Readme
Readme
0
May 2009
The OTI Development Team is pleased to provide you with the enclosed ETAP 7.0.0 release. ETAP 7.0.0
is a complete program and does not require any previous ETAP installation.
ETAP 7.0.0 is a major release that delivers new design and analysis innovation to a new level of
advancement and provides the platform upon which future ETAP innovation will follow. This version
adds new powerful analysis modules and time-saving capabilities to the ETAP Suite. The new
enhancements and analysis modules are still developed with mathematical precision using our Quality
Assured Verification and Validation Procedure.
The first time you run ETAP 7.0.0, you will need to enter the 36-Digit Activation Code as provided on
the ETAP 7.0.0 installation DVD.
For more information on this new release, please take a few moments to review the information below.
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
1
1. One-Line Diagram
Templates
This upgrade provides the ability to create and recall unlimited graphical templates. Create template
versions of common electrical network configurations such as breaker-and-a-half, double-ended
substation, and spot network. Utilize templates to quickly construct an entire electrical network faster than
ever before with a single click. Create new online diagram templates or select from more 40 pre-built
ANSI and IEC templates.
Features
• Create & Utilize unlimited one-line templates
• Share templates created by other ETAP engineers
• Use default project ID or template ID
• Use properties from default project or template
• Instant preview of templates
Auto Select
One of the new innovations to the One-Line Diagram is the inclusion of the Graphical Auto Selection
tool. Graphical Auto Selection provides the capability to move the associated components with a simple
mouse stroke (shortcut Alt+Click). For example, selecting a Motor Control Center (MCC) bus
automatically selects the loads and protective devices connected to that bus. These related elements are
automatically grouped for quicker one-line layouts.
Features
• Intelligent load & feeder selection designed for electrical systems
• Works with bus, branch, loads, & protective devices
• Auto-grouping & ungrouping
Symbol Library
Substitute default one-line diagram symbols with an alternative symbol set for individual device types.
Need a SCADA look for your circuit breakers? Launch the symbol substitution tool and swap symbol sets
with the press of a button. Symbol substitution allows you to store and recall the default symbols at any
point in time.
Features
• Instant preview of alternative symbols
• Instantly create a new look on the one-line diagram
• New SCADA and IEC standard symbols
Keyboard Shortcuts
ETAP 7.0 includes a large array of keyboard shortcuts, which saves time and effort in creating and
editing.
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
2
2. Arc Flash
ETAP 7.0 brings you new and enhanced capabilities which allow for faster and easier performance of arc
flash hazard analysis. Identify and analyze high risk arc flash areas in your electrical system with greater
flexibility by simulating various incident energy mitigation methods. Arc Flash is a completely integrated
module that solves multiple scenarios to determine worst case incident energy levels and it also produces
professional reports and high quality arc flash labels at a press of a button.
Features
• Automatic consideration of generator AC decay & decrement curve
• AC motor short-circuit current decay handling
• Time varying fault clearing time calculation short-circuit current decay
• Arc flash calculations for 3-phase & 1-phase panel / UPS systems
• Radial & multiple source system handling
• Extended search beyond the point of multiple upstream source
• Automatic or User-defined source protective device search algorithm option
• Modeling of differential relays, maintenance mode switches, & arc flash photo-sensors
• Zone Selective Interlock Protection (ZSIP) representation
• Three phase and single phase systems
• User-Interface for defining hazard categories (NFPA 70E 2000, 2004, & 2009) or customize
based on your safety program requirements
• Generate IEEE 1584 & NFPA 70E look-up table results for different working distances &
generate simple summary reports to communicate the results to personnel
• Alerts for PPE ATPV rating violations (maximum allowable PPE arc rating alerts)
• Find the safest mode of operation for maintenance work
• Automatically batch print arc flash labels based on highest incident energy from all operating
modes
Features
• Sort results from different studies by multiple criteria
• Find the worst-case incident energy results
• Quickly isolate & identify arc flash mis-coordination
• Find which protective devices failed to operate
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
3
• Filter out & analyze only the higher hazard category results
• Filter out all equipment with % Ia variation problems
• Locate slow responding protective devices
• Export customized arc flash results to Excel reports
• Analyze the results in Metric or English units
• Color code & filter results by category
Work Permits
According to NFPA 70E guidelines, permits are required when performing work on energized equipment.
Work permits include shock hazard and arc flash analysis results. The work permit needs to be generated
or individual bus arc flash results in addition to other pertinent information.
Data Sheets
The Data Sheet is an enhanced version of the arc flash analysis report. It gives detailed description of
what selections were made in the Short Circuit study case and how the bus results were obtained. Data
sheets can be customized to communicate arc flash study parameters.
Features
• Consider motor fault current decay during the arc flash calculation
• Automatically exclude small motor contributions entirely from the simulation
• Automatically identify and exclude transformers with relatively low voltage and kVA
• Assign a hazard category to these types of equipments automatically based on fault current ranges
Features
• Global definition of arc flash analysis data eliminates the need to specify this information in each
bus
• Global definition of working distance, bus gaps, approach boundaries, and voltage-rated glove
classes
• Specify Arc Flash Analysis Data based on IEEE 1584 2002 or user-defined values
• Globally select Shock Hazard Analysis Data based on NFPA 70E 2004, 2009 or user-defined
settings
• Globally change the class settings given by ASTM D 120-02a Standard for voltage-rated
protective gloves
• Updates can be made globally without having to modify each bus editor individually
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
4
3. ETAP Star
ETAP 7.0 includes an extensive list of enhancements for the ETAP Star module. Using these new user-
oriented capabilities, the process of design and evaluation of protective device coordination is
significantly faster and easier. Among them is the Star Sequence-of-Operation with new short circuit fault
types: Line-to-Line, Line-to-Line-to-Ground in addition to 3-phase and Line-to-Ground.
Sequence of Operation
Star Sequence-of-Operation evaluates, verifies, and confirms the operation and selectivity of the
protective devices for various types of faults for any location directly from the one-line diagram and via
normalized TCC curve views. Sequence-of-Operation provides a system wide solution for an accurate and
realistic operating time and state of protective devices, such as relay, fuse, circuit breaker, trip devices,
contactor, etc. The operation time is calculated for each protective device based on its settings, time
current characteristic, and interlocks for a specified fault location and type. ETAP 7.0 enhances this
invaluable tool by including Line-to-Line and Line-to-Line-to-Ground Drag-and-Drop Faults in addition
to 3-Phase and Line-to-Ground Faults.
Features
• Partial Differential Relay Modeling
• Ring-Bus Protection
• Multiple Source Systems Protection
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
5
4. Data Exchange
ETAP Data Exchange is used to import, export, and synchronize data between external data sources and
ETAP. DataX provides many utilities including:
DataX includes several new conversion programs that allow for conversion of third party electrical power
system databases to ETAP. The conversion program will automatically generate a multi-layered graphical
one-line diagram. A list of available conversion programs are available upon request.
The SPEL XML file contains the electrical data for equipment and connectivity information in the SPEL
project. The ETAP data exchange interface uses information available in SPEL to add, modify, and delete
elements. The interface not only auto creates one-line diagrams, it also facilitates multiple data transfers
(synchronization) between ETAP and SPEL. As a result, data in ETAP and SPEL are kept consistent
without going through the time-consuming manual process of recording additions and modifications in
both systems.
The ETAP-SPEL cable library data synchronization is bridged by a Microsoft Access database. Users can
import or export ETAP project cable library data into or from the Microsoft Access database using the
ETAP Lib Utility. Through the SPEL Lib Utility, users can also export or import cable library data into or
from the Microsoft Access database.
5. Load Analyzer
The Load Analyzer module is designed as a generalized load list to report load schedules for power
system components such as switchgear, MCC, transformers, cables, lines, panels, etc. Different reports
provide informative data regarding all loads connected downstream to the equipment. Load Analyzer is
an invaluable tool during the design / planning phase as well as analyzing existing electrical systems
because running system studies like load flow analysis may not be possible due to incomplete one-line
diagram or data.
6. Enhanced Elements
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
7
7. Enhanced Modules
Short Circuit
ETAP Short-Circuit module has enhanced duty calculations for generator circuit breakers per the latest
version of IEEE Std C37.013, “IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on
a Symmetrical Current Basis”. The generators are modeled by the sub-transient dynamic model to
represent AC and DC decay of short-circuit contributions from the generator. It calculates both system-
source and generator-source short-circuit currents and considers no-load, lagging PF load, and leading-PF
load for pre-fault conditions.
ETAP provides several options for multiplication factor (MF) for high-voltage circuit breaker and bus
momentary duty calculations. The options include MF calculated based on system X/R, fixed values at
1.6/2.6, or use of 1.6/2.6 as minimum values. These options allow the user to obtain accurate results as
well as to ensure conservativeness in short-circuit calculations.
Features
• Generator sub-transient model to represent AC and DC decays
• Generator-source and system-source short-circuit currents with no-load, leading PF, and Lagging
PF
• Symmetrical, asymmetrical, and peak kA at 1/2 cycle
• Symmetrical, asymmetrical, peak, and DC kA as well as degree of asymmetry at generator CB
contact parting time
Transient Stability
The latest edition of ETAP provides the following new capabilities to transient stability, making it the
most powerful stability program in the industry hands-down.
Features
• State-of-the art Governor-Turbine models used in the majority of large industrial power systems
• Isochronous / Droop switching capability for Gas Governor-Turbine with GE Mark IV, V & VI
model (GGOV3)
• Solar Gas Governor-Turbine with DLN combustion system model (SGOV1)
• Westinghouse Gas Governor-Turbine with jump rate limiter model (WGOV1)
• Ability to simulate the new Governor-Turbine dynamics including manufacturer unpublished
details
• Governor-Turbine models are fully verified and validated by field measurements / benchmark
tests
• Higher order integration solution method for synchronous machine swing equation
• Synchronous machine typical data
Harmonics
The Newton-Raphson method for initial load flow provides an improved convergence for larger systems
with small impedances.
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
8
8. System Requirements
PC Configuration Requirements
• USB port (if stand-alone licensing required)
• Ethernet port w/network access (if network licensing required)
• DVD Drive
• 5 to 80 GB hard disk space (based on project size, number of buses)
• 19" monitors recommended (dual monitors highly recommended)
• Minimum display resolution -1024x768
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
9
Library Additions
The following protective device manufacturers and models are added to the library.
MFR Model
ABB 121PM20, 121PM40, 121PM50, 121PM63, 145PM20,
HVCB 145PM40, 145PM50, 145PM63, 169PM20, 169PM40
Toshiba VK-10M25A2,VK-10M40A, VK-10M40AH, VK-
10M50, VK-10P25A2, VK-10P40A, VK-10P40AH, VK-
10P50, VK-10Q40, VK-10Q40H, VK-10Q50, VK-20J13,
VK-6M32A, VK-6M40A, VK-6M50, VK-6P32A , VK-
6P40A, VK-6P50, VK-6Q50, VK-8M40A, VK-8P40A,
VK-8Q40, VY-20M25A, VY-20P25A, VY-30M25A,
VY-30P25A
RELAY ABB 50B, COQ, KAB, IRC, IRD, IRP, SSC-T, REX 521,
Areva CAG17, CAG37, CTU12, CTU22, CTU32, CTU62
BBC ISM2, ISM 21
Cooper iDP-210
Cutler-Hammer IQ-1000 II, FP-4000, FP-5000
Eaton MP4000
Federal Pioneer GFR
GE Multlin MIF II, MIF-P, IAC-99AY, T35, MM300, MIF-P, MIF-N,
B90
Merlin Gerin SEPAM 20, SEPAM 40
Mitsubishi CMP2 - A02D2, COC4-A02D1
P&B Engineering Advanced Feedervision II, Advanced Motorvision II,
Feedervision II, Microfeeder Plus, Microvision Plus,
Motorvision II, MPC 2000+, MPC 2000D, MPR 10, MPR
2500, MPR 3E5, MPR 3E5 (Vision 100), PBSJ 120, PBSJ
140C (SPCJ 4D29), PBSJ 3E5 N11
Reyrolle Rho 3
S&C Electric Co. ZSD
Schweitzer Rho 3, 387A, 751A, 710, 487B, 487E, 9995A, 787,
MGFR-1-ZB, MGFR-2-ZB, MGFR-20-ZB, MGFR-200-
ZB, MGFR-1200-ZB, MGFR-SE-ZB, 587Z
Siemens 3UF7
Square D SEPAM SERIES 40, SEPAM SERIES 80
Startco Engineering MPU-16A, SE-701, MPS, MPU-32, FPU-16, FPU-32, SE-
Ltd. 134C
Thytronic DIG 5200
TMT&D CAC1-A01D2, COC1-A01D1
Vamp Vamp 230, Vamp, 245, VAMP 255, VAMP 257
Westinghouse IT, ITH, ITH-T
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
10
Fuse Bussman LPS-RK_SPI (12/00)
GEC CC, CCP, CF, CFP, CIA, CIS, CLM, CM, CMF
Gould Shawmut A25Z-2, CRN, CRS, NRN, NRS
Hi-Tech Fuses Inc Trans-Guard OS, Trans-Guard OS Shorty
Littelfuse CCMR, KLLU
Reproel FH-15, FH-17, FH-18, FH-25, FH-27, FH-28, FH-35, FH-
37, FH-38, FH-45, FH-47, FH-48, FH-55, FH-57, FH-S40,
FH-S50
MFR Model
LVCB Cutler-Hammer MH, MS
MCP General Electric TEC (02/04), TFC (03/97), TJC (03/97), TKC (03/97),
LVSST Square D ET1.0 (MG), ET1.0 (MJ), ET1.0 (PG), ET1.0 (PK), ET1.0
(PL), ET1.0 (RG), ET1.0 (RJ), ET1.0 (RK), ET1.0 (RL)
Terasaki AGR-L (LT Curve), AGR-R (LT Curve)
MFR Model
Electronic Cooper VFI (5kV), VFI (15kV), VFI (25kV), VFI (35kV)
Reclosers
MFR Model
Overload General Electric CR124
Heater
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2009 BY OPERATION TECHNOLOGY, INC.
11
ETAP 6.0.0
March 2008
The OTI Development Team is pleased to provide you with the enclosed ETAP 6.0.0 release. ETAP 6.0.0
is a complete program and does not require any previous ETAP installation.
ETAP 6.0.0 is a major release that delivers new capabilities to significantly enhance your power system
analysis experience while making the process faster and easier. This version is enhanced with easy to use
features that allow you to easily create and organize a one-line diagram with one click operations. The
new enhancements and analysis modules are still developed with mathematical precision using our
Quality Assured Verification and Validation Procedure.
The first time you run ETAP 6.0.0, you will need to enter the 36-Digit CD Activation Code as provided
on the ETAP 6.0.0 installation CD.
For more information on this new release, please take a few moments to review the information below.
New Features
Graphical Undo & Redo Enhanced Modules
Graphical Alignment Tools Load Flow
Group Rotation Arc Flash Analysis
Element Mirroring & Polarity Transient Stability
Coloring Based on Voltage Level Star TCC
Voltage Propagation (Single-Phase) Star Sequence of Operation
User-Defined Symbol Text Motor Starting & Acceleration
Ground Grid System
New Analysis Modules GIS Map
Cable Ampacity & Sizing - BS 7671 Data Exchange
Single Phase Duty Calculation
Panel Systems Duty Calculation New Libraries
Reclosers
New Elements Differential Relays
Reclosers Maintenance Mode Setting
Differential Relays
In-Line Overload Relay New Tools
Motor-Generator Set Study Result Comparator
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
1
1. One Line Diagram
Undo/Redo
ETAP One-Line Diagram now remembers unlimited graphical actions with the help of graphical
undo/redo feature also widely known as the Oops command. You can now backtrack single or multiple
steps to correct mistakes or reverse the effect of the undo command by using redo.
Features
• Unlimited Undo / Redo Actions within Individual Presentations
• Undo/Redo Actions within composite networks
• Undo/Redo show/hide protective devices
• Undo/Redo movement of any device
• Undo/Redo moving, adding or deleting a connection
• Standard Keyboard Shortcuts (Undo - CTRL+Z, Redo - CTRL+Y)
Features
• Straight & Space Alignment
• Horizontal Alignment (Middle, Top, Bottom)
• Vertical Alignment (Left, Center, Right)
• Distribute Spacing (Horizontal, Vertical)
Features
• Up to 20 user-defined voltage levels and colors
• Instantly create or switch between multiple color schemes using theme templates
• Set different themes for individual one-line diagrams
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
2
Relay & Current Transformer Mirroring
Group Rotation
• Rotate selected elements or single elements by 90, -90 180 degrees.
Voltage Propagation
In addition to the existing voltage propagation on three phase networks, the voltage propagation is now
capable of detecting single-phase connections and propagating voltage through single-phase two wire and
three wire systems as well as panel systems.
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
3
2. Enhanced Modules
Load Flow
The Load Flow Result Analyzer is a time saving tool that allows you to compare and analyze different
reports coming from different projects, within the same directory, in a single display. You can compare
the results of general information about the project or more specific information such as the results
contained from buses, branches, loads or sources in a load flow study.
Features
• Compare and View Multiple Load Flow Results in One View
• Analyze and Compare Reports from Multiple Projects
• Create a base line report and quickly identify deviations for all cases
• View Multiple Bus, Branch, Loads and Source Results at a glance
• Advanced Alert and Warning feature identifies and highlights components that are overstressed
and need your attention
• Quickly find components on the one-line diagram from the analyzer view
• Export summary view into MS Excel for maximum data flexibility
Short Circuit
The highly capable Short Circuit Analysis is more diverse and, in addition to ANSI/IEEE and IEC
methods for 3-Phase short circuit current calculation, can now perform 1-Phase device duty short circuit
study. ANSI and IEC 60909 Standards are available for calculating short circuit current for a main panel,
sub-panel, UPS and phase adapter. Single phase device duty calculation compares the calculated fault
current for evaluation of protective devices and generates critical and marginal alerts based on user-
defined limits. Loads and motors, even if they have protective devices, monitoring devices and a cable,
do not need their own buses/nodes. And yes, load terminal voltages and voltage drops are calculated and
displayed on the one-line diagrams. ETAP 6.0 takes this functionality to the next level by not only
calculating but also displaying and reporting the short circuit current at all load terminals that have
equipment cables. The benefits include is faster calculation time, de-cluttered one-line diagram and more
concise reporting.
Features
• Include all panel subsystems in device duty calculations
• Include all UPS systems in device duty calculations
• Include all Single phase systems in device duty calculations
• Calculate the load terminal fault current for Motor, MOV, Static Load and Capacitor
• IEC compound excitation modeling for Ikmin based on IEC 60909-0 2000.
• Enhanced display options to allow display of 3-Phase and 1-Phase SC results from the same study
• Enhanced modeling of synchronous machines impedance values like R2/X2 and R0/X0
• Positive tolerance adjustment for calculating minimum short-circuit currents
• Enhanced detection of 1-Phase connections for short-circuit load terminal faults
• Calculate device short-circuit duty for ANSI/IEC reclosers
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
4
Arc Flash
ETAP Arc Flash Analysis estimates the arc flash incident energy under a bolted 3-phase short circuit fault
and determines the flash protective boundary to live parts for shock protection. Design safer power
systems by insuring compliance with OSHA 29 CFR 1910.132(d) 1990, NFPA 70E-2004, and IEEE
1584-2002 Standards. Arc Flash now provides the flexibility to calculate arc flash results at load
terminals that are fed via equipment cables.
Features
• Motor / Load Terminal Arc Fault Calculation
• Maintenance Mode Switch for Low Voltage Solid State Trip device
• Relay actions (79, 87, 49, 27, 59, 67) in arc fault calculation
• Enhanced search capabilities for source protective devices
• New arc flash label templates (English, Spanish & Portuguese) with user-defined text fields
• Enhanced user-defined fixed fault clearing time
ETAP STAR
ETAP 6.0 includes an extensive list of enhancements for the ETAP Star module. Using these new user-
oriented capabilities, the process of design and evaluation of protective device coordination is
significantly faster and easier. Among them is the Star Sequence-of-Operation with enhanced handling of
protective devices such as differential relay (87), directional relay (67) and voltage relay (27).
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
5
Transient Stability
The latest edition of ETAP provides the following new capabilities to transient stability making it the
most powerful stability program in the industry hands-down:
Features
• Initial Load Flow using Newton Raphson Method in addition to Accelerated Gauss Siedel
• Faster Calculation Time by providing option to skip tabulated plots
• New transient event - Line to Ground Fault
• New GE Turbine-Governor Model (GGOV3)
• New Exciter IEEE ST4B
• Auto Sync-Check Action
• Enhanced Synchronous Machine Saturation Factor
• Enhanced Synchronous Machine Salient-Pole Model
Installation Type
• Trenches
• Embedded Direct
• Brackets
• Cleats
• Ladder
• Open and Clipped Direct
• Building Voids
• Trunking
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
6
Motor Starting
• Faster Calculation Time by providing option to skip tabulated plots
Data Exchange
• Enhanced user interface for data synchronization
• Added Sequence (.seq) and Dynamic (.dyr) data with Raw data import
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
7
3. New and Enhanced Elements
Recloser
• Hydraulic
• Electronic with Static Controller
• Electronic with Microprocessor Controller
• Device Coordination (Star) - Star SQOP
• ANSI/IEC Short-Circuit Duty Evaluation
• Overload alerts in Load Flow Analysis
• Comprehensive library of old and new reclosers / controllers
• Detailed modeling of reclosing device
Differential Relay
• Partial-Bus, Total Bus, Transformer, Line & Cable
• Percentage and High Impedance Types
• Device Coordination (Star) - Star SQOP
• Considered in Arc Flash Analysis
• Library of differential relays
• Please note that checker functions for multifunction differential relays may show the relay as
unchecked if you remove other functions like overload or overcurrent.
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
8
Library Additions
The following protective device manufacturers and models are added to the library.
MFR Model
Electronic ABB OVR-1 Series Rs14x-RS28x, OVR-3 Series R111x-
Reclosers R378x, VR-3S Series V115x-V378x
Cooper NOVA1-15 400-800A, NOVA1-27 400-800A, NOVA15,
NOVA27, NOVA38, NOVA-TS-15 400-800A, NOVA-
TS-27 400-800A, PWE, PWVE, RXE, VSA12, VSA12B,
VSA16, VSA20, VSA20A, VSO12, VSO16, VWE,
VWVE27, VWVE38X, WE, WVE27, VWVE38X, WE,
WVE27, WVE38X, VXE15, VXE27
FKI Switchgear GVR15, GVR27, GVR38
G&W Electric Viper-G 15.5kV – 38kV, Viper-S 15.5kV-38kV, Viper-ST
15.5kV-38kV
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
9
MFR Model
Microprocessor ABB ICD
Cooper Form 4C, Form 5, Form 5 Triple-Single, Form 6, Form 6
Triple-Single, FXA, FXA/FXB, NOVA1 Control, VXE
Control
FKI Switchgear Panacea (SEL-351P)
Joslyn 351J, Faultmaster 2500, PowerMAX 100
Nu-Lec ADVC
Schweitzer 351R, 651R
Static Cooper Form 3A, Form 3A (RE, RVE, RXE), Form 3A (Type
VSA), Form 3A (Type VSO), Form 3A (W-group)
RELAY ABB REA 101, REM543, SC, SC-1, REF 545, REL 561
Allen Bradley SMP1, SMP3, 825-P
Areva P-132
GE Multilin G650, C60, F650, 735/737
P&B Engineering MREF
Schweitzer 710 (R100), 701 (R106-R113)
Square D Sepam Series 20, GC-200
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
10
MFR Model
LVCB Cutler-Hammer MDS-Cxx
Federal Pioneer CE-B, CE-E, CE-E4, CE-H, CE-N, CJM-E, CJM-H, CJM-
N, CK-E, CK-H, CK-N, CMH, FKD, FKG, HEW, HEZ,
TH1, TH4, TH8, CJL-E, CJL-N, CJL-H
Merlin Gerin C60N Series, C60H, C60L
Square-D QB, QD, QG, QJ, QE-VH
Nikko SK202, SK203, SK204
Siemens HEG, NEG
TM Federal Pioneer CMH, CJM, CE-B, CE-E, CE-E4, CE-H, CE-N, FK-D,
FK-G, HEW, HEZ, TH1, TH4, TH8, CJL-E, CJL-N, CJL-
H
Merlin Gerin C60N C-Curve, C60N/H D-Curve, C60N/H/L C-Curve,
C60N/H/L B-Curve
Nikko SK225
Square-D QB (50 Hz) (60Hz), QD (50 Hz) (60Hz), QG (50 Hz)
(60Hz), QJ (50 Hz) (60Hz)
Siemens HEG, NEG
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
11
ETAP 5.5.6
March 2007
The OTI Development Team is pleased to provide you with the enclosed ETAP 5.5.6 release. ETAP 5.5.6
is a complete program and does not require any previous ETAP installation.
This point release is the latest in the ETAP 5.5 series and includes several enhancements and
modifications from the earlier 5.5.5 release. We recommend that you utilize this latest release in order
to take advantage of the new features and capabilities. Note that network users must also update their
ETAP License Manager. The updated License Manager is compatible with earlier releases.
ETAP 5.5.6 will utilize the same 36-Digit Key Code as provided with the ETAP 5.5.5 release.
For more information on this new release, please take a few moments to review the information below.
1. Library Additions
The following protective device manufacturers and models are added to the library.
MFR Model
RELAY Startco Engineering SE-320, 325
ABB REJ 525, REF 610, REM 610
GE Multilin MM3, TMC14B, IAC-60T, IAC-80T, IAC-90T
VA TECH Argus 1, 2, 4, 6
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
1
2. Protective Device Library Information Exporting Tool
An ETAP tool is added to this version to extract library information for all protective devices in an
ETAP project. The extracted information is exported to a Microsoft Excel file which is placed in the
ETAP project directory. The extracted information includes device ID, Type, Manufacturer, Model,
etc. This handy tool can be used to easily determine protective devices that utilize specific device
libraries.
Once you install ETAP 5.5.6, a tool named “PD Library Export” will automatically be added to the
ETAP Tools menu. To use this tool, open ETAP Tools menu and click on the PD Library Export
tool. A Microsoft Excel file will be generated in the ETAP project directory with a file name
“PDLibExport-XXX.xls”, where XXX will be replaced by the ETAP project file name.
You can change the Excel filename from the ETAPS.INI file. To change the filename, open the
ETAPS.INI file from your application directory (by default installation C:\ETAP 556) and locate the
statement for the tool in the [AppVariables] section, which should be similar to the following.
Change the blue section “PDLibExport” to the name you prefer. Note that if the ETAPS.INI file is
not in the application directory then use the ETAPS.INI located in your windows directory.
3. Arc Flash
In ETAP 5.5.5, under a set of very special conditions (Low Voltage Solid State Trip LVSST with
Short-Time I2t delay band set to “IN” while the library is set to zero), the calculated fault clearing
time is different from the actual clearing time if the Source Protective Device is one of the libraries
listed below. ETAP 5.5.6 has been enhanced in this version to handle these special conditions.
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRUGHT © 2007 BY OPERATION TECHNOLOGY, INC.
2
ETAP 5.5.5
December 20, 2006
The OTI Development Team is pleased to provide you with the enclosed ETAP 5.5.5 release. ETAP 5.5.5 is a
complete program and does not require any previous ETAP installation.
This point release is the latest in the ETAP 5.5 series and includes several enhancements and modifications
from the earlier 5.5.0 release. We recommend that you utilize this latest release in order to take advantage of
the new features and capabilities. Note that network users must also update their ETAP License Manager.
The updated License Manager is compatible with earlier releases.
ETAP 5.5.5 will utilize the same 36-Digit Key Code as provided with the ETAP 5.5.0 release.
ETAP 5.5.5 allows you to explore the ETAP Real-Time capabilities including Power System Monitoring &
Simulation (PSMS), Energy Management System (EMS), and Intelligent Load Shedding (ILS). A sample
system is provided along with the ETAP Real-Time installation which allows you to take ETAP online and
experience the power of ETAP Real-Time enterprise. For more information, please contact [email protected] or
visit our web site at etap.com.
For more information on this new release, please take a few moments to review the information below.
1. Library
• Cable library
Added Olex Cable library
• Fuse library
Added the following models:
MFR Model
Bussmann OEF, OHF, OLG, OEG, OHG, NH Series
Cooper Bay-O-Net (High Ampere), ELSP, X-Limiter
Cutler-Hammer CLS (07/03), CLE (0703)
Little Fuse FLSR (01/03)
Siemens 3NA Series
Gould Shawmut (Ferraz) A50P
MFR Model
Square-D HD, HG, HJ, HL, JD, JG, JJ, JL, GJL
Cutler-Hammer PA, T4 and T5 Series, HFA, HMDL-DC, ELFD, ELFDC, ELHFD, ELHJD,
ELHKD, ELJD, ELJDC, ELKD, ELKDC
ABB S500 Series
Westinghouse PA, T4 and T5 Series, HFA
MFR Model
ABB SACE PR221, SACE PR121, SACE PR122, SACE PR123
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC. AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRIGHT © 2006 BY OPERATION TECHNOLOGY, INC.
1
• Thermal Magnetic Circuit-Breaker library
Added the following models:
MFR Model
ABB T4, T5 Series
Federal Pacific HEF, NE, NEF Series
Cutler-Hammer HMDL-DC, NH, NS, HFA, PA
Square-D Powerpact H and J frame Series, GJL Series
• Relay library
Added the following models:
MFR Model
ABB REF 543, REF 541,
SPAJ 110C, SPAJ 111C, SPAJ 115C, SPAJ 135C, SPAJ 141C, SPAJ 142C,
SPAJ 144C, RAMDE, REM 545, SPAD 346C, SPAJ 1B1 J3
Schweitzer 311L
AREVA P441
VAMP VAMP 130, VAMP 140, VAMP 265
Beckwith Electric M-3425
Siemens 7UM62
GE Multilin G30
Orion Italia IPR-A, SMPR
Startco Engineering SE 105, SE 135
2. Localization
• Enhanced the program to handle period (.) or comma (,) decimal separators for float numbers.
3. GIS
• Upgraded ETAP GIS Map to interface with ArcGIS Version 9.1
• Enhanced ETAP GIS interface to work with ArcGIS run time engine
4. Short-Circuit
• For ANSI Device Duty of generator circuit-breaker, an automatic search is added to determine a
single path between a generator and the generator circuit-breaker. For a generator and the
associated circuit-breaker with a single path, the circuit-breaker duty is calculated by the system-
only contribution or generator-only contribution.
• Added a new preference option to allow the user to decide if machine FLA to be included in duty
calculations when the option of “Based on Maximum Through Fault Current” is selected for
machine protective device duty.
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC. AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRIGHT © 2006 BY OPERATION TECHNOLOGY, INC.
2
The ETAP LM service may not start automatically after rebooting the ETAP LM server if virtual machine
software exists on the same machine. If virtual machine software is present on LM server machine, it is
recommended to verify that the 'ETAP Lic Mgr' service is running or start the service manually under
System Services.
THIS DOCUMENT IS CONFIDENTIAL AND PROPRIETARY TO OPERATION TECHNOLOGY, INC. AND MAY NOT BE REPRODUCED PUBLISHED OR DISCLOSED TO OTHERS
WITHOUT THE WRITTEN AUTHORIZATION OF OPERATION TECHNOLOGY, INC. COPYRIGHT © 2006 BY OPERATION TECHNOLOGY, INC.
3
ETAP 5.5.0
June 19, 2006
ETAP 5.5.0 is a major release that delivers new capabilities to significantly enhance
your power system analysis experience while making the process faster and easier.
Contributing to this objective includes the addition of new features to graphically
animate the system response for Protective Device Operation, Control System Logic
Sequence, and Dynamic Response Operation with more flexible configuration options
and greater display.
The ETAP WTG module comes to market with proven utility. It is currently being used for real-time
monitoring of power exchange between wind turbines and the power grid at one of the largest wind farms
in the United States.
Features
• Ability to model unlimited wind turbine generators individually, or in groups
• Detailed modeling of turbine dynamics including aerodynamics & power coefficients
• Model doubly-fed induction generators with pitch & converter controller characteristics
• Simulate transient wind conditions with ramp, gust, & noise disturbances & calculate dynamic impact
on wind machines
• Create multiple wind categories for predictive “what if” studies & scenarios
• Perform transient stability analysis with individual or zone-based disturbances
• Run one instance or continuous steady-state calculations in analysis mode
New Capabilities
• Test relays & import the test results into ETAP Star
• Test, simulate, & calibrate overcurrent, differential, & distance relays
• Fully integrated interface with ETAP Star & Short-Circuit modules
• Compare actual steady-state & transient responses of relays with published manufacturer specifications
• Playback transient waveforms for evaluation
• Archive relay test data for historical reference & retrieval
• Customizable test reports
ETAP 5.5 includes an extensive list of enhancements for the ETAP Star module. Using these new user-
oriented capabilities, the process of design and evaluation of protective device coordination is
significantly faster and easier. Among them is the Star Sequence-of-Operation with enhanced graphical
animation of the operation of protective devices on the one-line diagram.
Graphical Animation of Protective Device Operation
New Features
• Virtual animation of sequence-of-operation playback on the one-line diagram
• Normalized TCC plots with shifted curves based on fault contributions
• User-definable curves & fault arrows
• Batch print TCC plots & diagrams for various paper sizes
• Automated color sequencing of TCC curves
• Enhanced print options & functionality
• Flexible user-definable display & plot options
• Star library Merge Manager
• Intelligent alert view for troubleshooting
• Enhanced relay library interface
• Acceleration curve for overload relays
• Transformer inrush curve
• Graphical TCC curve tracker with cross lines
• Expanded verified & validated device library
• New Relay Test-Set Interface for evaluating steady-state & transient relay response
Tag-Link Element
The new Tag-Link element brings measurements from metering systems, PLC, and SCADA into ETAP
using a graphic element in the one-line diagram.
New Features
• New Programmable Logic Editor (PLE) for user-defined control commands
• User-defined macro-based logic without hardware installation
• System optimization & automation
• Automatic generation control
• Security control
• Intelligent feeder & demand management
• Peak shaving
• Cost allocation
• Operator training simulator
• Supervisory & advisory control
• Intelligent inhibition & permissive control
Special handling techniques have been incorporated for islanded systems and power exchange between
subsystems. The user interface has been enhanced to enable logic switching and/or load priority schedules
without interrupting operations or re-programming devices. Operators can now easily switch schedules
based on operating requirements such as summer and winter demands. In addition, specific monitor
windows have been added to allow one view to provide a complete status of the system. The Priority
Schedule editor has been enhanced to easily define factors that specify significance of individual loads,
feeders, etc.
New Capabilities
• Programmable Logic Editor to add user-defined control logics (simple & complex) such as limits,
interlocks, permissions, inhibitions, etc.
• New user-friendly editors to define associations & interlocks
• Multiple priority schedules with user-defined sensitivity factors
• User-definable group numbers for optimal breaker selection
• Simultaneous display of the real-time operation & local simulation results
• Easily simulate & validate load shedding commands
• OPC alarm & notification
• Monitor & respond automatically to electrical & non-electrical disturbances
• New user-friendly editors for setting up ILS
• View & print customizable full-color reports
• Monitor “Live” load shedding operation in XML on web page
• Full security access control
Arc Flash
Arc Flash now provides the flexibility to print customizable labels on either Avery® labels or high-end
Brady® label printers using new label templates and printing capabilities.
New Features
• Capability to limit incident energy based on maximum Fault Clearing Time (FCT)
• Automatic application of calculated & user-defined FCT simultaneously
• Algorithm for automatic detection of the primary protective device in complex looped networks
• Export results to Excel spreadsheets for interface with third party software & label printers
• New user-interface for defining PPE requirements for each risk category
• Coordinate protective devices using the arc flash incident energy plotted on the TCCs
• New arc flash label templates with user-defined text fields
• New incident energy summary reports
Short-Circuit Analysis
For both ANSI and IEC standards, determine short circuit duty of tie circuit breakers based on the
“Maximum Through Fault Current.”
Panel Systems
The Panel Systems module, an intuitive graphical user interface for the design and analysis of low voltage
distribution systems, can now export panel data and schedules to third party CAD systems and
Microsoft® Excel. The new features include:
• User-definable ground wire fields per branch circuit
• User-definable conduit size field per branch circuit
• Export panel schedules to Excel worksheets
• Five new panel schedule & report templates
• Export panel report & schedule to CAD systems
Harmonic Analysis
A new option has been added that allows you to use long-line model for transmission lines and cables.
Data Exchange
DataX represents a rich set of customizable ETAP interfaces that can be used to bridge gaps between
ETAP and other databases.
DataX - Base
The new import tools added to the base package allow you to:
• Import IEEE format files
• Import RAW data files
• Import & export configurations
• Import ground grids from AutoCAD
DataX - Microsoft® Access & Excel
This new module provides the ability to import and synchronize data from Microsoft Excel and Microsoft
Access into ETAP.
• Import data from a Microsoft Access table
• Import data from Microsoft Excel worksheets
• Customize data mapping through the graphical user interface
• Automatic data range checking with library data substitution
• Automatic one-line diagram generation
• Intelligent data validation & consistency checking
• Automatic modify & delete actions for existing elements
• View modifications & accept or reject actions
SmartPlant® Interface
The ETAP-SmartPlant interface has been enhanced to allow modification of existing project files from
SmartPlant. Major enhancements include:
• Automatic add, modify, & delete actions of elements
• Enhanced one-line diagram generation
• Enhanced element mapping
e-DPP® Interface
The ETAP e-DPP interface now provides:
• Automatic one-line diagram generation
• Enhanced element mapping
• Automatic add, modify, & delete actions of elements
GIS Map
Modify the display of load flow and short circuit results on GIS maps using the new ETAP display
options.
Get-Set Defaults
The new capability to set and obtain parameters to-and-from element defaults enables parameters to be
passed from one element to another.
ETAP Preferences
Now you can apply new preference settings directly from ETAP. Adjust settings in the INI file to
customize your ETAP application behavior. These settings are categorized alphabetically or based on an
analysis module.
Control System Diagram
The highly capable CSD module streamlines the modeling and simulation of control systems by using
a unique state-dependent process that allows you to easily evaluate control logic of new and existing
systems. The sequence-of-operation animates the operation of control systems with associated interlocks
and controlled devices. This includes elements such as control relays, solenoids, controlled contacts,
multi-sequence contacts, push buttons, switches, and actuators. You can select from a large library of
control devices to quickly determine pickup and dropout voltages, losses and current flows at various
time instances including inrush current. As control devices go through the time sequence and various
states, the program provides marginal and critical alerts.
New Features
• Graphical animation of complex control logic with or without voltage drop calculation
• Include time-dependent loads of control systems in battery discharge & sizing calculation
• Operator initiated control actions and/or auto-run mode
• Display and alert overloading as well as pickup/dropout voltage violations
• Flexible device modeling with user-defined duty cycle or actual inrush/burden rating
• Validate the voltage requirements of controlling devices
• Generate automatic alerts for pickup & dropout voltage
• View detailed operating states of the devices with the new Event Viewer
Cable Sizing
In addition to the existing ampacity and voltage drop requirements, a new capability has been
added to size cables based on short circuit current.
Transmission Line
ETAP 5.5 determines sag and tension for transmission lines on towers with different elevations.
Automatic alerts notify when power interchange exceeds derated ampacity of the line.
Transient Stability
The Transient Stability module has been upgraded to present a graphically animated display of the system
dynamic response after disturbances. The program is also enhanced for faster calculation speed and plot
generations. You can simulate system disturbances and events while performing load shedding, fast bus
transfer, critical clearing time, generator start-up studies, and the acceleration or re-acceleration of
motors, etc.
New Features
• New sequence-of-operation with interactive time-slider & action list
• New wind turbine generator dynamic models
• New action commands for wind gust, ramp, & noise disturbances
• Apply voltage limits to MOV open & close stages
New Features
• Calculate the most cost-effective installation locations & bank size
• Calculate return on investment for the entire planning period
• Consider voltage support & power factor correction objectives
• Generate reports & plots of capacitor operating profit
• Handle unlimited network configurations
• Options to constrain installation locations with user-defined parameters
• Option to constrain the maximum number of capacitors installed at any location
• Use both individual & global constraints
• Utilize individual source or global energy costs
• Evaluate the capacitor installation for various system loadings
Configuration Manager
The Configuration Manager provides a tabular view of individual device status and allows you to view,
control, and manage the status of all elements from one editor. This dynamic new feature adds increased
flexibility to change, track changes, and compare status of devices. For example, intelligent filtering
isolates specific open protective devices making it easy to locate on the one-line diagram. Additional
filtering exposes differences between configurations in a fraction of the time normally associated with
one-line diagram monitoring.
New Features
• Manage & view configuration status of devices at a glance
• Identify differences between configurations for better visual understanding
• Option to filter & display specific configurations & device types
• Options to customize display status
• Directly modify the status of multiple devices
• Create, copy, delete, & rename commands
• Export configurations to Microsoft Access tables for further queries & reporting
Configuration Checking
In addition to the In addition to the properties (elements in the project) and library data, you now can
check and validate configuration status of elements.
Theme Manager
The Theme Manager allows you to create and recall templates for the graphic display of elements,
connectors, annotations, results, alerts, and background colors. You can graphically distinguish phase
connections (such as A, C, D, 1-phase, 2-phase, 3-phase, 2W, 3W, 4W, etc.) by changing the connector
style and colors. This highly versatile interface permits customization at nearly every level. This includes
the flexibility to select from existing templates, Microsoft Windows environment, or personalized themes.
A significant advantage of the Theme Manager is that unlimited project-independent custom styles may
be stored on a computer and are readily available when you switch from one ETAP project to another.
New Features
• Instantly create or switch between multiple color schemes using theme templates
• Pick a background color for the best contrast when viewing one-lines, performing system studies, or
real-time monitoring
• Set different themes for individual one-line diagrams
• Flexible coloring for AC & DC elements, annotations, & composite networks
• Assign highly visible colors for alerts, alarms, & warnings
• Easily differentiate between 1-phase, 2-phase, & 3-phase systems
• Modify the element, grid, & background colors for specific presentations
• Easily set colors based on voltage levels
License Administrator & Wizard
Maintain optimal productivity and receive the greatest value from ETAP resources by monitoring and
administering access to your ETAP license. This new tool provides an at-a-glance view of all the
computers and users online with ETAP. It even keeps track of how long they’ve been logged online. The
License Wizard can switch access to different ETAP License Managers. Productivity bottlenecks can be
avoided by scheduling user access when demand exceeds the number of
• Identify all users logged onto ETAP
• Minimize accessibility conflicts
• Manage ETAP licenses via License Wizard
Output Reports
Viewing output reports and plots is now even easier. The new Find feature allows you to locate specific
information fast. Simply select an element type from a listing of element IDs, then choose the ID you
wish to review and search the report for occurrences of the selected ID. Examine the report electronically
in the viewer or save the data in a format that can be opened by a spreadsheet program. Experience faster
operation and easier access to your report data. Other enhancements include:
• Find elements or text
• Reports can be exported in five common spreadsheet & word processing formats
Text Box
• Add text in user-defined areas on one-line & control system diagrams
• Select the font, size, & color of text
• Modify the shape & opacity of a text box
• Edit appearance of text boxes for print output or electronic presentations
• Default text box settings
With the “ETAP Advantage” option, you receive the following additional documentation and services:
1. Verification & Validation Certification Letter which states that ETAP is verified and validated
per the requirements of ISO 9001:2000, Title 10 CFR 50, Appendix B, Title 10 CFR Part 21,
ANSI/ASME N45.2, ASME NQA-1, ANSI/IEEE Std 730.1, CAN/CSA-Q 396.1.2, and ANSI N45.22.
2. Performance Reporting will keep you updated with program deviations, limitations, and detailed
listing of changes from one release to the next. Deviations are reported within five working
days from discovery. Reporting includes minor deviations in calculations, library data, program
interface, output reports, plots, project database, etc. Major/substantial errors are reported to all
ETAP users.
ETAP Advantage is beneficial for all types of industries and consulting firms
The OTI Engineering and Development Teams are pleased to present you with the latest ETAP 5.0.3
release. ETAP 5.0.3 is a point release, which includes a number of fixes for the ETAP 5.0.2 release.
ETAP 5.0.3 CD is a complete program and does not require any previous ETAP installation.
We recommend that you utilize this latest release in order to take advantage of the new features and
capabilities. We strive to provide our customers with advanced features and industry standard
engineering tools.
2005 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and Crystal Reports® is a registered
trademark of Seagate Software.
1
Operation Technology, Inc.
17 Goodyear, Suite 100
Irvine, CA 92618-1812
(949) 462-0100
Fax: (949) 462-0200
Support: (949) 462-0400
Email: [email protected]
www.etap.com
ETAP 5.0.2
May 24, 2005
The OTI Engineering and Development Teams are pleased to present you with the latest ETAP 5.0.2
release.
ETAP 5.0.2 is a point release, which includes several enhancements and corrections for the earlier 5.0.1
and 5.0.0 releases. ETAP 5.0.2 is a complete program and does not require any previous ETAP
installation. We recommend that you utilize this latest release in order to take advantage of the new
features and capabilities. We strive to provide our customers with advanced features and industry
standard engineering tools.
For more information about this new release, please take a few moments to read and review the
information below.
2005 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and Crystal Reports® is a registered
trademark of Seagate Software.
1
Before performing calculation, users need to identify the unit transformers for power station
units. By doing this ETAP then automatically determines all the elements within the power
station units including their auxiliary systems, as well as network elements as defined by IEC
60909 Standard.
2) Enhanced the calculation of the breaking current (Ib) according to the adjustments described in
equation (75), page 115 of IEC 60909-0. The effect of equation (75) will reduce the breaking
current slightly. Note that this adjustment is considered optional and applies only to near
generators faults in mesh systems.
Library – etaplib502.lib
1) Released etaplib502 library including new protective device library models.
2) Validated and Verified (V&V) library data per OTI’s Quality Assurance program.
3) Changed Kerite Cable library data (cable reactance for magnetic installation).
4) Added Kerite Cable library data for non-magnetic installation.
5) MV Solid State Trip Relay (Long Time Curve) has been updated.
Manufacturer: Westinghouse, Models: DigiTrip 3000, DigiTrip MV.
6) Implemented a library release number (versioning) for newly issued libraries for the purpose of
library merge.
7) Enhanced library copy and paste capabilities.
8) The following time-current characteristics fuse curves were enhanced by digitizing the
manufacturer curves:
2005 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and Crystal Reports® is a registered
trademark of Seagate Software.
2
9) Corrected the interrupting ratings for the following fuses:
2005 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and Crystal Reports® is a registered
trademark of Seagate Software.
3
Operation Technology, Inc.
17 Goodyear
Irvine, CA 92618-1812
(949) 462-0100
Fax: (949) 462-0200
Support: (949) 462-0400
E-mail: [email protected]
www.etap.com
ETAP 5.0
September 2004
The OTI Development Team is pleased to provide you with the latest ETAP 5.0 release. ETAP 5.0 is a
major upgrade to ETAP 4.7.6.
The new 5.0 release includes major enhancements to existing modules as well as several new analysis
modules, including ETAP Star, which is a new concept for protective device coordination and protection.
ETAP Star has been in design and development for the last two years, and we are very excited about
sharing its features and benefits with our users.
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and Crystal Reports® is a registered
trademark of Seagate Software.
1
w
ETAP Star
Ne ule
Mo
d ENHANCED MODULES
(Device Coordination/Selectivity)
Transient Stability Harmonics
ETAP Star is an advanced concept in performing steady-state and
ETAP Star Features Include: The Transient Stability module has been dramatically expanded to The new Harmonic Analysis module
dynamic coordination and selectivity of protective devices. This is increase the type of transient actions (disturbances, load and generation helps you quickly identify problems,
achieved by utilizing intelligent one-line diagrams, comprehensive • Graphically Adjustable Device Settings changes, relay actions, etc.) you can place on the system. reduce nuisance trips, design and test
device libraries, and an integrated three-dimensional database. • Sequence-of-Operation of Protective Devices Among the many added features are SVC, multi-mass shaft modeling, filters, and distortion limit violations
Designed and developed by OTI, Star is a fully integrated module • Embedded Fault & Motor Acceleration Analyses synchronous motor acceleration with discharge resistor, and alerts. The module provides
within ETAP, with built-in analyses such as short-circuit and motor • Extensive Device Library (Verified & Validated) automatic assignment of reference machine for each isolated subsystem. comprehensive load flow and
acceleration. • Phase & Ground Coordination Modes frequency scan calculations using
• Multi-Function Universal Relays • Partial-Winding, Y-•, Rotor External Impedance, & Soft Starters detailed harmonic models and non-
• (50/51 P, N, G, SG, 51V, 67, 46, & more)
• Motor Point-by-Point Load Model • HVDC Transmission Link integer harmonic filters.
• Built-In Interface with Relay Hardware
• Dynamic Model for Lumped Load • Universal Relay Actions
• Display Actual Relay Transient Response
• SVC (Steady-State & Transient Response) • New Harmonic Filters
• User-Definable Device Library Database
• Transformer LTC Initial & Operating Time Delays • Transformer k Factor Rating
• Fixed Point / Damage Curve Modeling
• Enhanced General Models for Lumped Load • Alerts for VTHD, VIHD, Transformer, Filter, Capacitor, & Cable
• Graphical Time-Difference Calculator
• Synchronous Motor Acceleration with Discharge Resistor • Report Resonance Frequencies & Magnitudes
• Automatic Current & Voltage Scaling of TCC View
• & Pull-in Process • Enhanced General Models for Lumped Load
• Advanced Curve-Fitting Algorithms
• Step & Ramp Changes of Generation Level, and AVR Reference • One-Line Display of Capacitor & Filter Current
• Auto Clipping for All Protective Devices
• Voltage • Generation of Harmonic Sources Based on Device Parameters for
• Click & Drag Curves to Adjust Settings
• Step & Ramp Changes of Synchronous & Induction Motor Loading • VFD, UPS, Charger, & Inverter
• Automatic Layout of the One-Line Diagram in Star View
• Enhanced Fractional Branch Faults
• Print or Plot on Multiple Pages
• (Transmission Line, Cable, & Impedance)
• Automatically Shrink to Fit on a Single Page
• System Zoning & Automatic Reference Machine Assignment
Libraries (New & Enhanced)
• Print or Plot to Various Paper Sizes, Including Full Size Plotters
• for Each Islanded Subsystem OTI has enhanced and created many new libraries with data locking
• Print Comprehensive Reports of Input Data & Study Results
• New Plots and checker capabilities. Also for ETAP 5.0, all libraries related to
• Customizable Print Functionality, Legends, & Device Labeling
• - Absolute Power Angle for Synchronous Generators & Motors protective devices are combined (short-circuit ratings and time current
• Display Input Data & Study Results on the Drawing
• - Generator & Motor Mvar Flows characteristics) into one ETAP library. The new library has been
w • - Terminal Voltage for Synchronous & Induction Motors validated and verified based on published manufacturer data per
Ne cept
Star Sequence-of-Operation Co n • - Difference of Variables for Fast Bus Transfer ETAP’s qaulity assurance program.
• Contactor Open & Close Action
ETAP Star Sequence-of-Operation provides a system wide solution • Control Relay • Solenoid
• Start Synchronous & Induction Motors by Starting Category
for accurate and realistic operating times and states of protective • LV Circuit Breaker • Fuse
• Multi-Mass Shaft Model for Generators & Motors
devices, such as relay, fuse, circuit breaker, trip devices, contactor, • Overload Relay & Heater
• New Bus Frequency Calculations using Electrical Distance Method
etc. The operation time is calculated for each protective device based • Point-by-Point Motor Load
on its settings, time current characteristics, and interlocks for a • Characteristics
specified fault location and type. • Transmission Line Library
ETAP Real-Time (PSMS) • (Phase & Ground Conductors)
With ETAP Star, not only can you work with the time-current curves, • Trip Devices (Solid State, Thermal-
Built on ETAP, the world-leading power system analysis software,
you can also determine the operating time of protective devices • Magnetic, Electro-Mechanical, & Motor Circuit Protector)
ETAP Real-Time is a real-time energy management system used by
simply by placing a fault on the one-line diagram. • Multi-Function (Universal) Relay (50/51 P, N, G, SG, 51V, 67, 46, …)
operators and managers to monitor, control, and optimize power
systems. New Protective Device Library
• Automatically calculate and display the fault current • ABB (BBC) • Federal Pioneer • Protecta
• contributions on the one-line diagram • AEG • Fuji Electric • RTE
• Enhanced State Estimator • Allen Bradley • G&W • S&C
• Graphically place a fault anywhere on the one-line diagram • Allis-Chalmers • GE Multilin • Schlumberger
• & Load Distribution • Alstom • GEC Alsthom • Schweitzer (SEL)
• Determine the operating time and state of all protective • Basler Electric • General Electric • Siba
• PF Meters • Brush • Gould Shawmut (Ferraz) • Siemens
• devices based on the actual fault current contribution • Bussmann • Heinemann • Snemo
• New Real-Time Simulation • Carriere • ITE (BBC) • Southern States
• flowing through each individual device • CEE • Joslyn • SPD Technologies
• Modules • Chance • K Moeller • Square D
• Globally view post fault actions • Combined Technologies • Kearney • Sure-Trip
• Enhanced Intelligent Load • Cooper • KyongBo Electric • Sylvania
• and associated operating time via a tabulated Event Viewer Coordinate via One-Line Diagram • Shedding
• Cooper (Edison) • L&T • Sytek
• Cutler-Hammer • LG • Terasaki
• Graphically examine the operation of protective devices via the • Deesys • McGraw-Edison • Toshiba
• Extended Communication • Dorman Smith • Merlin Gerin • Universal
• one-line diagram • Driescher • MicroelettricaScientifica • Utility Relay
• Protocols • Enertec • Mitsubishi • Westinghouse
• English Electric • Moeller • Xelpower
1 • Federal Pacific • P&B Engineering • ZIV 6
ENHANCED MODULES
w
Ne ule
Added Features to all Modules Motor Acceleration Optimal Capacitor Placement Mo
d
Thanks to user feedback, significant additions and improvements The Motor Acceleration module has been enhanced to reduce the Optimal Capacitor Placement allows engineers to strategically place capacitors for voltage support and power factor correction while
have been made to enhance all network analyses modules. These time it takes to conduct single and group motor acceleration studies. minimizing installation and long-term operation costs. The advanced graphical interface gives users the flexibility to control the capacitor
enhancements include various study options to globally change and Major enhancements include the new soft starters (control motor placement process and graphically view the results. The precise calculation approach automatically determines the best locations and bank
adjust system parameters and topology with a click of the mouse to voltage, current, or torque), alerts (report various violation for motors, sizes. In addition, it reports the branch capacity release and the estimated savings during the planning period due to var loss reduction.
increase your productivity. buses, generators, and engines), unlimited time events, and user-
defined point-by-point motor load modeling features. • Best Location & Bank Size
• Individual and/or Global Tolerance (Length and/or Impedance) for • Minimum Total Installation & Operation Cost
• Cables, Transmission Lines, OLH, Transformers, & Reactors • Partial-Winding, Y-•, Rotor • Voltage Support & Power Factor Correction
• Isolated Subsystem Index • External Impedance, & Soft • Branch Capacity Release & Cost Savings
• Parameter Adjustment Report • Starters • Capacitor Control Method
• Generation Category • Comprehensive Alert View • Review Capacitor Impact on the System
• Transmission Line Coupling • Unlimited Number of Events
• Protection Page (Cable, Transmission Line, Transformer, Generator, • Point-by-Point Motor Load w
Ne ule
• Model
• Induction Motor, Synchronization Motor)
Unbalanced Load Flow Mo
d
• Charging Current for Single-End Open Branches • Plots for Static Loads & Buses
• (Cable, Transmission Line, & Impedance Branch) • Source Voltage Sequencing A robust and efficient power flow solution method must be able to model special features of distribution systems with sufficient accuracy.
• New One-Line Diagram Zoom With ETAP's Unbalanced Load Flow module, you can easily model your unbalanced system with detailed representation of component
• Enhanced Connection Logic for One-Line Diagram unsymmetrical characteristics. Accurate and reliable per-phase results are available to describe your system’s unbalanced operating conditions.
• UPS Output Connection Arc Flash Automatic alarms/warnings and advanced features such as the automatic line constant calculator make it the most advanced Unbalanced
Load Flow program available today.
ETAP Arc Flash Analysis estimates the arc flash
Short-Circuit incident energy under a bolted 3-phase short
• Advanced Current-Injection Method
circuit fault and determines the flash protective
We have enhanced the IEC • Looped & Radial Systems
boundary to live parts for shock protection.
Standard for device evaluation • 1-Phase, 2-Phase, & 3-Phase Unbalanced Load Flow
Design safer power systems by insuring
based on maximum fault current • Unbalanced Branch & Load Modeling
compliance with OSHA 29 CFR 1910.132(d)
through protection devices, and • Transmission Line Coupling
1990, NFPA 70E-2004, and IEEE 1584-2002 Standards.
reporting of braking current • Charging Current for Open-End Branches
as a function breaker time • Phase & Sequence Voltage, Current, & Unbalanced Rates
• System Calculated or User-Defined Fault Current
delay. ETAP 5.0 also • Multiple Demand Factor Non-Linear Loads
• System Calculated or User-Defined Arcing Fault Clearing Time
provides detailed • Real & Reactive Power Losses & Voltage Drop Calculation
• (Interface with ETAP Star)
reports and graphical • Line & Cable Temperature Correction
• System Calculated or User-Defined System Grounding
display of line-to- • Automatic Alert for Device Evaluation
• Arcing Current Variation
ground, line-to-line, • Automatic Determination of Hazard/Risk Category for PPE w
Ne ule
and line-to-line-to- • Create Regulation Arc Flash Hazard Labels for Every Bus Control System Diagram Mo
d
ground fault currents. • Different Label Templates Available for Each Faulted Equipment
• Quick Incident Energy Calculator (Bus Arc Flash Page) ETAP seamlessly integrates power and control systems within one electrical analysis program. The Control System Diagram (CSD) simulates
• User-Defined Equipment Gap Between Conductors & X Factors the sequence-of-operation of control devices such as solenoids, relays, controlled contacts, multi-sequence contacts, and actuators including
• Limited Approach inrush conditions. CSD has the capability to determine pickup and dropout voltages, losses, and current flows at any time instance as well
Load Flow • Boundary Based on NFPA as overall marginal and critical alerts. A large library of equipment enables engineers to quickly model and simulate the action of relays
• 70E Table 2-1.3.4 associated with control interlocks after time delays.
ETAP’s advanced Load • Drag & Drop Control Relays, Solenoids, Contacts, Cables, etc.
• Added Arc Flash
Flow module includes • Control Logic Simulation (Relays, Circuit Breakers, Contacts, etc.)
• Calculation Icons to the
features such as • Voltage Drop Calculation including Inrush Currents
• Short-Circuit Toolbars
automatic device • Battery Discharge Calculations using Actual Control Logics
• Automatically Update Arc
evaluation, summary • Automatic Alert for Pickup & Dropout Voltages
• Flash Analysis Results to
alarms/warnings, and • Automatic Overloading Alerts
• Every Bus
intelligent graphics. Already a robust Simulate Control • Fully Integrated with One-Line Diagrams
power calculation tool, the module has Actions just like • Comprehensive Device Library (Verified & Validated)
enhanced device evaluation, alerts, and reporting. in Real Systems
5 2
NEW Elements Enhanced Elements
w
Ne ule
GIS Map Mo
d
(Geographic Information System) Static Var Compensator (SVC) Generator
ETAP GIS Map superimposes electrical one-line diagrams with the corresponding geographical maps of power generation, transmission, and • Capacitive & Inductive Characteristics • Generation Category • PF Control Mode
distribution systems. Synchronize relevant electrical equipment information from GIS into ETAP and maintain the relationship between them. • Modeling Within & Outside Control Range • MW-Mvar Capability Curve • Xd” Tolerance
• Full Controller Dynamic Modeling • Inertia Calculator (Prime Mover, Coupling Gear, & Generator)
• Data Synchronization with GIS • Several Typical Control Models • Shaft Torsion Parameters • Engine Rating
• Embedded Load Flow & Fault Analyses • Grounding Through Distribution Transformer
• Display Analysis Results on GIS Maps • Graphical Grounding Elements on One-Line Diagram
• Display Unlimited GIS Presentations High Voltage DC
• Perform Add, Modify, or Delete Actions Transmission Link (HVDC)
• View ESRI ArcGIS® Maps in ETAP Power Grid
• Use Map Tools – Zoom In, Zoom • Load Flow Modeling
• Different Combination of Operating Modes for Rectifier & Inverter • Generation Category
• Out, Full Extent, Pan, etc.
• Full AC/DC Controllers Dynamic Modeling • PF Control Mode
• Fully Control Analysis Results
• Displayed on the GIS Map • Current, Power, & Voltage Controllers for Rectifier & Inverter
• Map GIS Equipment Attributes to • Voltage-Dependent Current-Order Limits (VDCOL) Control Model
• Shut-Off & Re-Start Models
Bus
• ETAP Element Attributes
• Perform Data Consistency Checks • Arc Flash Parameters Based on Normal kV
Multi-Function (Universal) Relay • Unbalanced Initial Voltage
• Arc Flash Calculator with Embedded Fault Analysis
• Multi Level & Function • & Protective Device Clearing Time
w
Ne ule
w
Ne ule • Overcurrent (50/51)
Transmission Line Mo
d
ETAP Wizard Mo
d
(Added to Base Modules) • Voltage Control/Restraint (51V)
3 4
NEW Elements Enhanced Elements
w
Ne ule
GIS Map Mo
d
(Geographic Information System) Static Var Compensator (SVC) Generator
ETAP GIS Map superimposes electrical one-line diagrams with the corresponding geographical maps of power generation, transmission, and • Capacitive & Inductive Characteristics • Generation Category • PF Control Mode
distribution systems. Synchronize relevant electrical equipment information from GIS into ETAP and maintain the relationship between them. • Modeling Within & Outside Control Range • MW-Mvar Capability Curve • Xd” Tolerance
• Full Controller Dynamic Modeling • Inertia Calculator (Prime Mover, Coupling Gear, & Generator)
• Data Synchronization with GIS • Several Typical Control Models • Shaft Torsion Parameters • Engine Rating
• Embedded Load Flow & Fault Analyses • Grounding Through Distribution Transformer
• Display Analysis Results on GIS Maps • Graphical Grounding Elements on One-Line Diagram
• Display Unlimited GIS Presentations High Voltage DC
• Perform Add, Modify, or Delete Actions Transmission Link (HVDC)
• View ESRI ArcGIS® Maps in ETAP Power Grid
• Use Map Tools – Zoom In, Zoom • Load Flow Modeling
• Different Combination of Operating Modes for Rectifier & Inverter • Generation Category
• Out, Full Extent, Pan, etc.
• Full AC/DC Controllers Dynamic Modeling • PF Control Mode
• Fully Control Analysis Results
• Displayed on the GIS Map • Current, Power, & Voltage Controllers for Rectifier & Inverter
• Map GIS Equipment Attributes to • Voltage-Dependent Current-Order Limits (VDCOL) Control Model
• Shut-Off & Re-Start Models
Bus
• ETAP Element Attributes
• Perform Data Consistency Checks • Arc Flash Parameters Based on Normal kV
Multi-Function (Universal) Relay • Unbalanced Initial Voltage
• Arc Flash Calculator with Embedded Fault Analysis
• Multi Level & Function • & Protective Device Clearing Time
w
Ne ule
w
Ne ule • Overcurrent (50/51)
Transmission Line Mo
d
ETAP Wizard Mo
d
(Added to Base Modules) • Voltage Control/Restraint (51V)
3 4
ENHANCED MODULES
w
Ne ule
Added Features to all Modules Motor Acceleration Optimal Capacitor Placement Mo
d
Thanks to user feedback, significant additions and improvements The Motor Acceleration module has been enhanced to reduce the Optimal Capacitor Placement allows engineers to strategically place capacitors for voltage support and power factor correction while
have been made to enhance all network analyses modules. These time it takes to conduct single and group motor acceleration studies. minimizing installation and long-term operation costs. The advanced graphical interface gives users the flexibility to control the capacitor
enhancements include various study options to globally change and Major enhancements include the new soft starters (control motor placement process and graphically view the results. The precise calculation approach automatically determines the best locations and bank
adjust system parameters and topology with a click of the mouse to voltage, current, or torque), alerts (report various violation for motors, sizes. In addition, it reports the branch capacity release and the estimated savings during the planning period due to var loss reduction.
increase your productivity. buses, generators, and engines), unlimited time events, and user-
defined point-by-point motor load modeling features. • Best Location & Bank Size
• Individual and/or Global Tolerance (Length and/or Impedance) for • Minimum Total Installation & Operation Cost
• Cables, Transmission Lines, OLH, Transformers, & Reactors • Partial-Winding, Y-•, Rotor • Voltage Support & Power Factor Correction
• Isolated Subsystem Index • External Impedance, & Soft • Branch Capacity Release & Cost Savings
• Parameter Adjustment Report • Starters • Capacitor Control Method
• Generation Category • Comprehensive Alert View • Review Capacitor Impact on the System
• Transmission Line Coupling • Unlimited Number of Events
• Protection Page (Cable, Transmission Line, Transformer, Generator, • Point-by-Point Motor Load w
Ne ule
• Model
• Induction Motor, Synchronization Motor)
Unbalanced Load Flow Mo
d
• Charging Current for Single-End Open Branches • Plots for Static Loads & Buses
• (Cable, Transmission Line, & Impedance Branch) • Source Voltage Sequencing A robust and efficient power flow solution method must be able to model special features of distribution systems with sufficient accuracy.
• New One-Line Diagram Zoom With ETAP's Unbalanced Load Flow module, you can easily model your unbalanced system with detailed representation of component
• Enhanced Connection Logic for One-Line Diagram unsymmetrical characteristics. Accurate and reliable per-phase results are available to describe your system’s unbalanced operating conditions.
• UPS Output Connection Arc Flash Automatic alarms/warnings and advanced features such as the automatic line constant calculator make it the most advanced Unbalanced
Load Flow program available today.
ETAP Arc Flash Analysis estimates the arc flash
Short-Circuit incident energy under a bolted 3-phase short
• Advanced Current-Injection Method
circuit fault and determines the flash protective
We have enhanced the IEC • Looped & Radial Systems
boundary to live parts for shock protection.
Standard for device evaluation • 1-Phase, 2-Phase, & 3-Phase Unbalanced Load Flow
Design safer power systems by insuring
based on maximum fault current • Unbalanced Branch & Load Modeling
compliance with OSHA 29 CFR 1910.132(d)
through protection devices, and • Transmission Line Coupling
1990, NFPA 70E-2004, and IEEE 1584-2002 Standards.
reporting of braking current • Charging Current for Open-End Branches
as a function breaker time • Phase & Sequence Voltage, Current, & Unbalanced Rates
• System Calculated or User-Defined Fault Current
delay. ETAP 5.0 also • Multiple Demand Factor Non-Linear Loads
• System Calculated or User-Defined Arcing Fault Clearing Time
provides detailed • Real & Reactive Power Losses & Voltage Drop Calculation
• (Interface with ETAP Star)
reports and graphical • Line & Cable Temperature Correction
• System Calculated or User-Defined System Grounding
display of line-to- • Automatic Alert for Device Evaluation
• Arcing Current Variation
ground, line-to-line, • Automatic Determination of Hazard/Risk Category for PPE w
Ne ule
and line-to-line-to- • Create Regulation Arc Flash Hazard Labels for Every Bus Control System Diagram Mo
d
ground fault currents. • Different Label Templates Available for Each Faulted Equipment
• Quick Incident Energy Calculator (Bus Arc Flash Page) ETAP seamlessly integrates power and control systems within one electrical analysis program. The Control System Diagram (CSD) simulates
• User-Defined Equipment Gap Between Conductors & X Factors the sequence-of-operation of control devices such as solenoids, relays, controlled contacts, multi-sequence contacts, and actuators including
• Limited Approach inrush conditions. CSD has the capability to determine pickup and dropout voltages, losses, and current flows at any time instance as well
Load Flow • Boundary Based on NFPA as overall marginal and critical alerts. A large library of equipment enables engineers to quickly model and simulate the action of relays
• 70E Table 2-1.3.4 associated with control interlocks after time delays.
ETAP’s advanced Load • Drag & Drop Control Relays, Solenoids, Contacts, Cables, etc.
• Added Arc Flash
Flow module includes • Control Logic Simulation (Relays, Circuit Breakers, Contacts, etc.)
• Calculation Icons to the
features such as • Voltage Drop Calculation including Inrush Currents
• Short-Circuit Toolbars
automatic device • Battery Discharge Calculations using Actual Control Logics
• Automatically Update Arc
evaluation, summary • Automatic Alert for Pickup & Dropout Voltages
• Flash Analysis Results to
alarms/warnings, and • Automatic Overloading Alerts
• Every Bus
intelligent graphics. Already a robust Simulate Control • Fully Integrated with One-Line Diagrams
power calculation tool, the module has Actions just like • Comprehensive Device Library (Verified & Validated)
enhanced device evaluation, alerts, and reporting. in Real Systems
5 2
w
ETAP Star
Ne ule
Mo
d ENHANCED MODULES
(Device Coordination/Selectivity)
Transient Stability Harmonics
ETAP Star is an advanced concept in performing steady-state and
ETAP Star Features Include: The Transient Stability module has been dramatically expanded to The new Harmonic Analysis module
dynamic coordination and selectivity of protective devices. This is increase the type of transient actions (disturbances, load and generation helps you quickly identify problems,
achieved by utilizing intelligent one-line diagrams, comprehensive • Graphically Adjustable Device Settings changes, relay actions, etc.) you can place on the system. reduce nuisance trips, design and test
device libraries, and an integrated three-dimensional database. • Sequence-of-Operation of Protective Devices Among the many added features are SVC, multi-mass shaft modeling, filters, and distortion limit violations
Designed and developed by OTI, Star is a fully integrated module • Embedded Fault & Motor Acceleration Analyses synchronous motor acceleration with discharge resistor, and alerts. The module provides
within ETAP, with built-in analyses such as short-circuit and motor • Extensive Device Library (Verified & Validated) automatic assignment of reference machine for each isolated subsystem. comprehensive load flow and
acceleration. • Phase & Ground Coordination Modes frequency scan calculations using
• Multi-Function Universal Relays • Partial-Winding, Y-•, Rotor External Impedance, & Soft Starters detailed harmonic models and non-
• (50/51 P, N, G, SG, 51V, 67, 46, & more)
• Motor Point-by-Point Load Model • HVDC Transmission Link integer harmonic filters.
• Built-In Interface with Relay Hardware
• Dynamic Model for Lumped Load • Universal Relay Actions
• Display Actual Relay Transient Response
• SVC (Steady-State & Transient Response) • New Harmonic Filters
• User-Definable Device Library Database
• Transformer LTC Initial & Operating Time Delays • Transformer k Factor Rating
• Fixed Point / Damage Curve Modeling
• Enhanced General Models for Lumped Load • Alerts for VTHD, VIHD, Transformer, Filter, Capacitor, & Cable
• Graphical Time-Difference Calculator
• Synchronous Motor Acceleration with Discharge Resistor • Report Resonance Frequencies & Magnitudes
• Automatic Current & Voltage Scaling of TCC View
• & Pull-in Process • Enhanced General Models for Lumped Load
• Advanced Curve-Fitting Algorithms
• Step & Ramp Changes of Generation Level, and AVR Reference • One-Line Display of Capacitor & Filter Current
• Auto Clipping for All Protective Devices
• Voltage • Generation of Harmonic Sources Based on Device Parameters for
• Click & Drag Curves to Adjust Settings
• Step & Ramp Changes of Synchronous & Induction Motor Loading • VFD, UPS, Charger, & Inverter
• Automatic Layout of the One-Line Diagram in Star View
• Enhanced Fractional Branch Faults
• Print or Plot on Multiple Pages
• (Transmission Line, Cable, & Impedance)
• Automatically Shrink to Fit on a Single Page
• System Zoning & Automatic Reference Machine Assignment
Libraries (New & Enhanced)
• Print or Plot to Various Paper Sizes, Including Full Size Plotters
• for Each Islanded Subsystem OTI has enhanced and created many new libraries with data locking
• Print Comprehensive Reports of Input Data & Study Results
• New Plots and checker capabilities. Also for ETAP 5.0, all libraries related to
• Customizable Print Functionality, Legends, & Device Labeling
• - Absolute Power Angle for Synchronous Generators & Motors protective devices are combined (short-circuit ratings and time current
• Display Input Data & Study Results on the Drawing
• - Generator & Motor Mvar Flows characteristics) into one ETAP library. The new library has been
w • - Terminal Voltage for Synchronous & Induction Motors validated and verified based on published manufacturer data per
Ne cept
Star Sequence-of-Operation Co n • - Difference of Variables for Fast Bus Transfer ETAP’s qaulity assurance program.
• Contactor Open & Close Action
ETAP Star Sequence-of-Operation provides a system wide solution • Control Relay • Solenoid
• Start Synchronous & Induction Motors by Starting Category
for accurate and realistic operating times and states of protective • LV Circuit Breaker • Fuse
• Multi-Mass Shaft Model for Generators & Motors
devices, such as relay, fuse, circuit breaker, trip devices, contactor, • Overload Relay & Heater
• New Bus Frequency Calculations using Electrical Distance Method
etc. The operation time is calculated for each protective device based • Point-by-Point Motor Load
on its settings, time current characteristics, and interlocks for a • Characteristics
specified fault location and type. • Transmission Line Library
ETAP Real-Time (PSMS) • (Phase & Ground Conductors)
With ETAP Star, not only can you work with the time-current curves, • Trip Devices (Solid State, Thermal-
Built on ETAP, the world-leading power system analysis software,
you can also determine the operating time of protective devices • Magnetic, Electro-Mechanical, & Motor Circuit Protector)
ETAP Real-Time is a real-time energy management system used by
simply by placing a fault on the one-line diagram. • Multi-Function (Universal) Relay (50/51 P, N, G, SG, 51V, 67, 46, …)
operators and managers to monitor, control, and optimize power
systems. New Protective Device Library
• Automatically calculate and display the fault current • ABB (BBC) • Federal Pioneer • Protecta
• contributions on the one-line diagram • AEG • Fuji Electric • RTE
• Enhanced State Estimator • Allen Bradley • G&W • S&C
• Graphically place a fault anywhere on the one-line diagram • Allis-Chalmers • GE Multilin • Schlumberger
• & Load Distribution • Alstom • GEC Alsthom • Schweitzer (SEL)
• Determine the operating time and state of all protective • Basler Electric • General Electric • Siba
• PF Meters • Brush • Gould Shawmut (Ferraz) • Siemens
• devices based on the actual fault current contribution • Bussmann • Heinemann • Snemo
• New Real-Time Simulation • Carriere • ITE (BBC) • Southern States
• flowing through each individual device • CEE • Joslyn • SPD Technologies
• Modules • Chance • K Moeller • Square D
• Globally view post fault actions • Combined Technologies • Kearney • Sure-Trip
• Enhanced Intelligent Load • Cooper • KyongBo Electric • Sylvania
• and associated operating time via a tabulated Event Viewer Coordinate via One-Line Diagram • Shedding
• Cooper (Edison) • L&T • Sytek
• Cutler-Hammer • LG • Terasaki
• Graphically examine the operation of protective devices via the • Deesys • McGraw-Edison • Toshiba
• Extended Communication • Dorman Smith • Merlin Gerin • Universal
• one-line diagram • Driescher • MicroelettricaScientifica • Utility Relay
• Protocols • Enertec • Mitsubishi • Westinghouse
• English Electric • Moeller • Xelpower
1 • Federal Pacific • P&B Engineering • ZIV 6
ETAP PowerStation 4.7.6
January 2004
The OTI Development Team is pleased to present you with the latest ETAP PowerStation 4.7.6 and
PowerPlot v2.5, Release 167. ETAP PowerStation 4.7.6 is a point release, which includes some
enhancements and corrections for earlier releases.
ETAP PowerStation 4.7.6 release is a complete program and does not require an earlier program
installation.
We encourage you to install this latest release to take advantage of the new features and capabilities.
Please contact OTI sales to purchase the new Arch Flash IEEE 1584 module. We are excited about
providing our customers with advanced features and industry standard engineering tools.
For more information, please take a few moments to read and review the information below:
In the IEEE Std. 1584-2002 method, the empirically derived model is used for voltages in the range of
0.208-15kV. The theoretically derived Lee Model is used for voltage levels above 15kV. The
empirically derived model has a bolted fault current range of 0.7- 106kA. ETAP Arc Flash is available
for both ANSI and IEC Standards.
Arc Flash Analysis with NFPA 70E-2000 Standard continues to be an integral part of the ETAP Short
Circuit Analysis module.
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
2
Hyperlink NEW FEATURE
˙ Drag and drop the hyperlink on any device on the one-line diagram, raceway, or presentation
including composite motors and networks.
˙ Hyperlinks Editor opens automatically after dropping link onto an element or one-line diagram.
o Description
o Web or network address of file
o Tooltip (Roll-over)
˙ Multiple links per element are possible. Hyperlinks are easy to edit and remove.
The auto backup feature can be turned off in the ETAPS.INI file. The default setting is set to “1” to
create backup. To stop auto-backup functions, set the INI file value to “0”.
[ETAP PowerStation]
CreateBackupFile=0
Data Exchange
DXF file format is optimized. File size for each DXF file is considerably less if the file contains minimal
information.
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
3
System Requirements
Minimum Hardware Requirements
Your computer must meet the following minimum hardware requirements to run PowerStation 4.7.4:
• Intel Pentium III
• 256 MB of RAM
• 500 MB available hard disk space
• Parallel, USB*, or Serial* Ports (*PowerPlot licensing not available for these ports)
• CD ROM Drive – Stand Alone Licensing only
Operating System
Your computer must meet the following Operating System and software requirements to use
PowerStation 4.7.4:
Microsoft Windows
• 98SE (Second Edition) • 2000 (Service Pack 2)
• NT 4.0 (Service Pack 6 or higher) • Me
• XP • Internet Explorer 5.0 or higher
Recommended Hardware Requirements
For projects less than 500 busses
• Intel Pentium IV or higher – 2.0 GHz or higher
• 512 MB of RAM
• 20 GB disk space
• Dual 21" monitor with 1024x768 resolution
• Microsoft Windows 2000 Professional, XP Professional, XP Home
For projects over 2,000 buses (10,000, 20,000, 30,000, or unlimited busses)
• Intel Pentium IV Xeon (3.0 GHz or higher) w/Symmetrical Multi-Processing (Dual) and Hyper-
Threading Technology. 533 MHz System Bus.
• 2-8 GB RAM, depending on maximum number of busses - (RD RAM or High-speed DDR RAM)
• 80 GB disk space
• Dual 21" monitor with 1024x768 resolution, or higher
• Microsoft Windows 2000 Professional, XP Professional
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
4
ETAP PowerStation 4.7.0
October 2002
This release incorporates Cable Pulling, Transformer MVA Sizing, Transformer Tap Optimization, IEC
287 temperature analysis (Underground Raceway Systems), and Motor Parameter Estimation modules
into ETAP, making ETAP completely integrated within the Windows environment. In addition, hundreds
of enhancements have been added to the existing modules.
Following the tradition of ETAP integration of electrical and physical properties, the newly added
modules have been designed to fully integrate with existing modules to eliminate multiple instances of the
similar data. For example, the Cable Pulling module uses the data from the existing cables in your ETAP
project files. Thus, the data for a single cable can be used for:
With ETAP, you can model, design, analyze, and optimize your electrical systems. This integration of
data provides consistency throughout the project and eliminates repetitive data entry for the same
element. This in turn reduces the time required to model and analyze a power system in its entirety,
which results in time and cost savings.
Analysis Capabilities
ETAP PowerStation 4.7 is a major upgrade to ETAP PowerStation 4.0.4. The analysis capabilities
available to you will depend on the configuration of modules purchased.
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
5
• Considers ambient temperature, altitude, load growth, diversity factors, etc.
Load Flow
• Unbalanced load flow calculations for panel systems & single-phase networks
• Alert view for panel systems & single-phase networks
• Voltage drop calculation for panel systems & single-phase networks
• Added an option to display load terminal voltages using Load Rated kV or Bus Nominal kV
• Enhanced Equipment Cable Losses Summary Report
• Added option to display bus angles
Short-Circuit
• Graphical plots of transient short circuit currents (IEC 363)
• Generator circuit breaker interrupting duty calculation (ANSI C37.010 – 1999)
• User-definable contact parting time & time constant for HV circuit breakers
• Ith & Ik calculations (IEC 909)
• Expanded arc duration range for Arc Flash Hazard calculations
Motor Acceleration
• New plots & graphical display of power flows for MOVs, generators, & power grids
• New enhanced plots of accelerating motors
• Added an option to display load terminal voltage based on Load Rated kV or Bus Nominal kV
Transient Stability
• Expanded Crystal Reports®
• Expanded calculations to handle frequency-dependent models for induction machines
• Expanded calculations to handle non-windup limiters for exciter types ST2 and ST3 models
Reliability Assessment
• Enhanced program to handle double contingency or multi-stage failure analyses
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
6
Protective Device Coordination
• Motor Operated Valves (MOV)
• Expanded Device Library
One-Line Diagram
• Display of load flow results for single-phase networks
• Display of unbalanced three-phase load flow results for Panel Systems
• Wheel-mouse compatible panning/auto-scrolling
• Drag and drop between the one-line diagrams, composite networks, and Dumpster
• Long output report names (64 characters)
• Detailed display of license information in the About ETAP dialog box
Data Exchange
• DXF export of ETAP project files including graphical annotations, results, etc.
• Enhanced database conversion/synchronizations from common database formats, CSV, XML, IEEE,
GIS & most third party applications
• Enhanced XML export of ETAP project data including nested or flat layout of the one-line diagram
• One-click zip (compress) & e-mail an ETAP project with options to include reports and/or libraries
• XML - Duty cycles for DC elements are added to the XML file export
General
• USB key and serial printer port keys are available to license stand-alone copies
• Enhanced the Help/About PowerStation screen to include detailed license information for
PowerStation keys
• PowerStation projects (MS Access database®) created with earlier versions of ETAP PowerStation
are automatically converted to Microsoft Access 2000 upon opening
• Output filename length is increased from 8 to 64 alphanumeric characters
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
7
• Manufacturer data is added to fuse, cable, battery, and harmonics libraries
• Phase connections are added for Motor Nameplate reports for the Schedule Manager
Minimum PC Requirements
· Intel Pentium II
· 128 MB of RAM
· 500 MB available hard drive space
· 1024x768 resolution
· Parallel Port
· Optional - USB Port (stand-alone licensing only)
· Optional - Serial Port (stand-alone licensing only)
Recommended PC Configuration
· Intel Pentium IV or higher
· 512 MB of RAM
· 2 GB available hard drive space
· 21" monitor with 1024x768 resolution
· Internet Explorer 5.0 or higher
· Parallel Port
· Optional - USB Port (stand-alone licensing only)
· Optional - Serial Port (stand-alone licensing only)
· Microsoft Windows 2000 Professional or XP Professional
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
8
ETAP PowerStation 4.0.4
April 2002
ETAP PowerStation is the most sophisticated engineering power system analysis tool on the market
today. Thousands of hours of design and engineering experience have gone into the overall development
of this software. We have combined state-of-the-art software development experience with real-life,
practical engineering know-how to create an intelligent, yet user-friendly, engineering software.
Analysis Capabilities
ETAP PowerStation 4.0.4 is a minor upgrade to ETAP PowerStation 4.0.0. The analysis capabilities
available to you will depend on the configuration of modules purchased.
Load Flow
• New double-precision Newton-Raphson method with current injection
• Phase-shifting transformer
• New summary output report on bus loadings and overload conditions
• New Alert View to display critical and marginal limit violations
Short-Circuit
• CB Duty calculation based on the maximum-through fault current (ANSI)
• Phase-shifting transformer for ANSI unbalanced faults
• New Alert View to display critical and marginal limit violations
• New Arc Flash analysis program for determining incident energy and flash protective boundary
(ANSI and IEC)
Harmonics
• Filter Overloading
• I*T Index
• Phase-shifting transformer
• Customizable output reports using Crystal Reports format
Transient Stability
• Synchronous motor exciter/AVR system
• Automatic CB operation based on instantaneous relay settings
Overcurrent (50/50G)
Directional Overcurrent (67)
Reverse Power (32)
Motor Overcurrent (50M)
Solid State Trip (SST)
• Loss of excitation action
• New plots for machine terminal impedance (for out-of-step relay setting)
• New plots for branch flows (MW, Mvar, MVA, and Amps)
• IEEE models for Power System Stabilizers (PSS)
• New manufacture models for exciters and governors
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
9
• User-defined Dynamic Models (UDM) interface for:
Exciter/AVR
Governor - Turbine
Power System Stabilizer
• Complete integration with UDM for the Generator Start-Up program
• Phase-shifting transformer
• Segment (fractional) faults for cables and transmission lines
• Remote voltage control bus for all exciters
Libraries
• Reliability Index Library
• Interruption Cost Library
• Expanded existing library data
Cable Ampacity
• ICEA P-55-440 cable tray ampacity calculator (Stolpe Method)
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
10
• Stand-alone test model performance including isolated step response
• Complete integration with Generator Start-Up analysis
• Run-time compile within ETAP PowerStation
• Utilize models within the Transient Stability Program
• Select user-built models within generator editors
• Utilizes block diagrams generated by Simulink®
• Implement system-wide operations such as load shedding, fast bus transfer, islanding, etc.
Motor Starting
• Phase-shifting transformer
2004 Operation Technology, Inc. All rights reserved. Disclosure, use, or reproduction without written authorization by Operation Technology,
Inc. is strictly prohibited. Certain names and/or logos used in this document may constitute trademarks, servicemarks, or tradenames of
Operation Technology, Inc. or other entities. Simulink® is a registered trademark of The Mathworks, Inc., and CrystalTM Reports is a registered
trademark of Seagate Software.
11
Optimal Power Flow
• Generator fuel cost minimization
• Utility electricity cost minimization
One-Line Diagrams
• Single-Phase System (2 and 3 wires)
• Remote Connector
• Panel Systems
• Phase Adapter
• Ground Grid Systems
• New Relays
• Active X (Programmable Objects)
• XML Data Exchange