JT Plants: PC Liquids
JT Plants: PC Liquids
LIQUIDS PC
COLD
INLET SEPARATOR
GAS/GAS JT
LIQ/GAS
EXCHANGER EXCH VALVE LC
TREATED
GAS
Other Information for JT Plants
Standard JT Equipment
Standard Features
Nominal Estimated Gas- Cold NGL
Skid
• ASME gas-to-gas code Gas Rate, to-Gas Exchanger Separator Capacity,
Dimensions
exchangers MMscfd Area, sq ft Size, OD B/D
2 170 16” X 7’6” 734 6’ x 24’
• Temperature controller
5 457 24” x 10’ 2232 6’ x 24’
• Instrument gas/air 10 914 24” x 10’ 2232 8’ x 38’
manifold 15 1371 42” x 15’ 4896 8’6” x 36’
• Sight glass safety valves 20 967 24”x 10’ 2232 10’ x 38’
The listed information shows approximate capacities. The NGL Capacities are based on 1 minute retention time.
• ASME code cold Please contact Exterran Engineering with the required infomration for specific applications.
separator
• Methanol pump
• Cold thermal insulation
• Hot gas bypass system
• Methanol delivery system
• NGL to gas exchanger
Optional Designs
• Hairpin exchangers
• Control isolation valves
• Ethylene glycol injection
system
• NGL Bullet Tank
• 3 Phase Separator
• Larger Units Installed Custom Designed 120 MMscfd JT Plant
ExCat-JT-06.23.10