Air Treatment and Recirculation Systems

The document discusses different models of air treatment and recirculation systems. It describes single-fan and single-duct models that provide thermal power and air flow using a single fan and duct. It also describes double-fan models that can use two diffusion ducts or double blowing fans to convey air into a single duct. Additionally, it discusses single blowing fan and single duct angular models that have a semicircular duct for use in spaces with height limitations.

Uploaded by

Nenad Živić
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views12 pages

Air Treatment and Recirculation Systems

The document discusses different models of air treatment and recirculation systems. It describes single-fan and single-duct models that provide thermal power and air flow using a single fan and duct. It also describes double-fan models that can use two diffusion ducts or double blowing fans to convey air into a single duct. Additionally, it discusses single blowing fan and single duct angular models that have a semicircular duct for use in spaces with height limitations.

Uploaded by

Nenad Živić
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

AIR TREATMENT AND

RECIRCULATION SYSTEMS
Air treatment and recirculation systems

Index

02 Air treatment and recirculation systems

03 Applications

04 Single-fan and single-duct models

05 Double-fan and double duct or double


blowing fan and single duct models

06 Single blowing fan and single


duct angular models

07 Double blowing fan and single


duct angular models

01
Roen Est Unit Coolers

AIR TREATMENT
AND RECIRCULATION SYSTEMS

These air treatment and distribution The system is supplied for ceiling Generally speaking, standard air coolers
systems consist of special air cooling installation complete with fasteners feature a cubic design, but in case of height
units combined with fabric diffusion ducts. for the diffusion ducts. limitations we can build angular models with
The assembly is designed to provide On request, air intake filters, electronically blowing fans and a single semicircular duct.
the required thermal power and air flow controlled fans, and reheating with
rate, achieving optimal diffusion while finned tube heat exchanger coil or
minimising noise and power consumption. electric resistances can be supplied.
The air cooler is made with a double If the system provides for two fans, you
insulated tray, pre-painted aluminium can choose the solution with two diffusion
casing, stainless steel metalwork and ducts or with blowing fans to convey
diffusers with anti-condensation treatment. the entire air flow into a single duct.

02
Air treatment and recirculation systems

APPLICATIONS
The application is particularly suitable for:
ØØprocessing rooms
ØØloading and unloading areas
ØØcold store access areas
ØØageing rooms
ØØindustrial air conditioning

03
Roen Est Unit Coolers

SINGLE-FAN AND SINGLE-DUCT MODELS

Indicative above-ground dimensions:


Duct lenght (5)
Sound pressure
capacity (1) (2)

capacity (3) (4)

consumption
level at 5m
Nominal

Nominal
Air flow

MODEL
Power

l d h

m3/h kW kW dB(A) W mm m

C1-2.5 2500 18 10 38 150 1250 900 850 3 to 15 m

C1-5.0 5000 28 16 47 400 1550 1100 1300 5 to 20 m

C1-10.0 10000 70 40 51 900 2650 1100 1300 10 to 40 m

C1-15.0 15000 105 60 52 1900 2650 1100 1400 10 to 50 m

C1-20.0 20000 140 80 53 2000 3200 1300 1700 15 to 60 m

Cooling power
(1) R410A Tev = 7°C and Tair = 26°C 52% (3) R404A, SC1: Tev = 0°C, Tair =10°C RH 85%
(2) Chilled water T = 7/12°C and Tair = 26°C 52% (4) ETHYLENE GLYCOL 15%, SC7: T = 4/8°C, Tair = 16°C RH 70%

04
Air treatment and recirculation systems

DOUBLE-FAN AND DOUBLE DUCT OR DOUBLE BLOWING FAN


AND SINGLE DUCT MODELS

Indicative above-ground dimensions:


Duct lenght (5)
Sound pressure
capacity (1) (2)

capacity (3) (4)

consumption
level at 5m
Nominal

Nominal
Air flow

MODEL
Power

l d h

m3/h kW kW dB(A) W mm m

C2-5.0 5000 35 20 41 300 2150 900 850 3 to 15 m

C2-12.0 12000 81 46 51 1400 2650 1100 1300 5 to 20 m

C2-20.0 20000 140 80 54 1800 4850 1100 1300 10 to 40 m

C2-30.0 30000 210 120 55 3800 4850 1100 1400 10 to 50 m

C2-40.0 40000 280 160 56 4000 5950 1300 1700 15 to 60 m

Diffusion ducts
(5) Made in polyester " Trevira " of class 1 fire-retardant

05
Roen Est Unit Coolers

SINGLE BLOWING FAN AND SINGLE DUCT ANGULAR MODELS

Indicative above-ground dimensions:


Duct lenght (5)
Sound pressure
capacity (1) (2)

capacity (3) (4)

consumption
level at 5m
Nominal

Nominal
Air flow

MODEL
Power

l d h

m /h
3
kW kW dB(A) W mm m

A1-1,7 1700 11 6 47 140 1200 800 410 3 to 15 m

A1-5.0 5000 33 19 47 660 1800 1100 740 3 to 15 m

A1-8.0 8000 49 28 48 1000 2150 1350 810 5 to 20 m

Cooling power
(1) R410A Tev = 7°C and Tair = 26°C 52% (3) R404A, SC1: Tev = 0°C, Tair =10°C RH 85%
(2) Chilled water T = 7/12°C and Tair = 26°C 52% (4) ETHYLENE GLYCOL 15%, SC7: T = 4/8°C, Tair = 16°C RH 70%

06
Air treatment and recirculation systems

DOUBLE BLOWING FAN AND SINGLE DUCT ANGULAR MODELS

Indicative above-ground dimensions:


Duct lenght (5)
Sound pressure
capacity (1) (2)

capacity (3) (4)

consumption
level at 5m
Nominal

Nominal
Air flow

MODEL
Power

l d h

m /h
3
kW kW dB(A) W mm m

A2-3,4 3400 21 12 50 280 2100 800 410 3 to 15 m

A2-10.0 10000 67 38 50 1320 3250 1100 740 3 to 15 m

A2-16.0 16000 98 56 51 2000 4050 1350 810 5 to 20 m

Diffusion ducts
(5) Made in polyester " Trevira " of class 1 fire-retardant

07
Roen Est Unit Coolers

Last update:
July 2019

08
REV. 01/2019
Roen Est S.p.A.