This document provides specifications for the MBW Series of basic water-cooled generators from Masons ranging from 18-45kVA. The generators are suitable for construction, mobile workshops, and emergency standby applications. They feature a diesel engine, brushless alternator, automatic control panel for monitoring and protection, and an optional load transfer switch. Key specifications including power output, engine details, fuel tank capacity, noise levels, dimensions, and weight are provided for each model.

Uploaded by

Goga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
430 views4 pages

Masons - Industrial - MBW - 18-45W - 50Hz

This document provides specifications for the MBW Series of basic water-cooled generators from Masons ranging from 18-45kVA. The generators are suitable for construction, mobile workshops, and emergency standby applications. They feature a diesel engine, brushless alternator, automatic control panel for monitoring and protection, and an optional load transfer switch. Key specifications including power output, engine details, fuel tank capacity, noise levels, dimensions, and weight are provided for each model.

Uploaded by

Goga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

BASIC / WATER COOLED

MBW Series
18-45W
The best choice as quality/price rate.
Suitable for any kind of user.
Easy to transport and maintain.

Main applications:
• Construction
• Mobile Workshop
• Emergency stand-by (residential / small industry)
BASIC / WATER COOLED

EASY FUEL REFILLING PROTECTIONS:


THROUGH EXTERNAL •M
 oving and rotating
CAP parts protections against
accidental contacts

OIL DRAIN VISUAL FUEL LEVEL


PIPE WITH CAP: INDICATOR
•O
 il draining facilities

GENERATING SET MBW18W MBW25W MBW35W MBW45W


MAIN DATA
POWER RATING kVA kWe kVA kWe kVA kWe kVA kWe

STAND BY POWER - LTP 18,1 14,5 24,0 19,2 33,0 26,4 42,5 34,0

PRIME POWER - PRP 17,3 13,9 21,9 17,5 32,5 26,0 39,6 31,7

VOLTAGE 400 400 400 400

FREQUENCY 50Hz 50Hz 50Hz 50Hz

DIESEL ENGINE
BRAND Weichai Weichai Weichai Weichai

MODEL WP2.1D18E2 WP2.5D22E2 WP3.9D33E2 WP4.3D38E2

FUEL Diesel Diesel Diesel Diesel

NUMBER OF CYLINDERS / DISPLACEMENT (cc) 4 in line / 2088 4 in line / 2540 4 in line / 3860 4 in line / 4330

ASPIRATION Natural Natural Natural Natural

COOLING SYSTEM Water Water Water Water

STARTING SYSTEM / ELECTRIC CIRCUIT (Volt) Electric / 12 V Electric / 12 V Electric / 12 V Electric / 12 V

SPEED (rpm) 1500 1500 1500 1500

SPEED GOVERNOR (Type) Mechanical Mechanical Mechanical Mechanical

STAND-BY POWER [LTP] (kWm) 18,3 24,2 36,6 41,8

PRIME POWER [PRP] (kWm) 17,5 22,0 33,3 38,0

FUEL CONSUMPTION @ 75% / 100% PRP (L/h) 3,68 / 4,90 4,62 / 6,16 6,51 / 8,63 7,93 / 10,49

ALTERNATOR
TYPE Brushless Brushless Brushless Brushless

POLES 4 4 4 4

VOLTAGE REGULATION SYSTEM Electronic Electronic Electronic Electronic

GENSET VERSION OPEN CANOPY OPEN CANOPY OPEN CANOPY OPEN CANOPY
FUEL TANK
MATERIAL Plastic Plastic Plastic Plastic

CAPACITY (L) 51 51 51 51

AUTONOMY @ 75% PRP (h) 13,86 11,04 7,83 6,43

NOISE LEVEL
NOISE POWER [LWA] - dB(A) - 96 - 96 - 96 - 96

NOISE PRESSURE @ 7m - dB(A) - 67 - 67 - 67 - 67

OVERALL DIMENSIONS
LENGTH (mm) 1650 1650 2200 2200

WIDTH (mm) 1000 1000 1030 1030

HEIGHT (mm) 1130 1130 1320 1320

DRY WEIGHT (Kg) 405 510 470 590 690 910 790 1010
BASIC / WATER COOLED

ACP - Automatic control panel


Automatic control panel mounted on the generator, complete with digital control
unit Inteli Nano NT Plus for monitoring, control and module for engine protection.

DIGITAL INSTRUMENTATION (Inteli Nano NT Plus)


• Mains voltage
• Generator voltage (3 phases)
• Generator frequency
• Generator current (1 phase)
• Battery voltage
• Running hours

COMMANDS AND OTHER


Canopy version
• Push-button for manual or auto operation modes selector
• Push-button to start & stop generator in manual operations
• Up / down buttons for menu pages changing and parameters setting
• LEDs to indicate engine running / operating mode and warning / alarm
• Emergency stop button
• Remote starting availability
• Automatic battery charger

PROTECTION
• Engine protection: low oil pressure, high engine temperature
• Generator protection: under/over voltage, under/over frequency, battery
charger failure, earth fault, reverse power
• Circuit breaker protection: III poles

OUTPUT PANEL ACP


• Terminal connection for ACP and LTS panel
• Output sockets (option):
Open version - 32A 3P+N+T for MBW18-25W
- 63A 3P+N+T for MBW35-45W

LTS - Load transfer switch - Accessories ACP


The Load Transfer Switch (LTS) panel operates the power supply changeover
between the generator and the Mains in backup applications, guaranteeing the
feeding to the load within a short period of time.
It consists of a standalone cabinet which can be installed separate from the
generator. The logic control of the power supply changeover is operated by
means of the Automatic Control panel mounted on the generator, therefore no
logic device is required on the LTS panel.