This document provides specifications for the FD-M10AT main unit, a flow meter for vertical piping with a rated flow range of 0.5 to 10 L/min. It lists technical details such as the connection diameter, allowable fluids, operating temperature range, accuracy ratings, output and control options, power requirements, and materials. Dimensions and accessories are also noted.

Uploaded by

Nguyen Vansu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
179 views

FD-M10AT Datasheet

This document provides specifications for the FD-M10AT main unit, a flow meter for vertical piping with a rated flow range of 0.5 to 10 L/min. It lists technical details such as the connection diameter, allowable fluids, operating temperature range, accuracy ratings, output and control options, power requirements, and materials. Dimensions and accessories are also noted.

Uploaded by

Nguyen Vansu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Data 

Sheet

FD­M10AT
Main Unit, Portrait, 10 L/min, NPN

SPECIFICATIONS

Model FD­M10AT*1

Type For vertical piping

Shape Built­in amplifier

Rated flow range 0.5 to 10 L/min*2*3

Possible display range 0.5 to 30 L/min*4

Possible ranges to set 0 to 30 L/min

Zero­cut flow rate 0.5 L/min*5

Connection diameter Rc3/8 (10A)

Allowable fluid Water or non­corrosive liquid

Conductivity of detection fluids 5 µS/cm or higher

Detection fluid temperature 0 to +85°C (No freezing)

Pressure loss 0.01 MPa or less

Display power Dual row display with 4­digit, 7 segment LED, bar display (2 colours), output indicators, flow indicator

Display resolution 0.01/0.1 (L/min) selectable

Repeatability 0.5 s : ±5% of F.S.10 s : ±1% of F.S.1 s : ±3.5% of F.S.30 s : ±0.8% of F.S.2.5 s : ±2.5% of F.S.60 s : ±0.6% of F.S.5 
s : ±1.6% of F.S.*6

Hysteresis Variable

Response time (chatter prevention feature) 500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s variable

Accumulated flow unit 0.01/0.1/1/10/100 (L) selectable

Accumulation data storage cycle Save to memory every 10 seconds

Memory backup EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)

Control output NPN open collector, max. 100 mA/ch*7 (40 V or less), residual voltage 1 V or less, 3 outputs (N.O./N.C. switchable)

Analogue output 4­20 mA, max. load resistance 260Ω, Analogue output range can be set to any value

Integration reset/bank switch input/flow zero function input Input time : 20 ms or greater, Either accumulation reset or bank switching mode can be selected

Power/current consumption Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)

Rating Power voltage 24 VDC, Ripple (P­P) 10 % or less

Environmental resistance Enclosure rating IP65

Pressure resistance 2.0 MPa

Applied pressure range 1.0 MPa or less

Ambient temperature 0 to +50 °C (No freezing)

Relative humidity 35 to 85 % RH (No condensation)

Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material Liquid end materials Bore : SCS13, Measurement pipe : PPS, O ring : fluoro­rubber (FKM)

Material properties Other parts Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC

Accessories Instruction manual

Weight Approx. 835 g
*1 The models with “A” at the end of the name have additional functions such as display averaging.
*2 The rated flow range indicates the range that is supposed to be used in general.
*3 The rated flow range indicates recommended operating range.
*4 Can be used within the display range as well as within the rated flow range.
*5 Flow under the zero cut flow will be displayed as 0 L/min.
*6 The repeatability for FD­M10AT (P)/Y (P) in the range of 20 to 30 L/min is the double of the value listed in the table.
*7 Maximum 20 mA for alarm output.

KEYENCE CANADA 1­888­539­3623 https://www.keyence.ca/ 2020/06/05 Page:1/2