Infiniium Oscilloscope Probes and Accessories: Keysight Technologies
Infiniium Oscilloscope Probes and Accessories: Keysight Technologies
Data Sheet
To get the most out of your Infiniium oscilloscope, you need the right probes and accessories for your
particular applications. Whether you need the high bandwidth and low loading of an active probe, an
easy way to connect to surface mount ICs, or a passive probe to measure high voltages, there’s a wide
selection of high-quality probes and accessories for your Infiniium oscilloscope.
Table of Contents
Probe Compatibility Table............................................................................... 3
InfiniiMax Active Probe System Overview....................................................... 4
InfiniiMax III/III+ probing system................................................................ 6
InfiniiMax II probing system..................................................................... 14
InfiniiMax I probing system...................................................................... 21
Active Termination Adapter........................................................................... 25
InfiniiMode Active Probes ............................................................................. 27
N2750A/51A/52A InfiniiMode probes .....................................................27
Single-Ended Active Probes ......................................................................... 30
N2795A/96A/97A active probes.............................................................. 30
N7020A power rail probe......................................................................... 32
General Purpose Differential Active Probes ................................................. 34
N2790A/91A/891A high-voltage differential probes.............................. 34
N2804/05A high voltage differential probes........................................... 35
1153A/41A low-noise differential probes................................................ 36
N2818A/19A general-purpose differential probes.................................. 37
AC/DC Current Probes.................................................................................. 38
1146B low-cost AC/DC current probe..................................................... 38
1147B/N2893A AC/DC current probe .................................................... 39
N2780B/81B/82B/83B/83L AC/DC current probes............................... 40
High-Sensitivity Current Probes.................................................................. 41
General Purpose Passive Probes................................................................... 43
N2870A-76A passive probes.................................................................... 43
1165A passive probe................................................................................ 46
54006A high bandwidth passive probe................................................... 48
High Voltage Passive Probes......................................................................... 49
10076C 100:1 passive probe.................................................................... 49
N2771B 1000:1 passive probe................................................................. 50
Mixed Signal Oscilloscope Logic Probes and Accessories........................... 51
Probing Accessories...................................................................................... 53
InfiniiMax probe accessories.................................................................... 53
N2744A T2A probe interface adapter...................................................... 54
N2784A/85A/86A/87A probe positioners............................................... 54
Wedge probe adapters............................................................................. 56
Fine pitch and PC board accessories....................................................... 57
E2697A high impedance adapter............................................................ 57
Related Literature.......................................................................................... 58
03 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Or refer to our probe overview page at the beginning of each section in the table of contents
explaining what the different probe types are and the models available for your Infiniium.
General purpose passive N2870A-76A, 10073D, N2870A-76A, 10073D, N2870A-76A, 10073D, N2873A with N5449A
probes, page 40 10070D, 1165A 10070D, 1165A 10070D, 1165A with E2697A (N5449A includes one
N2873A)
High voltage passive 10076C, N2771B 10076C, N2771B 10076C, N2771B with 10076C, N2771B with
probes, page 46 E2697A N5449A
* The 1147B, N2790A and N2893A are not compatible with 80000, 90000 and 90008 Series scopes.
04 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The InfiniiMax probing system offers you the highest performance available for measuring
differential and single-ended signals, with flexible connectivity solutions for today’s
high-density ICs and circuit boards. Keysight Technologies, Inc. pioneered “probe head”
type probes starting with the InfiniiMax I probe system in 2003. InfiniiMax I boasted a
7 GHz bandwidth and provided both differential and single-ended probe heads to fit
multiple use models. The “probe head” topology allows higher performance. It allows
more flexibility in the use models accommodating browser, solder-in, SMA etc.
In 2005 Keysight released InfiniiMax II 1168A/69A Series. This continued the probe head
style probe topology while boosting the bandwidth to 13 GHz. The technology used for
InfiniiMax II is the same as the one for InfiniiMax I except for the use of a new 70 GHz
SiGe bipolar IC process. InfiniiMax II set new standards for performance, low noise, and
low loading.
Modern high speed digital applications have pushed the limit of high bandwidth and high
performance probing solutions. Keysight offers four different InfiniiMax probe families to
meet today’s challenging high speed measurement needs -- InfiniiMax I/II/III/III+.
Each of these solutions has its own, unique value. The principle difference is found in the
key performances, functions and tasks that optimize each for its intended applications.
Note that InfiniiMax I and II probe probe heads are compatible to each other, but they are
not compatible with InfiniiMax III/III+ and vice versa.
Key features
–– Full 30 GHz bandwidth to the probe tip
–– InfiniiMode probing for making differential, single-ended and common mode
measurements with a single probe (InfiniiMax III+)
–– Industry’s highest fidelity and accuracy due to bandwidth and extremely low loading
–– Probe amplifiers loaded with measured S-parameters for more accurate response
correction
–– Bandwidth upgradeable (InfiniiMax III only)
–– Variety of probe heads for different use models with maximum usability
Scope compatibility
Scope family Compatible probes
V-Series, 90000X/Q, Z-Series N2800A, N2801A, N2802A, N2803A, N7000A,
N7001A, N7002A, N7003A
S-Series, 90000A Series N2830A, N2831A, N2832A
The InfiniiMax III/III+ probing system provides the highest performance and low loading
to allow for a completely new level of signal fidelity and accuracy. Eleven different In-
finiiMax III/III+ probe amplifiers ranging from 4 GHz to 30 GHz are available for matching
your probing solution to your performance and budget requirements. The InfiniiMax
III+ probing system is the next generation of InfiniiMax probing. It greatly expands the
measurement capability and usability of probes capable of measuring all components of
a differential signal with the built-in InfiniiMode technology.
InfiniiMax Active Probe System Overview – InfiniiMax III/III+ Probing System (continued)
InfiniiMax Active Probe System Overview – InfiniiMax III/III+ Probing System (continued)
ZIF probe head/tips N5439A head, 28 GHz, Cdiff = 95 fF, Cse = 130 fF, with Extremely low loading, Variable spacing from 5 mil to
N2838A 450 Ω PCB N2838A: Cdiff = 32 fF, Cse = 44 fF, with 80mil , User replaceable damping resistor tips
tip, N5440A 450 Ω N5440A: Rdiff = 100 kΩ, Rse = 50 kΩ (N2838A only)
ceramic tip, N5447A N5447A: Rdiff = 50 kΩ, Rse = 25 kΩ with
200 Ω ceramic tip N5440A/N2838A
2.92 mm/3.5 mm/ N5444A 28 GHz, N/A, 55 Ω to Vterm Provides termination voltage of ± 4 V controlled by
SMA probe head scope or externally. Supports InfiniiMode with
InfiniiMax III+ amp
Solder-in head N5441A 16 GHz, Cdiff = 77 fF, Cse = 105 fF, Economical and semi-permanent connection, variable
Rdiff=100 kΩ, Rse = 50 kΩ span of leads ranges from 5 mil to 80 mil, user replace-
N2836A 26 GHz, Cdiff = 108 fF, Cse = 140 fF, able damping resistor tips (N2836A only). N2836A
Rdiff=100 kΩ, Rse=50 kΩ supports InfiniiMode with InfiniiMax III+ amp
Quick tip N2848 QuickTip 16 GHz (with InfiniiMax III/III+), Compatible with I/II/III/III+ amp. Supports InfiniiMode
head for 13 GHz (with InfiniiMax II), with InfiniiMax III+ amp . For using QuickTip with
InfiniiMax III/III+, Cdiff = 340 fF, Cse = 200 fF InfiniiMax I/II amp, choose the N2851A QuickTip head
N2849A QuickTip tips for InfiniiMax I/II and N2849A QuickTip tips.
09 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
InfiniiMax Active Probe System Overview – InfiniiMax III/III+ Probing System (continued)
InfiniiMax Active Probe System Overview – InfiniiMax III/III+ Probing System (continued)
InfiniiMax Active Probe System Overview – InfiniiMax III/III+ Probing System (continued)
N280XA InfiniiMax III probe amp N700xA InfiniiMax III+ probe amp
Features 450 Ω probe heads 200 Ω probe heads N5444A 2.92 mm, SMA, 450 Ω probe heads N5444A 2.92 mm, SMA,
3.5 mm probe head 3.5 mm probe head
DC input resistance Rse=50 kΩ ± 2% each Rse=50 kΩ ± 2% 55 Ω to Vterm Rse=50 kΩ ± 2% 55 Ω to Vterm
input to ground, each input to ground, each input to ground,
Rdiff=100 kΩ ± 2% and Rdiff=100 kΩ ± 2% and Rdiff=100 kΩ ± 2% and
Rcm=25 kΩ ± 2% Rcm=25 kΩ ± 2% Rcm=25 kΩ ± 2%
Input resistance Rse=500 Ω each input Rse=500 Ω each input 50 Ω to .901*Vterm Rse=500 Ω each input 50 Ω to .901*Vterm
>10 kHz to ground, Rdiff=1 kΩ to ground, Rdiff=1 kΩ to ground, Rdiff=1 kΩ
and Rcm=250 Ω and Rcm=250 Ω and Rcm=250 Ω
Input voltage range 1.6 Vpp, ± 0.8 V 0.8 Vpp, ± 0.4 V 1.6 Vpp, ±0.8 V 2.5 Vpp or ± 1.25 V at 2.5 Vpp or ± 1.25 V at
(differential or (HD2&3 < –34 dbc), (HD2&3 < –34 dbc), (HD2&3 < –34 dbc), 5:1 attenuation, 5:1 attenuation,
single-ended) 2.5 Vpp, ± 1.25 V 1.6 Vpp, ± 0.8 V 2.5 Vpp, ± 1.25 V 5.0 Vpp or ± 2.50 V at 5.0 Vpp or ± 2.50 V at
(HD2&3 < –38 dbc) (HD2&3 < –38 dbc) (HD2&3 < –38 dbc) 10:1 attenuation 10:1 attenuation
without violating max
input power
Max input power n/a n/a 125 mW n/a 125 mW calculated by
calculated by {[rms(vin-vterm)]^2/55]}
{[rms(vin-vterm)]^2/55]} for each input
for each input
Input common mode ± 12 VDC to 250 Hz, ± 6 VDC to 250 Hz, ± 6 VDC to 250 Hz, ± 7 VDC to 100 Hz, ± 6 VDC to 100 Hz,
range ± 1.25 V > 250 Hz ± 0.65 V > 250 Hz ± 1.25 V > 250 Hz ± 1.25 V > 100 Hz at ± 1.25 V > 100 Hz at
without violating max 5:1 attenuation, 5:1 attenuation,
input power ± 2.5 V > 100 Hz at ± 2.5 V > 100 Hz at
10:1 attenuation 10:1 attenuation
without violating max
input power
DC attenuation ratio 6:1 3:1 6:1 5:1 or 10:1 5:1 or 10:1
Automatically selected Automatically selected
based on volts/division based on volts/division
(all modes) (all modes)
Offset range ± 16 V ±8V ± 6 V without ± 16 V ± 6 V without violating
(for probing a violating max input max input power
single-ended signal) power
Input referred noise 23.9 nV/rt (Hz) 12.0 nV/rt (Hz) 23.9 nV/rt (Hz) Diff 5:1 atten 33.5 nV/rt(Hz), Diff 10:1 atten
spectral density 53.9 nV/rt(Hz), SE A or B 5:1 atten 27.8 nV/rt(Hz),
SE A or B 10:1 atten 47.7 nV/rt(Hz), CM 5:1 atten
21.8 nV/rt(Hz), CM 10:1 atten 38.4 nV/rt(Hz)
Input referred noise 4 mVrms with 2 mVrms with 4 mVrms 4.5 mVrms in diff mode 4.5 mVrms in diff mode
example 28 GHz probe head and 28 GHz probe head and 5:1 atten with >= 5:1 atten with 28 GHz
30 GHZ probe amp 30 GHz probe amp 18 GHz probe head and N5444A probe head and
13 GHz probe amp 13 GHz probe amp
Maximum input 18 Vpeak Cat 1 18 Vpeak Cat 1 8 Vpeak without violating 18 Vpeak Cat 1 8 Vpeak without violating
voltage max input power max input power
12 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
InfiniiMax Active Probe System Overview – InfiniiMax III/III+ Probing System (continued)
Ordering information
InfiniiMax III/III+ probe amplifier models
Model number Description Recommended oscilloscope
N2803A 30 GHz InfiniiMax III probe amplifier Infiniium 90000X/Q, Z-Series 28 GHz - 63 GHz models
N2802A 25 GHz InfiniiMax III probe amplifier Infiniium 90000X/Q, Z-Series 25 GHz models
N7003A 20 GHz InfiniiMax III+ probe amplifier Infiniium V-Series, 90000Q, Z-Series 20 GHz models
N2801A 20 GHz InfiniiMax III probe amplifier Infiniium 90000X/Q, Z-Series 20 GHz models
N7002A 16 GHz InfiniiMax III+ probe amplifier Infiniium V-Series, 90000X Series 16 GHz models
N2800A 16 GHz InfiniiMax III probe amplifier Infiniium 90000X Series 16 GHz models
N7001A 13 GHz InfiniiMax III+ probe amplifier Infiniium V-Series, 90000X Series 13 GHz models
N2832A 13 GHz InfiniiMax III+ probe amplifier Infiniium 90000X 13 GHz and 90000A models
N7000A 8 GHz InfiniiMax III+ probe amplifier Infiniium V-Series 8 GHz models
N2831A 8 GHz InfiniiMax III+ probe amplifier Infiniium 90000A and S-Series
N2830A 4 GHz InfiniiMax III+ probe amplifier Infiniium 90000A and S-Series
Note: InfiniiMax III and III+ probe amps are not compatible with existing InfiniiMax I or II probe heads.
InfiniiMax Active Probe System Overview – InfiniiMax III/III+ Probing System (continued)
Scope compatibility
Scope family Recommended probes
DSO90000, DSA90000, DSO80000, DSA80000 Series 1168A, 1169A
The InfiniiMax II series 1168A/69A probing system designed to be used with Infiniium
80000A and 90000A Series oscilloscopes provides real-time bandwidth to 12 GHz specified
and has 13 GHz typical performance. The innovative InfiniiMax probing system supports
even the most demanding mechanical access requirements without sacrificing performance.
Graph of Vin and Vout of 1169A and N5381A solder-in head with a 25 Ω 58 psec step generator
Ordering information
InfiniiMax II Series probe amplifiers
Model number Bandwidth Description
1169A 12 GHz (spec) 13 GHz (typical) InfiniiMax II probe amplifier – order one or more probe heads
1168A 10 GHz InfiniiMax II probe amplifier – order one or more probe heads
InfiniiMax probe amplifier specifications: Dynamic range = 3.3 V, DC offset range = ± 16 V, maximum voltage = ± 30 V
InfiniiMax I Series probe heads can be used with 1169A/68A probe amplifiers with limitations.
To learn more about how to use the InfiniiMax probe with your test equipment other than
Keysight Infiniium oscilloscopes, refer to the Keysight literature number 5989-1869EN.
N5451A
18 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Performance characteristics
1169A 1168A
Bandwidth* 1169A: > 12 GHz (13 GHz typical) 1168A: > 10 GHz
Rise and fall time
Probe only 1169A: 28 ps (20 - 80%), 40 ps (10 - 90%) 1168A: 34 ps (20 - 80%), 48 ps (10 - 90%)
When phase compensated by 1169A w/91204A: 25 ps (20 - 80%) 1168A w/90804A: 38 ps (20 - 80%)
90000A Series oscilloscope 36 ps (10 - 90%) 54 ps (10 - 90%)
1169A w/91304A: 23 ps (20 - 80%)
33 ps (10 - 90%)
System bandwidth (–3 dB) 1169A w/91304A: 13 GHz (typical) 1168A w/90804A: 8 GHz
1169A w/91204A: 12 GHz
Input capacitance1 Cm = 0.09 pF Cm is between tips
Cg = 0.26 pF Cg is to ground for each tip
Cdiff = 0.21 pF Differential mode capacitance = Cm + Cg/2
Cse = 0.35 pF Single-ended mode capacitance = Cm + Cg
Input resistance* Differential mode resistance = 50 kΩ ± 2%
Single-ended mode resistance = 25 kΩ ± 2%
Input dynamic range 3.3 V peak to peak, ± 1.65 V
Input common mode range ± 6.75 V dc to 100 Hz; ± 1.25 V > ± 100 Hz
Maximum signal slew rate 25 V/ns when probing a single-ended signal
40 V/ns when probing a differential signal
DC attenuation 3.45:1
Zero offset error referred to input ± 1.5 mV
Offset range ± 16.0 V when probing single-ended
Offset gain accuracy < ± 1% of setting when probing single-ended
Noise referred to input 2.5 mV rms, probe only
Propagation delay ~6 ns (this delay can be deskewed relative to other signals)
Maximum input voltage 30 V peak, CAT I
ESD tolerance > 8 kV from 100 pF, 300 Ω HBM
Temperature Operating: 5 °C to +40 °C
Non-operating: 0 °C to +70 °C
21 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Key features
–– Up to 7 GHz bandwidth for differential, solder-in, browser and SMA connections
–– Low noise and flat frequency response
–– Wide dynamic range (± 2.5 V) and offset range (± 12 V)
Scope compatibility
Scope family Recommended probes
DSO/DSA90604A 1134A
DSO/DSA90404A,DSO/MSO9404A 1132A
DSO/DSA90254A, DSO/MSO9254A, 54845/46/53A/B 1131A
DSO/MSO9104A, 9064A, 8104A, 5483xB/D 1130A
Vin and Vout of probe with a 25 Ω, 100 psec step signal Swept frequency response with a 25 Ω source
0
-10
-20
dB
-30
-40
-50
-60
108 109 1010
Frequency (Hz)
Probe input impedance vs. frequency Common mode rejection versus frequency
22 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The Keysight InfiniiMax 1134A, 1132A, 1131A and 1130A probe systems provide 7 GHz,
5 GHz, 3.5 GHz and 1.5 GHz of bandwidth respectively, and offer the following benefits:
–– The probes have a flat frequency response over the entire bandwidth specification,
InfiniiMax: The world’s best
eliminating the distortion and loading that affect probes with in-band resonance. The
probing system enables engineers to utilize their oscilloscope’s entire bandwidth without
high-speed oscilloscope
being limited to measuring only 50 Ω transmission lines or using passive resistive divider probing system
probes that produce voltage measurement error and circuit loading. Designers can achieve EDN Magazine has awarded
system measurement bandwidths of 4.5 to 6 GHz even when manually “browsing” with the Keysight’s InfiniiMax active
probe. Solder-in probe heads and solder-in sockets provide even higher bandwidths. probe system the 2002
Innovation of the Year Award.
–– The Keysight InfiniiMax 1130A series probe system supports a wide variety of real-world
applications with an extensive line up of probe heads and accessories. The accessories
can meet the most demanding mechanical access requirements. Small probe heads can
be placed between densely packed PC boards. Solder-in sockets are available for signals
that need frequent measurement. A differential SMA probe head is available to connect
to fixtures that have SMA connections. A smart ergonomic design allows users to set the
spacing between the probe pins (variable span). When not concerned with minimum probe
size, designers can use a browsing sleeve to make holding the probe more comfortable.
Both probe tips of the differential probe can “flex” to support various probing angles and
target system characteristics (z-axis compliance). Innovative damped-wire accessories
compensate for the inductance and capacitance associated with the leads, and prevent
distortion of the measured signal.
–– The groundbreaking design of Keysight InfiniiMax 1130A probe system also enables users
to make either single-ended or differential measurements from a single probe amplifier,
depending on their choice of probe head and accessory. This can result in significant
savings in cost and time. The common mode rejection of the differential probe head
reduces a measurement’s noise floor. Overall, the Keysight 1130 series probing system
delivers unmatched performance, accuracy and connectivity.
InfiniiMax offers you the highest performance available for measuring differential
and single-ended signals
23 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Performance characteristics
1130A/31A/32A/34A
Probe Bandwidth* 1134A: > 7 GHz
1132A: > 5 GHz
1131A: > 3.5 GHz
1130A: > 1.5 GHz
Rise and fall time (10% to 90%) 1134A: 60 psec
1132A: 86 psec
1131A: 100 psec
1130A: 233 psec
System bandwidth (–3 dB) 1134A with DSO/DSA90604A: 6 GHz
1132A with DSO/DSA90404A, DSO/MSO9404A: 4 GHz
1131A with DSO/DSA90254A, DSO/MSO9254A: 2.5 GHz
1130A with DSO/MSO9104A: 1 GHz
1130A with DSO/MSO9064A: 600 MHz
Input capacitance** Cm = 0.1 pF Cm is between tips.
Cg = 0.34 pF Cg is to ground for each tip.
Cdiff = 0.27pF Differential mode capacitance = Cm + Cg/2
Cse = 0.44 pF Singe-ended mode capacitance = Cm + Cg
Input resistance* Differential mode resistance = 50 kΩ ± 1%
Single-ended mode resistance = 25 kΩ ± 1%
Input dynamic range ± 2.5 V
Input common mode range ± 6.75 V dc to 100 Hz; ± 1.25 V >100 Hz
Maximum signal slew rate 18 V/ns when probing a single-ended signal
30 V/ns when probing a differential signal
DC attenuation 10:1 ± 3% before calibration on oscilloscope
10:1 ± 1% after calibration on oscilloscope
Zero offset error referred to input < 30 mV before calibration on oscilloscope
< 5 mV after calibration on oscilloscope
Offset range* ± 12.0 V when probing single-ended
Offset accuracy < 3 % setting before calibration on oscilloscope
< 1 % setting after calibration on oscilloscope
Noise referred to input 3.0 mVrms
Propagation delay ~6 nsec (This delay can be deskewed relative to other signals.)
Maximum input voltage* 30 Vpeak, CAT I
ESD tolerance > 8 kV from 100 pF, 300 Ω HBM
* Denotes warranted specifications, all others are typical.
** Measured using the probe amplifier and solder-in differential probe head with full bandwidth resistors.
24 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Ordering information
InfiniiMax I probe amplifier models
Model number Description Quantity
1134A 7 GHz InfiniiMax Probe Amplifier (order one or more probe heads or connectivity kits per amplifier) 1
1132A 5 GHz InfiniiMax Probe Amplifier (order one or more probe heads or connectivity kits per amplifier) 1
1131A 3.5 GHz InfiniiMax Probe Amplifier (order one or more probe heads or connectivity kits per amplifier) 1
1130A 1.5 GHz InfiniiMax Probe Amplifier (order one or more probe heads or connectivity kits per amplifier) 1
InfiniiMax I adapters
Model number Description Quantity
N1022B Adapts 113X/115X active probes to 86100 Infiniium DCA 1
N2887A InfiniiMax Soft touch Pro probe adapter (36 channel, up to 4 GHz) 1
N2888A InfiniiMax Soft touch half-channel probe adapter (18 channel, up to 4 GHz) 1
25 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Utilizing low attenuation ratio setting (1.16:1), the adapter enables an extremely lower
noise floor, especially at high-sensitivity vertical scales (< 400 mV) when compared to
the Keysight InfiniiMax III probe with the N5444A SMA/2.92 mm head. The adapter is
compatible with Infiniium 90000Q, Z-Series, or V-Series with AutoProbe II interface.
10.0
1.0
0.1
10 mV/div 20 mV/div 50 mV/div 100 mV/div 200 mV/div 500mV/div 1 V/div
8 GHz 0.305 0.541 1.214 2.422 4.844 12.157 24.214
13 GHz 0.420 0.737 1.642 3.246 6.477 16.393 32.502
16 GHz 0.479 0.840 1.864 3.681 7.332 18.636 36.799
20 GHz 0.573 0.991 2.185 4.303 8.531 21.890 42.991
25 GHz 0.703 1.205 2.638 5.156 10.183 26.423 51.548
30 GHz 0.864 1.476 3.207 6.212 12.178 32.057 61.978
Eye diagram comparison with MIPI M-PHY Gear 3 data rate at 5.8304 Gb/s, amplitude swing:
= 140 mVpp
Figure 1. Direct signal connect to Infiniium scope Figure 2. Signal through N7010A active termination adapter; N7010A doesn’t
inherently contribute noise
27 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
–– A – B (differential),
–– A – ground (single-ended A)
–– B – ground (single-ended B)
–– (A+B)/2 – ground (common mode)
Ordering information
Model number Description
N2750A 1.5 GHz InfiniiMode differential probe
N2751A 3.5 GHz InfiniiMode differential probe
N2752A 6 GHz InfiniiMode differential probe
N2776A Differential browser tips (qty 3)
N2777A InfiniiMode solder-in tips (qty 3)
N2778A InfiniiMode socketed tips (qty 3)
N4822A Socketed tip for USB/ethernet application fixtures (qty 1)
The N2750A/51A/52A InfiniiMode probes include two browser tips, two socketed tips,
and two solder-in tips as standard. The N4822A is not included in the N2750A-52A probe.
N2750A with N4822A socketed tip for
application fixtures
Other recommended accessories
Model number Description
N2787A 3D probe positioner
E2655C Performance verification and deskew fixture
N5442A Precision BNC adapter for V-Series, 90000X/Q Series oscilloscopes
N2750A with browser tip N2750A with socketed tip N2750A with solder-in tip
For more information about the N2750A Series InfiniiMode probes, refer to the data
sheet with the Keysight literature number, 5991-0560EN.
30 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
–– High resistance (1 MΩ) and low Testing devices over extreme temperature
capacitance (1 pF) input for low ranges is quite common these days. The
loading N2797A 1.5 GHz single-ended active probe
–– Wide input dynamic range (± 8 V) and is the industry’s first low-cost high input
offset range (± 12 V for N2796A/97A, impedance active probe with rugged probe
± 8 V for N2795A) tips for environmental chamber testing of
–– Built-in headlight ICs and devices. The probe gives the ability
–– Direct connection to AutoProbe to probe signals at drastic temperature
interface (no power supply required) swings ranging from –40 to +85 °C. The
–– N2797A for extreme temperature probe provides a 2 m long cable. Order
environmental chamber testing at N2798A for re-ordering accessories.
–40 to +85 °C
The N2795A/96A/97A are equipped with
a white LED headlight to illuminate the
The N2795A/96A are a new generation of
circuit under test. The probes are powered
low-cost, 1 to 2 GHz single-ended active
directly by the Infiniium AutoProbe interface,
probes with the AutoProbe interface
eliminating the need for an additional
(compatible with Keysight’s Infiniium family
power supply. The probes also come with
of oscilloscopes). These probes integrate
a number of accessories that allow for
many of the characteristics needed for
easy connections to the circuit under test.
today’s general-purpose, high-speed
probing–especially in digital system design,
For more information about N2795A/96A/
component design/characterization, and
97A active probe, refer to the Keysight
educational research applications. Its 1 MΩ
N2795A/96A/97A active probe data sheet
input resistance and extremely low input
literature number 5990-6480EN.
capacitance (1 pF) provide ultra low
loading of the DUT. This, accompanied
with superior signal fidelity, makes these
probes useful for most of today’s digital
logic voltages.
Measurement plots
Frequency response of N2796A (Vout/Vin) Time domain step response of N2796A (with Keysight MSO9404A)
3.000 M
1.000 M
Impedance (Ohms)
100.0 k
10.00 k
1.000 k
100.0
Frequency (Hz)
Voltage derating over frequency (N2796A) Input impedance over frequency (Red = measured, Blue = model)
32 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Ordering information
Model number Description
N2795A 1 GHz single-ended active probe
N2796A 2 GHz single-ended active probe
N2797A 1.5 GHz single-ended active probe
Reorderable accessories
Model number Description Quantity
N4839A Dual-lead socketed adapter, 6 cm 2
N4840A Dual-lead solder-in adapter, 5 cm 2
N4841A Dual-lead socketed adapter, 9 cm 2
N4842A Dual-pin PCB header 2
N4843A Solderable tips 10
N4844A Right angle ground lead, 5 cm 2
N4845A Ground blade 2
N4846A Offset ground 2
The N7020A power rail probe is a low noise, large offset range oscilloscope probe that
enables users to measure small signals riding on top of DC power supplies.
–– Low noise: The N7020A power rail probe is a 1:1 attenuation ratio active probe.
As a general rule, the higher a probes attenuation ratio, the nosier the signal will be
on the oscilloscope.
–– Large offset range: The N7020A power rail probe provides ± 24V of probe offset.
This enables users to center the signal on screen while placing the oscilloscope at
its maximum vertical sensitivity and zoom-in on the signal.
–– Low DC loading: The N7020A power rail probe has 50 kΩ input impedance at DC,
minimizing the probe’s DC loading of the power rail.
–– Large input dynamic range: The N7020A power rail probes ± 850 mV input dynamic
range means that users can measure up to 850 mV deviations of their DC supplies.
This is very useful for measuring programmable supplies like those used in
micro-controller power saving modes.
For more information about the N7020A power rail probe, check out the Keysight data
sheet with the publication number 5992-0141EN.
34 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Oscilloscope users often need to make floating measurements where neither point of
the measurement is at earth ground. Use N2790A, N2791A, or N2891A high voltage
differential probes to make safe and accurate floating measurements with an oscilloscope.
The N2790A, N2791A, and N2891A high voltage differential probes allow conventional
earth-grounded Keysight oscilloscopes to be used for floating signal measurements.
Each probe offers user-selectable attenuation settings that make it highly versatile, N2790A 100 MHz high voltage differential probe
allowing it to be used for a broad range of applications. The probe comes with probe tip
accessories for use with small and large components in tight spaces.
The N2791A and N2891A are compatible with any oscilloscope with 1 MΩ BNC input.
The N2791A and N2891A probe power is supplied by the included 4x AA batteries or
the USB host port of the scope, or PC via a supplied USB power cable. The N2790A is
compatible with the Keysight’s AutoProbe interface where the probe power is supplied
by the Keysight oscilloscope’s probe interface. The N2790A is not compatible with
80000 and 90000 Series oscilloscope.
The N2804A and N2805A differential probes provide the superior general-purpose
differential signal measurements that are required for high-speed power measurements
such as measuring characteristics of switching power devices, DC-DC converters or
class D amplifiers, vehicle bus measurements, and high-speed digital system designs.
The N2804A 300-MHz differential probe offers 100:1 attenuation ratio, allowing it to
be used adequately for high voltage signal measurements. The differential probe has a
differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit
loading. The probe comes with a pair of extension leads (30 cm long) with a damping
resistor built in to damp out the in-band resonance and provide flat frequency response
even while using the extension leads and probe tip accessories.
N2804A N2805A
Bandwidth 300 MHz (without extension leads) 200 MHz
120 MHz (with extension leads)
Attenuation ratio 100:1 50:1
DC gain accuracy ± 1% ± 1%
Input impedance (between inputs) 4 MΩ / 4 pF 4 MΩ / 4 pF
Max input voltage (between two inputs) ± 300 V (DC+ peak AC) and ± 200 Vrms ± 200 V (DC+ peak AC) and ± 200 Vrms CAT II
Max input voltage ± 300 V (DC+ peak AC) and ± 200 Vrms CATII ± 500 V (DC+ peak AC) and ± 500 Vrms CAT I
± 1000 V (DC+ peak AC) and ± 1000 Vrms CATI ± 300 V (DC+ peak AC) and ± 200 Vrms CATII
Cable length 1.2 m 5m
Compatible Infiniium oscilloscopes Infiniium S-Series, 9000, 90000 Series with software 5.2 or higher
N2804A 300 MHz differential probe N2805A 200 MHz differential probe
36 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The 1153A is the same 1:1 differential probe with 200 MHz as the 1141A except that it
is compatible with the AutoProbe interface, which completely configures the Infiniium
scope for the probe. The probe interface recognizes the probe and automatically sets up
the proper power, coupling mode, 50 Ω impedance and offset range. The 1142A probe
power supply is unnecessary with the 1153A. The probe works with Infiniium 9000,
90000A and 90000X with N5442A.
The N2818A and N2819A probes offer a 10:1 attenuation setting and high input
resistance and low input capacitance to minimize circuit loading.
The 1146B ac/dc current probe provides accurate display and measurement of currents
from 100 mA to 100 Arms, dc to 100 kHz, without breaking into the circuit. A battery
level indicator and overload indicator help ensure proper readings. It connects directly to
the scope through a 2-m coaxial cable with an insulated BNC. This probe works with any
1 MΩ input oscilloscope.
Ordering information
Model number Description
1146B 100-kHz current probe
39 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The 1147B/N2893A probe is compatible with the AutoProbe interface, which completely
configures the oscilloscope for the probe when used with the Infiniium 9000 Series scope
(1 MΩ input). Probe power is provided by the scope, so there is no need for an external
power supply. The N2893A uniquely provides an auto demagnetization and offset
elimination feature when used in conjunction with Infiniium scope. The 1147B and
N2893A are not compatible with Infiniium 80000 and 90000 Series oscilloscope.
Ordering information
Model number Description
1147B 50-MHz current probe with AutoProbe interface
N2893A 100-MHz current probe with AutoProbe interface
40 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The N2780B/L Series current probes are Operating characteristics of the N2780B/L Series current probes
high bandwidth, active current probes,
featuring flat bandwidth, low noise N2780B/L Series
(2.5 mArms) and low circuit insertion Bandwidth (–3 dB) dc to 2 MHz (N2780B)
loss. Compatible with any oscilloscope dc to 10 MHz (N2781B)
with a 1 MΩ BNC input, the N2780B/L dc to 50 MHz (N2782B)
Series current probes offer accurate and dc to 100 MHz (N2783B)
reliable solution for measuring DC and AC dc to 80 MHz (N2783L)
currents. Because of the split-core design, Maximum current (continuous) 500 A (N2780B)
they can easily clip on and off of a wire In 150 A (N2781B)
conjunction with the power supply (model 30 A (N2782B/N2783B/N2783L)
N2779A), this probe can be used with
Maximum peak current (non-continuous) 700 A peak (N2780B)
any oscilloscope with a high-impedance
300 A peak (N2781B)
BNC input. The companion power supply
50 A peak (N2782B/N2783B/N2783L)
N2779A (3 x 12 ± Vdc output) lets you
connect up to any three N2780B-83B/83L Maximum input voltage** 300 V CAT I (N2782B, 83B, 83L)
current probes to a single power supply. 300 V CAT III, 600 V
CAT II (N2780B, 81B)
The N2783L 80 MHz current probe offers Output voltage rate 0.01 V/A (N2780B/N2781B)
5 m long cable, which allows you to 0.1 V/A (N2782B/N2783B /N2783L)
reach DUTs in long distance very easily. Amplitude accuracy* ± 1.0 % rdg ± 500 mA (N2780B)
Other than the bandwidth performance, ± 1.0 % rdg ± 100 mA (N2781B)
the N2783A and N2783L have the same ± 1.0 % rdg ± 10 mA (N2782B)
electrical performance. The N2783L also ± 1.0 % rdg ± 10 mA (N2783B/N2893L)
requires the N2779A power supply to
* The amplitude accuracy specification is guaranteed at 23 °C ± 3 °C (or 73 °F ± 5 °F).
power the probe. ** Insulated conductor should be used.
Ordering information
Model Description
number
N2780B 2-MHz current probe
N2781B 10-MHz current probe
N2782B 50-MHz current probe
N2783B 100-MHz current probe
N2779A Power supply for the
N2780B/81B/82B/83B/83L
current probes
N2783L 80-MHz current probe with
5 m cable
The N2820A 2-channel current probe connects to two oscilloscope channels to provide simultaneous
low- and high-gain views for wider dynamic range measurement.
42 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Ordering information
Model numbers Descriptions
N2820A High-sensitivity 2-ch current probe
N2821A High-sensitivity 1-ch current probe
Replacement part numbers
N2822A 20 mΩ resistor tips
N2824A 100 mΩ resistor tips
N2825A User-defined resistor tips
N2826A Replacement wires (15.5 cm, 22 AWG bare wires) (qty 5)
N2827A Passive cable (for N2820A secondary channel)
N2828A Replacement MBB (Make Before Break) headers (qty 5)
N2829A Replacement MBB (Make Before Break) receptacles and 15.5 cm, AWG 22 socketed wires (qty 5 each)
43 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The N2870A Series passive probe family sets new standards in high performance probing
of up to 1.5 GHz bandwidth. These general purpose probes and accessories offer high
quality measurements at a very reasonable price.
N2873A 500 MHz passive probe with standard
accessories
Compact 2.5-mm probe head diameter, low input capacitance, and various fine-pitch
probe tip accessories make the Keysight N2870A Series passive probes ideal for probing
densely populated IC components or surface-mount devices used in today’s high-speed
digital applications. The sharp probe tip is spring loaded to help engineers keep the
probe from slipping off the device under test. Insulating IC caps keep the small probe
tip centered on the IC lead and keep it from shorting adjacent leads. Standard flat blade
ground connector and self-adhesive copper ground pads help reduce ground inductance,
while offering easy ground access. Optional probe tip accessories provide specialized
capabilities for demanding applications.
The N2873A 500 MHz passive probe ships with Keysight’s 9000 and S-Series Infiniium
oscilloscope.
Electrical characteristics
Model number Bandwidth Attenuation Input C Input R* Max input Scope input Scope comp
(–3 dB) ratio* (Scope and voltage coupling range
probe) (AC RMS)
N2870A 35 MHz 1:1 39 pF 1 MΩ 55 V CAT II 1 MΩ –
(+oscilloscope)
N2871A 200 MHz 10:1 9.5 pF 10 MΩ 400 V CAT I 1 MΩ 10-25 pF
300 V CAT II
N2872A 350 MHz 10:1 9.5 pF 10 MΩ 400 V CAT I 1 MΩ 10-25 pF
300 V CAT II
N2873A 500 MHz 10:1 9.5 pF 10 MΩ 400 V CAT I 1 MΩ 10-25 pF
300 V CAT II
N2874A 1.5 GHz 10:1 1.8 pF 500 Ω 8.5 V CAT I 50 Ω —
N2875A 500 MHz 20:1 5.6 pF 20 MΩ 400 V CAT I 1 MΩ 7-20 pF
300 V CAT II
N2876A 1.5 GHz 100:1 2.2 pF 5 kΩ 21 V CAT I 50 Ω —
* Denotes warranted specifications, all others are typical. Attenuation ratio = ± 2% at DC, Input R (probe only, N2870A excluded) = ± 1%
Common to all
Probe ID readout: Compatible with Keysight’s InfiniiVision and Infiniium Series oscilloscopes
44 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
N4837A
N4838A
N4863A
N4864A
45 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Standard accessories
N2871A, N2872A, N2873A, N2875A N2870A N2874A, N2876A
Rigid probe tips, qty 2 ■ ■ ■
Spring-loaded probe tips, qty 2 ■ ■ ■
Sprung hook 2.5 mm ■ ■
Short sprung hook 2.5 mm ■
Ground blade 2.5 mm with 2 copper pads ■ ■ ■
IC cap 2.5-0.5 mm green ■ ■ ■
IC cap 2.5-0.65 mm blue ■ ■ ■
IC cap 2.5-0.8 mm gray ■ ■ ■
IC cap 2.5-1.0 mm brown ■ ■ ■
IC cap 2.5-1.27 mm black ■ ■ ■
Insulating cap 2.5 mm ■ ■ ■
Protection cap 2.5 mm ■ ■ ■
BNC adapter 2.5 mm ■ ■ ■
Ground spring 2.5 mm ■ ■ ■
Ground lead 15 cm ■ ■ ■
Trimmer tool ■
Color coded rings 3x4 ■ ■ ■
User’s guide manual ■ ■ ■
For other re-orderable accessories for N2870A-76A passive probes, check out the product web page on
www.keysight.com/find/probes.
46 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
These general purpose replacement devices are built and tested for high reliability.
Kevlar strengthener has been added to the probe cable for extra pull strength. Durable
probe tips are replaceable.
The compact design significantly reduces the problem of probing densely populated
integrated circuit components or the characteristically minute conductors on printed
circuit boards. These small, lightweight probes allow measurements that were previously
difficult, while reducing the danger of shorting. For tight probing areas, the probe handle
can be unscrewed and pulled back along the cable.
When probing about the circuit in debug mode, the probes easily slip inside the included
browsers. The browsers feature a crown point that digs into solder and avoids the danger
of slipping off the test point and shorting to adjacent leads. A pogo pin allows hand
movement on the probes without losing contact with the device under test.
A snap-on BNC connector simplifies attaching the probe to the scope. Leads are
available for connecting to a wide variety of test points. See “Ordering Information”
for a complete list.
Electrical characteristics
Model Type of probe System bandwidth Division Input R Input C Scope Comp Length
number (scope+probe) ratio input R range
1165A High impedance, 600 MHz typical with 10:1 10 MΩ 10 pF 1 MΩ 12 - 14 pF 1.5 m
passive 54830B/31B/32B/33A
54830D/31D/32D/33D
One probe
One screwdriver
The Keysight 54006A allows you to probe signals up to 6 GHz using replaceable tips that
provide either 10:1 division ratio with 500 Ω input resistance, or a 20:1 division ratio with
1 kΩ input resistance. This 6 GHz probe gives access to circuit nodes that are not 50 Ω
or do not have 50 Ω connectors allowing you to see signals at specific points, such as
the input to a gate. Keysight 54006A’s input capacitive loading is approximately 0.25 pF,
allowing you to get very accurate timing measurements for a wide bandwidths of signals.
The 54006A probe is a good, low-cost alternative for high-frequency probing where the
higher resistive loading is not an issue and the other features of the InfiniiMax probing
system are not needed (such as differential inputs and multiple connectivity options).
Ordering information
Model Description Quantity
number
54006A* 6 GHz resistor divider probe 1
Includes:
One 10:1 500 Ω probe body, six 450 Ω resistors,
One 20:1, 1 kΩ probe body, six 950 Ω resistors,
One 36 in, 50 Ω coaxial cable, SMA (m-m)
One blocking cap, 10 GHz-26 GHz APC - 3,5 (m-f)
* Requires the 54855-67604 SMA to precision-BNC adapter to connect to BNC scope input
The Keysight 10076C 4 kV 100:1 passive probe gives you the voltage and bandwidth
you need for making high-voltage measurements. Its compact design makes it easier to
probe today’s small power electronics components and its rugged construction means it
can withstand rough handling without breaking.
The 10076C is compatible with any oscilloscope with 1 MΩ BNC input. For use with the
Infiniium 90000 Series scope, use the E2697A high impedance probe adapter. For use 10076C passive probe
with the Infiniium 90000 X- and 90000 Q-Series scope, use the N5449A high impedance
probe adapter.
Ordering information
Model Description Quantity
number
10076C High-voltage probe: includes one retractable hook tip, 1
one‑ground‑bayonet, one IC probing tip, one‑alligator ground
lead and a compensation screwdriver
10077A Accessory kit for 10076B/C including 1x retractable hook pin, 1
1x ground lead, 1x insulation cap, 2x measuring pins and 8x ID tags
N2789A Spring ground tip for 10076B/C 1
10076C derating curve
50 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The N2771B is a 1000:1 divider probe for the measurement of fast high voltage signals
up to 30 kV dc + peak ac, 10 kV rms.
The probe’s large size and rugged construction provide superior protection. The ground
lead is fed through the body of the probe and protrudes behind the safety barrier,
keeping the ground connection away from the high voltage. Typical applications include
PMTs, motor drives, high voltage switches, magnatrons, and modern projection systems.
N2771B high-voltage probe
The N2771B is compatible with any oscilloscope with 1 MΩ BNC input. For use with the
Infiniium 90000 Series scope, use the E2697A high impedance probe adapter. For use
with the Infiniium 90000X and 90000 Q-Series scope, use the N5449A high impedance
probe adapter.
Ordering information
Model Description Quantity
number
N2771B High-voltage probe: includes alligator ground lead, 1‑sharp‑probe tip 1
51 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The Infiniium MSO9000A and S-Series come with a 54826-68701 16-channel logic
probe kit containing a 40-pin (F) to 40-pin (F) logic probe cable assembly (or external
digital cable), 2-inch ground leads (qty 5), SMT IC clips (qty 20) and a 16-channel flying
lead probe tip assembly. The standard cable gives the MSO the standard 40-pin female SMT IC clip
input connector that many Keysight logic analyzers have. With this cable, a user can (part number 5090-4833)
connect a wide variety of logic analyzer probes such as Mictor, Samtec, and Soft Touch
probes. For information on these probes, see Probing solutions for logic analyzers (with
Keysight literature number 5968-4632E).
For optimal signal fidelity, connect ground at each logic probe, in addition to taking a
common ground to all eight signals via a separate ground connector on the probe pod.
The 9000 MSO digital channels were architected to be compatible with a wide variety of
probing accessories developed over 20 years for logic analyzers. There’s a good chance
that the logic analyzer accessories you already own work with your MSO. With the
standard 40-pin cable that comes with your MSO, the MSO accepts numerous logic
analyzer accessories including:
For logic accessories of greater channel width than MSO digital channels (> 16 channels),
there are two use models.
–– Route up to 16 signals to the probe and don’t use the additional probe channels.
–– Route up to 32 signals to the probe and measure ½ of them at a time. Simply plug
the 40-pin cable to the other side of the probe to see the other ½ of the signals.
InfiniiMax probe with N5450B extreme N2880A InfiniiMax in-line attenuator N2884A InfiniiMax fine-wire probe
temperature extension cable (probe amplifier and head not included) tip (ZIF probe head not included)
54 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The N2784A and N2785A probe positioners provide quick and stable X-Y positioning for
PC boards and devices that require hands-free probing.
Unlike other probe positioners that require multiple adjustments to lock the probe holder
into position, the N2784A and N2785A need only the “lift and drop” motion to put the
probe in place. The weight stabilization technique used in these probe holders keeps
constant pressure at the probing point so the probe tip stays in position even when the
target board is bumped.
The N2786A is a low cost, easy-to-use XY axis probe holder for general purpose probing
applications. The two-leffed positioner is designed to be easy to use–the positioner itself
has no controls to positioner it in place. N2786A 2-leg probe positioner
The N2787A is a 3D probe positioner with a flexible, articulating arm that can be quickly
positioned in a variety of configurations.
For more information about Keysight’s probe positioners, refer to literature number
5989-9131EN.
Ordering information
Product number Description
N2784A* 1-arm probe positioner
N2785A* 2-arm probe positioner
N2787A 3D probe positioner
N2786A 2-leg probe positioner
N2787A 3D probe positioner
* Includes 3x magnifying glass, arm strap, cable tie, probe rest, and manual
designed with you in mind. E2614A 0.5 mm Wedge probe adapter, 8 signal 1
E2643A 0.5 mm Wedge probe adapter, 16 signal 1
Make the inaccessible E2615A 0.65 mm Wedge probe adapter, 3 signal 1
accessible E2616A 0.65 mm Wedge probe adapter, 8 signal 1
When you use the Wedge, you don’t have E2644A 0.65 mm Wedge probe adapter, 16 signal 1
to worry about shorting IC pins together 10072A SMT kit for 10070 probe family
on a delicate component–or worse yet, 10075A 0.5 mm IC clip kit
on an irreplaceable prototype. The Wedge
is easy to insert and it stays put. There’s
no need to solder small wires onto leads. Electrical reliability IC clip kits
The Wedge is mechanically non-invasive,
so you won’t damage the legs of the IC. The Wedge makes two contact points As an inexpensive solution for probing
Instead, you’ll have easy access to with each leg of the IC. This redundant fine-pitch ICs, the 10072A SMT Kit
hard-to-reach components. physical connection increases the electri- includes 10 IC clips and 2 dual-lead
cal reliability of the connection. Also the adapters that connect the clips directly
Wedge’s low capacitance and inductance to 10070-family probes.
provides superior performance to many
other alternatives. The 10075A 0.5‑mm IC clip kit is ideal
for connecting to IC’s as fine as 0.5 mm.
The Wedge probe adapter connects The clip body allows many clips to be
directly to 1145A/1155A active probes mounted side-by-side. The kit includes
and the dual lead adapter provided with four 0.5‑mm IC clips and two dual-lead
the 1160A-65A passive probe family and adapters that connect the IC clips directly
N2877A/N2879A accessory kits for use to 10070-family probes.
with N287xA Series passive probes.
57 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
The E2697A high impedance adapter allows connection of probes that require a 1 MΩ
high impedance input (e.g., passive probes, current probes) to the Infiniium 54850,
80000 and 90000 Series oscilloscopes. The E2697A high impedance adapter extends the
capability of Keysight Infiniium high-performance oscilloscopes, making them ideal for
a variety of general-purpose measurements such as power supplies, inverters, semicon-
ductor devices, etc. The E2697A provides switchable AC/DC coupling, as well as 10:1
and 1:1 attenuation settings. Use the N5449A high impedance adapter with Infiniium
90000X and 90000Q Series scopes.
58 | Keysight | Infiniium Oscilloscope Probes and Accessories – Data Sheet
Related Literature