0% found this document useful (0 votes)
236 views

JT Plants: PC Liquids

Exterran's skid-mounted JT plants provide hydrocarbon dewpoint control and increased natural gas liquid recovery from gas streams between 2 to 40 MMscfd. The preassembled packages are easily installed and reduce water and hydrocarbon dewpoints to meet pipeline specifications. The JT plant uses a gas-to-gas exchanger, optional liquid-to-gas exchanger, JT valve, cold separator, and control system mounted on a single skid. After separation and cooling, gas passes through the exchangers and JT valve where expansion causes significant temperature reduction and hydrocarbon condensation in the cold separator. Recovered natural gas liquids are stored in a separate pressurized tank.

Uploaded by

Jimenez Argenis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
236 views

JT Plants: PC Liquids

Exterran's skid-mounted JT plants provide hydrocarbon dewpoint control and increased natural gas liquid recovery from gas streams between 2 to 40 MMscfd. The preassembled packages are easily installed and reduce water and hydrocarbon dewpoints to meet pipeline specifications. The JT plant uses a gas-to-gas exchanger, optional liquid-to-gas exchanger, JT valve, cold separator, and control system mounted on a single skid. After separation and cooling, gas passes through the exchangers and JT valve where expansion causes significant temperature reduction and hydrocarbon condensation in the cold separator. Recovered natural gas liquids are stored in a separate pressurized tank.

Uploaded by

Jimenez Argenis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

JT Plants

Exterran’s skid-mounted JT plants are easy to


use, integrated packages designed to provide
hydrocarbon dewpoint control and increased
recovery of valuable natural gas liquids (NGL).
These preassembled packages are available in
standard designs for gas streams from 2 to 40
MMscfd. Ideally suited for quick installation
in short-term operating environments, JT
plants reduce the water and hydrocarbon
dewpoint to pipeline specifications and
reduce the BTU content of fuel gas to levels suitable
for high-speed engines.
The JT plant consists of a gas-to-gas exchanger with hot gas bypass, optional liquid-to-gas exchanger, JT
valve, cold separator, methanol injection system and control system, all mounted on a single skid. The
use of standard designs and components sized to match your production allows quick construction and
fast delivery, helping you get your wells online sooner. Exterran engineers size and select JT plants to your
specifications, ensuring the equipment has maximum run time.
The complete JT plants and the individual components have high salvage value and can be easily adapted
for other treating applications. Exterran gas-to-gas exchangers and cold separators are built and stamped
in accordance with ASME code
How it works:
After gas/liquid separation and ambient cooling, high-pressure (1,000 to 1,300 psig) untreated gas enters
the plant through the gas-to-gas exchanger and chiller for pre-cooling. Methanol is injected to prevent
formation of hydrates, and the raw natural gas passes through a JT valve. The resulting pressure drop
causes expansion of the gas and a significant reduction in temperature due to the Joule-Thomson effect.
The cooled gas is routed to the Cold Separator for separation of the condensed NGL. The outlet gas from the
cold separator is routed through the gas-to-gas exchanger for inlet cooling. The NGL from the cold separator
is routed through the inlet chiller and then to a separate pressurized NGL storage tank, where it is flashed to
remove any methane vapor absorbed by the NGL.

LIQUIDS PC

COLD
INLET SEPARATOR

GAS/GAS JT
LIQ/GAS
EXCHANGER EXCH VALVE LC

TREATED
GAS
Other Information for JT Plants
Standard JT Equipment
Standard Features
Nominal Estimated Gas- Cold NGL
Skid
• ASME gas-to-gas code Gas Rate, to-Gas Exchanger Separator Capacity,
Dimensions
exchangers MMscfd Area, sq ft Size, OD B/D
2 170 16” X 7’6” 734 6’ x 24’
• Temperature controller
5 457 24” x 10’ 2232 6’ x 24’
• Instrument gas/air 10 914 24” x 10’ 2232 8’ x 38’
manifold 15 1371 42” x 15’ 4896 8’6” x 36’
• Sight glass safety valves 20 967 24”x 10’ 2232 10’ x 38’
The listed information shows approximate capacities. The NGL Capacities are based on 1 minute retention time.
• ASME code cold Please contact Exterran Engineering with the required infomration for specific applications.
separator
• Methanol pump
• Cold thermal insulation
• Hot gas bypass system
• Methanol delivery system
• NGL to gas exchanger
Optional Designs
• Hairpin exchangers
• Control isolation valves
• Ethylene glycol injection
system
• NGL Bullet Tank
• 3 Phase Separator
• Larger Units Installed Custom Designed 120 MMscfd JT Plant

Submit info to your Exterran Rep or [email protected] for sizing.


Gas Flow Rate, MMSCFD: @ PSIG @ ºF SP.GR.
Oil Flow Rate, BPD: SP.GR. APIº
Water Flow Rate, BPD: SP.GR. MAWP
Sour Gas: Yes No
Corporate Offices CO2: Mole%
H2S: PPM
16666 Northchase Drive
Paint Standard: Yes No
Houston, TX 77060
281.836.7000
www.exterran.com Proper sizing requires full gas analysis and pipeline specifications

ExCat-JT-06.23.10