The document summarizes the specifications of the PIC1000 process indicator. It can accept various sensor inputs including thermocouples, RTDs, current, voltage, and mV. It has high indication accuracy of ±0.25% and features 4 alarm outputs, RS-485 serial communication, 24VDC sensor supply, and optional analog retransmission or communication outputs. The device has a 4-digit LED display and operates on an input power of 85-270VAC/DC or optional 24VDC.

Uploaded by

industrialindia
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
232 views1 page

Digital Process Indicator Selectron PIC1000

The document summarizes the specifications of the PIC1000 process indicator. It can accept various sensor inputs including thermocouples, RTDs, current, voltage, and mV. It has high indication accuracy of ±0.25% and features 4 alarm outputs, RS-485 serial communication, 24VDC sensor supply, and optional analog retransmission or communication outputs. The device has a 4-digit LED display and operates on an input power of 85-270VAC/DC or optional 24VDC.

Uploaded by

industrialindia
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PIC1000 PROCESS INDICATOR

6. INDICATION ACCURACY:
0.25% of Span ±1oC (After 20min. Warmup).
7. CONTROL AND ALARM OUTPUTS:
Relay output : 5A @ 250VAC or 24VDC.
8. OUTPUT : 4 nos.
Alarm modes : Alarm High, Alarm Low, Band, Fail
output and fault diagnosis.
48x96 Hysteresis : Programmable.
Annunciator : Programmable.
t
R oH

ia n

Sc
omp
l Reset Action: Programmable automatic or latched.
Standby Mode: Programmable enable or disable.
FEATURES 9. SENSOR SUPPLY : 24 VDC to power the sensors.
10. LINEAR DC OUTPUT: (optional)
! Universal input- Accepts Sensor Inputs Re-transmission : 4 to 20 mA or 0 to 5 V or 0 to 10 V.
(Thermocouple or RTD), Current, Voltage, & mV.
Update rate: 100msec.
! High Indication Accuracy: ± 0.25%. 11. SERIAL COMMUNICATIONS: (optional)
! Sensor Error Compensation (offset) and Break Interface standard : RS485
Detection. Communication Address: 1 to 99, max of 32
units per line
! 4 Alarm outputs.
Protocol : MODBUS
! Status Indicators for outputs. 12. ENVIRONMENTAL CONDITIONS:
! Programmable Delay time for alarm. Operating : 0 to 50OC,
Storage : -5 to 50OC.
! 25 Program settings for each alarm.
Humidity : 85% RH.
! RS-485 Serial Communication (MODBUS). 13. ISOLATION BREAKDOWN RATINGS:
! 24 VDC Sensor Supply. AC line with respect to all inputs and outputs: 2000
! Parameter Security via Programmable Lockouts. Volts.
! 85 to 270 VAC/DC supply voltage (also available 24 All other inputs and outputs with respect to relay
VDC models). contacts: 2000 VAC.
14. WEIGHT : 300 grams .
! Compliance: CE, RoHS

SPECIFICATIONS PRODUCT CODE


1. DISPLAY: 4-digit (7 segment LED) 0.5" high. MODELS RETRANSMISSION OUTPUT COMMUNICATION
Display Messages:
PIC1000-A X X
“Or” - Appears when measurement exceeds
range or open sensor is detected. PIC1000-D-1 0-20mA
PIC1000-D-2 4-20mA
“rE” - TC reverse. X
PIC1000-D-3 0-5V
Display alternating between: PIC1000-D-4 0-10V
PV & HA-AL No. for high alarm. PIC1000-E-1 0-20mA
PV & LA-AL No. for low alarm. PIC1000-E-2 4-20mA
PIC1000-E-3 0-5V
LED Status Annunciators: Alarm ON ( 4nos).
PIC1000-E-4 0-10V
2. POWER:
85 to 270 VAC / DC , 50 or 60Hz, 5VA. NOTE : For 24VDC models add suffix ‘- 24’
Optional: 24VDC (Consult Factory).
3. SETTINGS: Via three keys on front panel.
4. MEMORY: Nonvolatile EEPROM retains all
programmable parameters and values. TERMINAL CONNECTIONS
5. MAIN SENSOR INPUT: (Universal) mV/TC/RTD
-
+

o o Short for Analog


Temperature units : C/ F. PT100 output
Resolution : Temperature: 1 / 0.1 -
+

B A B’
Signal input: 0.001, 1 2 3 4 5 6 7 8 9 10
0.01, 0.1 & 1 decimal
22 24
RS485

point selectable.
-

mA+ V+ mA / V- Sensor
supply
Thermocouple inputs
+

21 -
23
+

J : -200 to 750oC K : -200 to 1350oC


T : -200 to 400oC R : 0 to 1750oC 11 12 13 14 15 16 17 18 N L
S : 0 to 1750oC C : 0 to 2300oC NO1 NO2 NO3 NO4 COM GND +24V
- +
E : -200 to 750oC B : +150 to 1820oC
N : -200 to 1300oC L : -200 to 600oC
U : -200 to 900oC W : 0 to 2300oC DIMENSIONS (in mm) Panel Cutout
Platinel II: 0 to 1390oC
RTD inputs (2 wire or 3 wire)
50 45 46
PT100 : -100 to 850oC. PT1000 : -200 to 300oC.
Signal inputs 97.5
Voltage : 0 to 10 VDC 88 92
mV (linear) : -5 mV to 56mV, 0 to 100 mV. 10
Current : 0 to 20 mA
Industrial Supply Syndicate, 54, Ezra Street, Kolkata - 700 001
Phone: 32916080, 22356676 Fax: 033 3022 2923 Email: [email protected]