Gbu005-14-E - Ultra Oval
Gbu005-14-E - Ultra Oval
■ GENERAL
Our workhorse PD flowmeter series is redesigned in this
ULTRA OVAL with the most advanced multi-function
electronic register (ULTRA register) capable of indicating
the instantaneous flowrate and total flow on an easy-to-
read LCD and of providing the pulse and analog output. Meter sizes 39, 41, 45
Meter sizes 55, 56
Significantly improved performance along with compact and
lightweight design are among the many benefits it offers.
■ FEATURES
1. Flow range expanded by 10 to 90% (over the previously
offered OVAL meters of the same sizes).
2. Absence of mechanical reduction gear train combined with
special carbon bearings contributes to low pressure loss Meter sizes 50, 52, 53
and long life. Meter size 57
3. Thanks to pocketless design, the process fluid is virtually
free from stagnation in the measuring chamber-beneficial 5. Output signal is available in two channels simultaneously
to a broad range of fluids, particularly chemicals and in the form of total flow (4/20mA DC factored or
foods. unfactored current pulses) and instantaneous flowrate
4. Microprocessor-based ULTRA register indicates variables- signal (4 to 20mA DC analog).
total flow, both resettable and cumulative, instantaneous 6. A complete series of explosionproof models also available.
flowrate, selectable with mode select switch, plus alarm 7. We also manufacture models approved for applicable
(low battery alarm) on the LCD. high-pressure gas control law.
■ GENERAL SPECIFICATIONS
● Meter Body
Item Description
Meter size 39 41 45 50 52 53 55 56 57
Nominal size 10mm 20mm 25mm 40mm 50mm
Flange 1 group JIS 10K RF, ASME/JPI 150 RF
rating 3 group JIS 16, 20, 30K RF, ASME/JPI 300 RF, DIN PN 10, 16, 20, 25
Flow range See flow range tables (page 3).
Standard -10 to +120℃ (※1)
Operating
Low ———— -60 to +60℃
temperature
High ———— 120 to 200℃ 120 to 260℃
range
Jacketed ———— ——— 120 to 260℃
Accuracy ±0.5% RD and ±0.2% (Option)
Body SCS14 or ▲SCS16
Rear cover SUS316 or ▲SUS316L
Materials Rotors 39:Special carbon only, 41 to 57 : SUS316 or ▲SUS316L
Bearings 39:Special carbon only, 41 to 57 : Special carbon or ceramics (※2)
Shafts SUS316 or ▲SU316L
Connection ———— Rc 1/2 Rc 3/4
Jacketed
Max. operating press. ———— 0.98MPa
Flow direction Right→ left (standard), left→ right, bottom→ top, top→ bottom
※1: Applicable only to ATEX and FM explosionproof. ※ : ▲ Special
※2: With ceramics bearings, the max. allowable temperature is 60℃. (For information, consult the factory.)
http://www.oval.co.jp/english
● Register Specifications
Item Description
Meter size ※39 41 ※45 50, 52, ※53 55, 56 ※57
Local Cumulative totalizing counter (8 digits) 0.1 mL (std.) 0.001 L (std.) 0.001 L (std.) 0.01 L (std.) 0.1 L (std.) [1L (std.)] (※1)
display Reset counter (7digits) C mode 1 mL, 0.01 L 0.01 L, 0.1 L 0.01 L, 0.1 L 0.1 L, 1 L 1 L, 0.01 m3 [0.01m3, 0.1m3] (※1)
(LCD) Instantaneous flow b1 mode 1 mL/h (std.) 0.01 L/h (std.) 0.1 L/h (std.) 1 L/h (std.) 1 L/h (std.) 1 L/h (std.)
(※3) rate (5 digits) b2 mode 0.01 mL/min (std.) 0.0001 L/min (std.) 0.001 L/min (std.) 0.01 L/min (std.)
—— None Local LCD only
Analog 4 to 20 mADC Refer to diagram, page 6.
Type Scaled or unscaled : 0/1=4/20 mADC
Current Pulse
Pulse width Scaled: 1ms (std.), 50 ms Unscaled: 2ms
(※5,6)
Unit of scaled pulse Same as of LCD counter (※2)
Scaled or unscaled : NPN transistor output : Max. impressed voltage 30 VDC
Output signal
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
■ FLOW RANGES
● Meter sizes: 39 to 45
Linearity: ±0.35% Linearity: ±0.15% (Option)
Operating temp. range: –10 to +120°C Unit in L/h Operating temp. range: –10 to +120°C Unit in L/h
Viscosity Less than 0.3mPa・s to 0.8mPa・s to 2mPa・s to 5mPa・s to Viscosity Less than 0.3mPa・s to 0.8mPa・s to 2mPa・s to 5mPa・s to
Meter size 0.3mPa·s 0.8mPa・s 2mPa・s 5mPa・s * 200mPa・s Meter size 0.3mPa·s 0.8mPa・s 2mPa・s 5mPa・s * 200mPa・s
● Meter sizes: 50 to 57
1. Linearity: ±0.35% 4. Linearity: 0.15% (Option)
Operating temp. range: –10 to +120°C (std.) Unit : m3/h Operating temp. range: –10 to +120°C Unit : m3/h
Viscosity Less than 0.3mPa・s to 0.8mPa・s to 2mPa・s to 5mPa・s to Viscosity Less than 0.3mPa・s to 0.8mPa・s to 2mPa・s to 5mPa・s to
Meter size 0.3mPa·s 0.8mPa・s 2mPa・s 5mPa・s 1000mPa・s Meter size 0.3mPa·s 0.8mPa・s 2mPa・s 5mPa・s 1000mPa・s
50 0.3 to 1.6 0.15 to 1.6 0.1 to 1.6 0.05 to 2 0.03 to 2 50 0.5 to 1.6 0.3 to 1.6 0.15 to 1.6 0.08 to 2 0.05 to 2
52 0.7 to 3 0.4 to 3 0.3 to 3 0.15 to 3.8 0.08 to 3.8 52 1 to 3 0.7 to 3 0.5 to 3 0.25 to 3.8 0.15 to 3.8
53 1.1 to 5 0.7 to 5 0.55 to 5 0.28 to 6.4 0.15 to 6.4 53 1.6 to 5 1.1 to 5 0.75 to 5 0.4 to 6.4 0.22 to 6.4
55 1.8 to 11 1.2 to 11 1 to 11 0.4 to 14 0.26 to 14
56 3.5 to 20 2.5 to 20 2 to 20 0.9 to 24 0.6 to 24 Operating temp. range: –10 to +60°C Unit : m3/h
57 8 to 37 5 to 37 4 to 37 2 to 44 1.2 to 44 Viscosity Less than 0.3mPa・s to 0.8mPa・s to 2mPa・s to 5mPa・s to
Meter size 0.3mPa·s 0.8mPa・s 2mPa・s 5mPa・s 1000mPa・s
53 2 to 4.5 1.2 to 4.5 0.6 to 5.7 0.3 to 6.4 52 1.5 to 2.7 0.9 to 2.7 0.55 to 3.4 0.33 to 3.8
55 3.6 to 9 2 to 9 0.8 to 12 0.55 to 14 53 2.4 to 4.5 1.5 to 4.5 0.9 to 5.7 0.49 to 6.4
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
39 41 45
3 10 30
5
1 10
2.5
0 25 50 75 100
Flowrate (%)
40
30
20
10
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
Receiving instruments
ULTRA OVAL
Totalizer
(EL0122)
Batch controller
Valve control
(EL1810)
output
Totalizer
(EL0122)
Scaled pulse (current, open collector, voltage)
Flow computer
Pulse output
OVAL
MODEL
EL4000
(EL4001 series)
■ WIRING CONNECTIONS
(1) Current pulse output (2-wire system) (2) Analog output (2-wire system)
Terminal block
V 24VDC 1
24VDC
Below
Terminal block 600 Terminal block
2
SIG V
1 1 12 to 45VDC
+
3
0V SIG
2 2 Power supply
—
4
G Below
3 3 +
0V 600
4 4 Analog indicator
—
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
(4) Open collector pulse (3-wire system) (5) Voltage pulse (3-wire system)
Terminal block Terminal block
12 to 24VDC
1 V Constant 1 V
E ( 30VDC) voltage 12 to 24VDC
1K
2 SIG R Select R so that the 2 SIG
allowable current be
Max. 50mA 50mA max. Over 10K
3 0V 3 0V
Load resistance ( )
(600)
When connecting a meter to the loop, ensure that the meter and the
load resistance of cable conductor is within the operating limits shown
300
in the figure at right.
Standard: Power supply voltage = 24VDC 0
Load resistance = 250Ω 0 12 (24) 45
Power supply voltage(V DC)
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
×0.1 l ×0.1 l
MIT MIT
φ90
137
8
ATEX:M20
FM:1/
2 -14NPT
Note: 1. For batch controller equipped ULTRA register, refer to General Specification (No. GBC201E).
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
● Meter L B
sizes : 50, 52, 53, 55, 56
90 C D
□130
MODE RESET MODE RESET
MODE MODE
×10 ml ×10 ml
MIT MIT
E
b1:×1 1/h b2:×10 s1/sis b1:×1 1/h b2:×10 s1/sis
100
137
8
ATEX:M20 F
8
FM:1/
2 -14NPT
Conduit connection G1/2
(Only for units with remote
ATEX, FM Exploioproof
output signal)
1. Flange rating 1 group
Meter size Flange rating L B C D E F Weight
(Approx.)
JIS 10K RF 200
50 216.8 86.8 40 φ96 134.8 9kg
ASME/JPI 150 RF 198
● Meter size : 57 JIS 10K RF 200 L B
52 207.8 74.8 43 □ 106
ASME/JPI 150 RF 200 90 C 122.8 D 10kg
ATEX, FM Exploioproof
JIS 10K RF 200
53 231.3 85.8 55.5 □ 106 133.8 11kg
ASME/JPI 150 RF 200
JIS 10K RF 230
55 244.8 92.8 62 □ 130 140.8 16kg
ASME/JPI 150 RF 233
G
JIS 10K RF 250
56 269.8 106.8 73 □ 154 154.8 20kg
ASME/JPI 150 RF 258
□130
MODE RESET MODE RESET
MODE MODE
● Meter L B
×0.1 l ×0.1 l
E
90 C D
100
137
50 ATEX:M20
MODE RESET MODE RESET
×10 ml ×10 ml
FM:1/ -14NPT F
MIT MIT
E
2 ASME/JPI 300 RF Conduit
204 connection G /2
b1:×1 1/h 1
b2:×10 s1/sis b1:×1 1/h
8
b2:×10 s1/sis
output signal)
137
● Meter size : 57 L B
90 C D
ATEX, FM Exploioproof
G
G
□130
×0.1 l ×0.1 l
MIT MIT
137
ATEX:M20 8
FM:1/
2 -14NPT Conduit connection G1/2 8 F
(Only for units with remote
output signal)
1. Flange rating 1 group
Meter size Flange rating L B C D E F G Weight
(Approx.)
JIS 10K RF 350
57 299.8 124.8 85 φ240 172.8 171.5 36kg
ASME/JPI 150 RF 357
Note: For batch controller equipped ULTRA register, refer to General Specification (No. GBC201E).
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
90 C D 90 C D
Cooling Heating
tube tube
130
130
RESET
MODE
X10 ml
MIT
E
E
b1:X1 I/h b2:X10 sI/sis
137
8 F F
● Metersize : 55, 56
L B B
90 C D 90 C D
Cooling Heating
tube tube
130
130
RESET
MODE MODE
X0.1 l
E
MIT
E
8 F F
● Metersize : 57
L B B
90 C D 90 C D
Cooling Heating
tube tube
G
G
130
130
RESET
MODE
X10 ml
MIT
E
137
8 F F
Conduit connection G1/2 (female)
(Only for units with remote output signal)
Note: For batch controller equipped ULTRA register, refer to General Specification (No. GBC201E).
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
MODE RESET
130
MODE
190
X0.1 l
E
MIT
Weight
Meter size Flange rating L B C D E F
(Approx.)
JIS 10K RF 200
52 352.8 58.5 47 □ 106 263.8 13kg
ASME/JPI 150 RF 200
JIS 10K RF 200
53 376.3 69.5 59.5 □ 106 274.8 13.7kg
ASME/JPI 150 RF 200
RESET
130
MODE MODE
C
213
×0.1 l
E
MIT
8 F
Heating fluid connection
Conduit connection (female) G1/2 Rc 3/4
(Only for units with remote output signal)
●Meter size : 57 B
L 90 C D
25
35ß
130
MODE RESET
MODE
307
X0.1 l
E
MIT
8 F Heating fluid
Conduit connection G1/2 (female) connection
(Only for units with remote output signal) Rc 3/4
10
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
■ STRAINERS
L
L
H
H
H
L L
3 3
SR0 1 0 1
1 C
2 (E)
3
(6) SR0 3 0 1
2
C
(E)
3 2
(6) 3 SR0 1C031
4
5
SR0 8 (E)C 0 (6)3 12
4
5
C 3
JIS 30K RF 188
SR013 (E) 0 (6) 3
126
ASME/JPI 300 RF 185
C 3
JIS 10K RF/FF 180
SR021 (E) 0 (6) 1
152
ASME/JPI 150 RF 177
C 3
JIS 30K RF 192
SR023 (E) 0 (6) 3
126
ASME/JPI 300 RF 188
JIS 10K RF/FF 230
SR031 C 0 3 1 165 SCS14A SUS316
ASME/JPI 150 RF 231
11
ULTRA OVAL Meter size: 39 to 57 GBU005E-14
Unit in mm
Min 300
Min 300
Min 500
Min 300
Min300 Min 500
■ OPERATING PRECAUTIONS
1. Every OVAL flowmeter is carefully assembled and 5. It is esseritial that a strainer (supplied by OVAL)
precisely adjusted to measure flows down to minute exclusively designed for OVAL flowmeters be used.
flows before is leaves the factory. Take every precaution 6. This flowmeter is not provided with subtract function.
in uncrating, installation in the piping assembly, and If pulsation in the flow (where the fluid moves back and
testing. forth in the pipeline under the influence of pressure) or
2. Never allow foreign solids to enter the measuring reversal of flow exists, the total counter may show erratic
chamber. reading, accumulating all incoming pulses irrespective of
3. Flush the piping assembly thoroughly. flow direction.
4. Avoid allowing the meter rotors to spin uncontrolled by
directing a stream of air, etc. or allowing the fluid to flow
excessively - even momentarily.
■ ORDERING INFORMATION
Please complete the following form when making inquiries.
1. Model L □ Standard □ High temp. □ Low temp. □ Jacketed
2. Fluid to be measured Name Viscosity mPa・s Specific gravity
3. Flowrate (L/h, m3/h) Maximum Normal Minimum
4. Fluid temperature (℃) Maximum Normal Minimum
5. Ambient temperature (℃) Maximum Normal Minimum
6. Pressure (MPa) Maximum Normal Minimum
7. Flow direction Right ⇆ Left, Bottom ⇆ Top
8. Flange connection Nominal size mm, Flange rating
9. Required linearity ± %
□ Non-explosionproof □ TIIS □ ATEX □ FM □ NEPSI
10. Explosionproof configuration
Pressure-resistant packing (selectable only for ATEX or FM) □ Required □ Not required
11. Accessories □ Strainer, □ Air eliminator, □ Companion flange
12. Quantity Including accessories
(dosing, sampling, blending process, etc.)
13. Application □ Flow integration, □ Flow indication, □ Record, □ Flow control, □ Batch control,
□ CPU interface, □ Others
14. Receiving instrument Type, manufacturer, model, specifications (input, output, power supply, etc.)
15. Distance between flow meter
m
and receiving instrument
The specification as of May, 2015 is stated in this GS Sheet. Specifications and design are subject to change without notice.
Sales Representative:
GS.No.GBU005E
初版 改訂 印刷
01.08 15.05 14.09
(100)