This document appears to be a technical specifications sheet for a lighting fixture called "VIRGINIA". It includes photometric data like light intensity distribution curves and glare index values. Glare index values are provided for various room sizes and viewing directions in relation to the fixture. Correction factors for glare index are also shown accounting for variations in observer position and total lumen output of 2700 lumens.

Uploaded by

jmrdesigner
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views

Project 1: Partner For Contact: Order No.: Company: Customer No.

This document appears to be a technical specifications sheet for a lighting fixture called "VIRGINIA". It includes photometric data like light intensity distribution curves and glare index values. Glare index values are provided for various room sizes and viewing directions in relation to the fixture. Correction factors for glare index are also shown accounting for variations in observer position and total lumen output of 2700 lumens.

Uploaded by

jmrdesigner
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

DIALux 4.

9 Output Página 1 de 5

Project 1

Partner for Contact:


Order No.:
Company:
Customer No.:

Date: 14.04.2011
Operator:

DIALux 4.9 Output Página 1 de 5


DIALux 4.9 Output Página 2 de 5

Project 1
14.04.2011

Operator
Telephone
Fax
e-Mail

LEDSC4 00-4339-21-05 VIRGINIA / Luminaire Data Sheet

Luminous emittance 1:

135° 150° 165° 180° 165° 150° 135°

160

120
120° 120°

80

105° 105°

90° 90°

75° 75°

60° 60°

45° 30° 15° 0° 15° 30° 45°

cd/klm  62%


C0 - C180 C90 - C270

Luminaire classification according to CIE: 21 Luminous emittance 1:


CIE flux code: 46 78 95 21 62
Glare Evaluation According to UGR
VIRGINIA
 Ceiling 70 70 50 50 30 70 70 50 50 30
 Walls 50 30 50 30 30 50 30 50 30 30
 Floor 20 20 20 20 20 20 20 20 20 20
Room Size Viewing direction at right angles Viewing direction parallel
X Y to lamp axis to lamp axis

2H 2H 12.7 13.4 13.9 14.5 16.1 12.8 13.5 14.0 14.6 16.1
3H 13.9 14.4 15.0 15.6 17.1 14.0 14.5 15.1 15.7 17.2
4H 14.2 14.7 15.3 15.8 17.4 14.3 14.8 15.4 15.9 17.5
6H 14.3 14.8 15.5 15.9 17.5 14.4 14.9 15.6 16.1 17.7
8H 14.3 14.8 15.5 15.9 17.5 14.4 14.9 15.6 16.0 17.7
12H 14.3 14.7 15.5 15.9 17.5 14.4 14.9 15.6 16.0 17.6
4H 2H 12.8 13.4 14.0 14.5 16.1 12.9 13.4 14.1 14.6 16.2
3H 14.1 14.5 15.3 15.7 17.3 14.2 14.6 15.4 15.8 17.4
4H 14.5 14.9 15.7 16.0 17.7 14.6 15.0 15.8 16.1 17.8
6H 14.7 15.0 15.9 16.2 17.9 14.8 15.2 16.0 16.3 18.0
8H 14.7 15.0 15.9 16.2 17.9 14.9 15.2 16.1 16.3 18.0
12H 14.7 15.0 15.9 16.2 17.8 14.9 15.1 16.1 16.3 18.0
8H 4H 14.5 14.8 15.7 15.9 17.6 14.6 14.9 15.8 16.0 17.7
6H 14.7 15.0 15.9 16.2 17.8 14.9 15.1 16.1 16.3 18.0
8H 14.8 15.0 16.0 16.2 17.9 14.9 15.2 16.2 16.3 18.0
12H 14.8 15.0 16.0 16.2 17.9 15.0 15.2 16.2 16.4 18.1
12H 4H 14.4 14.7 15.6 15.9 17.5 14.5 14.8 15.7 16.0 17.6
6H 14.7 14.9 15.9 16.1 17.8 14.8 15.0 16.0 16.2 17.9
8H 14.8 14.9 16.0 16.2 17.8 14.9 15.1 16.1 16.3 18.0

Variation of the observer position for the luminaire distances S

S = 1.0H +0.1 / -0.2 +0.1 / -0.2


S = 1.5H +0.4 / -0.7 +0.4 / -0.6
S = 2.0H +1.1 / -1.4 +1.1 / -1.3

Standard table BK04 BK04


Correction
-4.9 -4.9
Summand
Corrected Glare Indices referring to 2700lm Total Luminous Flux

DIALux 4.9 by DIAL GmbH Page 2

DIALux 4.9 Output Página 2 de 5


DIALux 4.9 Output Página 3 de 5

Project 1
14.04.2011

Operator
Telephone
Fax
e-Mail

Room 1 / Summary

9.60 m
9.10

20 20
20
20 40
40 20
40 60 60 40
20 20 4.80
40 40
20 20
20 20

0.50
0.00
0.00 4.80 9.60 m

Height of Room: 2.800 m, Mounting Height: 2.800 m, Maintenance Values in Lux, Scale 1:124
factor: 0.67

Surface  [%] Eav [lx] Emin [lx] Emax [lx] u0


Workplane / 9.68 2.39 65 0.247
Floor 15 7.82 2.52 32 0.323
Ceiling 50 12 1.49 536 0.124
Walls (4) 72 2.85 1.72 4.39 /

Workplane: UGR Lengthways- Across to luminaire axis


Height: 0.750 m Left Wall 16 16
Grid: 128 x 128 Points Lower Wall 16 16
Boundary Zone: 0.500 m (CIE, SHR = 1.00.)
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.273, Ceiling / Working Plane: 1.193.
Proportion of points with less than 400 lx (for IEQ-7): 100.00%.

Luminaire Parts List

No. Pieces Designation (Correction Factor)  [lm] P [W]


1 1 LEDSC4 00-4339-21-05 VIRGINIA (1.000) 2700 60.0
Total: 2700 60.0

Specific connected load: 0.65 W/m² = 6.72 W/m²/100 lx (Ground area: 92.16 m²)

DIALux 4.9 by DIAL GmbH Page 3

DIALux 4.9 Output Página 3 de 5


DIALux 4.9 Output Página 4 de 5

Project 1
14.04.2011

Operator
Telephone
Fax
e-Mail

Room 1 / Input Protocol

Height of working plane: 0.750 m


4 3
Boundary Zone: 0.500 m

Maintenance factor: 0.67

Height of Room: 2.800 m


Ground area: 92.16 m²

1 2

Surface Rho [%] from ( [m] | [m] ) towards ( [m] | [m] ) Length [m]
Floor 15 / / /
Ceiling 50 / / /
Wall 1 72 ( 0.000 | 0.000 ) ( 9.600 | 0.000 ) 9.600
Wall 2 72 ( 9.600 | 0.000 ) ( 9.600 | 9.600 ) 9.600
Wall 3 72 ( 9.600 | 9.600 ) ( 0.000 | 9.600 ) 9.600
Wall 4 72 ( 0.000 | 9.600 ) ( 0.000 | 0.000 ) 9.600

DIALux 4.9 by DIAL GmbH Page 4

DIALux 4.9 Output Página 4 de 5


DIALux 4.9 Output Página 5 de 5

Project 1
14.04.2011

Operator
Telephone
Fax
e-Mail

Room 1 / Luminaires (coordinates list)

LEDSC4 00-4339-21-05 VIRGINIA


2700 lm, 60.0 W, 1 x 3 x TC-DSE 15W (Correction Factor 1.000).

No. Position [m] Rotation [°]


X Y Z X Y Z
1 4.800 4.800 2.800 0.0 0.0 90.0

DIALux 4.9 by DIAL GmbH Page 5

DIALux 4.9 Output Página 5 de 5