)
µ Dowtherm A = 0.18 m.Pa.s
= 0.00018 kg/m.s

21
Lampiran Utilitas-Unit Penyedia Dowtherm AG

e. Bilangan Reynold (Re)


ρ ID Vlin 981.194 kg/m3 x 0.10226 m x 0.61157 m/s
Re = = = 340906
µ 0.00018 kg/m.s

f. Head karena friksi


Faktor friksi darcy :
Diperoleh dari Fig. 6.13, hal. 349, Fluid Mechanics 4th, White ,F.M., 1997
Diperoleh nilai friction factor (f) = 0.0172
Panjang pipa :
Panjang pipa lurus (L) = 99.04 m
Panjang pipa ekivalen =
Dari Ludwig, E.E, ed III, Vol 1, 2001, hal. 87 :
Perihal Le (ft) Jumlah Σ Le (ft) Σ Le (m)
Valve (Globe) 85 1 85 25.908
Check Valve 19 1 19 5.791
Sudden enlargement 5.5 1 5.5 1.676
Elbow 5.2 9 46.8 14.265
Sudden contraction 2.8 1 2.8 0.853
Jumlah 159.1 48.494
Sehingga diperoleh :
Panjang ekivalen (Le)= 48.494 m
Head karena friksi (hf) :
2
f (L + Le) Vlin2 0.0172 x ( 99.04 + 48.494 ) m x 0.6116 m2/s2
hf = =
2 g ID 2 x 9.8 m/s2 x 0.10226 m

= 0.47353 m

g. Rapat berat (ɤ)


ɤ = ρ x g
= 981.194 kg/m3 x 9.8 m/s2 = 9615.7 kg/m2.S2 9615.7 N/m3

h. Head Pompa
Dihitung menggunakan persamaan berno:

Dengan :

22
Lampiran Utilitas-Unit Penyedia Dowtherm AG

g = Percepatan gravitasi normal (m/s2) V2 = Kecepatan linear pada titik 2 (m/s)


hf = Head karena friksi (m)
Z1 = Elevasi titik 1 (m)
Z2 = Elevasi titik 2 (m)
Hman = Head pompa (m)
P1 = Tekanan pada titik 1 (Pa atau kg/m.s2)
P2 = Tekanan pada titik 2 (Pa atau kg/m.s2)
V1 = Kecepatan linear pada titik 1 (m/s)
Head beda tekanan
( 101325 - 101325 ) kg/m.s2
= = 0 m
9615.7 kg/m2.S2

Head potensial
Z2 - Z1 = 1.94 - 1.97 = -0.03 m

Head kinetik
2 2
( 0.6116 - 0.6116 ) m2/s2
= = 0 m
2 x 9.8 m/s2

Maka Head pompa :

hman =

= 0 m + -0.03 m + 0 m + 0.47353 m = 0.44353 m

4. Kecepatan spesifik (Ns)


Kecepatan spesifik dihitung dari pers. 1.7 , Sularso dan Tahara Haruo, “Pompa dan Kompresor",
PT. Pradnya Parmita, Jakarta, 2000, hal. 5 :
N Ql Dengan :
Ns  hman = Head pompa (m)
hman0.75
N = Kecepatan putar (rad/s)
Ns = Kecepatan spesifik
QL = Kapasitas pompa (m3/s)

Kecepatan putar (N)


Dipilih berdasarkan tabel 14.2 Ludwig, E.E, 3th, Vol 3, halaman 624.
Kecepatan putar = 3000 rpm

23
Lampiran Utilitas-Unit Penyedia Dowtherm AG

faktor slip = 0.05 Asumsi


N = rpm x (1-faktor slip)
= 3000 rpm x (1 - 0.05 ) =
2850 rpm
N = 2850 rotasi/menit x (1 menit/60 s) x (2π x rad/rotasi)
= 298.3 rad/s
Maka kecepatan spesifik
0.5
Ns 298.3 rad/s x ( 0.00501 m3/s )
= 0.75 = 38.8526
( 0.44353 m )

5. Daya gerak pompa (W)


Dihitung dengan persamaan sebagai berikut :

Dimana:
efp = Effisiensi pompa
hman = Head pompa (m)
QL = Kapasitas pompa (m3/s)
W = Daya penggerak poros (watt)
γ = Rapat berat (N/m3)
Effisiensi pompa
Dari Fig. 10. 63, Towler and Sinnot, “Principles, Practice and Economics of Plant and Process
Design”, Elsevier San Diego, 2008, hal. 625 didapatkan
Effisiensi pompa = 0.65

24
Lampiran Utilitas-Unit Penyedia Dowtherm AG

Maka daya penggerak pompa (W)


0.00501 m3/s x 9615.7 N/m3 x 0.44353 m
- W =
0.65
= 1643.9 watt = 2.204 Hp
(tanda minus (-) menandakan aliran membutuhkan kerja dari luar)

6. Motor standar
Dari Fig 14.38 Peters, M.S., K.D., timmerhaus ed.IV (1991), halaman 521,
Diperoleh efisiensi motor = 0.8
Maka daya motor yang diperlukan = 2.204 Hp / 0.8
= 2.756 Hp
Dipilih daya motor standar NEMA = 3 Hp (Ludwig, E.E., Vol III, halaman 628)

7. Net Positive Suction Head (NPSH)


a. NPSH yang tersedia (NPSHa)
NPSHa dapat dihitung dengan persamaan 3-10 p.190 Ludwig vol. 1

NPSHa =

Dimana :
NPSHa : NPSH yang tersedia
Pa : tekanan operasi
Pvp : tekanan uap murni
S : suction head (Z1)
hsl : kerugian head di dalam pipa isap/friction loss (m)
Menentukan Head Friski pada Daerah Hisap (hsl) :
- Panjang Pipa Lurus (L)
Panjang pipa lurus pada daerah hisap adalah 3 m
- Panjang Ekivalen (Le)
Dari Ludwig, E.E, ed III, Vol 1, 2001, hal. 87 :
Perihal Le (ft) Jumlah Σ Le (ft) Σ Le (m)
Valve (Globe) 85 0 0 0.000
Check Valve 19 0 0 0.000
Sudden enlargement 5.5 0 0 0.000
Elbow 5.2 1 5.2 1.585
Sudden contraction 2.8 1 2.8 0.853

25
Lampiran Utilitas-Unit Penyedia Dowtherm AG

Jumlah 8 2.438
Diperoleh Le = 2.438 m

2
f (L + Le) Vlin2 0.0172 x ( 3 + 2.438 ) m x 0.6116 m2/s2
hsl = =
2 g ID 2 x 9.8 m/s2 x 0.10226 m

= 0.01746 m

Tekanan uap murni dowtherm = 3.70 bar = 370000 kg/m.s2 sehingga


( 101325 - 370000 ) kg/m.s2
NPSHa = + 1 m - 0.01746 m
9615.7 kg/m2.S2
= 28.9238 m
b. NPSH yang diperlukan (HsvN)
HsvN dihitung dengan persaaan 2.34 Sularso, hal.46
Keterangan :
HSsvN =
N : Kecepatan putaran (rpm)
Q : Kapasitas pompa (m3/menit)

4/5 2/3
3000 rpm
HSsvN = 0.30065 m /menit
3
1200

= 0.93411 m
Dari hasil perhitungan diperoleh NPSH yang tersedia 28.9238 m > 0.93411 m (NPSH yang di-
perluka), maka pompa dapat bekerja tanpa mengalami kavitasi

26
Lampiran Utilitas-Unit Penyedia Dowtherm AG

KESIMPULAN

Tugas : Memompa Dowtherm A menuju Furnace dan reboiler

Tipe alat : Pompa sentrifugal

Data fluida :
Suhu masuk = 150.35 °C
P1 = 1.00 atm
P2 = 1.00 atm
Pemilihan pipa :
IPS = 4 in
OD = 4.5 in
Sch.no = 40
ID = 4.026 in
At = 12.7 in2
Spesifikasi pompa :
Kapasitas pompa = 0.00501 m3/s
Head pompa = 0.44353 m
Kecepatan putar = 3000 rpm
Motor standar = 3 Hp
NPSH :

27
Lampiran Utilitas-Unit Penyedia Dowtherm AG

NPSH tersedia = 28.9238 m


NPSH yang diperlukan = 0.93411 m

28
Lampiran Utilitas-Unit Penyedia Dowtherm A Lampiran Utilitas-Unit Penyedia Dowtherm AgG

POMPA UTILITAS-07

Tugas : Memompa Dowtherm A menuju Cooler-02, Heater 03, dan heater 01

Sketsa :

0 ,5 m 0,5 m
0,5 m , 0,5 m
, 1,94 m
2,88 m
2,5 m

H - 03 H - 02 1,
Tinggi penyangga = 1 m CL -02
1m 1m
3m 41, 4 m 22 ,5 m 58 ,9 m

Informasi penunjang :
Bidang datum = Permukaan tanah (Z = 0 m)
Pada Titik 1 (Ujug pipa keluaran Cooler Utilitas-01 untuk tube side)
P1 = 1 atm = 101325 Pa = 101325 kg/m.s2
Z1 = 1 m
V1 = V2

Pada Titik 2 (Ujug pipa pemasukan Cooler Utilitas-01 untuk tube side)
P2 = 1 atm = 101325 Pa = 101325 kg/m.s2
Z2 = 1.44 m
V3 = V2

Data fluida masuk pompa :


Suhu = 140.00 °C
Tekanan = 1 atm = 101325 Pa
Tekanan uap = 3.700 bar
= 370000 Pa = 370000 kg/m.s2
1. Menentukan kapasitas pompa
W = 6000 kg/jam = 13228 lb/jam
ρ = 1027.8 kg/m3 = 64.163 lb/ft3
Laju massa 6000 kg/jam
QL = = = 5.83772 m3/jam = 0.00162 m3/s
Densitas 1027.8 kg/m3

= 0.05727 ft3/s

29
Lampiran Utilitas-Unit Penyedia Dowtherm A Lampiran Utilitas-Unit Penyedia Dowtherm AgG

= 0.0973 m3/menit
= 25.7027 gpm
2. Menentukan ukuran pipa
Untuk menghitung diameter optimum pipa, digunakan persamaan (Peters, M., dan K.D. Timmerhaus,
edisi 4, halaman 497)
Dopt = 3,9 qf0,45 ρ0,13
Dimana,
Dopt = diameter dalam pipa, in
qf = laju alir fluida, ft3/s
ρ = densitas fluida, lb/ft3
Maka,
0.45 0.13
Dopt = 3.9 x 0.057 x 64.163
= 1.85 in
Diambil ukuran pipa dengan spesifikasi sebagai berikut (Tabel. 11, Kern, 1965, hal 844) :
IPS = 2 in
OD = 2.38 in
Sch.no = 40
ID = 2.067 in = 0.0525 m
At = 3.35 in 2
= 0.00216 m2

3. Menentukan Head Pompa


a. Bahan Konstruksi
Dipilih bahan konstruksi berupa Commercial steel.
Berdasarkan Tabel. 6.1, hal. 349, Fluid Mechanics 4th, Frank M. White, 1997.
Maka,diperoleh kekerasan pipa 𝝴 = 4.6E-05 m
b. Kekerasan relatif
Berdasarkan data diatas, diperoleh kekerasan realtif :
𝝴 4.6E-05 m
= = 8.8E-04
ID 0.0525 m
c. Kecepatan linear (Vlin)
Untuk menghitung kecepatan linier, digunakan rumus sebagai berikut:
QL 0.00162 m3/s
Vlin = = = 0.75029 m/s
At 0.00216 m2
d. Viskositas (µ)
µ Dowtherm A = 1.72 m.Pa.s
= 0.00172 kg/m.s

30
Lampiran Utilitas-Unit Penyedia Dowtherm A Lampiran Utilitas-Unit Penyedia Dowtherm AgG

e. Bilangan Reynold (Re)


ρ ID Vlin 1027.8 kg/m3 x 0.0525 m x 0.75029 m/s
Re = = = 23538.7
µ 0.00172 kg/m.s

f. Head karena friksi


Faktor friksi darcy :
Diperoleh dari Fig. 6.13, hal. 349, Fluid Mechanics 4th, White ,F.M., 1997
Diperoleh nilai friction factor (f) = 0.0285
Panjang pipa :
Panjang pipa lurus (L) = 139.58 m
Panjang pipa ekivalen =
Dari Ludwig, E.E, ed III, Vol 1, 2001, hal. 87 :
Perihal Le (ft) Jumlah Σ Le (ft) Σ Le (m)
Valve (Globe) 55 1 55 16.764
Check Valve 14 1 14 4.267
Sudden enlargement 5 1 5 1.524
Elbow 3.5 12 42 12.802
Sudden contraction 1.8 1 1.8 0.549
Jumlah 117.8 35.905
Sehingga diperoleh :
Panjang ekivalen (Le)= 35.905 m
Head karena friksi (hf) :
2
f (L + Le) Vlin2 0.0285 x ( 139.58 + 35.905 ) m x 0.7503 m2/s2
hf = =
2 g ID 2 x 9.8 m/s2 x 0.0525 m

= 2.73598 m

g. Rapat berat (ɤ)


ɤ = ρ x g
= 1027.8 kg/m3 x 9.8 m/s2 = 10072.4 kg/m2.S2 10072.4 N/m3

h. Head Pompa
Dihitung menggunakan persamaan berno:

Dengan :

31
Lampiran Utilitas-Unit Penyedia Dowtherm A Lampiran Utilitas-Unit Penyedia Dowtherm AgG

g = Percepatan gravitasi normal (m/s2) V2 = Kecepatan linear pada titik 2 (m/s)


hf = Head karena friksi (m)
Z1 = Elevasi titik 1 (m)
Z2 = Elevasi titik 2 (m)
Hman = Head pompa (m)
P1 = Tekanan pada titik 1 (Pa atau kg/m.s2)
P2 = Tekanan pada titik 2 (Pa atau kg/m.s2)
V1 = Kecepatan linear pada titik 1 (m/s)
Head beda tekanan
( 101325 - 101325 ) kg/m.s2
= = 0 m
10072.4 kg/m2.S2

Head potensial
Z2 - Z1 = 1.44 - 1 = 0.44 m

Head kinetik
2 2
( 0.7503 - 0.7503 ) m2/s2
= = 0 m
2 x 9.8 m/s2

Maka Head pompa :

hman =

= 0 m + 0.44 m + 0 m + 2.73598 m = 3.17598 m

4. Kecepatan spesifik (Ns)


Kecepatan spesifik dihitung dari pers. 1.7 , Sularso dan Tahara Haruo, “Pompa dan Kompresor",
PT. Pradnya Parmita, Jakarta, 2000, hal. 5 :
N Ql Dengan :
Ns  hman = Head pompa (m)
hman0.75
N = Kecepatan putar (rad/s)
Ns = Kecepatan spesifik
QL = Kapasitas pompa (m3/s)

Kecepatan putar (N)


Dipilih berdasarkan tabel 14.2 Ludwig, E.E, 3th, Vol 3, halaman 624.
Kecepatan putar = 3000 rpm

32
Lampiran Utilitas-Unit Penyedia Dowtherm A Lampiran Utilitas-Unit Penyedia Dowtherm AgG

faktor slip = 0.05 Asumsi


N = rpm x (1-faktor slip)
= 3000 rpm x (1 - 0.05 ) =
2850 rpm
N = 2850 rotasi/menit x (1 menit/60 s) x (2π x rad/rotasi)
= 298.3 rad/s
Maka kecepatan spesifik
0.5
Ns 298.3 rad/s x ( 0.00162 m3/s )
= 0.75 = 5.04912
( 3.17598 m )

5. Daya gerak pompa (W)


Dihitung dengan persamaan sebagai berikut :

Dimana:
efp = Effisiensi pompa
hman = Head pompa (m)
QL = Kapasitas pompa (m3/s)
W = Daya penggerak poros (watt)
γ = Rapat berat (N/m3)
Effisiensi pompa
Dari Fig. 10. 63, Towler and Sinnot, “Principles, Practice and Economics of Plant and Process
Design”, Elsevier San Diego, 2008, hal. 625 didapatkan
Effisiensi pompa = 0.5

33
Lampiran Utilitas-Unit Penyedia Dowtherm A Lampiran Utilitas-Unit Penyedia Dowtherm AgG

Maka daya penggerak pompa (W)


0.00162 m3/s x 10072.4 N/m3 x 3.17598 m
- W =
0.5
= 1037.49 watt = 1.391 Hp
(tanda minus (-) menandakan aliran membutuhkan kerja dari luar)

6. Motor standar
Dari Fig 14.38 Peters, M.S., K.D., timmerhaus ed.IV (1991), halaman 521,
Diperoleh efisiensi motor = 0.8
Maka daya motor yang diperlukan = 1.391 Hp / 0.8
= 1.739 Hp
Dipilih daya motor standar NEMA = 2 Hp (Ludwig, E.E., Vol III, halaman 628)

7. Net Positive Suction Head (NPSH)


a. NPSH yang tersedia (NPSHa)
NPSHa dapat dihitung dengan persamaan 3-10 p.190 Ludwig vol. 1

NPSHa =

Dimana :
NPSHa : NPSH yang tersedia
Pa : tekanan operasi
Pvp : tekanan uap murni
S : suction head (Z1)
hsl : kerugian head di dalam pipa isap/friction loss (m)
Menentukan Head Friski pada Daerah Hisap (hsl) :
- Panjang Pipa Lurus (L)
Panjang pipa lurus pada daerah hisap adalah 3 m
- Panjang Ekivalen (Le)
Dari Ludwig, E.E, ed III, Vol 1, 2001, hal. 87 :
Perihal Le (ft) Jumlah Σ Le (ft) Σ Le (m)
Valve (Globe) 55 0 0 0.000
Check Valve 14 0 0 0.000
Sudden enlargement 5 0 0 0.000
Elbow 3.5 1 3.5 1.067
Sudden contraction 1.8 1 1.8 0.549

34
Lampiran Utilitas-Unit Penyedia Dowtherm A Lampiran Utilitas-Unit Penyedia Dowtherm AgG

Jumlah 5.3 1.615


Diperoleh Le = 1.615 m

2
f (L + Le) Vlin2 0.0285 x ( 3 + 1.615 ) m x 0.7503 m2/s2
hsl = =
2 g ID 2 x 9.8 m/s2 x 0.0525 m

= 0.07196 m

Tekanan uap murni dowtherm = 3.70 bar = ### kg/m.s2 sehingga


( 101325 - 370000 ) kg/m.s2
NPSHa = + 1 m - 0.07196 m
10072.4 kg/m2.S2
= 27.6023 m
b. NPSH yang diperlukan (HsvN)
HsvN dihitung dengan persaaan 2.34 Sularso, hal.46
Keterangan :
HSsvN =
N : Kecepatan putaran (rpm)
Q : Kapasitas pompa (m3/menit)

4/5 2/3
3000 rpm
HSsvN = 0.0973 m /menit3
1200

= 0.4403 m
Dari hasil perhitungan diperoleh NPSH yang tersedia 27.6023 m > 0.4403 m (NPSH yang di-
perluka), maka pompa dapat bekerja tanpa mengalami kavitasi

35
Lampiran Utilitas-Unit Penyedia Dowtherm A Lampiran Utilitas-Unit Penyedia Dowtherm AgG

KESIMPULAN

Tugas : Memompa Dowtherm A menuju Cooler-02, Heater 03, dan heater 01

Tipe alat : Pompa sentrifugal

Data fluida :
Suhu masuk = 140.00 °C
P1 = 1.00 atm
P2 = 1.00 atm
Pemilihan pipa :
IPS = 2 in
OD = 2.38 in
Sch.no = 40
ID = 2.067 in
At = 3.35 in2
Spesifikasi pompa :
Kapasitas pompa = 0.00162 m3/s
Head pompa = 3.17598 m
Kecepatan putar = 3000 rpm
Motor standar = 2 Hp
NPSH :

36
Lampiran Utilitas-Unit Penyedia Dowtherm A Lampiran Utilitas-Unit Penyedia Dowtherm AgG

NPSH tersedia = 27.6023 m


NPSH yang diperlukan = 0.4403 m
Harga = $ 1,630

37
FURN
DOWTHERM
Suhu = 225.175 Celsius
= 437.315 Farenheit
Kapasitas panas
T1 660.0000 F
T2 670.0000 F
Cp 1 0.5990 Btu/lb F
Cp 2 0.6040 Btu/lb F
T 437.3150 F
Cp T 0.4877 Btu/lb F

Viskositas T avg Viskositas T wall


T1 660.0000 F T1 680.0000 F
T2 670.0000 F T2 690.0000 F
miu 1 0.1600 cP miu 1 0.1500 cP
miu 2 0.1600 cP miu 2 0.1500 cP
T 437.3150 F T wall 667.7545 F
miu T 0.1600 cP miu T wall 0.1500 cP

Densitas
T1 660.0000 F
T2 670.0000 F
Rho 1 46.8200 Btu/lb F
Rho 2 46.3900 Btu/lb F
T 437.3150 F
Rho T 56.3955 Btu/lb F

Konduktifitas thermal
T1 660.0000 F
T2 670.0000 F
k1 0.0497 Btu/lb F
k2 0.0492 Btu/lb F
T 437.3150 F
k saat T 0.0608 Btu/lb F

COO
DOWTHERM

Suhu = 90.357 Celsius


= 194.643 Farenheit
Kapasitas panas
T1 200.0000 F
T2 210.0000 F
Cp 1 0.4260 Btu/lb F
Cp 2 0.4290 Btu/lb F
T 194.6426 F
Cp T 0.4244 Btu/lb F

Viskositas T avg Viskositas T wall


T1 200.0000 F T1 190.0000 F
T2 210.0000 F T2 200.0000 F
miu 1 1.0500 cP miu 1 1.1300 cP
miu 2 0.9800 cP miu 2 1.0500 cP
T 194.6426 F T wall 189.8062 F
miu T 1.0875 cP miu T wall 1.1316 cP

Densitas
T1 200.0000 F
T2 210.0000 F
Rho 1 62.1700 Btu/lb F
Rho 2 61.8800 Btu/lb F
T 194.6426 F
Rho T 62.3254 Btu/lb F SPGR = 1.0341

Konduktifitas thermal
T1 200.0000 F
T2 210.0000 F
k1 0.0733 Btu/lb F
k2 0.0728 Btu/lb F
T 194.6426 F
k saat T 0.0736 Btu/lb F

POMPA UTILITAS-04

Panjang pipa lurus = 1


3
41.4
2.5
0.5
0.5
1
22.5
1.36
0.6
0.5
2.88
58.9
1.94
0.5
0.5
Jumlah = 139.58 m
FURNACE
FUEL OIL

Menentukan densitas fuel oil


Degree API = 12.6
Densitas
Degrre API 1 10.0000 oAPI
Degrre API 2 15.0000 oAPI
Densitas 1 8.3280 lb/US gal
Densitas 2 8.0440 lb/US gal
Degree API 12.6000 oAPI
Den. Pd Degree API 8.1803 lb/US gal
COOLER
AIR

Suhu wall = 87.670 Celsius


= 360.670 Kelvin
Viskositas
Miu = exp (C1 + C2/T + C3 ln T + C4TC5) T [=] K
Komponen C1 C2 C3 C4 C5
H2 O -52.8430 3703.6000 5.8660 0.0000 10

Data untuk menghitung densitas


Komponen A B n Tc
H2 O 0.34710 0.27400 0.2857 647.13

Suhu 90.357 Celsius 363.357 Kelvin


ρ (g/cm3) =A(B^-(1-T/Tc)^n) T=K
Komponen (1-T/Tc)^n (B^-(1-T/Tc)^n) ρ (kg/L)
H2 O 0.7902 2.7814 0.9654
965.4203 kg/m3
60.2692 lb/ft3
POMPA UTILITAS-03

Tekanan uap
T1 325.0000 C Panjang pipa lurus
T2 330.0000 C
P1 3.6600 bar
P2 3.9600 bar
T 150.3500 C
P pd T -6.8190 bar

Densitas
T1 325.0000 C
T2 330.0000 C Jumlah
Rho 1 778.6000 kg/m3
Rho 2 772.8000 kg/m3
T 150.3500 C
Rho pd T 981.1940 kg/m3

Viskositas
T1 325.0000 C
T2 330.0000 C
Miu 1 0.1800 m Pa s
Miu 2 0.1800 m Pa s
T 150.3500 C
Miu pd T 0.1800 m Pa s
Miu [=] Pa.s
exp μ liq (cP)
-8.0377314 0.32304097
= 51.1
0.5
0.5
0.5
0.5
43
1.94
0.5
0.5
= 99.04