0% found this document useful (0 votes)
29 views

Assasuni 1

Md. Arif Hossain *DS: Disturbed Sample Bore Hole Terminated at 60 ft. Remarks: Ground Water Table at 2'-1" 6

Uploaded by

Mehedi
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views

Assasuni 1

Md. Arif Hossain *DS: Disturbed Sample Bore Hole Terminated at 60 ft. Remarks: Ground Water Table at 2'-1" 6

Uploaded by

Mehedi
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Client: Executive Engineer, DPHE, Satkhira.

Contacter Name: Sonex International. Package No: Wash-W-135. Tender Id No: 504689.
Project: “Construction of Rural Pipe Water Supply Scheme Bisoure Village Anulia Union at
Assasuni Upazila In Satkhira District Under Water Supply Sanitation And Hygiene WASH
Project”, Thana:-Assasuni, Dist:-Satkhira.
BEARING CAPACITIES OF THE SHALLOW FOUNDATION FROM
FIELDAND LABORATORY TEST (F.S=2.50)

BORE Depth Field Cohesion Bearing Capacity(Tsf) Soil Type


HOLE in Ft SPT Kg/cm2
Square Footing Continuous
Footing
4 5 0.313 0.983 0.775 S.C.G

7 8 - 1.574 1.240 C.S.T.S.G

BH-1 10 6 - 1.180 0.930 C.S.T.S.G

15 7 - 1.377 1.085 C.S.T.S.G

20 8 - 1.574 1.240 C.S.T.S.G

4 6 - 1.180 0.930 C.S.T.S.G

7 9 - 1.770 1.395 C.S.T.S.G

BH-2 10 7 - 1.377 1.085 C.S.T.S.G

15 6 - 1.180 0.930 C.S.T.S.G

20 9 - 1.770 1.395 C.S.T.S.G

*Soil Type: - Silty Clay Gray= ( S.C.G), Clayey Silt Gray= (C.S.G), Clayey Silt Trace Sand Gray=
(C.S.T.S.G), Clayey Silt Little Sand Gray= (C.S.L.S.G).

Note:
1. All Bearing Capacities present here are ultimate bearing capacity considering FS=2.50
2. The bearing capacity Factors Have been taken from Terzaghl’s Bearing Capacity Factor Table.
3. The derived values are approximate, structural /foundation engineer is free from any obligation to use these values
He / she can refine / calculate, taking the soil parameters obtained from field & lab test.
4. Ground water level was considered at Gl.
5. Inclination factor, ground factor & base factors have been considered as 1 in calculation of bearing capacity
equation.
6. General Shear Condition considered with conservative angle of friction.
Based on the soil investigation report

Recommended foundation length is…………………………

1
8. Corrected SPT Values

BH1
Depth (ft)
N' N
4 5 5

7 8 8

10 6 6

15 7 7

20 8 8

25 11 11

30 14 14

35 13 13

40 15 15

45 18 17

50 20 18

55 21 18

60 24 20

BH2
Depth (ft)
N' N
4 6 6

7 9 9

10 7 7

15 6 6

20 9 9

25 10 10

30 13 13

35 15 15

40 14 14

45 15 15

50 18 17

55 20 18

60 23 19

2
9. Physical and Engineering properties of Soil
Test results:
Table Physical and Engineering properties of Soil
Bore Hole No: 01
Liquid Plastic Limit Plasticity Specific Gravity Sand
Depth (%)
(ft) Limit (wL) (wp) Index (PI) (Gs)

4 42.68 29.25 13.40 2.73

10 2.70

20 2.70

30 2.69

40 2.68 55

50 2.67 60

60 2.67 69

Bore Hole No: 02


Liquid Plastic Limit Plasticity Specific Gravity Sand
Depth (%)
(ft) Limit (wL) (wp) Index (PI) (Gs)

4 37.56 28.29 9.27 2.71

7 35.59 28.21 7.38 2.70

15 2.71

25 2.69

35 2.68 53

45 2.68 56

55 2.67 64

3
10. Conclusions And Recommendations:
10.1 Conclusions:
The Soil Investigation Work For The “Construction of Rural Pipe Water Supply Scheme
Bisoure Village Anulia Union at Assasuni Upazila In Satkhira District Under Water Supply
Sanitation And Hygiene WASH Project”, Thana:-Assasuni, Dist:-Satkhira.

Two bore holes were drilled up to the maximum depth of 60 ft. from the existing ground level. On
the basis of the information of the investigated site the following conclusions may drawn:

The bearing capacity of the sub-soil of shallow foundation at normal foundation level is Medium.
On the basis of the field and laboratory information, foundation may be suitable.

10.2 Recommendations:
Based on the above conclusions the following recommendations are suggested for the
constructions of the proposed sites.
For the construction of low rise building up to 4-storied shallow foundation may be used.
However the consultant or design engineer should take any alternative decision about the type,
depth and dimension of foundation.

4
11. SITE PLAN
ORBIT SOIL & SURVEY
The Plan Shows the Locations of Bore Hole Points

Project Name & Location: - Construction of Rural Pipe Water Supply Scheme Bisoure
Village Anulia Union at Assasuni Upazila In Satkhira District Under Water Supply
Sanitation And Hygiene WASH Project”, Thana:-Assasuni, Dist:-Satkhira.

Client: Executive Engineer, DPHE, Satkhira.

5
12. BORE LOG
ORBIT SOIL & SURVEY
Bore Hole No: 01 Water Table:2’-1’’ Date: 08.07.2021
Project Name & Location: - Construction of Rural Pipe Water Supply Scheme Bisoure Village
Anulia Union at Assasuni Upazila In Satkhira District Under Water Supply Sanitation And
Hygiene WASH Project”, Thana:-Assasuni, Dist:-Satkhira.

Client: Executive Engineer, DPHE, Satkhira.


SPT Curve
Strata Samp
Depth No of Bore SPT (Blow Number)
le
(ft) (Sam) Encountered Log Value
4 8 12 16 20 24 28 32 DS *
4 D-1 Silty Caly- Gray 5 √

7 D-2 8 √

10 D-3 Clayey Silt Trace 6 √


Sand- Gray
15 D-3 7 √

20 D-5 8 √

25 D-6 11 √

30 D-7 Clayey Silt Little 14 √


Sand- Gray
35 D-8 13 √

40 D-9 √
15

45 D-10 18 √
50 D-11 Silty Sand-Gray √
20

55 D-12 21 √

60 D-13 24 √

CHECKED BY:

6
ORBIT SOIL & SURVEY
Bore Hole No: 02 Water Table:2’-1’’ Date: 08.07.2021
Project Name & Location: - Construction of Rural Pipe Water Supply Scheme Bisoure Village
Anulia Union at Assasuni Upazila In Satkhira District Under Water Supply Sanitation And
Hygiene WASH Project”, Thana:-Assasuni, Dist:-Satkhira.

Client: Executive Engineer, DPHE, Satkhira.


SPT Curve
Strata Samp
Depth No of Bore SPT (Blow Number)
le
(ft) (Sam) Encountered Log Value
4 8 12 16 20 24 28 32 DS *
4 D-1 6 √

7 D-2 9 √

10 D-3 Clayey Silt Trace √


7
Sand- Gray
15 D-3 6 √

20 D-5 9 √

25 D-6 Clayey Silt Little 10 √


Sand- Gray
30 D-7 13 √

35 D-8 15 √

40 D-9 √
14

45 D-10 15 √
50 D-11 Silty Sand-Gray √
18

55 D-12 20 √

60 D-13 23 √

CHECKED BY: