WSS Installation and User Manual
WSS Installation and User Manual
Table of contents
1. INTRODUCTION ......................................................................... 3
UNPACKING.................................................................................... 4
LEGAL INFORMATION AND RESPONSIBILITY ...................................... 4
2. MOUNTING THE WIND SENSOR ............................................. 5
PLACING OF THE WIND SENSOR...................................................... 5
BIRD AVOIDANCE KIT (OPTIONAL) .................................................... 7
3. CABLE CONNECTIONS............................................................. 8
THE WSS WIND SENSOR CABLE CONNECTIONS .............................. 8
CONNECTING A WSS OR WSS-L TO A WSDI-2 DISPLAY ................ 9
CONNECTOR KIT ASSEMBLY (OPTIONAL)....................................... 10
4. DIMENSIONS ............................................................................ 12
7. REFERENCES........................................................................... 19
1. Introduction
Important: Please be aware that the term WSS will represent both
WSS and WSS-L if no specific mentioning of the WSS-L is made.
Unpacking
The WSS sensor is delivered in a cardboard box. To protect the
delicate sensor heads, it is important to store it in the box until
mounting.
198.0
25.0
149.8
82.4
49.5
¾” pipe thread:
Outer diameter: 1.04 inch
(26.4mm), 14 threads per inch.
127.0
114.0
IMPORTANT!
The stainless steel mounting base on the WSS sensor
must be connected to earth (e.g. the steel hull).
The spike system is designed not to hurt birds, but simply create a
barrier to make it difficult for birds to land on top of the sensor.
Please note, that the kit does not provide complete protection against
birds, but especially large sea birds will not be able to land, while small
birds may still be able to squeeze inn. Small birds may interrupt the
wind measurement but will not be able to damage the sensor.
The shape and location of the spikes have been designed so that the
interference with wind measurements is negligible.
It is recommended to use the kit if there is a high accumulation of birds
in the area where the sensor is used.
3. Cable connections
The wind sensor is supplied with 2 metres fixed cable. From factory,
the cable is connected to the sensor via a waterproof gland, and this
must not be replaced by another cable. The cable can be extended by
using the connection box kit or the IP67 connector kit (both optional).
In order to protect the wind sensor and the personnel in the best
possible way from lightning strokes, use a lightning rod installed with
the tip at least one metre above the wind sensor. The lightning rod
must be properly grounded in compliance with all applicable safety
regulations. The wind sensor cable screen and the extension cable
screen must be connected.
For further protection of the cable between the wind sensor and the
connection box, as well as the installation cable between the
connection box and the interface box, it is recommended to use a
metal conduit pipe. If the instrument is installed in a metal panel, this
panel has to be carefully earthed, as well as the instrument itself.
WSS/WSS-L WSDI-2
DC power -
source + WSDI-2
1.
2.
Conn. ….
kit 7.
(Optional) 8.
9.
Ground (Earth) the sensor tap T
The data bus must be terminated
with the resistor supplied with the
WSDI-2
Male Female
connector connector
Plug Male 7 pin. Plug female 7 pin.
10 22 00 00 52 10 22 00 00 53
4. Dimensions
198.0
149.8
82.4
49.5
¾” pipe thread:
Outer diameter: 1.04 inch
(26.4mm), 14 threads per
inch.
127.0
114.0
Replacing 879.3c
Remove the tap for the old sensor 879.3c and mount the new sensor.
Notice that the tap is fixed on the new sensor and is not to be removed.
Mount the new sensor so the arrow on the bottom of the sensor is
pointing towards the stem of the ship.
The existing cable can be used. Before mounting the new sensor using
the existing cable, remember to disconnect the cable from the wind
display and check that the cable is not damaged.
The interface box can be mounted anywhere between the sensor and
the display(s), but the following must be taken into consideration: the
interface box has to be supplied from a 24V DC/1.25A source and
mounted indoor, for which reason it is recommended to mount the
interface box close to the existing display(s).
IMPORTANT!
The stainless steel mounting base of the WSS sensor
must be connected to earth (e.g. the steel hull).
4.5
99.7
75.0
61.0
85.0 110.0
6. Technical specification
Dimensions,
450 x 315 x 230
cardboard box
GL, DNV,
Type-approved according to:
Approvals CCS, RS and
(See www.deif.com for certificates and details)
GOST-R
Accessories IP66 Connection box kit: IP66 Connection box
w/ cable glands and screw terminals to extend
the sensor cable with an extension cable
7. References