FD-M10AT Datasheet
FD-M10AT Datasheet
Sheet
FDM10AT
Main Unit, Portrait, 10 L/min, NPN
SPECIFICATIONS
Model FDM10AT*1
Type For vertical piping
Shape Builtin amplifier
Rated flow range 0.5 to 10 L/min*2*3
Possible display range 0.5 to 30 L/min*4
Possible ranges to set 0 to 30 L/min
Zerocut flow rate 0.5 L/min*5
Connection diameter Rc3/8 (10A)
Allowable fluid Water or noncorrosive liquid
Conductivity of detection fluids 5 µS/cm or higher
Detection fluid temperature 0 to +85°C (No freezing)
Pressure loss 0.01 MPa or less
Display power Dual row display with 4digit, 7 segment LED, bar display (2 colours), output indicators, flow indicator
Display resolution 0.01/0.1 (L/min) selectable
Repeatability 0.5 s : ±5% of F.S.10 s : ±1% of F.S.1 s : ±3.5% of F.S.30 s : ±0.8% of F.S.2.5 s : ±2.5% of F.S.60 s : ±0.6% of F.S.5
s : ±1.6% of F.S.*6
Hysteresis Variable
Response time (chatter prevention feature) 500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s variable
Accumulated flow unit 0.01/0.1/1/10/100 (L) selectable
Accumulation data storage cycle Save to memory every 10 seconds
Memory backup EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)
Control output NPN open collector, max. 100 mA/ch*7 (40 V or less), residual voltage 1 V or less, 3 outputs (N.O./N.C. switchable)
Analogue output 420 mA, max. load resistance 260Ω, Analogue output range can be set to any value
Integration reset/bank switch input/flow zero function input Input time : 20 ms or greater, Either accumulation reset or bank switching mode can be selected
Power/current consumption Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)
Pressure resistance 2.0 MPa
Applied pressure range 1.0 MPa or less
Ambient temperature 0 to +50 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Accessories Instruction manual
Weight Approx. 835 g
*1 The models with “A” at the end of the name have additional functions such as display averaging.
*2 The rated flow range indicates the range that is supposed to be used in general.
*3 The rated flow range indicates recommended operating range.
*4 Can be used within the display range as well as within the rated flow range.
*5 Flow under the zero cut flow will be displayed as 0 L/min.
*6 The repeatability for FDM10AT (P)/Y (P) in the range of 20 to 30 L/min is the double of the value listed in the table.
*7 Maximum 20 mA for alarm output.
Dimensions
* Download CAD file or product manual for larger image/text and more detail.