100% found this document useful (1 vote)
618 views

API-510 IS (External) Inspection Report - Modified

This inspection report summarizes the external visual inspection of equipment. It lists the inspector's qualifications and certifications. The purpose of the inspection and dates for the previous, current, and next inspections are noted. Condition codes from 1 to 6 are provided to assess the status of various equipment items, with code 1 being major damage and code 6 being an assessment with no visual inspection.

Uploaded by

Sean Lavergne
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
618 views

API-510 IS (External) Inspection Report - Modified

This inspection report summarizes the external visual inspection of equipment. It lists the inspector's qualifications and certifications. The purpose of the inspection and dates for the previous, current, and next inspections are noted. Condition codes from 1 to 6 are provided to assess the status of various equipment items, with code 1 being major damage and code 6 being an assessment with no visual inspection.

Uploaded by

Sean Lavergne
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

EQUIPMENT EXTERNAL INSPECTION REPORT (while in-service)

EQUIP. NO.: SERVICE DESCRIPTION: NB #: YR. BUILT: EQUIP. TYPE: POSITION: API LETHAL:
CLASS:
UNIT: INSPECTION CO: INSPECTOR: SIGNATURE:
Huntsman Corporation Sean L. Lavergne
CERTIFICATIONS NO( s): API 510: API 653: API 570: AWS CWI: SNT-TC-1A LEVEL II CERTS:
1715 0334 1599 expired 91111131 MT; PT; RT; UT; VT; LVL-1 ET; AET; IR

REASON FOR THIS INSPECTION?

EXTERNAL VISUAL INTERNAL VISUAL TML’S A–SCAN FOR PITS PROOF TEST
PREVIOUS INSPECTION DATE:
THIS CURRENT INSPECTION DATE:
NEXT INSPECTION DUE DATES:

INSPECTION RESULTS
CONDITION CODES - Mark The Appropriate Condition Code For Each Item.
CODE 5
CODE 1 CODE 2 CODE 3 CODE 4 No damage or failure noted.
Major damage - failure or safety item Damage / failure noted: Undesirable condition noted: Minor damage or degradation noted:
noted: Requires repair ASAP but not urgently May cause future problems if repairs Requires re-inspection at a later date to CODE 6
Requires immediate attention and/or are not made. monitor degradation. Data assessment only
verbal communication

SR-See additional report NA-Non Applicable


Note: Unless condition code 6 is marked, it is assumed that visual inspection was performed to verify current condition.

REC. PHOTO
ITEM ACCESS AREA C
O
ON
REV.
TAKEN
DISPOSITION
N SIDE
D
.
C
O
D
E

01 FOUNDATION

02 DRAINAGE

03 WALKWAYS

04 LADDERS:

05 STAIRWAYS

06 PLATFORMS

07 HAND RAILS

08 GUARD GATES

09 SHELL

10 HEAD 1 (TOP, NORTH, OR EAST)

11 HEAD 2 (BOTTOM, SOUTH OR WEST

12 BULGES / DISTORTIONS

13 NOZZLES / FLANGES / BOLTS

14 SHELL ATTACHMENTS

15 EXPANSION JOINT

16 EVIDENCE OF LEAKAGE

17 TELL-TALE HOLES

18 VESSEL SUPPORT OR SKIRT

19 FIRE PROOFING

20 SETTLEMENT

21 ANCHOR SYSTEM

22 LIFTING LUGS

23 STATIC GROUND CONNECTION

24 ASME PLATE (LEGIBLE / VALID)

25 INSUL. / JACKET TYPE & COND.

26 COATING / PAINT

27 SAFETY RELIEF VALVE(S)

28 APPURTENANT SMALL BORE PIPING

29 OTHER(S)