"Transmission Drive Pump Pressure Override Calibration": Illustration 1 g02500239 Cat ET Calibrations Menu
"Transmission Drive Pump Pressure Override Calibration": Illustration 1 g02500239 Cat ET Calibrations Menu
Calibration should be performed if the ECM has been removed or replaced and if the applicable components have been removed or replaced.
The solenoids and position sensors that are under the control of the Machine ECM can be calibrated by using the Caterpillar Electronic Technician
(Cat ET).
Illustration 1 g02500239
Cat ET Calibrations Menu
To access the calibration procedures for the Machine ECM, establish the connections of the Cat ET to the Machine ECM. Navigate to the
calibration screen by clicking "Service" on the tool bar and then clicking "Calibrations". Click on the calibration that is needed.
Once the specific calibration is selected, the Cat ET will guide you through the calibration procedure.
The Cat ET will list initial machine conditions that must be satisfied before the ECM will allow the calibration procedure to continue. Follow the
specific instructions on the display in order to complete the calibration procedure successfully.
Note: The "CALIBRATION REQUIRED" diagnostic will be active if either the operator or the ECM aborts any of the calibrations. The ECM will revert to
the previous successful calibrated values. In order to clear the diagnostic, key cycle the machine.
The following list details the calibrations that can be performed for the hystat components on the Machine ECM.
Note: For information on implement calibrations, refer to Testing and Adjusting, , KENR5705, "Calibration".
Navigate to the Cat ET calibration screen by clicking "Service" the tool bar and then clicking "Calibrations". Click "Transmission Drive Pump
Pressure Override Calibration".
Note: The transmission must be operated in FORWARD and in REVERSE for 5 seconds in each direction between consecutive pressure override
calibrations.
Illustration 2 g02490056
Cat ET Transmission Drive Pump Pressure Override Calibration Sequence
The minimum average of the left and right is determined for the calibration point
See Illustration 2.
If one or both of the average calculations are outside of the calibration range, a calibration error will occur. Refer to Table 1 for additional
information of each error code.
Cat ET Error Codes for Transmission Drive Pump Pressure Override Calibration
Error ID and Description Reasons for the Error Code Recommended Response/Possible Cause
"10F7 - Hydrostatic Transmission Neutral Motor speed is detected during Pressure Override Parking Brake is not holding machine when
Interlock Active" calibration stalling against the brakes.
Check and adjust the setting for the crossover
One of the "Crossover Relief" pressures was out relief valve.
Table 1
____________________
The following components are utilized during the "Hystat Pump and Motor Solenoid Calibration":
Motor Solenoids
Navigate to the Cat ET calibration screen by clicking "Service" the tool bar and then clicking "Calibrations". Click "Hystat Pump and Motor Solenoid
Calibration". A "Select Components to Calibrate" popup box will be visible. See Illustration 3.
Illustration 3 g02490096
"Select Components to Calibrate"
Note: Select both the forward and reverse components in order to perform a complete calibration.
The "Forward Pump and Motor Solenoid Calibration"determines the minimum and maximum solenoid currents for the following:
The "Reverse Pump Solenoid Calibration" determines the minimum and maximum currents for the left and right reverse pump solenoids.
"Minimum Pump Current" - minimum current flow to the forward and reverse solenoids on the left and right pumps, to start moving the tracks
"Maximum Pump Current" - maximum current flow to the forward and reverse solenoids on the left and right pumps, required to fully stroke
the pumps
"Minimum Motor Current" - minimum current flow to the left and right motor solenoids, required to start destroking the motor
"Maximum Motor Current" - maximum current flow to the left and right motor solenoids, needed to achieve a predetermined machine speed
Illustration 4 g02490117
Cat ET Hystat Pump and Motor Calibration Intervals
Illustration 5 g02490119
Cat ET Hystat Pump Calibration Sequence
1. Hystat pump calibration begins. The pump current steps up to the low end of the "Pump Minimum Calibration Range". Pump current is slowly
increased until a motor speed is detected. Current is then decreased until the motor speed returns to zero. This current is the "Pump
Minimum Calibration Current".
If the motor speed is detected immediately during the start of the calibration, the following error codes may be seen in Cat ET:
Refer to Table 2 for a list of possible reasons and causes of these Cat ET error codes.
3. "Pump Maximum Gear Ratio" is recorded. "Gear Ratio = Motor Speed / Pump Speed"
If the Pump Maximum Gear Ratio is outside the low end of the calibration range, the following error codes may be seen in Cat ET:
Illustration 6 g02490126
Cat ET Hystat Motor Calibration Sequence
6. Motor calibration begins. The pump is ramped up to full current with a reduced engine speed.
7. Motor current steps up to the low end of the "Motor Minimum Calibration Range". Motor current is slowly increased until there is a change in
motor speed.
If motor speed immediately jumps up at the low end of the calibration range, the following error codes may be seen in Cat ET:
8. Motor current is slowly increased until the "Gear Ratio" value equals the target.
If the target "Gear Ratio" is not reached in the "Motor Maximum Calibration Range", the following error codes may be seen in Cat ET:
Illustration 7 g02490129
Example of Cat ET Error Code
Note: A common root cause of a failed "Hystat Pump and Motor Solenoid Calibration" is contamination of the solenoids, pump, or motor
controllers. Contamination will restrict motion and/or cause hysteresis and will prevent a steady gear ratio to be attained during calibration. If the
calibration fails, do NOT adjust the "Min" or "Max" stops of the forward or reverse pumps. Refer to Table 2 for additional information of each error
code.
Cat ET Error Codes for Hystat Pump and Motor Solenoid Calibration
Error ID and Description Reasons for the Error Codes Possible Causes
· "Pump Null"
"10D4 - Left Pump Minimum adjustment may be off
Occurs while the motor current is outside the lower end of the calibration range.
"10E6 - Right Motor Minimum · Sticking solenoid
Current Out of Range Low"
"10E1 - Left Motor Minimum
· Contamination in
Current Out of Range High"
Motor does not start to destroke off the "Max Displacement ". Occurs while the motor motor control
current is outside the upper end of the calibration range. · Sticking solenoid
"10E7 - Right Motor Minimum
· Low charge pressure
Current Out of Range High"
"10E2 - Left Motor Maximum
Current Out of Range Low"
Motor is destroked and the displacement is smaller than the expected result. Occurs · Contamination in
"10E8 - Right Motor while the motor current is outside the lower end of the calibration range. motor control
Maximum Current Out of
Range Low"
· Contamination in
motor control
"10E3 - Left Motor Maximum · "Motor Min
Current Out of Range High" Displacement" stop is
Motor does not destroke to a displacement that is small enough to reach the target. set too high.
"10E9 - Right Motor Occurs while the motor current is outside the upper end of the calibration range. · Pump is not at
Maximum Current Out of maximum
Range High" displacement
· Sticking solenoid
· Low charge pressure
· Contamination in
motor control
"10E4 - Left Motor Maximum · "Motor Min
Gear Ratio Out of Range Low" Displacement" stop is
Motor does not destroke to a displacement that is small enough to reach the target. set too high.
"10EA - Right Motor Occurs while the motor current is outside the upper end of the calibration range. · Pump is not at
Maximum Gear Ratio Out of maximum
Range Low" displacement
· Sticking solenoid
· Low charge pressure
"10E5 - Left Motor Maximum
Gear Ratio Out of Range
· Contamination in
High"
motor control
Motor is at a displacement which is much lower than the maximum displacement. · "Motor Min
"10DF - Right Pump Displacement" stop is
Maximum Gear Ratio Out of set too low
Range High"
Table 2
____________________
Brake/Decel Pedal
Navigate to the Cat ET calibration screen by clicking "Service" the tool bar and then clicking "Calibrations". Click "Hystat Operator Control
Calibrations".
Note: If a "103 - Calibration Out of Range" error code occurs during calibration, check the PWM signal to ensure that communication is working
correctly.
PPT-01014C1D
2021/06/21
10:50:54+08:00