The document provides an agenda and overview of the MPD 600 software training. It details the various software menus, views, and functions for operating the MPD 600 software, including explanations of buttons, measuring guides, reading streams, and questions. The training covers the software for the MPD 600 and other Omicron devices and provides screenshots to illustrate the different software components and settings.

Uploaded by

TXEMA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views

7 Software Slides

The document provides an agenda and overview of the MPD 600 software training. It details the various software menus, views, and functions for operating the MPD 600 software, including explanations of buttons, measuring guides, reading streams, and questions. The training covers the software for the MPD 600 and other Omicron devices and provides screenshots to illustrate the different software components and settings.

Uploaded by

TXEMA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 51

MPD 600 Software Training

Dr. Kay Rethmeier


Rene Hummel
Ole Kessler

© OMICRON Academy 10 April 2011


Agenda

• explanation of every button of the EXPERT software


– what's its function?
– where is it needed?

• measuring guide: how to start

• how to read a stream

• Q&A
mtronix Software

• MPD 600
• MPD 540
• MPD 500

• MI 600
• MI 540

• MPD 402
mtronix Software
Getting Started

• RESET ALL SETTINGS TO DEFAULT!!!

• Change to EXPERT MODE


Main MENU
MENU File
Save Settings…

• Save Creates "mpd.conf"


• Some Problems may be
Solved by Deleting the
"mpd.conf" (New one will be
Generated)

• "Save As…" is a very


Helpful Tool!!!
• Store Different Calibration
Settings!
• Store Settings for Your
Demo-Boxes!
Load… / Reset to Default

• Reload Prepared Settings


– 3PARD Test Box
– CT Peli Case
– Cable LOC Test Box
– Calibration Settings
• No. 1
• No. 2
• No. 3
– Display Settings

• If Nothing Works: RESET to Default


Replay/Stop Replay

• "Replay Recorded Measurement Session…„


Reloads a Recorded Measurement STREAM
– Units will turn to "Stand-By" = SUSPEND

• "Stop Replay" returns to Measuring Mode


– Units will be back On-Line = RESUME
Save Settings…
Mode MENU

• ONE Software
• 3 User-Interfaces
• Password "mtronix" for Returning to EXPERT
Advanced MENU

Suspend/Resume: Lunch/Coffee Break


Power Consumption: max. 4 W
Stand-By: < 10mW
Online: 500mA, ca. 8h
INFO: Discharge Time
Advanced MENU

Features: Customize the Software


Advanced MENU

> April 11

Clear all Gates: Clears ALL Gates


Help MENU

• Software
Version
• Serial
Number
USB-
Controller
Connected Units

BUS 1 => Units 1.x


BUS 2 => Units 2.x
Serial Number
Power Info
WARNINGS!
Connected Units

Max 2x 480 to be Controlled


Max 2x 32 SYNCHRONOUS!
Max 6 Curves (Time/FFT) Displayed
Large Scope View
Large Scope View: Test Voltage

• Test Voltage (Max 7 Curves)

> April 11 Only Visible in


Linear Mode
(Q-Tab)
Large Scope View

• Test Voltage

• 1 (-3-4-6-9-25)

• Gate

• DC

• 3PARD

• Elipse
Large Scope View: Test Voltage

Test Voltage COS-REC, Relevant PD in Slope

10s

20ms,
Manually
Zoomed
Large Scope View
• 1 (-3-4-6-9-25)

QIEC – Overview Available

123 – 234 – 345 - …


Large Scope View
• 1 (-3-4-6-9-25) – Right Mouse Menu

…later…

Special Data Format


for Special
Customer
Large Scope View

• Elipse
Summary Diagram Types

• Application Notes (www.omicron.at)


Small Scope View
Small Scope View: Time

• Signal Voltage over Time


U(t) as Present at PD
Input Port
• NOT Effected by
Bandpass Filtering (Q-
Tab)
• EFFECTED by "PD Input
Filtering" in PD-Tab
• NO COMMEN TIME-
BASE for Multiple Curves!
Small Scope View: Time

• Effect of PD Input Filtering (Low Pass)


Small Scope View: Time

Vertical Curser:
• PD-Tab Selected:
– Trigger Time
– Horizontal Position
• Measure-Tab Selected:
– 2 Measuring Cursers
• Time Integration Limits t1 and
t2

Horizontal Curser:
• Trigger Threshold
Small Scope View: Time

• Maximum Voltage is
Defined by the Pre-
Amplifier/Gain-Settings

• Cut-Off above
Maximum Voltage

• "Locked" Trigger
Threshold Indicates
Maximum Voltage
(=NO Bug!)
Small Scope View: Time

Slider Pos ±Vmax [V]


11 0,005
10 0,011
9 0,026
8 0,058
7 0,136
6 0,323
5 0,754
4 1,647
3 3,843
2 9,140
1 21,327

Max 10VRMS due to Max 2W @ 50


OHM
Small Scope View: Time

Application:
Moving Noise Pulses
• Evaluation of
Pulses in Time
Domain
– Amplitude
– Shape
• Source for FFT-
Calculation!
• Measure Time PD Pulse with Echoes
Differences
Small Scope View: FFT

FFT:
• 0MHz to 32MHz!!!

Auto Scale: 0MHz to 20MHz

Mouse Info: Visible even


OUT OF WINDOW!
Small Scope View: FFT

Calibrator #1

FFT:
• Numeric
Calculation from Calibrator #2
Time Domain
• Shows f-
Characteristics
– PD
– Disturbances
– Set-up
Small Scope View: FFT
FFT: Distinguishing PD Types
Small Scope View: FFT

• Visualization of Filter Settings

Filter
Small Scope View: Q(U)

• Watching PD Activity
• Evaluating Hysteresis
• Up/Down Indicated by Colour
Small Scope View: Replay

• U(t) and QIEC(t)


• Zoomable
• Mouse-Over Info
• Test Voltage for the
Selected Unit Only!

Select Relevant Range


Small Scope View: Trend

Trend Graph: Only One Type of Curve for All Units


• Time Scaling UTC / GMT
• Software Remembers Settings when Changing Curve Types
Measured Quantities Display

Unit Number (PD)

QIEC:
During Measurement/Replay: "Live" Value
After Replay: Average Value of Whole Measuring Time
Replay of Selected Range: Average Value of Selected
Range

RIV: ANSI/NEMA/CISPR

Filter Settings: Center and Bandwidth

PD Counter and Time (If Histogram Active)


Measured Quantities Display

Unit Number of Voltage Trigger Source

Peak / SQR(2)

RMS

Detected Test Voltage Frequency

Unit Selection (PD) / Show Curve / Choose Colour


Measured Quantities Display

PD-Unit <> V-Unit


> April 11

YELLOW if
Measuring Time <
Statistic Time

YELLOW if Test Voltage not Stable: Auto Switch to Internal Trigger


Additional Statistics 1/2
Additional Statistics 2/2
FFT-Tab

Set Up Small Scope View

Deactivate "Auto-
Scale" for
Spectrum
Histrogram

Curve to TXT (1024


dB-Values, 0Hz to
32MHz)

Statistic Function
Q(U)-Tab
Set Up Small Scope View

Please Use this View when Measuring!


Trend-Tab
Visualize Some Values over Time and Create CSV-File
Status Window
© OMICRON Academy