8-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT
8-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT
at Boresight
Cross Polar Discrimination dB > 15.5 > 15.5 > 10.5
over Sector
Vertical Pattern:
Elevation Beamwidth ° 5.0 ± 0.2 4.7 ± 0.2 4.5 ± 0.3
Electrical Downtilt ° 0.0 – 6.0
continuously adjustable
Tilt Accuracy ° < 0.2 < 0.3 < 0.3
First Upper Side Lobe dB > 12 > 17 > 18
Suppression
Cross Polar Isolation dB > 30
Port to Port Isolation dB > 30 (B2 // R1, R2, B1)
Max. Effective Power W 250 (at 50 °C ambient temperature)
per Port
Max. Effective Power W 500 (at 50 °C ambient temperature)
Port 7–8
Values based on NGMN-P-BASTA (version 9.6) requirements.
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
8-Port Antenna
85010002 1 clamp Mast diameter: 110 – 220 | 4.3 – 8.7 2.7 | 6.0 2
85010003 1 clamp Mast diameter: 210 – 380 | 8.3 – 15.0 4.8 | 10.6 2
85010008 1 downtilt kit Downtilt angle: 0° – 11° 6.5 | 14.3 1
Accessories (included in the scope of supply)
738546 1 clamp Mast diameter: 42 – 115 | 1.7 – 4.5 1.1 | 2.4 2
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.
936.4864/c ngmn 04.19.02.04 Subject to alteration.
Wall mounting with two half clamps 738546 (included in the scope of supply).
1934 | 76.1
1966 | 77.4
2006 | 79.0
Grounding: The metal parts of the antenna including the mounting and the inner
conductors are DC grounded.
Adjustment mechanism
with integrated scale
Layout of interface:
0
T
0
Tilt
t
17
99 | 3.9
110 | 4.3
Tilt
133 | 5.2 *
4)
56 | 2.2
34 | 1.3
1) 2)
270 | 10.6 3)
1) 33.5 | 1.3
476 | 18.7 2) 35.5 | 1.4
3) 50 | 2.0
576 | 22.7 * 4) 45 | 1.8
Bottom view
* Dimensions refer to radome
All dimensions in mm | inches
Correlation Table
Frequency range Array Connector
936.4864/c ngmn 04.19.02.04 Subject to alteration.
B1 B2
R1 R2
Left Right
152 [5.98]
100 [3.94]
[0.79–0.98]
40 [1.57]
72 [2.83]
20–25
40 [1.57]
15
2–1
4 4.53]
5–
[1.6
M10 MA = 25 Nm
M8 MA = 20 Nm
35 [1.38]
64 [2.52]
125 [4.92]
20–25
[0.79–0.98]
Subject to alteration.
936.3920/c
Please note: Kathrein does not recommend to use counter nuts. All dimensions in mm and [inches]
The additional nuts supplied are only meant as spares.
1
2
2
➀ Twist protection. ➀ Thread for fixing the protective To set the downtilt angle exactly,
➁ Downtilt spindle with integrated cap or the RCU (Remote Control you must look horizontally at the
scale. Unit). scale. The lower edge of the gear-
➁ Gearwheel for RCU power drive. wheel must be used for alignment.
0° – max.°
0° – max.°
Remove the protective cap and the Set downtilt angle by rotating the Screw on the twist protection and
twist protection completely. gearwheel. the protective cap again.
For a description of RCU installation please refer to the respective data sheet.
All specifications are subject to change without notice.
The latest specifications are available at www.kathreinusa.com Page 1 of 2
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]
General Instructions
for Feederline and RCU Installation
for Antennas
Please note: In order not to damage the interfaces, please make sure that only the right tools are used.
Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench
width.
Adjustment mechanism
(protective cap removed) Ventilation hole
Colour coding:
Correlation of each RF input to:
– the corresponding adjustment mechanism
7-16 female (long neck) – the frequency range
– the polarization
32 | 1.3
Subject to alteration.
guidelines). 41
| 1.
1
These tools are suitable for 7-16 connectors with a wrench size of
27 or 32 mm | 1.1 or 1.3 inches, and the RCU attachment nut with a
wrench size of 41 mm | 1.6 inches.
Tighten nuts within a torque range of 25 – 33 Nm depending on
connector manufacturers’ specifications, respectively the RCU nut
with a torque range of 15 – 18 Nm.