Xerox Color 800/1000 Press Full Width Array Service Training

The document discusses the operation and diagnostic routines of the Xerox Color 800/1000 Press Full Width Array (FWA). It describes how the FWA works, including how the lamps illuminate color patches which are reflected to a CCD array. It also outlines the main diagnostic routines used to calibrate and test the FWA, including dC970 FWA Setup which ensures all components are working correctly.

Uploaded by

a4rfan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
251 views58 pages

Xerox Color 800/1000 Press Full Width Array Service Training

The document discusses the operation and diagnostic routines of the Xerox Color 800/1000 Press Full Width Array (FWA). It describes how the FWA works, including how the lamps illuminate color patches which are reflected to a CCD array. It also outlines the main diagnostic routines used to calibrate and test the FWA, including dC970 FWA Setup which ensures all components are working correctly.

Uploaded by

a4rfan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 58

Xerox Color 800/1000 Press

Full Width Array Service Training


1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Operation Overview

• The FWA DC PWB controls the WR Roll Motor, Lamps, and Fans
through the FWA Power PWB. FWA DC PWB
• When FWA operation begins, the lamps are illuminated. The
system waits for up to three minutes for the lamps to warm up
and provide consistent light.

Lamps

1
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Operation Overview

• Depending on the application of the FWA, the lamps illuminate


one of the calibration strips on the White Reference (WR) Roll or Mirror 2 (two mirrors)
color patches on a test pattern.
• The Light is reflected up, between the lamps, to mirrors that
direct the light to the CCD array.

Mirror 1

2
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Operation Overview
CCD Array
• An adjustable aperture regulates the amount of light entering the
lens. Aperture

• The lens focuses the light onto the CCD Array.

Lens

3
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Operation Overview

• Filters enable the CCD array to sense the light as separate R, G, B


colors. FWA DC PWB

• The CCD array converts the RGB light to analog voltage signals
for each R, G, B color and sends them the FWA Device Controller
PWB.
• The FWA DC PWB converts the analog voltage signals to ten-bit
digital CMYK values.
• Depending on the application, the CMYK values are compared to
the acceptable range of values. If the values are outside the
range, corrections are calculated and sent to the IOT to adjust the
LUTs, ROS profile, or ROS Timing.
CCD

4
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Operation Overview

The FWA must be calibrated before it is used to calibrate the IOT.


The calibration procedure uses the WR Roll tiles as references. A
number of measurements are made on the different reference strips
and the FWA DC PWB uses these measurements to perform the
calibration. After the FWA is calibrated, it can be used to accurately
measure test patterns created by the IOT.
An FWA calibration occurs at the following times:
• It can be manually invoked through the use of a diagnostic
routine.
• It is invoked automatically during press power on, if it has been
approximately two hours after the last automatic calibration.

For example, when the press is powered up first thing in the


morning, it will be more than two hours since the last
automatic calibration, so the press will perform an automatic
calibration at power on. However, if you power the press off
and on within the next two hours, the auto calibration will not
be performed at power on.

5
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Communication
IOT-R
ELEC BOX The view for this diagram is
Ethernet For Download
A CircLink twisted pair cable enables bi- PC UI SYS PWB
from the rear of the machine
directional communication between the IOT
Main PWB, FWA DC PWB and the SYS PWB.
The FWA DC PWB is connected between the DFE I/F MOTHER HT PWBs IOT-L
FSR/INV PWB and PH Core PWB. PWBs

DFE
The FWA is controlled by software on the IOT
ROS
Main PWB. The IOT Main PWB generates
control signals, including when and how the
FWA scans the printed output and when to run IOT MAIN
J767 PWB
calibration routines.
All calculations for the different FWA features
are performed on the FWA DC PWB. When the CircLink
calculations are complete, the data is
communicated to the IOT Main PWB, which FSR/INV
FWA DC PH_CORE MK_XERO MK_DRV
CORE PWB PWB CORE
CORE PWB
then updates the appropriate NVM location. PWB PWB

6
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

The FWA PC UI Diagnostic Software adds new FWA diagnostic


routines to the Image Quality section of the Diagnostics Tool.
• dC970 FWA Setup
• dC971 FWA CTRACS
• dC972 FWA Uniformity
• dC973 Alignment Setup
• dC974 FWA CTRACS Manual Adjustment
• dC975 FWA CTRACS User Target Set

7
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC970 FWA Setup


dC970 FWA Setup is used to calibrate the FWA. It is performed
during the FWA Kit installation. It ensures that all the FWA
components are working correctly and within specification. If
any FWA component is replaced, then dC970 must be
performed to recalibrate the system.
GP18 FWA Setup provides instructions for when to perform
dC970 and the correct sequence for performing the other
diagnostic routines.
The system regularly performs portions of dC970 to maintain
self-calibration. You should not have to perform dC970 just to
run the other FWA Diagnostic routines.
Click to go to GP18 FWA Setup.
Click to go to dC970 FWA Setup.

8
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

Auto Setup
Several check/adjust routines are used to calibrate the FWA and
to calibrate the IOT. These routines can be performed
manually, one at a time, or automatically by selecting Start
Auto Setup.
The Auto Setup routine will described later in his training.

9
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC970 FWA Setup


The first calibration routine is Gain Offset Adjustment.
In this routine, the WR Roll is rotated to the White Reference
Strip. For the Gain measurement, the Lamps are lit and the
system measures the amount of reflectance. As components
age, the amount of reflectance can change. The White
Reference Strip is used as the standard, so if the voltage output
from the CCD array to the FWA DC PWB changes, the FWA DC
PWB compensates to return it to the correct digital value.
For the Offset measurement, the lamps are switched off. This
sets up the input to the FWA DC PWB for black. The Gain and
Offset adjustment sets the FWA to the full range of 0 to 255
when measuring from black to white.

10
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC970 FWA Setup


The Shading Profile Update again uses the White Reference
Strip on the WR Roll. The FWA DC PWB monitors the reading
along the entire length of the strip (inboard - outboard). The
system then compensates for any variations in the sensor
reading.

11
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC970 FWA Setup


The Position Adjustment uses the Registration Tiles on the WR
Roll. The routine uses three different sets of tiles to ensure
correct focus and registration.
The three routines are:
• Lighting Depth
• Focus
• Read Position

12
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC970 FWA Setup


Lighting Depth (or Depth of Field ) uses three sets of three tiles.
The three tiles are staggered so that one is higher, one lower,
and the middle one is flush with the level of the Test Print
Measurement Surface. The lower and upper tiles should
measure the wrong number of pixels because they are too close
or too far away. The middle tile should be the correct depth.

13
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC970 FWA Setup


The Focus routine measures the gray tiles. These tiles are
actually very fine lines. The FWA measures the number of pixels
for each line and for the white space between the lines. The
FWA DC PWB adjusts its threshold for analog-to-digital
conversion to ensure the correct number of pixels are counted.

14
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC970 FWA Setup


The Read Position measures through the Z tiles. The FWA
measures in a line across the Z pattern and determines the
position of the WR Roll by analyzing the relative position where
the sensor crosses the three locations. The location where the
sensor crosses the diagonal line in relation to the sides of the Z
will vary, depending on the position of the WR Roll.

The WR Roll Assembly is adjusted in manufacturing and a


calibration number (used in NVM location 782-822) for the
correct position is located on the side of the WR Roll Assembly.
Only minor changes to this value should be required.

15
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC970 FWA Setup


Sensor Color Calibration uses the Color Tiles on the WR Roll.

When the system is installed, Sensor Color Calibration is run and


Set Correction selected. This establishes the T0 (Time Zero)
values for the FWA Lamp Assembly. When Read is selected,
these T0 values are displayed.

When the routine is run again and Start selected, the tiles are
measured, and the T0n (Time Zero Now) values are displayed.
The T0n values are compared against internal specifications to
determine if the reading passes. Do NOT select Set Correction.

When the FWA Lamp Assembly is replaced, perform Sensor


Color Calibration and after the measurements are made, select
Set Correction. The T0n values are saved as new T0 values for
the FWA Lamp Assembly.

16
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC971 – FWA CTRACS Adjustment


For the FWA CTRACS Adjustment, the press prints test patches
that the FWA reads.

This adjustment is used to adjust the IOT Look-Up Tables (LUT)


so that the printer produces accurate and consistent renditions
of C, M, Y, and K of varying densities and for all used screens.

NOTE: The customer can also perform this routine through a


customer application. The customer application will be described
later in the training.

Click to go to dC971 FWA CTRACS Adjustment.

17
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC971 – FWA CTRACS Adjustment


Under the Main tab, you can select Simple or High Accuracy
modes. With Simple selected, any of the Screens, including All,
can be selected. One set of five test patterns is printed and
measured.

With High Accuracy selected, under Screen, any of the screens


can be selected, but All is not available. The routine will
continue to print sets, measure patches, apply corrections, and
reprint (up to 20 sets), until the measurement meets an IQ
threshold.

Select the Paper Tray. The paper stock can be 8.5 x 11 in. (A4)
or larger. The Paper Type can be coated or uncoated.

The FWA CTRACS Adjustment should be done on each paper


type the customer uses.

NOTE: The High Accuracy Data tab displays the raw data. Use
this only as directed by Second Level Support.

18
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC971 – FWA CTRACS Adjustment Target Location Mark


When Auto Tone Correction is selected, the CTRACS routine generates
target prints containing 24 different density levels for each color (CMYK)
for a total of 96 patches. The target prints contain small location marks
on the outside edges of the patches. The target prints are similar to the
ProCon test pattern.

When a test print is measured, the FWA averages the measurement of a


small area of pixels within each patch. This routine ensures that the
patches on the test prints are read correctly. The FWA reads each patch
and compares the value of the measured patch to the expected value.
When Confirm Print is selected, the CTRACS routine applies the calculated
correction and prints the patches. These prints do not have the target
location marks. Compare this print to the target print to verify that the
image quality is improved. If acceptable, select Set Correction.

Selecting Set Correction applies the correction to the LUT in the press so
that the IOT is color calibrated.

NOTE: This does not calibrate the system. IOT calibration must be
performed first before DFE color calibration.
19
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC972 – FWA Uniformity


The dC972 FWA Uniformity routine corrects inboard –
outboard uniformity (smile correction).

From the Main tab, select the paper tray and the number of
colors in the print engine. The test pattern must be printed on
large paper, 11 x 17 in. (A3) or 12 x 18 in. (SRA3).

Click to go to dC972 FWA Uniformity.

NOTE: With the FWA option, you should not use the dC882
Fast Scan Uniformity Adjustment routine. Use this routine
only as directed by Second Level Support.

20
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC972 – FWA Uniformity


When Start Adjustment is selected, the dC972 routine prints
targets consisting of two pages. One page contains RGB test
patches and the second contains CMYK test patches. The
patches are printed in 60% and 20% density. The test patches
correspond to the Color Tiles on the WR Roll. The FWA reads the
patches for any fast scan (IB-OB) variation.

When Confirm Print is selected, the dC972 routine applies the


calculated corrections and reprints the patches. Examine the
Target Print to determine that the density is uniform. If
acceptable, select Set Correction.

The corrections, if applied, are sent to the IOT where they are
used to change the ROS profile.

21
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC972 – FWA Uniformity


Under the Manual Density Adjustment, you can view the
measured values for each color.

You should run the routine from the Main tab. The Manual
Density Adjust and manual Raw Data should be used only if
directed by Second Level Support.

22
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC973 – Alignment Setup


dC973 Alignment Setup sends large paper - 11 x 17 in. (A3) or
12 x 18 in. (SRA3) through the paper path. The routine
measures all the edges of the paper to locate the paper in the
paper path. Also, the FWA monitors the Decurler Exit Sensor to
establish the timing from the activation of the sensor to the
arrival at the FWA measurement site.

With Paper Corner Position Correction checked, the routine


measures the position and timing of the paper and saves
corrected position values to NVM to ensure the sensor measures
the correct locations.

With Paper Corner Position Correction unchecked, the routine


measures the position and timing of the paper and compares
these values to the current NVM values. No corrections are
made to the NVM values. It only verifies if the current settings
are acceptable.

Click to go to dC973 Alignment Setup.

23
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

dC974 - FWA CTRACS Manual Adjustment and dC975 – FWA


User Target Set
dC974 and dC975 are manual adjustments of the CTRACS
settings. With these routines, each color can be adjusted along
its curve, for the LUT and the Target Set. Serious IQ problems
can be caused if the curves are incorrectly adjusted. These
diagnostic routines should not be used unless directed by
Second Level Support.

The automatic setup, dC971, should properly calibrate the


system LUTs without the use of manual adjustments.

24
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

Manual Setup
The following dC routines are executed at installation or when
replacing the Lamp Assembly, White Reference (WR) Roll
Assembly, or the FWA Assembly in the order listed:

• dC970 FWA Setup - Calibrates Lamp and FWA response


• dC973 Paper Alignment – Calibrates accurate paper
measurement points for the FWA.
• dC972 Uniformity – Corrects density variations in the FS
direction.
• dC971 CTRACS Adjustment – The Customer Tone
Reproduction Automatic Correction System establishes a
lookup table for accurate color reproduction.

25
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

Auto Setup
A Start Auto Setup button is in top right corner of the dC970
window. This routine is used primarily at Installation when the
entire setup procedure must be run.
When Start Auto Setup is selected, the routine performs the
following:
• dC970 FWA Setup
• dC973 Paper Alignment
• dC972 Uniformity
For dC972, the press will print the target and confirmation
prints. The routine will wait for you to accept or reject the
changes.
The Auto Setup routine ends with dC972. You must run dC971
CTRACS manually to complete the setup.

26
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Diagnostic Routines

Auto Setup
If a routine fails while the Auto Setup routine is running, the
routine will stop and the faulted routine window will be
displayed.
Run the routine manually to verify the fault. If the fault is still
present, use the corrective actions if displayed, or use the
service documentation to correct the problem.
Continue the rest of the setup manually.

27
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Technical Key Operator (TKO)


The TKO access is changed with this level of software.
Previously, the TKO opened the Diagnostic Tools and logged on
as TKO. With this software, the TKO selects Logon in the Color
800/1000 Press Home page.

28
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Technical Key Operator (TKO)


In the Logon window, you can logon as Administrator or as
Technical Key Operator (TKO).

The default Password is 54321.

The administrator can change the password of the TKO.

29
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Technical Key Operator (TKO)


After logging in as Technical Key Operator, the Job/System
Status area displays that the system is in Technical Key
Operator Mode and Technical Key Operator is displayed in the
top right corner of the Color 800/1000 Press Home screen.

30
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

When logged on as Administrator or TKO, the Profiles and


System Settings selections appear at the bottom of the window.

Select System Settings.

31
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto TRC and Auto Density Uniformity


There is a new tab in the System Settings window – Full
Width Array.

Under the Full Width Array tab, there are two new customer
routines.

• Automatic TRC (Tone Reproduction Curve) Adjustment


• Automatic Density Uniformity Adjustment

32
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto TRC
The Auto TRC routine performs the same adjustment as dC971
FWA CTRACS Adjustment and updates the IOT LUT to calibrate
the IOT.

As for dC971, either Simplified TRC (Faster) or High Accuracy


TRC (Better Quality) can be selected.

NOTE: Xerox recommends that the customer perform Auto TRC


(Simplified Mode) on a daily basis.

The correction is applied to the selected stock type (coated or


uncoated). When that stock type is selected for a print job, the
correct LUT will be applied.

Select Start to begin the routine.

33
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto TRC
After the target prints are run and measured, you can select
Accept Changes to accept the calculated corrections.

Or you can select Start to print a test pattern with the


corrections applied.

34
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto TRC
If you selected Start, a screen will appear asking to compare the
test pattern with the target print. If it is acceptable, select OK.
If the changes are not acceptable, select Cancel.

35
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto Density Uniformity


The Automatic Density Uniformity routine performs the same
adjustment as dC972 Uniformity and updates the IOT to correct
the ROS profile.

NOTE: The customer should perform the Auto Density


Uniformity routine on an as-needed basis.

Select the Tray and select Start to begin the routine. The
routine runs target prints and measures the IB/OB uniformity.

36
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto Density Uniformity


After the target prints are run and measured, you can select
Accept Changes to accept the calculated corrections.

Or you can select Start to print a test pattern with the


corrections applied.

37
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto Density Uniformity


If you selected Start, a screen will appear asking to compare the
test pattern with the target print. If it is acceptable, select OK.
If the changes are not acceptable, select Cancel.

38
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Image Quality
Also in the System Settings window, the TKO has new selections
under the Image Quality tab.

The TKO can run the Process Control Setup for black, clear,
CMYK, or all stations.

They can also print the halftone Test Print from this window.

NOTE: These selections are not available to the Administrator.

39
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto Alignment
With the FWA option, the printer can now automatically align
the image on the page. A new automatic registration function
is added to the Administrator / TKO applications.

NOTE: Customers should perform Auto Alignment on an as-


needed basis.

NOTE: The Auto Alignment procedure is described in GP 28 Auto


Alignment in the service documentation.

Log on as Administrator or TKO and Profiles appears at the


bottom of the window.

Select Profiles.

40
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto Alignment
The Profiles window displays all the profiles created by the
customer. The registration adjustment is applied only to the
profile that is selected or created. It must be applied to every
stock profile that the customer uses.

Select a profile and Edit to perform the adjustment on an


existing profile; or select New to create a new profile.

41
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto Alignment
In the Profile Properties window, there is a new Auto Alignment
button. Auto Alignment will perform Registration (Position),
Perpendicularity, Skew, and Magnification. Accurately
performing these adjustments will establish correct side-1 / side-
2 registration.

42
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto Alignment
Select the tray in which the stock is located and start the test.

If the same stock is in multiple trays, you have to create


separate profiles and perform the registration adjustment for
each tray.

43
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Auto Alignment
Select the tray in which the stock is located and start the test.
The Auto Alignment adjustment will print several test patterns
with a grid pattern. Side one has a black grid and side two has a
magenta grid. The FWA will read the edges of the sheet and
the lines on the page and determine if correction is required.
Corrections are sent back to the IOT to adjust the ROS timing.

If the image is substantially misregistered, you may have to


perform the registration adjustment series ADJ 7.1 – ADJ 7.6 to
manually correct the registration.

44
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Maintenance
Changes are made to the Maintenance screens to enable the
TKO to service the press.

45
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Consumables
In the Consumables tab, notice that the Drum Cartridges are
removed.

46
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

Service Items
The Maintenance window contains a new tab – Service Items.

The window is divided into three sections: Name, Threshold, and


Counter. The status of serviceable components can quickly be
detected from the list. Any items near the end of their threshold
will have their counter displayed in gray. Items that have
exceeded their threshold will have their counters displayed in
red.

Select Reset to return the HFSI counter to zero.

NOTE: Notice that the Drum Cartridges are located in the HFSI
list.

47
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Xerox Productivity Plus Program

The trained Technical Key Operator (TKO) will now be required


to clean all surfaces of the White Reference Roll, as part of their
on-going maintenance responsibilities. The cleaning procedure
has been added to the Xerographic Trim Procedure in the XPP
Service Manual (Transfer Module Interim Maintenance). The
Xerographic Trim Procedure (REP 9.5) targets the ADC/MOB
Sensor, V-tra 1, 2 and 4 path sensors, and now the FWA White
Reference Roll, which is performed at a specific interval.

48
Xerox Color 800/1000 Press
Full Width Array Service Training
1 Overview | 2 FWA Operation | 3 Kit Installation | 4 Service

2 FWA Operation
Customer Routines

DFE Calibration and Profiling


With the FWA option, DFE calibration and profiling can be
performed if the DFE supports the feature.

Without the FWA option, the procedure is to print the test


patterns and then to manually measure the patches with a hand
spectrophotometer.

With the FWA option, the system recognizes that the press has
an FWA and prints a different test pattern that is read by the
FWA. The system reads all the patches after the operator
initiates the routine.

The service engineer is not required to perform DFE calibration


or profiling. If image quality problems require that a DFE
calibration or profile is needed, ask the customer to perform it,
or call in an analyst to assist the customer.

49
GP 18 FWA Setup Manual Setup Procedure
Purpose 1. Ensure that there are no IQ defects with the system and that the Xerographic subsystem is operat-
ing properly. (e.g., perform dC938 ProCon).
The purpose of this procedure is to calibrate the In Full Width Array (FWA) in order that the press repro-
Before performing this routine at installation, ensure that the WR Roll tiles (PL 20.6) and the
duces accurate print files.
Lamp Window ([PL 20.5]) are clean.
This procedure must be performed in its entirety at installation or when replacing the Lamp Assembly, • Clean the WR Roll Assembly ([PL 20.6]) with a dry lint-free cloth.
White Reference Roll Assembly or the FWA Assembly. The following dC routines are executed during • Clean the FWA Lamp Assembly Window ([PL 20.5]) using Lens Cleaner to dampen a lint-
the setup in the order listed: free cloth.
2. The first step in the FWA Setup is to run dC970 FWA Setup. The routine consists of six separate
• dC970 FWA Setup - Calibrates Lamp and FWA response steps:
• dC973 FWA Alignment Setup – Calibrates accurate paper measurement points for the FWA. • Gain Offset Adjustment – This step calibrates scanner response to Lamp intensity. If the
• dC972 FWA Uniformity – Corrects density variations in the FS direction. results are NG, instructions will be displayed to resolve the error.
• dC971 FWA CTRACS – The Customer Tone Reproduction Automatic Correction System estab- • Shading Profile – This step sets correction values in the scanner to compensate for varia-
lishes a lookup table for accurate color reproduction. tions in the scanner CCD light response.
Automatic Setup Procedure • Position Adjustment – This step calibrates the read position, focal point and depth of field
for the scanner. If the results are NG, instructions will be displayed to resolve the error.
1. Ensure that there are no IQ defects with the system and that the Xerographic subsystem is operat-
ing properly. (e.g., perform dC938 ProCon). • Sensor Color Calibration – This step uses the color tiles on the White Reference Roll to
Before performing this routine at installation, ensure that the WR Roll tiles (PL 20.6) and the record the scanner response to the color tiles at FWA installation.
Lamp Window ([PL 20.5]) are clean. • Auto Shading Adjustment – This adjustment is currently grayed out and not used in this
• Clean the WR Roll Assembly ([PL 20.6]) with a dry lint-free cloth. product.

• Clean the FWA Lamp Assembly Window ([PL 20.5]) using Lens Cleaner to dampen a lint- Refer to dC970 and run the routine. Return here when finished.
free cloth. 3. The second step is to run dC973 Alignment Setup. The routine feeds ll x 17 in. (A3) or 12 x 18 in.
(SRA3) paper through the scanner area and the 4 corner positions are measured to establish where
2. Open dC970 FWA Setup.
the exact paper position is located in the scanner area.
3. Select Start Auto Setup.
The Auto Setup will perform the sequence of dC routines in the correct order. NOTE: Only run the Paper Measurement Check and select a quantity of at least five (5) to get the
average position. Do not run the Alignment Setup.
4. If a routine fails, Auto Setup will stop at that routine.
a. Perform the failed routine manually. Refer to dC973 FWA Alignment Setup and run the routine. Return here when finished.
b. Perform corrective actions as required to pass the routine. 4. The third step is to run dC972 FWA Uniformity. This routine requires ll x 17 in. (A3) or larger
c. After the routine passes, refer to the Manual Setup Procedure and continue the setup from the paper. The routine corrects density variations across the FS Direction (Smile Correction).
current routine. Refer to dC972 and run the routine. Return here when finished.
5. If all routines pass, the Auto Setup will continue to dC972 FWA Uniformity. 5. The final step is to run dC971 FWA CTRACS. This routine establishes the Customer TRC for
a. The routine will print the target and confirmation prints. accurate color reproduction.
b. Verify that the confirmation prints are acceptable by comparing the sides of the prints to the Refer to dC971 FWA CTRACS and run the routine.
middle. 6. Exit Diagnostics.
c. If the confirmation prints are not acceptable, perform the corrective actions and repeat the 7. Perform registration setup.
routine. • If you are performing a machine installation, perform the registration setup series ADJ 7.1 -
d. When the confirmation prints are acceptable, select OK. ADJ 7.6.
6. Refer to dC971 FWA CTRACS and perform the procedure. • If you are perfroming a kit installation of the the FWA option, or are repairing the FWA, per-
7. Exit Diagnostics. form GP 28 Auto Alignment
8. Perform registration setup. 8. Restore the press to normal operating condition and check for correct operation and print quality.
• If you are performing a machine installation, perform the registration setup series ADJ 7.1 -
ADJ 7.6. Click here to go back to the training course.
• If you are perfroming a kit installation of the the FWA option, or are repairing the FWA, per-
form GP 28 Auto Alignment
9. Restore the press to normal operating condition and check for correct operation and print quality.

General Procedures 07/2010 Supersedes 705P01282


GP 18 6-44 Color 800/1000 Press Service Documentation
dC970 FWA Setup
Purpose
This procedure calibrates the FWA to lamp intensity, light variations in the CCD, paper read
position, and the color tiles on the White Reference (WR) Roll Assembly.

NOTE: Do Not perform this adjustment unless directed from GP 18 FWA Setup Procedure.

Prerequisites
Before performing this routine at installation, ensure that the WR Roll tiles (PL 20.6) and the
Lamp Window (PL 20.5) are clean.

Ensure that there are no IQ defects with the systm and that the Xerographic subsystem is
operating properly. (e.g., perform dC938 ProCon).

Procedure
1. Open the Gain Offset Tab. If the current NVM values are not displayed in the CUR column
(question marks) click on Read. The current NVM values will display (Figure 1).

NOTE: At installation, there will not be any values assigned.

Figure 2 Bar Code Label

3. Click on Start. When the routine ends, the Gain and Offset values will be displayed in the
Adj Column (Figure 3)

Figure 1 Gain Offset

2. Ensure that the value displayed in the [782-822] location matches the value written on the
Bar Code Label located on the right side of the WR Assembly frame. (open the Exit
Transport and lift the assembly to observe the label) (Figure 2). If the value is not dis-
played, type the correct value in the field and click Write.

Initial Issue 01/09 General Procedures


Cham Service Documentation 6-225 dC970
Figure 4 Shading Profile Update
Figure 3 Read Values
6. Click on the Position Adjustment Tab (Figure 5).
4. If new values are within specification, Click on Set Correction.

NOTE: If NG is displayed, instructions on how to resolve the issue will be displayed. Fol-
low the instructions in the order listed.

5. Click on the Shading Profile Update tab and click on Start. When the routine finishes,
click on Set Correction (Figure 4).

Figure 5 Position Adjustment

General Procedures 01/09 Initial Issue


dC970 6-226 Cham Service Documentation
7. Click on Start. The routine will run and the values will display (Figure 6).

NOTE: If NG is displayed, follow the displayed instructions to resolve the issue.

Figure 7 Sensor Color Calibration

9. Click Start. When the routine finishes, the current values are displayed (Figure 8).
Figure 6 Position Adjustment

8. Click on the Sensor Color Calibration tab. The Time 0 values are displayed. (Figure 7)

Figure 8 Sensor Color Values

Initial Issue 01/09 General Procedures


Cham Service Documentation 6-227 dC970
10. Click Set Correction. The dC routine is complete. dC971 FWA CTRACS Adjustment
Click here to go back to the training course.
Purpose
This procedure builds an accurate color reproduction Lookup Table.

NOTE: This procedure is the same as the Admin / TKO Automatic TRC (Tone Reproduction
Curve) Adjustment under System Settings > Full Width Array.

Procedure
1. From the Main tab, select the Auto Tone Correction Mode (Figure 1)
• If resolving a problem with the FWA or during installation of the FWA, select High
Accuracy
• For routine setups, select Simple.

Figure 1 dC971 FWA CTRACS Adjustment window

2. Select the appropriate screen or All. If High Accuracy is selected, All is disabled.
3. Select the Tray and verify the paper loaded in the tray matches the Paper Type selection
(coated or uncoated).
4. Click on Auto Tone Correction. The routine runs and at least 5 target prints are delivered
to the output.
5. Click on Confirm Print. A confirmation print will be delivered to the output.

General Procedures 01/09 Initial Issue


dC971 6-228 Cham Service Documentation
6. If the confirmation print compares favorably to the target prints, click on Set Correction. dC972 FWA Uniformity
7. The routine is complete.
Purpose
Click here to go back to the training course. This procedure corrects density variations in the fast scan direction.

NOTE: This procedure is the same as the Admin / TKO Automatic Density Uniformity Adjust-
ment under System Settings > Full Width Array.

Procedure
Main
1. From the Main tab, select the paper tray containing large paper (11x17 in. (A3) or 12x18
in. (SRA3)) (Figure 1)

Figure 1 Main

2. Click Start Adjustment. The routine will run and print 2 test prints.
3. Click on Confirm Print. Two confirmation prints will be run.
4. Compare the color of the prints from edge to edge, and from the edges to the middle. If
the check is satisfactory, click on Set Correction.
5. The routine is complete.

Manual Density Adjust

NOTE: Use the Manual Density Adjust only when instructed by second level support.

1. From the Manual Density tab, select the paper tray containing large paper (11x17 in. (A3)
or 12x18 in. (SRA3)) (Figure 2).

Initial Issue 01/09 General Procedures


Cham Service Documentation 6-229 dC971
Figure 2 Screen Setup Figure 3 Test Printing

2. Click Start Current Print. The routine will run and print 2 prints with the current ROS 3. Click on Confirm Print. Two confirmation prints will be run.
Smile Correction Data settings (Figure 3). 4. Compare the color of the prints from edge to edge, and from the edges to the middle. If
the check is satisfactory, click on Set Correction..
5. The routine is complete.

Click here to go back to the training course.

General Procedures 01/09 Initial Issue


dC972, dC973 6-230 Cham Service Documentation
dC973 FWA Alignment Setup dC974 FWA CTRACS Manual Adjustment
Purpose Purpose
This procedure establishes accurate paper measurement points for the FWA. This procedure is used to manually change the CTRACS Lookup Table.

NOTE: Do Not perform this adjustment unless directed from GP 18 FWA Setup Procedure. NOTE: Do Not perform this adjustment unless directed by Second Level Support.

Procedure Procedure
1. From the Paper Measurement tab, select a quantity of at least five (5) and the paper tray 1. Select the desired Color Mode, Print Count and Paper Tray. (Figure 1).
containing11 x 17 in. (A3) or 12 x 18 in. (SRA3) paper (Figure 1).

Figure 1 CTRACS Manual Adjustment


Figure 1 Screen Setup
2. Click Check PG. The routine will run and ProCon test patterns are printed. The current
2. Ensure that the Paper Corner Position Correction box is checked (selected). LUT values are then displayed.
3. Click Paper Check. The routine will run and blank sheets will feed. 3. Changes can then be made to the ADJ column.
4. The table shows the numbers used to correct the paper position and if the judgment was 4. Click on Update to make the changes.
OK. 5. Click on Save to save the changes.
5. Uncheck the Paper Corner Position Correction Box and run Paper Check again. More
blank sheets will be sent through the press.
6. The routine will check the position using the corrected values. OK will display and the rou-
tine is complete.

Click here to go back to the training course.

Initial Issue 01/09 General Procedures


Cham Service Documentation 6-231 dC974, dC975
dC975 FWA CTRACS User Target Set NVM Access Tool
Purpose Purpose
This procedure is used to manually change the CTRACS Target. The purpose of the NVM Access Tool is to allow the input and gathering of specific scripts.

NOTE: Do Not perform this adjustment unless directed by Second Level Support. Procedure
Procedure 1. Enter the Service Diagnostics Mode, refer to: dC100.
2. Click NVM Access on the Service Entry window, then click Script or use the DC Quick
1. From the Target Set tab, select the desired Color Mode, Print Count and Paper Tray.
pull-down to open the NVM Access Tool window. (Figure 1)
(Figure 1).

Figure 1 CTRACS Target Manual Change


Figure 1 NVM Access Tool
2. Click Start. The routine will run and ProCon test patterns are printed. The current LUT
values are then displayed. 3. Follow the instructions that sent you to this procedure.
3. Changes can then be made to the target value in the Target column.
4. Click on Save to save the changes.

Click here to go back to the training course.

General Procedures 01/09 Initial Issue


NVM Access Tool, Machine Faults 6-232 Cham Service Documentation