Method Statement For Installation of Grills Diffusers Disc Valves and Louvers
Method Statement For Installation of Grills Diffusers Disc Valves and Louvers
PROJECT NAME
REVISION RECORD
This cover page is a record of all revisions of the document identified above by number and title. All previous cover pages are
hereby superseded and are to be destroyed.
Rev. No. Date By Chkd. Approvals Description and Page Numbers of Revisions
CONTENTS
1.0 PURPOSE
2.0 SCOPE
3.0 REFERENCES
4.0 DEFINITIONS
5.0 RESPONSIBILITIES
6.0 EQUIPMENTS
7.0 PROCEDURE
PROJECT NAME
TITLE Ref. No. :
METHOD STATEMENT FOR REV. No. 0
INSTALLATION OF GRILLES, DIFFUSERS, LOUVERS & DISC VALVES Date :
Page 3 of 11
8.0 ATTACHMENTS
1.0 PURPOSE
This method statement is applicable for the Installation of Grilles, Diffusers, and Louvers & Disc
Valves for the project as mentioned in the Specifications & Approved Shop Drawings.
2.0 SCOPE
This method Statement shall cover the Supply & Installation of Grilles, Diffusers Louvers &
Disc Valves in line with project requirements as indicated in the Approved Shop Drawings,
specifications & manufacturer’s instructions.
3.0 REFERENCE
4.0 DEFINITIONS
5.0 RESPONSIBILITIES:
Responsibilities for ensuring that the steps in this procedure shall be carried out are specified at
relevant steps in the procedure:
Project Manager
Construction manager
QA/QC Engineer
Site Engineer
HSE officer
SK
The work progress shall be carried out as per planned program and all the equipment’s required
to execute the works shall be available and in good condition as per project planned.
Specific attention is paid to all safety measures and quality control in coordination with Safety
Engineer and QA/QC Engineer and in line with PSP and PQP.
The method of statement to the system shall be implemented according to the Consultant project
PROJECT NAME
TITLE Ref. No. :
METHOD STATEMENT FOR REV. No. 0
INSTALLATION OF GRILLES, DIFFUSERS, LOUVERS & DISC VALVES Date :
Page 5 of 11
The implementation of all safety measures in accordance with the HSE plan and that the whole
work force is aware of its proper implementation.
The implementation of safety measures is adequate to maintain a safe working environment on
the work activity.
Inspection of all the site activities and training personnel in accident prevention and its proper
PROJECT NAME
TITLE Ref. No. :
METHOD STATEMENT FOR REV. No. 0
INSTALLATION OF GRILLES, DIFFUSERS, LOUVERS & DISC VALVES Date :
Page 6 of 11
Responsible for overall Store operations in making sure to store the material delivery to the site and
keep it in suitable area that will keep the material in safe from rusty and damage.
One who will acknowledge the receiving of materials at site in coordination with QA/QC &
concerned Engineer.
6.0 EQUIPMENTS
Work Sequence/Procedure
for Grilles, Diffusers, Louvers & Disc Valves to be inspected upon receipt & approved by the
engineer prior in proceeding with the installation through MIR. Any discrepancies,
damages etc., should be reported to the supplier for rectification or replacement & to be
removed from site immediately.
All construction/inspection/testing works shall be carried out in accordance with the
specifications & to be done by qualified Mechanical Engineers and shall be checked and
approved by MEP Subcontractor Construction Manager along with QA/QC Engineer.
Contractor has to clarify the procedure for material delivery to the site through consultant
Engineer at site.
Grilles, Diffusers, Louvers & Disc Valves are normally shipped & despatch for goods
condition and carefully loaded in containers with crating / boxing/ wrapped with plastics.
Hence, in case of transit damage, supplier must be informed immediately.
Special care must be taken to ensure that units are offloaded from containers. Rough
handling can result in damage to the materials.
Use appropriate type of vehicles in transporting the units and that they are protected
against mechanical & weather damage.
All the received units shall be checked & inspected to ensure that it is complying with the
approved material submittals prior to site storage.
To ensure that deterioration of the Grilles, Diffusers, Louvers & Disc Valves does not occur
during storage, it is recommended to store the equipment in sheltered conditions that are
protected from weather elements and accidental damage.
Grilles, Diffusers, Louvers & Disc Valves shall be protected with plastic/ tarpaulin or shall not
be removed from the shipping package unless otherwise instructed to do so.
Avoid any mechanical shocks and strokes during handling operations.
All packages for the equipment reaching the site shall be identified as per package list.
7.4 Sequence of Installation for the Grilles, Diffusers, Louvers & Disc Valves
7.4.1 Safety
All site safety rules & regulations shall be complied with.
Supervisors will deliver tool box talks, relevant to these activities to all operatives involved in
the installation and shall be recorded.
All operatives will be equipped with minimum personnel protective equipment; hard hat,
PROJECT NAME
TITLE Ref. No. :
METHOD STATEMENT FOR REV. No. 0
INSTALLATION OF GRILLES, DIFFUSERS, LOUVERS & DISC VALVES Date :
Page 8 of 11
7.4.3 General Installation Procedure for Grilles, Diffusers, Louvers & Disc Valves
Ensure plenum or terminal boxes openings are compatible for Grilles, Diffusers, and
Louvers & Disc Valves to be installed.
Ensure that plenums are correctly acoustically lined.
Install sub-frame in the duct opening as manufacturer’s recommendation and ensure that
Grilles, Diffusers, Louvers & Disc Valves shall be installed correctly as per the direction of
PROJECT NAME
TITLE Ref. No. :
METHOD STATEMENT FOR REV. No. 0
INSTALLATION OF GRILLES, DIFFUSERS, LOUVERS & DISC VALVES Date :
Page 9 of 11
flow.
Prepare Grilles, Diffusers, Louvers & Disc Valves by installing sealing material to the
internal side of the mating flange, carefully locate Grilles, Diffusers, Louvers & Disc
Valves’ into sub-frame and locate locking screws and tighten until correct level and the
alignment is attached.
Make sure that screws should be fixed into a metal/ wooden frame which sits in counter
sunked holes through border.
If the aperture is in masonry, the hole locations should be marked, then drilled and plugged
to give more positive fixing.
Concealed rear bracket fixing is for use when a hidden fixing is required but the installation
prohibits the use of clip fixing.
For fixing of Grilles, Diffusers, Louvers & Disc Valves without dampers, the Grilles,
perforated, 4 way Diffusers, and Louvers & Disc Valves are positioned into opening with
metal/ wooden frame screws are fixed through the brackets fixed into the stack of Grilles,
Diffusers, Louvers & Disc Valves to the frame holes.
For Grilles, Diffusers, Louvers & Disc Valves with dampers, the dampers can be fixed with
Grilles, Diffusers, Louvers & Disc Valves border by clip or rivets and damper is fixed by
screwing to the duct opening. Otherwise the damper alone can be directly screwed to the
duct chute.
After final alignment, carefully tighten the Grilles, Diffusers, Louvers & Disc Valves’ until
airtightness is achieved.
Ensure that all Grilles, Diffusers, Louvers & Disc Valves are left in closed position and
protection shall be provided until handing over.
Ensure that each installation of Grilles, Diffusers, Louvers & Disc Valves is undamaged,
clean and screwed tight prior to inspection.
After all installation has been done, raise immediate inspection for approval.
8.1. ATTACHMENTS