Weighing Indicator
INSTRUCTION MANUAL
1WMPD4003050E
WARNING DEFINITIONS
The warnings described in this manual have the following meanings:
The contents of this manual and the specifications of the instrument covered by this manual are
subject to change for improvement without notice.
CONTENTS
1. SAFETY PRECAUTIONS................................................................................................4
6. CALIBRATION...............................................................................................................11
6.1. Calibration Setting..................................................................................................11
6.2. Calibration Using Calibration Weights ..................................................................12
Page 1 AD-4401A
11. SETPOINT INPUT .......................................................................................................34
11.1. Pin Assignment ....................................................................................................34
11.2. Connection Diagram.............................................................................................37
AD-4401A Page 2
18. SETPOINT SETTING ..................................................................................................66
18.1. Setting Using Key Switches................................................................................66
18.2. Setpoint Values List.............................................................................................68
22. SPECIFICATIONS.......................................................................................................92
Page 3 AD-4401A
1. SAFETY PRECAUTIONS
For safe and correct usage, read the following precautions carefully before using the indicator.
Precautions on designing
WARNING
● Provide an external safety circuit to the indicator so that the safety of the whole system can be
secured even if errors occur in the external power supply or in the indicator.
Precautions on installation
WARNING
● Do not use the indicator in the following environment:
- where the temperature and the humidity exceed the specifications
- where corrosive gases or flammable gases exist
- where the indicator gets wet with oil, chemicals or water
Please note that securing the indicator to the control panel will provide the indicator outside of the
control panel the IP65 protection.
● When installing or removing the indicator, be sure to turn off all the external power supplies used
beforehand.
Precautions on wiring
WARNING
● When wiring the indicator, be sure to turn off all the external power supplies used beforehand.
● When wiring is complete, be sure to attach the terminal block cover provided with the indicator.
● Be sure to earth ground the indicator.
CAUTION
● Do not clamp control wires or communication cables with power lines, or do not place them close to
power lines.
● Place the load cell cable sufficiently away from high frequency circuits such as high voltage power
lines and inverter load circuit.
AD-4401A Page 4
2. PART NAMES
2.1. Front Panel 8
2 3
5
6 7
No. Name
1 Main
Numerical
2 Sub
Display
3 Unit
ZERO
STABLE (MD: Motion detection)
GROSS
Status Display
4 NET
(Upper)
HOLD
FUNCTION (FncF-05)
ALARM
Normal batching Loss-in-weight batching Check weighing
Final weight Final weight Near-zero (Z.BAND)
Free fall Free fall Lo-Lo
Preliminary Preliminary Lo
Status Display
Optional preliminary Full Go
(Lower) 5
Overweight Overweight Hi
Underweight Underweight Hi-Hi
Near-zero (Z.BAND) Near-zero (Z.BAND)
Attach the accessory status label when performing loss-in-weight batching
or check weighing.
6 CAL (Calibration) key
SETPOINT
ZERO
TARE
Key Switches
7 NET/GROSS
Function (FncF-02)
ENTER
ON/OFF
8 Rating label (Accessory)
Other
9 Sealing cover
Page 5 AD-4401A
2.2. Rear Panel
1 2 3
4
8
9
5 6 7
No. Name
1 SETPOINT input connector
2 CONTROL I/O connector
3 SER.OUT (Standard serial output) connector
4 Option slot
5 Load cell input terminal block
6 Optional analog 4-20 mA output terminal block
7 AC power input terminal block
8 Protective conductor terminal
9 Slide rail
2.3. Accessories
Name Quantity
Terminal block cover 1
Terminal block cover securing screw 2
Connector for the CONTROL I/O 1
Connector for the SER.OUT 1
Panel mount packing 1
Rubber foot 4
Rating label 1
Status label 1
AD-4401A Page 6
3. INSTALLATION TO CONTROL PANEL
Make a hole in a control panel as shown below.
138 +1
-0
68 +1
-0
Panel thickness: 1.6 to 3.2
Unit: mm
Remove the slide rails on both sides and insert the AD-4401A with the accessory packing through the hole
into the panel.
Page 7 AD-4401A
4. CONNECTION TO POWER SUPPLY
4.1. AC Power Input Terminal Assignment
11 Ground terminal
Live
Neutral
AD-4401A Page 8
5. CONNECTION TO LOAD CELL
5.1. Load Cell Input Terminal Assignment
Page 9 AD-4401A
5.2. Connection Diagram
●6-wire connection
Shield
Sensing +
Load cell excitation voltage +
●4-wire connection
As shown in the figure below, short-circuit the pins No.1 and No.2, and pins No.3 and No.4.
Shield
AD-4401A Page 10
6. CALIBRATION
Calibrates the AD-4401A to convert the signal from the load cell to a mass value correctly.
●Unit: (CALF-01)
Select the unit of the scale.
0: None, 1: g, 2: kg, 3: t, 4: lb (For USA only)
Once the calibration using calibration weights has been completed, the following calibration functions are
automatically set.
●Load cell signal voltage at zero calibration: (CALF-15)
●(Load cell signal voltage at span calibration CALF-15) CALF-17 / Calibration weight value at span
calibration: (CALF-16)
●Maximum capacity at span calibration: (CALF-17)
●Calibration weights at span calibration via Modbus: (CALF-23)
Calibration is also performed without calibration weights by setting the load cell signal voltage corresponding
to the calibration weight value (Digital span).
Page 11 AD-4401A
6.2. Calibration Using Calibration Weights
Zero calibration
Press the ENTER key when the STABLE (MD) status
is turned OFF.
Dashes are displayed in the sub-display and zero
calibration is performed.
Note: When the Function key is pressed, the AD-
4401A proceeds to the span calibration without
performing zero calibration.
Span calibration
Set the calibration weight value in the sub-display.
Press the ENTER key when the STABLE (MD) status
is turned OFF.
AD-4401A Page 12
Error List
C Err Description
The load cell signal voltage at zero calibration exceeds 2 mV/V.
2
Check if unnecessary load is applied to the load cell.
The load cell signal voltage at zero calibration is less than 0 mV/V.
3
Check if load cell connections of SIG+ and SIG- are not reversed.
The calibration weight value that is set in the span calibration exceeds the maximum capacity.
4
Set the calibration weight value to less than the maximum capacity.
The calibration weight value that is set in the span calibration is less than the minimum
5 division.
Set the calibration weight value to greater than the minimum division.
The load cell signal voltage at span calibration is less than that at zero calibration.
7
Check the load cell wiring.
The load cell signal voltage at span calibration exceeds 3.2 mV/V.
8
Check if unnecessary load is applied to the load cell.
Page 13 AD-4401A
7. BASIC WEIGHING FUNCTIONS
When the AD-4401A is powered ON, all the segments of the display turn ON and OFF for checking the
display. Then the AD-4401 is in the normal mode and starts weighing.
If the AD-4401A is powered OFF in the OFF mode (with the display OFF), the AD-4401A is in the OFF mode
when powered ON.
For the function setting procedure, refer to "21.1. Calibration Function Setting" and "21.2. General Function
Setting".
●Main display
The contents in the main display in the normal mode are as follows.
- Weight value
- Positive overload
- Negative overload
●Sub-display
Select the function of the sub-display (FncF-04) from the following:
Gross value, Net value, Tare value, Final weight, Total weight, Number of accumulations, Weighing
sequence error
●Zero setting
The gross value is set to zero when the weight value is within the zero setting range (CALF-05).
Operation: ZERO key, Control input
Setting: Tare and zero setting at unstable weight. (CALF-10)
●Zero clear
The zero setting value is cleared.
Operation: Function key (FncF-02), Control input
AD-4401A Page 14
●Zero tracking
The gross value is set to zero automatically when the zero tracking time (CALF-06) has passed while the
gross value is maintained within the zero tracking width (CALF-07).
Note: The function is enabled only when the gross value is within the zero setting range (CALF-05).
●Tare
The current gross value is saved as a tare value and the net value is set to zero.
Operation: TARE key, Control input
Setting: Tare and zero setting at unstable weight (CALF-10) / Tare at negative gross value (CALF-11)
●Tare clear
The tare value is cleared.
Operation: Function key (FncF-02), Control input
●Zero
Center of zero is detected and the ZERO status turns ON when the gross value is within 1/4 of the minimum
division.
●Stable
Stability is detected when the weight value is maintained within the stability detection width (CALF-09) during
the stability detection time (CALF-08). The STABLE (MD) status turns OFF. The control output that is set to
“Stable” turns OFF.
●Hold
The weight value is temporarily locked / released. The HOLD status turns ON while the weight value is
locked.
Operation: Function key (FncF-02), Control input
Select a hold function (FncF-08) from the following:
- Normal hold: The value when the holding operation is performed is locked.
- Peak hold: The maximum value after the holding operation is locked.
Setting: Comparison at hold (FncF-09)
Page 15 AD-4401A
●Manual print
Data is output from the standard serial output or options (BCD, RS-232C, RS-422/485).
Operation: Function key (FncF-02), Control input
●Accumulation
The net value is accumulated on the total weight and the number of accumulations is updated.
Operation: Function key (FncF-02), Control input
●Total clear
The total weight and the number of accumulations are cleared.
Operation: Function key (FncF-02), Control input
●Undoing accumulation
The weight value accumulated last is subtracted from the total weight.
Operation: Function key (FncF-02), Control input
●Alarm
Select the condition to turn the ALARM status ON (FncF-10) from the following:
- Overload
- Total weight / number of accumulations overflow
- Zero setting error
- Tare error
- Weighing sequence error
AD-4401A Page 16
8. BATCH WEIGHING FUNCTIONS
Batch weighing is a procedure to automatically weigh the final weight.
Select a weighing mode (CALF-14) from the following:
1: Simple comparison normal batching
2: Simple comparison loss-in-weight batching
3: Normal batching (default)
4: Loss-in-weight batching
Feeding process
1. The weighing start input is detected.
2. When the weighing start input delay time (Sq F-09) has passed, the large flow, medium flow and small
flow outputs turn ON.
3. When the large flow comparison disable time (Sq F-10) has passed and the net value has exceeded the
optional preliminary value, the large flow output turns OFF.
4. When the medium flow comparison disable time (Sq F-11) has passed and the net value has exceeded
the preliminary value, the medium flow output turns OFF.
5. When the small flow comparison disable time (Sq F-12) has passed and the net value has exceeded the
free fall value, the small flow output turns OFF.
6. When the judging delay time (Sq F-13) has passed and the net value is stable (Sq F-07), the net value
is judged.
●Discharge start
Operation: Function key (FncF-02), Control input
Discharging process
1. The discharge start input is detected.
2. When the discharge start input delay time (Sq F-18) has passed, the discharge output turns ON.
3. When the gross value is below the near-zero value and the discharge end delay time (Sq F-19) has
passed, the discharge output turns OFF.
Page 17 AD-4401A
●Near-zero
When the weight value is compared with the setpoint and the condition is met, the control output turns ON.
Timing chart
Judge
Overweight
Final weight
Free fall
Underweight
Preliminary
Optional
Preliminary
Near-zero
Gross
Net
Near-zero output
Discharge output T8
T1: Weighing start input delay time T5: Judging delay time
T2: Large flow comparison disable time T6: Weighing end output time
T3: Medium flow comparison disable time T7: Discharge start input delay time
T4: Small flow comparison disable time T8: Discharge end delay time
AD-4401A Page 18
●Correction flow
When the judgment result after the feeding process is underweight, the following is automatically performed
up to the maximum number of correction flow (Sq F-08) to compensate for the underweight value.
1. When the net value is judged to be underweight, the small flow output turns ON.
2. When the correction flow ON time (Sq F-16) has passed, the small flow output turns OFF.
3. When the correction flow OFF time (Sq F-17) has passed and the net value is stable (Sq F-07), the net
value is judged.
Timing chart
Overweight
Final weight
Underweight
Free fall Judge
Judge
Judge
T5 T10 T10
Small flow output
T9 T9
Weighing end output
OK/Over/Under output
Page 19 AD-4401A
8.2. Loss-in-weight Batching
●Weighing start
Operation: Function key (FncF-02), Control input
Setpoint values: Final weight, Free fall, Preliminary, Full, Overweight, Underweight, Near-zero
Feeding process
1. The weighing start input is detected.
2. When the weighing start input delay time (Sq F-09) has passed, the medium flow and small flow outputs
turn ON.
3. When the medium flow comparison disable time (Sq F-11) has passed and the – net value has become
below the preliminary value, the medium flow output turns OFF.
4. When the small flow comparison disable time (Sq F-12) has passed and the – net value has exceeded
the free fall value, the small flow output turns OFF.
5. When the judging delay time (Sq F-13) has passed and the net value is stable (Sq F-07), the net value
is judged.
AD-4401A Page 20
Timing chart
Preliminary Judge
Underweight
Free fall
Final weight
Overweight
Page 21 AD-4401A
●Correction flow
When the judgment result after the feeding process is underweight, the following is automatically performed
up to the maximum number of correction flow (Sq F-08) to compensate for the underweight value.
1. When the net value is judged to be underweight, the small flow output turns ON.
2. When the correction flow ON time (Sq F-16) has passed, the small flow output turns OFF.
3. When the correction flow OFF time (Sq F-17) has passed and the net value is stable (Sq F-07), the net
value is judged.
Timing chart
Judge
Free fall Judge
Judge
Underweight
Final weight
Overweight
T5 T10 T10
Small flow output
T9 T9
Weighing end output
OK/Over/Under output
AD-4401A Page 22
8.3. Sequential Weighing Functions
●Automatic free fall correction
Under the following conditions, the correct free fall value is automatically set.
- The weight value after the feeding process is within the final value ± automatic free fall correction
range (Sq F-04).
- The minimum small flow time for the automatic free fall correction (Sq F-05) has passed.
Select an automatic free fall correction method (Sq F-03) from the following.
- Moving average of last four weighings
- Fuzzy
●Automatic accumulation
When the weighing end output turns ON after the feeding process, the weight value is accumulated on the
total weight.
Select the condition to perform the automatic accumulation (SqF-02) from the following.
- Accumulates only when the judgment result is OK.
- Accumulates regardless of the judgment result.
●Automatic print
When the weighing end output turns ON after the feeding process, data is output from the standard serial
output (Si F-02) or options (bCdF-02, rS F-02).
●Emergency stop
The large flow, medium flow and small flow outputs turn OFF, the weighing sequence error output turns ON
and the indicator waits for the next weighing start input.
Operation: Function key (FncF-02), Control input
Page 23 AD-4401A
●Weighing sequence errors
When a sequence error is detected, the detected sequence number is displayed in the sub-display. (FncF-04)
AD-4401A Page 24
8.4. Simple Comparison Normal Batching
When the weight value is compared with the setpoint and the condition is met, the control output turns ON.
Timing chart
Overweight
Final weight
Free fall
Underweight
Preliminary
Optional
preliminary
Near-zero
Gross
Net
Under output
OK output
Over output
Near-zero output
Page 25 AD-4401A
8.5. Simple Comparison Loss-in-weight Batching
When the weight value is compared with the setpoint and the condition is met, the control output turns ON.
Timing chart
Preliminary
Underweight
Free fall
Final weight
Overweight
Under output
OK output
Over output
AD-4401A Page 26
9. CHECK WEIGHING FUNCTIONS
Check weighing separates the weight values into a maximum of five stages.
Select a weighing mode (CALF-14) from the following.
5: Check weighing 1
6: Check weighing 2
7: Check weighing 3
8: Check weighing 4
Timing chart
Hi-Hi limit
Target + Hi limit
Target
Target - Lo limit
Lo-Lo limit
Near-zero
Gross
Net
Hi-Hi output
Hi output
Go output
Lo output
Lo-Lo output
Near-zero output
Page 27 AD-4401A
9.2. Check Weighing 2
When the weight value is compared with the setpoint and the condition is met, the control output turns ON.
Timing chart
Hi-Hi output
Hi output
Go output
Lo output
Lo-Lo output
Near-zero output
AD-4401A Page 28
9.3. Check Weighing 3
When the weight value is compared with the setpoint and the condition is met, the control output turns ON.
Timing chart
Hi-Hi limit
Hi limit
Lo limit
Lo-Lo limit
Near zero
Gross
Net
Hi-Hi output
Hi output
Go output
Lo output
Lo-Lo output
Near-zero output
Page 29 AD-4401A
9.4. Check Weighing 4
When the weight value is compared with the setpoint and the condition is met, the control output turns ON.
Timing chart
Hi-Hi limit
Hi limit
Lo limit
Lo-Lo limit
Near-Zero
Gross
Net
Hi-Hi output
Hi output
Go output
Lo output
Lo-Lo output
Near-zero output
AD-4401A Page 30
10. CONTROL I/O
10.1. Pin Assignment
B1 B8
A1 A8
The applicable connector is an FCN-360 series 16-pin female connector manufactured by Fujitsu
Component Limited or the equivalent.
An FCN-361J016 (connector) and an FCN-360C016 (cover) are provided with the indicator.
Page 31 AD-4401A
10.2. Connection Diagram
Internal 12 V
Circuit 680 Ω
3.3 kΩ A1
A6
A7
Control input
- ON voltage: 5 V or less
- ON current: 3 mA or more
- OFF current: 1 mA or less
Internal
Circuit B1
B8
3.3 kΩ
A8
Control output
- Maximum load voltage: 30 VDC
- Maximum load current: 50 mA/point
- Voltage drop at ON: 1 V or less
- Leakage current at OFF: 0.1 mA or less
AD-4401A Page 32
10.3. Control Input Method
Two methods of control input are available; edge detection and level detection.
Edge detection
Control input is performed when the control input is turned ON (short-circuit) from the OFF state (open-
circuit).
The pulse width is 50 ms or more.
ON
OFF
Pulse width: 50 ms or more
Level detection
Control input is performed while the control input is ON (short-circuit).
ON
Release Hold Release
OFF
Page 33 AD-4401A
11. SETPOINT INPUT
Setpoints are set using the setpoint input from external devices.
Setpoints that cannot be set using the setpoint input are set using key switches.
B1 B12
A1 A12
The applicable connector is an FCN-360 series 24-pin female connector manufactured by Fujitsu
Component Limited or the equivalent.
The connector is not provided and must be prepared by the user.
The descriptions of the pin Nos. depend on the weighing mode (CALF-14) and the setpoint setting method
(SP F-01) settings.
In addition, when the minimum division (CALF-03) is 10 d or more, the setpoint will be ten times the setting
value.
Weighing mode = Normal batching, Loss-in-weight batching, Simple comparison normal batching, Simple
comparison loss-in-weight batching
Setpoint setting method = 5-digit input from external devices
Pin No. Description Description Pin No.
A1 BCD input 1 NC B1
A2 BCD input 2 NC B2
A3 BCD input 4 NC B3
A4 BCD input 8 NC B4
A5 Final weight 10^0 NC B5
A6 Final weight 10^1 NC B6
A7 Final weight 10^2 NC B7
A8 Final weight 10^3 NC B8
A9 Final weight 10^4 NC B9
A10 NC NC B10
A11 NC NC B11
A12 NC Shield B12
AD-4401A Page 34
Weighing mode = Normal batching, Loss-in-weight batching, Simple comparison normal batching, Simple
comparison loss-in-weight batching
Setpoint setting method = 16-digit input from external devices
Page 35 AD-4401A
Weighing mode = Check weighing 3
Setpoint setting method = 16-digit input from external devices
AD-4401A Page 36
11.2. Connection Diagram
Setpoint input is 4x16 key matrix input.
Internal 5V
680 Ω
circuit
1 kΩ A1
A2
A3
A4
A5
B8
Page 37 AD-4401A
12. STANDARD SERIAL OUTPUT
12.1. Pin Assignment
2
4 5
1 3
6 7
The applicable connector is a DIN connector 7-pin plug manufactured by Hosiden Corporation or the
equivalent.
A TCP0576-715267 connector is provided with the indicator.
AD-4401A Page 38
12.3. Output Data
Select an output data (Si F-01) from the following:
1: Displayed weight value (default)
2: Gross value
3: Net value
4: Tare value
5: Gross value + Net value + Tare value
6: Total weight
7: Number of accumulations
8: Total weight and number of accumulations
Page 39 AD-4401A
12.5. Output Data Format
●Gross value, net value, tare value
Item Value
ST, Stable
Header 1 US, Unstable
OL, Overload
GS, Gross value
Unit (CALF-01) kg kg
SP t t
No unit is added when the number of accumulations is output.
SP: space
AD-4401A Page 40
●Total weight, Number of accumulations
Item Value
Header 2 TW, Total weight
(Si F-01) TN, Number of accumulations
+0000012.34 Figure with a sign
Output weight value +0000000000 0
(Si F-01) + SP SP SP SP SP SP SP . SP SP Positive overload
- SP SP SP SP SP SP SP . SP SP Negative overload
SP SP None
SP g g
Unit (CALF-01) kg kg
SP t t
No unit is added when the number of accumulations is output.
SP: space
Page 41 AD-4401A
13. OPTION-01 BCD OUTPUT
13.1. Pin Assignment
B1 B20
A1 A20
The applicable connector is an FCN-360 series 40-pin female connector manufactured by Fujitsu
Component Limited or the equivalent.
An FCN-361J040 (connector) and an FCN-360C040 (cover) are provided with this option.
When the weight value is overloaded and the data output logic (bCdF-03) is set to negative logic (default), all
of the output data is turned ON.
AD-4401A Page 42
13.2. Connection Diagram
Internal
circuit
A1
A18
B1
B17
5V
680 Ω
1 kΩ B18
A19
B19
Hold input
- ON voltage: 1 V or less
- ON current: 3 mA or more
- OFF current: 1 mA or less
Page 43 AD-4401A
13.3. Data Output Timing
Select a data output timing (bCdF-02) from the following:
1: Interval output at the display update rate (FncF-03) (default)
2: In synchronization with automatic print
3: In synchronization with manual print
Timing chart
Valid data output width
Data output
Strobe output
Strobe output width
Hold input
50 ms 50 ms
The valid data output width is twice the strobe output width. Read the data within the valid data output width.
The strobe output width depends on the display update rate (FncF-03).
Display update rate Strobe output width
- 20 times/s 20 ms
- 10 times/s 45 ms
- 5 times/s 95 ms
Update will stop within 50 ms after the hold input turns ON. Then, update will restart within 50 ms after the
hold input turns OFF.
AD-4401A Page 44
14. OPTION-03 RS-422/485
14.1. Terminal Assignment
AD-4401A Master
1 Send data +
2 Send data -
3 Receive data +
4 Receive data -
Page 45 AD-4401A
14.2.2. 2-wire RS-485
Short-circuit the terminals No.1 and No.3, and the terminals No.2 and No.4 as shown below.
Terminal resistors must be installed on both ends of the circuit.
When a multidrop connection is required, refer to “Multidrop connection” in “14.9. Format When
Communication Type (rS F-02) is 4”.
100 Ω 5
AD-4401A Page 46
14.3. Communication Specifications
Page 47 AD-4401A
14.6. Format When Communication Type (rS F-02) is 1, 2, 3 or 7
●Data format (Gross value, Net value, Tare value)
Item Value
ST, Stable
Header 1 US, Unstable
OL, Overload
GS, Gross value
Unit (CALF-01) kg kg
SP t t
No unit is added when the number of accumulations is output.
SP: space
AD-4401A Page 48
●Data format (Total weight, Number of accumulations)
Item Value
Header 2 TW, Total weight
(Si F-01) TN, Number of accumulations
+0000012.34 Figure with a sign
Output weight value +0000000000 0
(Si F-01) + SP SP SP SP SP SP SP . SP SP Positive overload
- SP SP SP SP SP SP SP . SP SP Negative overload
SP SP None
SP g g
Unit (CALF-01) kg kg
SP t t
No unit is added when the number of accumulations is output.
SP: space
Page 49 AD-4401A
14.7. Format When Communication Type (rS F-02) is 5 or 6
●Data format (Comparison result + Weight value)
Item Value
Comparison result FF *1
Gross value (rS F-02=5)
Net value (rS F-02=6) 00007F *2
Output weight value (rS F-01)
*1: Comparison results are converted from 8 binary digits into 2 hexadecimal digits.
2 hexadecimal digits
0
1
16 16
8 binary digits 0: OFF 1: ON
3 2 1 0
2
7
2
6
2
5
2
4 2 2 2 2
Near-zero
Underweight/Hi-Hi
Overweight/Hi
Large flow/Go
Medium flow/Lo
Small flow/Lo-Lo
Discharge
Weighing end
*2: The gross value and the net value are converted from a signed decimal number into a 6-digit
hexadecimal number. Negative numbers are represented by the two's complement. A decimal point is
not included.
Decimal Hexadecimal
… …
+127 00007F
… …
2 000002
1 000001
0 000000
-1 FFFFFF
-2 FFFFFE
… …
-127 FFFF81
… …
AD-4401A Page 50
14.8. Format When Communication Type (rS F-02) is 8
●Data format (Weight value)
Item Value
+0001234 Figure with a sign
Output weight value +0000000 0
(rS F-01) + SP SP SP SP . SP SP Positive overload
- SP SP SP SP . SP SP Negative overload
Page 51 AD-4401A
14.9. Format When Communication Type (rS F-02) is 4
●Data format (Command)
Item Value
Command RW Read weight data
Read comparison result + gross value
RB
Read comparison result + net value
RF Read net value at weighing end
MZ Zero setting
MT Tare
CT Tare clear
DT Total clear
BB Weighing start
BD Discharge start
HB Emergency stop
AD-4401A Page 52
●Data format (Setpoint values)
Setpoint data format depends on the weighing mode (CALF-14).
Page 53 AD-4401A
●Multidrop connection
When a master and some AD-4401As are connected by a 1:n multidrop connection, a different slave
address (rS F-09) is assigned to each AD-4401A. When the master sends a command by adding the slave
address (@ 0 1 to @ 9 9) at the beginning, the AD-4401A with the matching slave address sends a
response by adding the slave address (@ 0 1 to @ 9 9) at the beginning.
Master @ 0 1 R W CR LF @ 0 1 R W CR LF
Slave Address
@ 0 1 Readoutdata
rS F-09 = 01
Slave Address
@ 0 2 Readoutdata
rS F-09 = 02
●Communication diagram
Three communication diagrams are shown below.
Reading data
R W : Read weight data
R B : Read comparison result + gross value, Read comparison result + net value
R F : Read net value at weighing end
R T : Read total weight + number of accumulations
R S : Read setpoint values
When the command above is sent, the corresponding data is sent in response.
Master
Command
AD-4401A
Readout data
AD-4401A Page 54
Function commands
M Z : Zero setting
M T : Tare
C T : Tare clear
D T : Total clear
M G : Display gross value in the main display
M N : Display net value in the main display
B B : Weighing start
B D : Discharge start
H B : Emergency stop
When the command above is sent, the command is echoed back and is executed.
Master
Command
AD-4401A
Command
Master
Command Written data
AD-4401A
Command Written data
Error response
I E : Response to the mode that does not accept commands
V E : Response to data whose format is correct but whose value is out of range
? E : Response to illegal commands/formats
Page 55 AD-4401A
14.10. Modbus-RTU When Communication Type (rS F-02) is 9
Modbus-RTU is available for the software version 1.03 or later.
When the communication type (rS F-02) is set to 9: Modbus-RTU, communication settings are as the
following.
Parity Even
Character bit length 8 bits
Stop bit length 1 bit
RS-422/485 electrical specifications 2-wire RS-485
For the 2-wire RS-485 connection method, refer to the connection diagram in "14.2.2. 2-wire RS-485".
AD-4401A Page 56
●Data address
R/ R/
Data address Item Data address Item
W W
000001 Near-zero 000201 Zero setting
000002 Underweight 000202 Tare
000003 Overweight 000203 Weighing start
000004 OK 000204 Emergency stop
000005 Large flow 000205 Discharge start
000006 Medium flow 000206 Manual free fall correction
000007 Small flow 000207 Tare clear
000008 Discharge 000208 Accumulation
000009 Weighing end 000209 Undoing accumulation
000010 Full 000210 Total clear
000011 Hi-Hi 000211 Print
000012 Hi 000212 Zero clear
W
000013 Go 000213 Display Gross
*1
000014 R Lo 000214 Display Net
000015 Lo-Lo 000215 Pause
000016 Stable 000216 Weighing restart
000017 Gross (0)/Net (1) display 000217 Forced weighing end
000018 In weighing sequence 000218 Forced discharge end
000019 Weighing sequence error 000219 Error clear
000020 Overload 000220 Manual correction flow
000021 When zero setting fails
000022 When tare fails
000023 Total weight overflow 000221-000300 Reserved internally
000024 Number of accumulations overflow
000025-000100 Reserved internally
R/
000101-000200 Reserved internally 000301-000400 Reserved internally
W
000401 Zero calibration
W
000402 Span calibration*2
*1
000403-000500 Reserved internally
*1: When "1" is written, the operation is executed.
*2: Before span calibration, set CALF-23 Calibration weights at span calibration via Modbus (400145-400146).
Page 57 AD-4401A
Data address (*1) R/W Item
400001-400002 Displayed weight value
400003-400004 Gross value
400005-400006 Net value
400007-400008 Tare value
400009-400010 Status display (*2)
400011-400012 Sub-display
400013-400014 Total weight
400015-400016 Number of accumulations
R
400017-400018 Gross value at weighing end
400019-400020 Net value at weighing end
400021-400022 Tare value at weighing end
400023-400024 Sequence number
400025-400026 Sequence error number
400027-400096 Reserved internally
400095-400096 Voltage ratio (nV/V) (*3)
400097-400098 Access interval timer (ms)
400099-400100 During an internal write cycle / Write result (*4)
400101-400146 Calibration functions (*5)
R/W
400147-400200 Reserved internally
400201-400202 Setpoint Final weight
400203-400204 Setpoint Free fall
400205-400206 Setpoint Preliminary
400207-400208 Setpoint Optional preliminary
400209-400210 Setpoint Overweight
400211-400212 Setpoint Underweight
400213-400214 Setpoint Full
R/W
400215-400216 Setpoint Near-zero
400217-400218 Setpoint Go
400219-400220 Setpoint Hi
400221-400222 Setpoint Lo
400223-400224 Setpoint Hi-Hi
400225-400226 Setpoint Lo-Lo
400227-400300 Reserved internally
400301-400400 Basic functions (*5)
400401-400500 Sequence functions (*5)
400501-400600 Control input functions (*5)
400601-400700 Control output functions (*5)
400701-400800 Standard serial output functions (*5)
R/W
400801-400900 BCD output functions (*5)
400901-401000 RS-422/485, RS-232C functions (*5)
401001-401100 Setpoint input functions (*5)
401101-401200 Analog 4-20 mA output functions (*5)
401201-401400 Reserved internally
*1: "Double Word" word order is low word first (L/H).
*2, *4: For the detailed description, refer to the next page.
*3: This function is available for the software version 1.08 or later
*5: Refer to "21. FUNCTION LIST".
AD-4401A Page 58
*2: Status display bit address
Data address Item
400009.15-07 Reserved internally
400009.06 Near-zero (Check weighing)
400009.05 Small flow (Normal / Loss-in-weight) Lo-Lo (Check weighing)
400009.04 Medium flow (Normal / Loss-in-weight) Lo (Check weighing)
400009.03 Large flow / Full (Normal / Loss-in-weight) Go (Check weighing)
400009.02 Overweight (Normal / Loss-in-weight) Hi (Check weighing)
400009.01 Underweight (Normal / Loss-in-weight) Hi-Hi (Check weighing)
400009.00 Near-zero (Normal / Loss-in-weight)
400010.15-07 Reserved internally
400010.06 ZERO
400010.05 STABLE (MD: Motion detection)
400010.04 GROSS
400010.03 NET
400010.02 HOLD
400010.01 Function □ (FncF-05)
400010.00 ALARM
Page 59 AD-4401A
15. OPTION-04 RS-232C
15.1. Pin Assignment
14 25
1 13
The applicable connector is a D-sub 25-pin male connector. The locking screw is M2.6.
The connector is not provided and must be prepared by the user.
AD-4401A Page 60
15.2. Connection Diagram
Connection to a PC serial port is as follows.
AD 4401A PC
8 DCD 1 DCD
3 TXD 2 RXD
2 RXD 3 TXD
20 DSR 4 DTR
7 GND 5 GND
6 DTR 6 DSR
4 CTS 7 RTS
5 RTS 8 CTS
22 DI 9 RI
Page 61 AD-4401A
16. OPTION-07 ANALOG 4-20 mA OUTPUT
16.1. Terminal Assignment
When the optional analog 4-20 mA output is not installed, the pins No.8 and No.9 are vacant.
Check the 07 column of the option list on the side of the indicator casing.
Shield
External load resistance
Analog current +
Analog current -
AD-4401A Page 62
16.3. Output Specifications
4 to 20 mA DC
Analog current output
External load resistance: 0 to 600
Maximum resolution 1/4000
Accuracy ±0.1%FS
Offset drift: ±3.2A/°C
Temperature coefficient
Gain drift: ±0.02%/°C
Conversion rate 10 ms
●Output adjustment
Output characteristic is represented by the straight line obtained by connecting between the weight value at
4 mA output (An F-02) and the weight value at 20 mA output (An F-03).
Output current
20 mA
4 mA
Weight value
0 3000
Page 63 AD-4401A
17. OPTION-23 Modbus-TCP
Modbus TCP is available for the software version 1.11 or later.
8 1
AD-4401A Page 64
17.3. IP Address, Subnet mask, Default gateway
Consult with the network administrator for the IP address, subnet mask, and default gateway setting.
0.0.0.0
01
to 192.168.0.2
02
255.255.255.255
03
04
Subnet mask 255. 255. XXX. 0
Available only to
05 255.255.0.0
255.255.255.0
06 or
07 255.255.255.0
08
Default XXX. XXX. XXX. XXX
gateway
0.0.0.0
09
to 0.0.0.0
10
255.255.255.255
11
12
Page 65 AD-4401A
18. SETPOINT SETTING
Set setpoint values for batch weighing and check weighing.
Refer to “14. OPTION-03 RS-422/485” for the setting procedure of the RS-232C or RS-422/485.
Refer to “11. SETPOINT INPUT” for the setting procedure using 5-digit or 16 digit input from external
devices.
AD-4401A Page 66
Normal mode
Select an item
Save Cancel
Page 67 AD-4401A
18.2. Setpoint Values List
Setpoints available for setting depend on the calibration function weighing mode (CALF-14).
When the minimum division (CALF-03) is 10 d or more, the setpoint will be ten times the setting value.
AD-4401A Page 68
19. OPERATION CHECKING
Operations are checked in the checking mode.
Select an operation to be checked and press the ENTER key.
Key switches
Page 69 AD-4401A
19.1. Checking Key Switches
When a key switch is pressed, “0” in the corresponding position turns to “1”.
A6 A5 A4 A3 A2 A1 B1 to B6
AD-4401A Page 70
19.4. Checking BCD Output
When the hold input turns ON, “0” turns to “1” and the output of the displayed pin No. turns ON.
Press the NET/GROSS key or Function key to switch pin Nos.
Page 71 AD-4401A
19.7. Checking Analog 4-20 mA Output
The current value (mA) in the sub-display is output.
Press the NET/GROSS key or Function key to increase or decrease the current value.
2 mA Output 20 mA Output
AD-4401A Page 72
19.10. Checking the Load Cell Connection with a Digital Multimeter
The load cell connection can be checked easily using a digital multimeter.
Page 73 AD-4401A
19.11. Check List
If the AD-4401A operates improperly, contact your local A&D dealer.
Use the chart below to write necessary items before contacting your dealer.
Checking item Example
Weighed product Plastic pellet, livestock feed
Capacity of the weighing instrument 20.00 kg
Minimum division of the weighing instrument 0.01 kg
Initial load on the weighing instrument 30 kg
Load cell connection method 6-wire ・ 4-wire 6-wire
Length of the extension load cell cable m Approx. 100 m
2 2
Cross section of the load cell cable mm 0.5 mm
Number of load cells connected 3 units
Summing box Used ・ Not used Used
Load cell model number and manufacturer LC4221-K050 A&D
Load cell rated capacity 50.99 kg
Load cell rated output mV/V 2.0394 mV/V
Load cell input resistance 400
Load cell output resistance 350
Load cell output at initial load *1 mV/V approx. 4.0 mV/V
at at 20.00 kg
Load cell output at capacity or any load. *1
mV/V approx. 6.8 mV/V
Control I/O Connected to Feed valve, lamp
Setpoint input Connected to
Standard serial output Connected to
OP-01 BCD output Connected to
OP-03 RS-422/485 Connected to PLC (Mitsubishi)
OP-04 RS-232C Connected to
OP-07 Analog 4-20mA output Connected to
*1 Refer to"19.8. Checking Load Cell Input".
1 EXC+ 2 SEN+ V
4 EXC- 3 SEN- V
6 SIG- 4 EXC- V
AD-4401A Page 74
20. INITIALIZATION
20.1. Parameter Initialization
While holding the SETPOINT key, turn the AD-4401
Power ON
ON.
Page 75 AD-4401A
20.3. All Data Initialization
AD-4401A Page 76
21. FUNCTION LIST
21.1. Calibration Function Setting
Set the calibration functions in the calibration function mode.
Page 77 AD-4401A
Operation in the calibration function mode:
Item selection
ENTER key Selects the displayed item and goes to the inputting mode of the item.
TARE key Shifts the blinking item to the right.
ZERO key Shifts the blinking item to the left.
NET/GROSS key Increases the blinking digit by one.
Function key Decreases the blinking digit by one.
ON/OFF key Returns to the “Cal Set” display.
Setting value input
ENTER key Saves the setting value and returns to the item selection mode.
TARE key Shifts the blinking digit to the right.
ZERO key Shifts the blinking digit to the left.
NET/GROSS key Increases the blinking digit by one.
Function key Decreases the blinking digit by one.
ON/OFF key Cancels the setting value and returns to the item selection mode.
Select an item
Save Cancel
AD-4401A Page 78
21.2. General Function Setting
Set the general functions in the general function mode.
Select a function to be set and press the ENTER key to go to the item selection mode.
BCD output
Page 79 AD-4401A
Operation:
Item selection
ENTER key Selects the displayed item and goes to the inputting mode of the item.
TARE key Shifts the blinking item to the right.
ZERO key Shifts the blinking item to the left.
NET/GROSS key Increases the blinking digit by one.
Function key Decreases the blinking digit by one.
ON/OFF key Returns to the general function mode.
Setting value input
ENTER key Saves the setting value and returns to the item selection mode.
TARE key Shifts the blinking digit to the right.
ZERO key Shifts the blinking digit to the left.
NET/GROSS key Increases the blinking digit by one.
Function key Decreases the blinking digit by one.
ON/OFF key Cancels the setting value and returns the item selection mode.
Select an item
Save Cancel
AD-4401A Page 80
21.3. Calibration Functions
User
CALF Modbus Item Setting Value Default
setting
0: None
1: g
400101 2
01 Unit 2: kg
400102 (4)
3: t
4: lb (For USA only)
0: 0 (No decimal point)
1: 0.0
400103
02 Decimal point position 2: 0.00 0
400104
3: 0.000
4: 0.0000
400105
03 Minimum division 1, 2, 5, 10, 20, 50 d 1
400106
400107
04 Maximum capacity 0 to 999999 20000
400108
400109
05 Zero setting range 0 to 100% 2
400110
400111 0.0: Not used
06 Zero tracking time 0.0
400112 0.1 to 5.0 s
0: Not used
1: 0.5 d
2: 1.0 d
3: 1.5 d
400113 4: 2.0 d
07 Zero tracking width 0
400114 5: 2.5 d
6: 3.0 d
7:3.5 d
8:4.0 d
9:4.5 d
400115 0.0: Not used
08 Stability detection time 1.0
400116 0.1 to 5.0 s
400117 0: Not used
09 Stability detection width 2
400118 1 to 9 d
400119 Tare and zero setting at 0: Disable
10 1
400120 unstable weight 1: Enable
400121 0: Disable
11 Tare at negative gross value 1
400122 1: Enable
Standard serial output, when the
400123 0: Disable
12 weight value is overloaded or 1
400124 1: Enable
unstable.
BCD, RS-422/485, RS-232C
400125 0: Disable
13 output, when the weight value is 1
400126 1: Enable
overloaded or unstable.
1: Simple comparison normal
batching
2: Simple comparison loss-
in-weight batching
400127 3: Normal batching
14 Weighing mode 3
400128 4: Loss-in-weight batching
5: Check weighing 1
6: Check weighing 2
7: Check weighing 3
8: Check weighing 4
400129 Load cell signal voltage at zero
15 0.000000 to 2.000000 0.000000
400130 calibration
Page 81 AD-4401A
User
CALF Modbus Item Setting Value Default
setting
(Load cell signal voltage at span
400131 calibrationCALF-15)
16 0.000000 to 3.200000 2.000000
400132 CALF-17/Calibration weight
value at span calibration
400133 Maximum capacity at span
17 0 to 999999 20000
400134 calibration
400135 Symbol used for header 2 of 1: GS/NT/TR 1
18
400136 standard serial output 2: G/N/T
400137 Symbol used for header 2 of 1: GS/NT/TR 1
19
400138 RS-232C or RS-422/485 2: G/N/T
Automatic zero setting upon
400139 0: Disable
20 power-on. Zero setting range is 0
400140 1: Enable
±10% of the maximum capacity.
400141 0: Disable
21 Zero clear 1
400142 1: Enable
Zero calibration, Span
400143 0: Disable
22 calibration and Calibration 1
400144 1: Enable
function setting via Modbus(*)
400145 Calibration weights at span
23 0 to 999999 20000
400146 calibration via Modbus.(*)
* Available for the software version 1.03 or later
AD-4401A Page 82
21.4. Basic Functions
User
FncF Modbus Item Setting Value Default
setting
00000000: All keys unlock
10000000: CAL key lock
01000000: SETPOINT key lock
Key lock in the normal 00100000: ZERO key lock
400301 0000
01 mode (excluding 00010000: TARE key lock
400302 0000
combination keys) 00001000: NET/GROSS key lock
00000100: Function key lock
00000010: ENTER key lock
00000001: ON/OFF key lock
0: None
1: Manual print
2: Hold
3: Weighing start
4: Emergency stop
5: Zero clear
6: Tare clear
7: Total clear
8: kg/lb unit selection (For USA only)
400303 9: Weighing restart
02 Function of Function key 0
400304 10: Discharge start
11: Forced weighing end
12: Forced discharge end
13: Error clear
14: Manual correction flow
15: Normal/Loss-in-weight batching
selection
16: Accumulation
17: Undoing accumulation
1: 20 times/s
400305
03 Display update rate 2: 10 times/s 1
400306
3: 5 times/s
0: None
1: Gross value
2: Net value
400307 3: Tare value
04 Function of sub-display 0
400308 4: Final weight
5: Total weight
6: Number of accumulations
7: Weighing sequence error
0: None
1: During discharge
400309 Condition to turn the 2: When zero tracking is enabled
05 0
400310 FUNCTION status ON 3: In weighing sequence
4: Normal batching (/loss-in-weight
batching)
Page 83 AD-4401A
User
FncF Modbus Item Setting Value Default
setting
1
10 digit:
Pre-digital filter cutoff 0: None
frequency 1: 11.0 Hz
2: 8.0 Hz
0
10 digit: 3: 5.6 Hz
Post-digital filter cutoff 4: 4.0 Hz
frequency 5: 2.8 Hz
6: 2.0 Hz
Pre-digital filter and 7: 1.4 Hz
post-digital filter are 8: 1.0 Hz
400311
06 connected in series. 9: 0.7 Hz 48
400312
101: 11.0 Hz (HPDF)
102: 8.0 Hz (HPDF)
103: 5.6 Hz (HPDF)
104: 4.0 Hz (HPDF)
HPDF cutoff frequency 105: 2.8 Hz (HPDF)
106: 2.0 Hz (HPDF)
107: 1.4 Hz (HPDF)
108: 1.0 Hz (HPDF)
109: 0.7 Hz (HPDF)
1: (FncF-06)/1
2: (FncF-06)/2
3: (FncF-06)/3
Sampling frequency 4: (FncF-06)/4
400313 divider ratio 5: (FncF-06)/5
07 1
400314 (Disabled when FncF-06 6: (FncF-06)/6
is 101 to 109) 7: (FncF-06)/7
8: (FncF-06)/8
9: (FncF-06)/9
10:((FncF-06)/10
400315 1: Normal hold
08 Hold function 1
400316 2: Peak hold
400317 0: Disable
09 Comparison at hold 0
400318 1: Enable
00000000: None
00000001: Overload
00000010: Total weight / number of
400319 Condition to turn the 0000
10 accumulations overflow
400320 ALARM status ON 0111
00000100: Zero setting error
00001000: Tare error
00010000: Weighing sequence error
AD-4401A Page 84
21.5. Weighing Sequence Functions
User
Sq F Modbus Item Setting Value Default
setting
400401 1: Internal value
01 Comparison target 1
400402 2: Displayed weight value
0: Disable
400403 Automatic accumulation
02 1: OK only 0
400404 condition
2: Regardless of the judgment result
0: Disable
400405 Automatic free fall
03 1: Moving average of last four weighings 0
400406 correction
2: Fuzzy
400407 Automatic free fall
04 0 to 9999999 0
400408 correction range
Minimum small flow time
400409
05 for the automatic free 0.0 to 30.0 s 3.0
400410
fall correction
400411 OK / Over / Under 1: Always
06 2
400412 output timing 2: In synchronization with weighing end
Wait for the weight value
400413 0: Disable
07 to be stable before the 1
400414 1: Enable
judgment
400415 Maximum number of 0: Disable correction flow
08 0
400416 correction flow 1 to 300
400417 Weighing start input
09 0.0 to 30.0 s 0.0
400418 delay time
400419 Large flow comparison
10 0.0 to 30.0 s 0.0
400420 disable time
400421 Medium flow
11 0.0 to 30.0 s 0.0
400422 comparison disable time
400423 Small flow comparison
12 0.0 to 30.0 s 0.0
400424 disable time
400425
13 Judging delay time 0.1 to 30.0 s 0.1
400426
400427 Weighing end output 0.0: Until the next weighing start
14 0.0
400428 time 0.1 to 30.0 s
400429 0: None
15 Flow timeout time 0
400430 1: 1 to 86400 s
400431
16 Correction flow ON time 0.01 to 3.00 s 0.10
400432
400433 Correction flow OFF
17 0.1 to 30.0 s 0.1
400434 time
400435 Discharge start input
18 0.0 to 30.0 s 0.0
400436 delay time
400437 Discharge end delay
19 0.1 to 30.0 s 0.1
400438 time
400439 0: None
20 Discharge timeout time 0
400440 1: 1 to 86400 s
Add the final weight to
400441 0: Disable
21 the near-zero setpoint 0
400442 1: Enable
value
400443 Add the final weight to 0: Disable
22 0
400444 the full setpoint value 1: Enable
400445
23 Reserved internally
400446
Simple comparison
400447 1: Positive logic
24 large/medium/small flow 1
400448 2: Negative logic
output logic
Page 85 AD-4401A
User
Sq F Modbus Item Setting Value Default
setting
Normal /loss-in-weight
400449 batching selection by 0: Disable
25 0
400450 the control input or 1: Enable
function key
1: Gross value
400451 Comparison target for 2: |Gross value|
26 1
400452 the near-zero value 3: Net value
4: |Net value|
Comparison target
400453 1: Gross value
27 excluding the near-zero 2
400454 2: Net value
and full values
400455 Automatic tare at 0: Disable
28 0
400456 weighing start 1: Enable
AD-4401A Page 86
21.6. Control Input Functions
User
in F Modbus Item Setting value Default
setting
400501 0: None
01 1
400502 1: Zero setting
400503 2: Tare
02 2
400504 3: Weighing start
400505 4: ON = Emergency stop
03 3
400506 / OFF = Release
400507 5: Discharge start
04 6: ON=Disable / OFF=Enable key 4
400508
400509 lock (FncF-01)
05 7: Manual free fall correction 5
400510
400511 8: ON=Disable / OFF=Enable reading
06 the setpoint input. 6
400512
9: Tare clear
10: Accumulation
11: Undoing accumulation
12: Total clear
13: ON=Hold / OFF=Release
Control input function
14: Print
15: Zero clear
16: Gross value display
17: Net value display
18: ON=Display gross value
OFF=Display net value
19: Weighing restart
20: Pause
21: Forced weighing end
22: Forced discharge end
23: Error clear
24: ON=Select loss-in-weight batching
OFF=Select normal batching
25: Manual correction flow
(One-shot small flow)
26: ON=Checking weighing start
OFF=Checking weighing stop
Page 87 AD-4401A
21.7. Control Output Functions
User
out F Modbus Item Setting value Default
setting
400601 Condition to turn each 0: None
01 1
400602 control output ON 1: Near-zero
400603 2: Underweight, Hi-Hi
02 2
400604 3: Overweight, Hi
400605 4: Large flow, Full, Go
03 3
400606 5: Medium flow, Lo
400607 6: Small flow, Lo-Lo
04 7: Discharge 4
400608
400609 8: Weighing end
05 9: Stable 5
400610
400611 10: In the normal mode
06 11: In weighing sequence 6
400612
400613 12: Weighing sequence error
07 13: 0.5 s after detecting a rise edge of 7
400614
400615 the control input
08 14: When zero setting fails 8
400616
15: Overload
16: Reserved internally
17: When tare fails
18: When zero setting or tare fails
19: Total weight / number of
accumulations overflow
20: When the judgment result is OK
21: Hold
22: ON = loss-in-weight batching
/ Off = Normal batching
AD-4401A Page 88
21.8. Standard Serial Output Functions
User
Si F Modbus Item Setting Value Default
setting
1: Displayed weight value
2: Gross value
3: Net value
4: Tare value
400701
01 Output weight value 5: Gross value + Net value + Tare value 1
400702
6: Total weight
7: Number of accumulations
8: Total weight and number of
accumulations
1: Interval output at the display update
rate (FncF-03)
400703 2: In synchronization with automatic print
02 Data output timing 1
400704 3: In synchronization with manual print
4: In synchronization with automatic /
manual accumulation
400705 1: 600 bps
03 Baud rate 2
400706 2: 2400 bps
400707 Standard serial output 0: None
04 0
400708 slave address 1 to 99
Page 89 AD-4401A
21.10. RS-422/485, RS-232C Functions
User
rS F Modbus Item Setting Value Default
setting
1: Displayed weight value
2: Gross value
3: Net value
4: Tare value
400901
01 Output weight value 5: Gross value + Net value + Tare value 1
400902
6: Total weight
7: Number of accumulations
8: Total weight and number of
accumulations
1: Interval output at the display update
rate (FncF-03)
2: In synchronization with automatic print
3: In synchronization with manual print
4: Response to command
5: Interval output of comparison result
400903
02 Communication type and gross value at 100 times/s 1
400904
6: Interval output of comparison result
and net value at 100 times/s.
7: In synchronization with
automatic/manual accumulation
8: Interval output at 100 times/s
9: Modbus-RTU
1: 600 bps
2: 1200 bps
3: 2400 bps
400905 4: 4800 bps
03 Baud rate 5
400906 5: 9600 bps
6: 19200 bps
7: 38400 bps
8: 115200 bps
0: None
400907
04 Parity 1: Odd 2
400908
2: Even
400909 7: 7 bits
05 Character bit length 7
400910 8: 8 bits
400911 1: 1 bit
06 Stop bit length 1
400912 2: 2 bits
400913 1:CR
07 Terminator 2
400914 2:CR LF
1: RS-422 (rS F-09=0)
400915 RS-422/485
08 1: 4-wire RS-485 (rS F-09 0) 1
400916 electrical specifications
2: 2-wire RS-485
400917 RS-422/485 0: None
09 0
400918 slave address 1 to 99
400919 Command Response 0.00 to 3.00 s
10 0.06
400920 delay time
AD-4401A Page 90
21.11. Setpoint Input Functions
User
SP F Modbus Item Setting Value Default
setting
0: Setpoint input not used
401001
01 Setpoint setting method 1: 5-digit input from external devices 0
401002
2: 16-digit input from external devices
0.0.0.0
01 -
to 192.168.0.2
02 -
255.255.255.255
03 -
04 -
Subnet 255. 255. XXX. 0
mask Available only to
05 - 255.255.0.0
255.255.255.0
06 - or
07 - 255.255.255.0
08 -
Default XXX. XXX. XXX. XXX
gateway
0.0.0.0
09 -
to 0.0.0.0
10 -
255.255.255.255
11 -
12 -
Page 91 AD-4401A
22. SPECIFICATIONS
Dimensions 144 (W) x 72 (H) x 197 (D) mm
Operating temperature and -10 °C to 40 °C
humidity range Less than 85%RH, non-condensing
When the indicator is secured to the control panel:
IP rating Outside of the control panel: IP65
Inside of the control panel: IP2X
Power supply
Power supply voltage 100 VAC to 240 VAC +10% -15%, 50/60 Hz ±5%
Maximum apparent power 30 VA
Rush current 100 VAC: 15 A or less, 200 VAC: 30 A or less
Fuse Internal (Not user replaceable)
Load cell input
10 VDC±5% 230 mA
Excitation voltage Up to eight 350 load cells can be connected in parallel.
6-wire type with remote sensing
Signal input range 0.0 to 3.2 mV/V
Minimum input sensitivity 0.3 V
Zero calibration range 0.0 to 2.0 mV/V
Nonlinearity ±0.01%
Temperature coefficient Zero drift: ±0.2 V/°C RTI Typ., Span drift: ±8ppm/°C Typ.
Sampling rate 100 times/s
Display
Main display 7-digit VFD with character height of 13 mm
Sub-display 8-digit VFD with character height of 7 mm
Unit g, kg, t, lb (For USA only) or none (selectable)
Status display 14
Key switches
Key switch 7
Key switch with sealing cover 1
External Input / output
Non-voltage contact input: 6 points
Control I/O
NPN open collector: 8 points
Setpoint input Key matrix input
Standard serial output Current loop output
Option boards
BCD output
RS-422/485
RS-232C A slot is available only for analog 4-20 mA output.
Among other option boards, only one can be installed.
Modbus TCP
Analog 4-20 mA output
AD-4401A Page 92
External dimensions
パネルカット寸法
Panel
Panel cutout dimensions
cutout dimensions
Panel
Panel 1.6~3.2
板厚 thickness:
thickness:1.6
1.6to
to3.2
3.2
Unit: mm
Page 93 AD-4401A
MEMO
AD-4401A Page 94
MEMO
Page 95 AD-4401A
MEMO
AD-4401A Page 96
13
3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013, JAPAN
Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148