Module Temperature SENSOR TM-I-4090 With Signal Converter: Item No.: 423.017

The module temperature sensor TM-I-4090 is equipped with an aluminum housing and weatherproof cable. It measures temperature from -40 to +90°C with an accuracy of ±1K and outputs a 4-20mA signal. It is powered by 12-28V DC and is ideal for industrial and outdoor applications. The sensor is attached using glue and has an IP67-rated enclosure, with the option to provide additional sun/rain protection if mounted outdoors.

Uploaded by

Solar Projects
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
217 views

Module Temperature SENSOR TM-I-4090 With Signal Converter: Item No.: 423.017

The module temperature sensor TM-I-4090 is equipped with an aluminum housing and weatherproof cable. It measures temperature from -40 to +90°C with an accuracy of ±1K and outputs a 4-20mA signal. It is powered by 12-28V DC and is ideal for industrial and outdoor applications. The sensor is attached using glue and has an IP67-rated enclosure, with the option to provide additional sun/rain protection if mounted outdoors.

Uploaded by

Solar Projects
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MODULE TEMPERATURE

SENSOR TM-I-4090
WITH SIGNAL CONVERTER
Item No.: 423.017

DESCRIPTION OF FUNCTIONS The module temperature sensor Tm-I-4090 is equipped with a stable aluminium housing and a
robust weatherproof cable. Due to the use of top quality components the sensor achieves very
high accuracy and is ideal for use in industrial and field environments.
The sensor gets shipped with a calibration protocol for the measuring amplifier.

TECHNICAL DATA

Power supply: 12…28 V DC


Current consumption: max. 25 mA
Sensor element: PPT 1000 Class A as per EN 60751
Measuring range: -40…+90 °C
Measurement uncertainty: ±1 K (at -40…+80 °C)
Output signal: 4...20 mA

DATA LOGGER

Type: Current measurement


Gradient: 8.125
Offset: -72.5
Abbreviation: T

INSTALLATION

Installation: Mounting by glueing the aluminium block directly on to the measurement surface.
It is recommended to use an extra fixing with silicon or Sikaflex
Position: If mounted outdoors, avoid direct exposure to sunlight and rain to the sensor housing
(aluminium block). If necessary, provide protection from the sun and rain.
Sensor housing: Self-adhesive aluminium block
Enclosure signal converter: Powder-coated aluminium
IP protection class: IP 67 (enclosure signal converter)
Operating temperature: -40…+80 °C
Enclosure dimensions (W x H x D): 64 x 58 x 34 mm
Weight: overall appr. 350 g
Connection cable: 3 m length, PUR coated, shielded (LiHC11Y, 4 x 0.14 mm²)
Sensor cable: 3 m length, PUR coated, shielded (LiHC11Y, 2 x 0.25 mm²)
Max. cable length: 200 m (with a cable 4 x 0.5 mm²)
Assignment of connections:
Power supply Plus = red, Minus = black
Temperature brown

Information subject to change, errors and omissions excepted / as of 09-2018 1|2


SCALE DRAWING

Mount ing hole


36 m m 64 m m
ø 4.5 m m - 2x

46 m m 58 m m

Further information: www.meteocontrol.com

Information subject to change, errors and omissions excepted / as of 09-2018 2|2