Temporizadores Kuhnke
Temporizadores Kuhnke
Counters are constructed with durable molded bodies. White digits on black background
make units easy to read. Units are available with or without manual resets and a variety
of options. A special type allows the counter to be reset by a pneumatic pulse in
addition to a manual reset button. A predetermining counter includes an output valve to
stop production when the count is reached.
Timers depending on design, are constructed of molded bodies usually with aluminum
bases to provide sturdy fitting connection points. Timers are available in on delay or off
delay versions and incorporate a 3/2 or 5/2 output valve.
Typical timing circuits are included in the catalogue section to assist in designing easy
installations.
Counters and Timers
Series 50 Counters Kuhnke System Logic Devices
50670
The pneumatic counter can be used as an event, part or
lot counter. The counter registers pneumatic impulses on
a 6 digit display. Totalizer operates with impulse pressure
between 2 and 8 bar. The counter can be reset either
manually via a reset button, or by a pneumatic signal to a
specially provided port.
Technical Specifications
6
Counters and Timers
Kuhnke System Logic Devices Series 50 Counters
50680
Counter is used for selecting the number of desired
operations on a production run. The number of
operations is set on the lower scale by holding down a
white button and setting the count to be reached. The
upper scale is a 5 digit totalizer. When the count reaches
the lower scale setting, a built-in 3/2 valve is switched to
provide a pneumatic output to stop machine or signal that
the count has been reached. Valve remains switched
until counter is reset.
Technical Specifications
Op. Pressure: Control Connections: Materials:
2-8 bar. Port Z - Counter pulse input Molded body
Connection: Port Y - Reset Dimensions:
M5 ports Port P - Supply air to 3 way valve Face plate: 60mm W x 75mm H
Display: Port A - Output signal from valve Behind panel: 62.5mm Deep x
Black with white digits Duty Cycle: 51mm Wide x 50mm High
(5 numbers) Continuous Panel Cut Out:
Reset: Min. pulse duration 8 ms 52mm Square
Manual button on cover or Min. pause 10 ms 2 mounting holes required.
pneumatic signal of Operating Ambient: Hardware included.
180 ms duration. 0ºC to +60ºC
Media: Weight:
Filtered air 12 grams
7
Counters and Timers
PM Counters Kuhnke System Logic Devices
Catalogue Number
Standard Clip Mounting Description Panel Mounted Surface Mounted
Standard Screw With Stud
Clip Mtg. Fastening Base Mounting
4 Digit PM14-21 PM14-11 APM14-01 PM14-01
With
Manual 6 Digit PM16-21 PM16-11 APM16-01 PM16-01
Reset
8 Digit Not Available Not Available Not Available Not Available
Options
For Low pressure version (0.5 to 2 bar) add an “L” prefix to the
Base catalogue number.
Base Mount
Mount
A manual reset guard can be added to help prevent accidental
resetting of the counter. Add suffix “V” to the catalogue number.
For a spade key reset add suffix “VS” to the catalogue number.
For a secret reset add an “S” suffix.
Standard designs have 10-32 NPT ports.
Technical Specifications
Op. Pressure: Duty Cycle: Dimensions (approx.):
1.5 to 6.5 Bar Std. Continuous 4 Digit – 22mm H x 33mm W x 66mm D.
0.5 to 2 bar Low Press. Min. pulse duration 8 ms 6,8 Digit – 22mm H x 50mm W x 66mm D.
Connections: Min. pause 10 ms For Screw mtg. add 1” to H dim.
10-32 port, Option 1/8. Operating Ambient: For base mtg. add 1 “ to D dim.
Display: 0ºC to + 60ºC
Black with white digits Weight: Panel Cut Out:
Reset: 7 to 13 grams 4 Digit – 22mm H x 32mm W
With or without manual reset. Materials: 6,8 Digit – 22mm H x 47mm W
Molded body, steel frame.
Media:
Filtered air
8
Counters and Timers
Kuhnke System Logic Devices Series 51 Mini Timer
2 to 30 Seconds 51020-03
20 to 300 Seconds 51020-30
Rear Mounting
Technical Specifications
Op. Pressure: Reset: Operating Ambient:
2 to 6 bar By removal line pressure 0ºC to 60ºC
Connections: Reset Time: Dimensions (inches):
M5 200 ms 24mm W x 48mm H x 68mm D.
Media: Repeatability: Panel Cutout:
Filtered, dry air. ± 0.3 Sec. 51020-03 20mm W x 45mm H.
Non-lubricated ± 3 Sec. 51020-30 Mounting:
Operating Valve: Time Setting: Retaining Clip.
3/2 (NC) - internal exhaust Via adjustment knob.
Orifice size - 1mm Setting Accuracy:
Flow @ 6 bar – 40 litre ± 0.6 Sec. 51020-03
Timing Start: ± 6 Sec. 51020-30
Application of line Materials:
pressure to port 1. Molded housing.
9
Counters and Timers
Series 51 Timers Kuhnke System Logic Devices
Bottom Ported
M5
Technical Specifications
Op. Pressure: Reset: Materials:
1.5 to 8 bar By removal of pilot (or Line) Polyamide housing, aluminum
Connections: signal –independent of whether base, Buna N seals.
M5 (10-32) or the time interval has elapsed or not. Operating Ambient:
1/8 ports Reset Time: -10ºC to 60ºC
Media: 200 ms Dimensions (mm):
Filtered air, non lubricated. Repeatability: M5 port 1/8 port
Operating Valve: ± 2% of selected time. Height 92 105
3/2 - internal exhaust Time Setting: Width 36 36
Orifice size - 2mm Via adjustment knob. Length 70 70
Flow @ 6 bar – 200 liters Operation: Weight 35 gr. 45 gr.
Timing Start: Timing cycle uses atmospheric
Application of pilot (or Line) pressure drawn into vacuum. Mounting:
pressure to control port. Air Consumption: Via 4 holes in base.
During timing cycle only -3 l/m
10
Counters and Timers
Kuhnke System Logic Devices Series 51 Timers
Selection Chart
Diagrams Catalogue Number
Timing Range
1/8 Side M5 Bottom
ported Ported
.5 to 60
Seconds
51006-00US 51006-00
On Delay Off Delay On
(Normally Closed) (Normally Open) 1 to 120
Delay 51012-00US 51012-00
Seconds
(NC)
1 to 180
Seconds
51018-00US 51018-00
Connections .5 to 60
Seconds
51006-01US 51006-01
Off
1/8 Side Ported Timers Delay 1 to 120
Seconds
51012-01US 51012-01
Side ported timers are supplied with a 10/32 port plug (NO)
1 to 180
to set up preferred connections. Seconds
51018-01US 51018-01
Control input signal must be at the same pressure as system line pressure.
11
Counters and Timers
PMT Timers Kuhnke System Logic Devices
Technical Specifications
Op. Pressure: Reset: Materials:
1 to 6.5 bar. Automatic by removal of Acetal and polycarbonate
Connections: pilot signal. enclosure. Diaphragms-
10-32 or 1/8 ports Reset Time: Buna N
via bottom sub plate 60 ms @ 3 bar Operating Ambient:
Control Pressure: Repeatability: OºC to 65ºC
(A) Low Press. – 1 to 6.5 bar ± 3% of selected time. Dimensions (mm):
(B) Standard – 2 to 6.5 bar Time Setting: (including sub plate)
Media: Via adjustment knob. Height – 55
Filtered air or non-aggressive Accuracy ±10% Width – 38
gas, non-lubricated. Operation: Depth – 108
Timing Valve: Timing cycle uses Mounting:
atmospheric pressure Via sub plate (2 holes) or if
Flow @ 6.5 bar –0.3 liters drawn into vacuum. Panel mounted, through a
Dial Indicator: Air Consumption: 38mm square cutout.
Displays set time. 0.3 l/m @ 6.5 bar 2 mounting holes required,
Timing Start: hardware included.
Application of pilot pressure
to control port.
12
Counters and Timers
Kuhnke System Logic Devices PMT Timers
Selection Chart
Catalogue Number
Timing Range
Subplate Panel Mount Panel Mount
Mounting Vertical Bezel Horizontal Bezel
0.3 to 3 Seconds PMT1D1B3 PMT1D2B3 PMT1D3B2
13
Counters and Timers
PT Timers Kuhnke System Logic Devices
Technical Specifications
Op. Pressure Reset: Operating Ambient:
0.5 to 10 bar.I On Delay - Removal of pilot -30ºC to 70ºC
Connections: pressure from control port. Dimensions (mm):
1/8” NPT ports Off Delay - Application of pilot Height – 134
Control Pressure: pressure to control port. Width – 63 -
0.5 to 10 bar Reset Time: Depth – 63
Media: 60 ms @ 3.5 bar Mounting:
Filtered air or non-aggressive Repeatability: Surface or panel mounted.
gas, non-lubricated. Up to 200 sec. - ± 5%. Drilling Plan (panel mount):
Output Valve: Over 200 sec. - ± 10%. 81 dia. hole.
Time Setting:
Flow @ 6.5 bar – 250 liters Via dial.
Multi purpose 3/2 spool. Accuracy ±10% of full scale.
Dial Indicator: Operation:
Displays set time. Timing cycle uses
Timing Start: atmospheric pressure.
On Delay - Application of pilot Materials:
pressure to control port. Zamak housing, polycarbonate
Off Delay - Removal of pilot knob, aluminum valve with stainless
pressure to control port. spool. Diaphragms - Buna N
14
Counters and Timers
Kuhnke System Logic Devices PT Timers
Selection Chart
Catalogue Number
Timing Standard Vertical
Panel Mounted
Range Surface Mount
On Off On Off
Delay Delay Delay Delay
0.1 to 1 Second PT31A PT41A PT35A PT45A
Diagrams Options
Surface mounted units are calibrated for mounting in
the vertical position. If horizontal mounting is required,
add suffix “Y1” to the catalogue number. For a
stainless steel fitting mounted on the pilot port add
On Delay Off Delay suffix “SS”. To include a Dial Stop set at the factory
(which prevents settings above or below a given
Port Identification number) add suffix ”DS” and specify setting. For a
Tamper Proof Cover add suffix “TP” to the catalogue
Port C - Control input signal number.
1 - System air supply
2 - Valve output Power Connections
3 - Exhaust
For installations requiring larger output valves, use the
On Delay Timer Operation standard timer and connect a pneumatically operated
Pilot pressure is applied to the control port to start single air piloted 3/2or 5/2 valve of the size required to
timing. After the timer reaches its set time, the valve the timer output. Contact factory with size
switches over. Removal of the pilot signal at any time requirements.
resets the timer.
Typical Circuits
Off Delay Timer Operation
Applying pilot pressure of at least 100ms in duration to See typical timing circuit diagrams at the end of the
the control port shifts the valve. When the pilot timer catalogue section for help in constructing
pressure is removed, the timing sequence begins. pneumatic timer circuits.
After the timer reaches its set time, the valve switches
off. Re-applying the pilot pressure resets the timer and
valve.
15
Counters and Timers
Series 54 Timers Kuhnke System Logic Devices
Technical Specifications
Op. Pressure: Time Setting: Timing Sequence:
0-10 bar Via front dial knob. Adjustable On delay or off delay
Control Pressure: throughout timing range depending on valve
1.5 to 10 bar Accuracy of Setting: connections.
non-lubricated air ± 2%
Output Valve: Repeatability: Operating Ambient:
5/2 ± 1% of end scale value. 0ºC to 60ºC
Flow – 200 liters @ 6.5 bar Operation: Materials:
Orifice size - 2mm Independent regulated air Lexan case, cast aluminum
motor. Air consumption 10 l/m rear housing, nylon, brass, and
Connection: Output air piloted 5 way valve. stainless alloy mechanism.
M5 ports Reset: Dimensions (mm):
Media: Automatic - by removal of Faceplate –72 square Behind
Filtered air or gas. control pressure. panel –112 D x 66 H x 66 W.
Non-lubricated. Reset Time: Panel Cutout:
Indicators: 200 ms. 66mm square
Displays set time and time Mounting:
remaining before valve Spring clips.
actuation.
16
Counters and Timers
Kuhnke System Logic Devices Series 54 Timers
Selection Chart
Timing Sequence
Catalogue Number
Timing Range
Standard With Rotor
Timer Stop Option
0.3 to 10 Seconds 54021 54050
17
Counters and Timers
Typical Timing Circuits Kuhnke System Logic Devices
18
Counters and Timers
Kuhnke System Logic Devices Typical Timing Circuits
To Device Timer
Control
Port
Typical Timer
Pushbutton Valve On Delay
3/2
(or other valve with Timer
momentary output signal Output
shorter than set time
delay). ڒ
Double Air Air Supply
(Connection depends
Piloted Valve
3/2 ڒ on timer used.)
Air Supply
ڒ
Air Supply
Operation
5/2 Double Air Pilot Valve
A 5/2 double air pilot valve can be substituted when
Pressing the pushbutton sends a signal to switch the air piloted
operating a double acting cylinder or for dual valve on. The valve output is connected to the device to be
alternate outputs. Note output connections. All other controlled and to the timer control port. When the timer reaches
connections same as the 3/2 diagram. it’s set time it sends a signal back to the air pilot valve resetting it,
turning off the output to the device. The timer resets.
19
Counters and Timers
Typical Timing Circuits Kuhnke System Logic Devices
Timer # 2 Timer # 1
On Delay On Delay
Output A
Output B
(if required)
To port 12 (14)
of air pilot valve
Double Air
Piloted Valve
5/2.
ڒ
Air Supply
Continuous cycling is accomplished by the use of 2 timers operating a double To port 2 (4)
air piloted valve. Off and on times are dependent on the type and set time of of air pilot
valve
timers used. The size of the air piloted valve determines the air volume output.
The position of the air piloted valve determines the start up of the timing Series 54 Timer Connections
sequence. If the timing sequence must be restarted in a specific order, a reset Timer diagrams shown are 3/2types.
circuit must be added at port 12 of the air piloted valve to move it to the start 54 Series timers have a 5/2 valve
output with an isolated pilot port.
position prior to resuming operation.
Operation
Air supply to From output
System pressure is turned on. Air flows through port 2 of the pilot valve to drive pilot valve of Timer 2
timer #1 and the device being controlled. When timer 1 reaches set time, it
sends a signal to port 14 of the pilot valve, switching the air output to port 4,
starting the timing sequence on timer #2 and shutting down timer 1 and the
output to the device being controlled. When timer 2 reaches set time, a signal is OR
Logic
sent to port 12 of the piloted valve resetting it and restarting the cycle. Valve
20
Counters and Timers
Kuhnke System Logic Devices Typical Timing Circuits
Operation
21
Counters and Timers
Typical Timing Circuits Kuhnke System Logic Devices
To Device
Timer
Control
Port
Typical Timer
On Delay
Stop
Timer
Output
ڒ
Button Air Supply
3/2 (Connection
OR depends on
Logic timer used.)
Valve
Double Air
ڒ
Piloted Valve
3/2
Start
Button
3/2
ڒ
Air Supply
ڒ
Separate start-stop pushbuttons can be used in conjunction with a To Timer
double air piloted valve and an “or” logic valve to control a timing Control Port
circuit if required. A wide selection of types and colours of
pushbuttons is available to meet design requirements. The size of
the air piloted valve determines the air volume output.
Operation
Pressing the start pushbutton sends a signal to switch the air piloted
valve on. The valve output is connected to the device to be controlled 5 Way Double Air Pilot Valve
and to the timer control port. When the timer reaches it’s set time it A 5 way double air pilot valve can be substituted
when operating a double acting cylinder or for
sends a signal back to the air pilot valve resetting it, turning off the alternating outputs. Note output connections. All
output to the device. To stop the timing (ie. emergency stop) press other connections same as the 3/2 diagram.
the stop button, which sends a signal via the “or” logic valve to reset
the double air piloted valve.
Any on delay timer (consider length of time required and mounting preference).
Pushbutton 3/2 (choice of colour)- Cat. nos. 76022-62-21 (Red), -23 (Black) or -24 (Green).
Double air piloted valve 3/2- Cat. no. 76022-71-22 (1/8 Ports).
For larger sizes of double air piloted valves use a 5/2 valve and plug port 2 for 3/2 operation. Connect device and
timer control to port 4 of 5/2 valve. Use Cat. nos. 76047-81-42 for 1/4 ports or 76067-81-42 for 1/2 ports.
Logic valve-“OR” cat. no. 47003.
22