Department of Civil Engineering Test Report of Concrete Mix Design

1. The mix design was conducted to achieve a target compressive strength of 30 MPa at 28 days for severe exposure conditions. 2. Laboratory tests were performed on the cement, fine aggregate, and coarse aggregate to determine their properties. 3. A trial mix proportion was developed that met the strength and workability requirements, with a water-cement ratio of 0.45, cement content of 400 kg/m3, and a slump value between 50-75 mm.

Uploaded by

supreetha k s
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
201 views

Department of Civil Engineering Test Report of Concrete Mix Design

1. The mix design was conducted to achieve a target compressive strength of 30 MPa at 28 days for severe exposure conditions. 2. Laboratory tests were performed on the cement, fine aggregate, and coarse aggregate to determine their properties. 3. A trial mix proportion was developed that met the strength and workability requirements, with a water-cement ratio of 0.45, cement content of 400 kg/m3, and a slump value between 50-75 mm.

Uploaded by

supreetha k s
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

AITECH Adichunchanagiri Shikshana Trust (Regd.

) Estd: 1980

(Accredited by NAAC., ISO 9001:2000 Certified)


(Affiliated to Visveswaraya Technological University, Belgaum,
Recognised by A.I.C.T.E. New-Delhi and Government of Karnataka)
P.B. No. 91, Adichunchanagiri Extension, Chikmagalur-577102
Std : 08262,Off : 220444 Email : [email protected]
Pr inc ipal : 220063, R e s i : 220343 Fa x : 22006 3 We bs ite : aitc km .in

Department of Civil Engineering

Test Report of Concrete Mix Design


(As per IS: 10262-2019)

Organization: Assistant Executive Engineer, KUWS and D.Board, Sub-Division,


Chikkamagaluru (M.N.Ramakrishna)

Project: Construction of 5.00 LL OHT on 12 m staging at TDS layout in Kadur Town under
Nagarottana works

You’re Ref NO: Dated: 24/11/2020

Design Stipulations:
Following are the provisions made in the mix design as specified by the client for
designing M 30 concrete.
1. Characteristic cube compressive strength required
in the field at 28 days. : 30 N/mm2
2. Maximum size of coarse aggregate : 20 mm, angular
3. Degree of workability in terms of Slump Value : 50 mm to 75 mm
4. Degree of quality control : Good
5. Exposure condition : Severe
6. Chemical admixtures : SP (Master Glenium sky 8233)
Confirming to IS 9103 is
recommended

Laboratory Test results


Based on IS: 2386 (Part-III), 1963, the following are the test results.

Cement
• Cement used is Ordinary Portland C emen t of brand Chettin ad 43 Grad e
cemen t satisfying the requ iremen ts of IS: 269 -2015
• Specific gravity of cement :3.13

Fine Aggregates
• Specific gravity of fine aggregate :2.62
• Fine aggregate conf irms to Zone II of IS: 383 – 2016

Coarse Aggregates
• Specific gravity of coarse aggregate :2.71
AITECH Adichunchanagiri Shikshana Trust (Regd.) Estd: 1980

(Accredited by NAAC., ISO 9001:2000 Certified)


(Affiliated to Visveswaraya Technological University, Belgaum,
Recognised by A.I.C.T.E. New-Delhi and Government of Karnataka)
P.B. No. 91, Adichunchanagiri Extension, Chikmagalur-577102
Std : 08262,Off : 220444 Email : [email protected]
Pr inc ipal : 220063, R e s i : 220343 Fax : 22006 3 We bs ite : ait c km .in

Department of Civil Engineering

Target Mean Strength of Concrete: As per IS: 10262 -2019, the target mean
strength at 28 days for M30 concr ete mix is 36.6 N/mm 2 . Concrete mix es for
target mean streng th are design ed as per th e above code, and the proportions
for one cubic meter of con crete are calcu lated. The maximum water cement
ratio for moder ate exposure and R.C.C.is 0.45 and minimu m cement con ten t
is 320.00 kg/m 3 as per IS: 456-2000. The water content is adjusted and the
modified propor tion is suggested which g ives the required workab ility and
strength. Specif ication of IS: 10262 -2019 is followed.
From Table 4 of IS 10262 -2019, maximu m water content is 191.58 kg/m 3
(For 50 mm to 75 mm slu mp) for 20mm and down size aggregate. As Super
Plasticizer is used the water conten t is may be reduced up to 20% and abov e.
The water considered is 172.42 kg/m 3 for this mix. Cemen t content will be
360.00 kg/m 3 for the consider ed w/c ratio and water content.
Using the design steps and formu lae g iven in IS: 10262 – 2019, the
fine aggreg ate and coarse aggr egate contents are deter mined as,
Fine aggregate : 699.33 kg/ m 3
Coarse aggregate (20 mm Downsize -60%) : 693.28 kg/ m 3
Coarse aggregate (12 mm Downsize-40%) : 462.19 kg/ m 3

Thus the trail mix proportion is tabulated as follows.


Chemical Cement Fine
Water, Coarse aggregate in
Mix 3 admixtur e in aggregate in
kg./m kg/m 3
kg./m 3 kg/m 3 kg/m 3

M30 172.42 8.0 400.00 699.33 1155.48


AITECH Adichunchanagiri Shikshana Trust (Regd.) Estd: 1980

(Accredited by NAAC., ISO 9001:2000 Certified)


(Affiliated to Visveswaraya Technological University, Belgaum,
Recognised by A.I.C.T.E. New-Delhi and Government of Karnataka)
P.B. No. 91, Adichunchanagiri Extension, Chikmagalur-577102
Std : 08262,Off : 220444 Email : [email protected]
Pr inc ipal : 220063, R e s i : 220343 Fax : 22006 3 We bs ite : ait c km .in

Department of Civil Engineering

MIX PROPORTION RECOMMENDED


Dosage of
Average
3
Chemical
Quantities of materia ls per m . compressive
Trial admixture Workability Visual
of concrete in terms of strength
mix - observation
Slump N/mm 2
no. of the mix
SP Value
7 28
W C FA CA
days days
172.4 1155.4
400.0 699.33
2 8 8.0 50mm to
M30 kg/m 3 24.34 37.50 Cohesive
75mm
Proportions: 1: 1.75:2.90

The above Mix is designed using co mbination of coarse aggreg ate retain ed
and passing through 20mm and 10 mm sieve respectively. The designed mix
is based on saturated and surface dry condition of aggregates.

CONCLUSION: The designed mix gives th e required str ength and workability
as required. Hence it can b e adop ted in the field. The mixes are d esigned b y
doing some modif ications to s atisfy the req uiremen ts. The mixes ar e design ed
for SSD condition of the aggr egates and for the given materials only.

Staff in Charge Head of the Department