0% found this document useful (0 votes)
194 views

Manual Agitador Orbital DLab

The document provides instructions for operating and maintaining a microplate mixer. It details safety precautions, proper use, inspection procedures, control features, maintenance, cleaning, associated standards and technical specifications. Warranty information is also included.

Uploaded by

Paulina Ríos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
194 views

Manual Agitador Orbital DLab

The document provides instructions for operating and maintaining a microplate mixer. It details safety precautions, proper use, inspection procedures, control features, maintenance, cleaning, associated standards and technical specifications. Warranty information is also included.

Uploaded by

Paulina Ríos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Microplate Mixer

User Manual
MX-M Microplate Mixer

Please read the User Manual carefully before


use, and follow all operating and safety
instructions!
Technical specifications and outline are subject
to change without prior notice.
www.dlabsci.com
Contents

Preface ................................................................................. 1
Service ................................................................................. 1
Warranty .............................................................................. 1
1. Safety Instructions ....................................................... 2
2. Proper use .................................................................... 3
3. Inspection .................................................................... 3
3.1 Receiving Inspection ............................................. 3
3.2 Listing of Items ..................................................... 3
4. Operation ..................................................................... 4
5. Control ......................................................................... 4
6. Maintenance and cleaning ........................................... 5
7. Associated standards and regulations .......................... 5
8. Technical data .............................................................. 6
9. Ordering information ................................................... 7
Preface Please provide the customer care representative with the
following information:
Welcome to the Microplate
“ Mixer User Manual”. Users ・ Serial Number(on the rear panel)
should read this Manual carefully, follow the instructions ・ Description of problem (i.e., hardware or software)
and procedures, and beware of all the cautions when using ・ Methods and procedures adopted to resolve the
this instrument. problems
・ Your Contact Information
Service
When help needed, you can always contact the service
Warranty
department of manufacturer for technical support. This instrument is warranted to be free from defects in
materials and workmanship under normal use and service,
for a period of 24 months from the date of Invoice. The
DLAB Scientific Instrument Inc.
warranty is extended only to the original purchaser. It shall
2311 E. Locust Court, Ontario, CA 91761 United States.
Office: +1-747-230-5179 not apply to any product or parts which have been damaged
Fax: +1-909-230-5275 on account of improper installation, improper connections,
Sales contact: [email protected] misuse, accident or abnormal conditions of operation.
Service contact: [email protected]
For claims under the Warranty please contact your local
www.dlabsci.com
supplier. You may also send the instrument directly to
manufacturer, enclosing the invoice copy and by giving
reasons for the claim. You would be solely liable for freight
costs.

1
1. Safety Instructions
Warning! - Overfilling of media
• Read the operating instructions in full before - Unsafe container
use and follow the safety instructions • Process pathogenic materials only in closed vessels.
• Ensure that only trained staff work with the • Always disconnect the plug before fitting accessories.
appliance. Do not use damaged components.
Protective ground contact! • The operating voltage required on the type plate and
• Make sure that socket is earthed (protective voltage supply network must match.
ground contact) before use. • Ensure that the mains power supply cable does not
• When work,wear the personal guard to avoid the risk touch the hotplate. Do not cover the instrument.
from: • Single microplate clamp and double microplate clamp
- Splashing of liquids. can not be changed more than 10 times, otherwise
- Release of toxic or combustible gases. increases the risk of screw slip.
• Set up the instrument in a spacious area on an even, • The instrument may only be opened by experts
stable, clean, non-slip, dry and fireproof surface, do Observe the minimum distances between the devices,
not operate the instrument in explosive atmospheres, between the instrument and the wall and above the
with hazardous substances or under water. assembly (min. 100 mm).
• Gradually increase the speed, reduce the speed if :
- The medium splashes out of the vessel because of
too high speed.
- The instrument is not running smoothly.
• Beware of hazards due to:
2
3. Inspection
>100mm
3.1 Receiving Inspection

Unpack the equipment carefully and check for any damages


which may have arisen during transport. If it happens,
>100mm please contact manufacturer/supplier for technical support.
Note:
If there is any apparent damage to the system,
please do not plug it into the power line.

3.2 Listing of Items


Figure 1
The package includes the following items:
2. Proper use Items Qty
Main unit 1
The instrument is designed for schools, laboratories or
Power adaptor 1
factories. This device is not suitable for use in residential
User Manual 1
areas or other areas that may cause danger to the user or
Table 1
instrument as mentioned in Chapter 1.

3
4. Operation 5. Control
• Make sure that the required operating voltage and
power supply voltage match. Adapter
• Ensure the power be off and the speed control knob at
the lowest position. Plug in the power adapter. Power LED
• Place a microtiter or other vessel in holder
• Power ON the device and the Power LED is lit
• Set the rated speed regulation and the device begins to
work..
• Set the rated speed regulation to „0‟and the device stop
to work. Speed control Knob

• Power OFF the device.


Figure 2
If these operations above are normal, the device is ready to
operate. If these operations are not normal, the device may
be damaged during transportation, please contact technical
support of manufacturer/supplier.

4
6. Maintenance and cleaning initial packaging carton before sending to service for
repair, avoiding the contamination of hazardous.
Proper maintenance can keep instruments working in a
• Switch off the device and put it in the dry, clean, stable
good state and lengthen its lifetime. Be careful not spray the place at room temperature in long-term disuse.
cleanser into the instrument when cleaning.
Unplug the power line when cleaning. Only use cleanser
that we advised as below: 7. Associated standards and
regulations
Dyes isopropyl alcohol
Construction in accordance with the following safety
Construction materials water containing tenside
standards:
/ isopropyl alcohol
EN 61010-1
Cosmetics water containing tenside
/ isopropyl alcohol Construction in accordance with the following EMC
standards:
Foodstuffs water containing tenside
EN 61326-1
Fuels water containing tenside
Associated EU guidelines:
• Before using other method for cleaning or
decontamination, the user must ascertain with the EMC-guidelines: 89/336/EWG
manufacturer that this method does not harm or Machine guidelines: 73/023/EWG
destroy the instrument.
• Wear the proper protective gloves during cleaning of
the instrument.
• Forbid to place the instrument in the cleanser to clean.
• The instrument must be cleaned and put it into the
5
8. Technical data Items Parameters
1
Items Parameters
Microplate amount 2 (Double microplate
Voltage [VAC] 100~240 clamp)
Frequency [Hz] 50/60 Dimensions (mm) 260×150×80
Power [W] 20 Weight [kg] 3
Shaking movement Orbital Permitted ambient
5-40
Orbital diameter [mm] 4.5 temperature[°C]
Max. shaking weight (with Permitted relative humidity 80%
0.5
attachments) [kg] Protection class acc. to DIN
IP21
External rotor brushless 60529
Motor type
motor Table 2
Motor rating input [W] 18
Motor rating output [W] 10
Permissible ON time [%] 100
0-1500
Speed range [rpm] 0-1000 (Double
microplate clamp)
Speed display Scale
Microplate working Yes

6
9. Ordering information 1.2/PS1.1
VT1.3.3 Tube adapter, for 12 holes test
Cat. No Descriptions 18900022 tubes, Ø12mm , used with VT 1.3/ VT
MX-M Microplate Mixer with 1.2/PS1.1
822000017777 Microplate clamp, Cn plug, 100-240V,
VT1.3.4 Tube adapter, for 8 holes test
/50Hz/60Hz
18900023 tubes, Ø16mm, used with VT 1.3/ VT
MX-M Microplate Mixer with 1.2/PS1.1
822000027777 Microplate clamp, Euro plug,
VT1.3.5 Tube adapter, for 8 holes test
100-240V, 50Hz/60Hz
18900024 tubes, Ø20mm, used with VT 1.3/ VT
MX-M Microplate Mixer with 1.2/PS1.1
822000037777 Microplate clamp, UK plug, 100-240V,
18900042 PS1.2 Microplate clamp
50Hz/60Hz
18900079 MXM-116 Double microplate clamp
MX-M Microplate Mixer with
Table 3
822000047777 Microplate clamp, USA plug,
100-240V, 50Hz/60Hz
Accessories
PS1.1 Universal top plate(round),used
18900067
with VT1.3.1--5
VT1.3.1Tube adapter, for 48 holes test
18900020 tubes, Ø6mm, used with VT 1.3/ VT
1.2/PS1.1
VT1.3.2 Tube adapter, for 18 holes test
18900021
tubes, Ø10mm, used with VT 1.3/ VT
7
DLAB Scientific Instrument Inc.
2311 E. Locust Court, Ontario, CA 91761 United States.
Office: +1-747-230-5179
Fax: +1-909-230-5275
Sales contact: [email protected]
Service contact: [email protected]
www.dlabsci.com

You might also like