Final Year Project 2 Thermoelectric Air Cooling For Car Dr. Khairul Habib
Final Year Project 2 Thermoelectric Air Cooling For Car Dr. Khairul Habib
FINAL REPORT
14385
MECHANICAL ENGINEERING
SEP 2013
0
CERTIFICATION OF APPROVAL
Thermoelectric Cooling For Cars
by
Kalidasan A/L Palanisammy
A project dissertation submitted to the
Mechanical Engineering Programme
Universiti Teknologi PETRONAS
in partial fulfilment of the requirement for the
BACHELOR OF ENGINEERING (Hons)
(MECHANICAL ENGINEERING)
Approved by,
_____________________
Dr. Khairul Habib
1
CERTIFICATION OF ORIGINALITY
This is to certify that I am responsible for the work submitted in this project, that the original
work is my own except as specified in the references and acknowledgements, and that the
original work contained herein have not been undertaken or done by unspecified sources or
persons.
_______________________________
2
TABLE OF CONTENTS . . . . . . . 1
CHAPTER 1: Introduction . . . . . . . 2
1.1 Background History . . . . . . 2
1.2 Problem Statement . . . . . . 4
1.3 Objectives . . . . . . . . 5
1.4 Project Scope . . . . . . . 6
CHAPTER 2: Literature Review . . . . . . 7
2.1 Introduction . . . . . . . 7
2.2 Thermoelectric Cooler . . . . . 7
CHAPTER 3: Methodology . . . . . . . 13
3.1 Flow Chart . . . . . . . 13
3.2 Concept Modeling Design . . . . . 13
3.2.1 Design of Parts . . . . . . 14
CHAPTER 4: Project Scope . . . . . . 15
4.1 sizing and designing of the cooling system. . . . 15
4.2 proposed approach and method implemented. . . . 15
4.3 Thermoelectric module . . . . . . 17
4.4 parameters of a thermoelectric module. . . . . 18
4.5 cold side temperatures . . . . . . 19
4.6 temperature difference. . . . . . . 20
4.7 cooling load. . . . . . . . 21
4.8 thermoelectric assembly-heats sinks. . . . . 21
4.9 coefficient of performance. . . . . . 23
4.9.1 power supply and temperature control. . . . . 23
Chapter 5: Design of the project. . . . . . . 24
5.1 Thermoelectric cooling for car design. . . . . 24
5.2 TEC arrangement. . . . . . . . 25
Chapter 6: results and calculations. . . . . . 26
6.1 computation of cooling power. . . . . . 26
6.2 TEC selection. . . . . . . . 26
6.3 selection of heat sink. . . . . . . 27
6.4 results of temperature difference. . . . . . 38
Chapter 7: conclusion and further works. . . . . . 32
7.1 conclusions. . . . . . . . 32
7.2 further works. . . . . . . . 33
References . . . . . . . . . 34-36
Appendix. . . . . . . . . . 37- 44
3
CHAPTER 1
INTRODUCTION
4
The peltier module (Figure 1) was discovered by a French watchmaker during
the 19th century. It is described as a solid state method of heat transfer generated
primarily through the use of dissimilar semiconductor material (P-type and N-type) .
Previously, thermoelectric devices was used in for medical devices , sensor technology ,
cooling integrated circuits . The peltier module usually rated according to its capacity on
heat removal, waste heat and maximum system temperature difference for a specified
DC voltage and applied current. Another important characteristic of peltier module is the
polarity of the heat removal changes when the direction of applied current changes, thus
it is potential to cool or warm an object within same configuration, with respect to the
polarity of the current.
When considering peltier cooling with copper or aluminum heat sinks, of course
it will cost in high price for the fabrication of the prototype but since this manner of
cooling could overcome some disadvantages of existing compressor-based cooling, it is
still worth of the price. By taking all these into consideration, a detailed analysis on the
selection of peltier module and heat sinks will be conducted in this project. The design
of the prototype will be based on air-to-air or liquid-to-air thermo-cooling since the
target is to cool down the interior air.
5
1.2 Problem Statement(s)
When the car is parked during hot days and existing car HVAC system is not
running, the exceeding car’s interior temperature causes discomfort for the car users.
Other than this, the existing HVAC system possesses some disadvantages in its
application such as pollution and frequent maintenance . When considering
thermoelectric cooling, the prototype design should be efficient in the heat removal
performance by the attachment of heat sinks that bring very minimal thermal resistance.
The failure of these mechanism would result in increase of peltier’s system temperature
difference which reduces the heat pumping capacity and contribute to overall failure of
the thermoelectric device.
The new HVAC system using thermoelectric couple which shall
overcome all the Disadvantages of existing HVAC system. If this system comes in
present HVAC system, then revolution will occur in the automotive sector. With
population and pollution increasing at an alarming rate TEC (thermoelectric couple)
system have come to rescue as these are environment friendly, compact and affordable.
Conventional compressor run cooling devices have many drawbacks pertaining to
energy efficiency and the use of CFC refrigerants. Both these factors indirectly point to
the impending scenario of global warming. As Most of the electricity generation relies
on the coal power plants, which add greenhouse gases to the atmosphere is the major
cause of global warming. Although researches are going on, better alternatives for the
CFC Refrigerants is still on the hunt. So instead of using conventional air conditioning
systems, other products which can efficiently cool a person are to be devised. By using
other efficient cooling mechanisms we can save the Electricity bills and also control the
greenhouse gases that are currently released into the atmosphere. Although
Thermoelectric (TE) property was discovered about two centuries ago thermoelectric
devices have only been commercialized during recent years. The applications of TE vary
from small refrigerators and Electronics package cooling to Avionic instrumentation
illumination control and thermal imaging cameras. Lately a dramatic increase in the
6
applications of TE coolers in the industry has been observed. It includes water Chillers,
cold plates, portable insulin coolers, portable beverage containers and etc.
1.3 Objective(s)
It is important to acknowledge the important aspects of the project and the end
result of the project. Thus, it is important to clearly state and recognized the objective of
a project. Throughout this project, these are the objectives that will enlighten in this
thesis;
To study critically existing HVAC system for its advantage and disadvantages.
To explore various technological option to replace existing HVAC system.
To study TEC as a substitute for present HVAC system which will overcomes
the all demerits of present HVAC system.
To fabricate working model of HVAC using TEC.
To test HVAC using TEC for its effectiveness, efficiency, environment
friendliness, comfort and convenience
1.4 Project Scope
7
Size –Present HVAC system required very large space in the engine compartment and
dashboard.
Delicate system –if any component fails to perform well then the whole HVAC system
will either not function properly or not function at all.
The project scope involves the following elements
Sizing and Designing of the cooling system
1. Selection of the TECs
2. Selection of Fans and Heat sinks
3. DC power supply design with temperature control.
4. Prototype Assembly and Fabrication.
5. Temperature measurements for testing.
6. Power supply testing and troubleshooting.
8
CHAPTER 2
LITERATURE REVIEW
2.1 Introduction
The literature review of this project comprises from the journal on the internet,
paper proceedings and research, books and lectures. The literature review is done to
investigate cases of the projects that may arise to overcome it. The literature review
gives a great knowledge on the fundamentals of the project. Among the reviewed project
is about the peltier technology in cooling and heating in the industry and how the heat
sinks and thermo-electric module interacts to cool down the external interfering air.
Among the things that given consideration is the flow rate of coolant by the pump to the
liquid radiator and the required heat sink resistance as well as its dimensions. Apart from
this a few experiments on the temperature rise over time in car cabin was analyzed as a
preparation to run the data collection experiment.
9
schematic of a single thermocouple which consists of one n and one p-type
semiconductor material, also known as a thermo-element with its operating principle is
shown in Figure 2.2. In the n and p type semiconductors there exist excess electrons and
holes respectively. With the electric polarity shown in Figure 2.2, electrons in p and n-
type material flow from bottom to top and from top to bottom respectively, thus
resulting in a clockwise electron flow or counter clockwise current flow through this
circuit. Heat is absorbed at the top and released at the bottom of the schematic shown in
Figure 2.2. If the polarity is changed, the hot and cold junction as well as the heat
absorption and rejection will interchange. There are three important thermoelectric
effects that have been known since the nineteenth century: (i) Seebeck effect, (ii) Peltier
effect and (iii) Thomson effect. Seebeck in 1821 discovered that, when a temperature
difference is maintained at the two junctions of a thermocouple composed of two
dissimilar conductors, a voltage is generated at the two terminals of the thermocouple.
10
Figure 2.2 Schematic of thermoelectric module operation.
12
the required hot side thermal resistance. The empirical relation, however, was specific to
the TEC module considered and was obtained from the curve fit to the experimental
data. The prediction of performance of a TEC based system by Taylor and Solbrekken
(2008) and Zhang et al. (2009) was found to be in reasonable agreement with
experiments. Taylor and Solbrekken (2008) used temperature dependent thermo-element
material properties in their model to predict chip temperature at a fixed heat load with a
fixed hot side thermal resistance while Zhang et al. (2009) considered temperature
independent properties to minimize chip temperature at fixed heat load and to maximize
heat dissipation from chip at fixed chip temperature both at a fixed ambient temperature.
Use of temperature dependent properties resulted in better agreement compared to the
temperature independent properties (Taylor and Solbrekken, 2008). Thomson effect was
neglected in these studies considering its small effect.
The aforementioned TEC based systems were studied to meet the most extreme
condition that a thermal management system might experience. In many practical
applications, the chip would experience a range of heat loads and/or a wide range of
ambient temperatures. One disadvantage of an only TEC based system is that the TEC
has a relatively high thermal resistance when it is off. Thus, it would have to be
operational even for operating conditions where a conventional thermal management
system would be sufficient, which results in a lower overall COP (Phelan et aI., 2002).
13
Figure 2.3 Schematic of a typical thermal management system incorporating TEC module.
14
CHAPTER 3
METHODOLOGY
15
3.2.1 Design of Parts
i) Design of heat sink
16
CHAPTER 4
4. Project scope
17
The cooling system mainly consists of the following modules Car Blower which acts as
the primary source of air.
1. Duct which conveys the air from the blower to cold heat sinks.
2. One long heat sink is fitted to the hot side of TEC to absorb heat.
3. Aluminum heat sinks that are attached to the cold side.
4. Six TECs are sandwiched between cold and hot heat sinks.
5. An DC source which is used to power the fans and blower. (Car Battery)
6. Dc power supply is used to drive the TECs
18
4.3 Thermoelectric Module
A standard module consists of any number of thermocouples connected in series and
sandwiched between two ceramic plates (See Figure 3). By applying a current to the
module one ceramic plate is heated while the other is cooled. The direction of the
current determines which plate is cooled. The number and size of the thermocouples as
well as the materials used in the manufacturing determine the cooling capacity. Cooling
capacity varies from fractions of Watts up to many hundreds. Different types of TEC
modules are single stage, two stage, three stage, four stage, center hole modules etc.
Single stage will be suitable for a wide range of cooling applications with low to high
heat pumping capacities. A typical single stage is shown in Figure 2.
19
Figure 3: A Classic TE Module Assembly
Before starting to design a TEC cooling system the designer have to take note the
following into consideration.
1. Temperature to be maintained for the object that is to be cooled.
2. Heat to be removed from the cooled object.
3. Time required attaining the cooling after a DC power is applied.
4. Expected ambient temperature.
5. Space available for the module and hot side heat sink.
6. Expected temperature of hot side heat sink.
7. Power available for the TEC.
8. Controlling the temperature of the cooled object if necessary
20
minimum specifications for finding an appropriate TEC by the designer must be based
on the following parameters. The cutaway of a TEC is shown in Figure 4.
22
4.7 Cooling Load
The most difficult and important factor to be accurately calculated for a TEC is
the amount of heat to be removed or absorbed (Qc ) by the cold side of the TEC. In this
project Qc was calculated by finding the product of finding the product of mass flow rate
of air, specific heat of air and temperature difference. Here the temperature difference
system ∆T in the difference between the inlet temperature and outlet temperature of the
cooling system. The mathematical equation for Qc is as shown below.
Qc = m Cp∆T
23
Figure 6: Forced convection heat sink system
The main heat sink parameter for the selection process is its thermal resistance. Heat
sink resistance can be termed as the measure of the capability of the sink to dissipate the
applied heat. The equation is as follows.
- /
R is the thermal resistance (in ⁰C /W or K/W) and - is the hot side temperature and
ambient temperature respectively. Qh is the heat load into the heat sink which is the sum
of TEC power Pe and heat absorbed. = + the goal of a heat sink design is to
lessen the thermal resistance. It can be attained through exposed surface area of the heat
sink. It may also require forced air or liquid cooling. The following Figure 8 shows a
simple thermal schematic of a forced convective heat sink.
Typical values of heat sink thermal resistance for natural convection range is from
0.5°C/W to 5°C/W, whereas for forced convection is from 0.02°C/W to 0.5°C/W, and
water cooled is from 0.005°C/W to 0.15°C/W. Most of the thermoelectric cooling
requires forced convection or water cooled heat sinks. In this project force convective
heat sink is used for the design of the cooling system.
24
Coefficient of Performance
The Coefficient of performance (COP) of a thermoelectric module which is the thermal
efficiency must be considered for a TE system. The selection of TEC will also be based
on the COP factor. COP is the ratio of the thermal output power and the electrical input
power of the TEC. COP can be calculated by dividing the amount of heat absorbed at the
cold side to the input power.
25
Chapter 5
Design of the project
The thermoelectric cooling fan design was preformed based on certain mechanical and
electrical calculations. The fan’s design was compromised on the availability of parts in
the market and budget of the project. The prototype assembly starts with a main fan
which is used to blow the ambient air through a circular duct (Appendix C.1).The duct is
attached to the blower fan and leads towards the heat sinks. The air which is passed
through the duct goes into the heat sink which is at bottom side. This heat sinks acts as a
channel for the air to pass through. There are six TECs that are sandwiched between a
four long black heat sink and long aluminum heat sinks. TEC cold side or the bottom
side rests on the cool side heat sinks. The hot side or the top sides of the TECs are
fastened together with the long heat sink. The TECs were installed between the heat
sinks using thermal grease, which increases the thermal conductivity by balancing
irregular surface of the heat sinks. When the TECs are in operation cold side of the TEC
cools down the heat sink channel. Air which is coming out from the heat sink is chilled
air which is lower than the ambient. Two blower fans fixed on the long aluminum heat
sink which blows ambient air to pass through the cold side heat sink.
26
series also. All the two series connected TECs were connected in parallel. Figure below
illustrates a top view of the connection of TECs as explained above. The arrow indicates
direction of air flow
27
Chapter 6
Results and Calculations
The amount of heat removed or the cooling power was determined before selection of
the TEC. Qc which is the amount of heat absorbed was calculated using the equation
(Qc = ΔΤ). Mass flow rate ( ) of air and is the product of density of air (ρ) and
volume flow rate (Q). Density of air at 32 °C was taken as1.164 kg / m3. Q was obtained
by multiplying velocity of air pass through the rectangular duct of heat sinks and the
cross section area of a heat sink. It is denoted by the equation (Q =V × A). Velocity of
the air passing through the duct was measured using an anemometer and resulted in a
reading of 5.2 m / s2. Cross sectional area of the rectangular duct (W ×H) was calculated
as 0.0042 m2 and the volume flow rate was 0.02184 m3 / s . Specific heat of air (Cp ) at
32 °C was taken as 1005 J / kgK . As discussed that the system ΔΤ is the difference
between the ambient temperature and the temperature of the load to be cooled. It had
been targeted to attain a temp of 25°C form the ambient temperature (32 °C). In other
words the input temperature from the blower fan is 32 °C and the expected output is
25°C
( - )= 32⁰-25⁰=7⁰
The amount of heat load for cooling the air through the rectangular duct was calculated
as 178.7 W.
Please refer Appendix B.1 for detailed calculations on cooling load.
There were two different types of heat sink used for this project. One sort was for the
cold side and another for hot side. The initial idea of the project was to use a hollow
cylinder as duct to channel air, instead of heat sink on the cold side of the TEC. Initial
testing after the proposal stage with hollow cylinder, did not work out well. This was
because there of less heat transfer within the cylinder and the air coming out was not
cold enough. So the decision was made to use to heat sinks which acts a rectangular duct
to channel air. A large heat sinks (9Y692 A00-00) were used. .Each heat sinks have 10
fins which helped to dissipate coldness fast enough from TECs cold side. In this project
heat sinks (hot side and cold side) operate by conducting heat or coldness from the TEC
to the heat sink and then radiating to air. A better the transfer of coldness between the
two surfaces, the better the cooling will be. When the heat sinks were attached the TECs,
there will be uneven surfaces or gaps. The gap will cause for poor heat transfer, even if it
is negligible. To improve the thermal connection between the TECs and the heat sinks a
chemical compound was used. The heat sink compound, typically a white paste made
form zinc oxide in a silicone base ensures a good transfer of heat between the modules
and the heat sinks.
29
Hot Side heat sink
The hot side heat sink used in the project was a single long one installed on the top side
of the TECs. (Appendix Bi). As discussed, thermal resistance of a heat sink is an
important factor while designing a system. Appendix B.1 shows a detailed calculation
for the thermal resistance required for a suitable heat sink. Thermal resistance found
using the equation - / was 0.013 K /W . Therefore a liquid convection heat
sink had to be used. When selecting hot side heat sink for the project other factors such
as dimension to fit into the whole assembly, budget and availability were also taken to
consideration. The heat sink was bought from a local shop and there was no thermal
resistance or datasheets available for the product. The calculated thermal resistance of
the heat sink was lesser than the required. But when considered the dimensions of the
cooling system the selected heat sink was very apt. A drawback expected was
overheating of heat sink. However bigger fans were installed to cool the hot side heat
sink to overcome this.
31
Figure 2: graph of condition 2
Condition 3:
32
Figure 3: graph of condition 3
33
Chapter 7
Conclusion and further works
7.1 Conclusions
A Thermoelectric Air cooling for car prototype was designed and built which can be
used for personal cooling inside the car. Six TECs were used for achieving the cooling
with a DC power supply through car battery. It had been shown from testing results that
the cooling system is capable of cooling the air when recirculating the air inside the car
with the help of blower. TEC cooling designed was able to cool an ambient air
temperature from 32°C to 25.8°C. Cooling stabilizes within three minutes once the
blower is turned ON. The system can attain a temperature difference of set target which
was 7°C. Accomplishing the set target establish the success of the project. All the
components in the project had been tested individually and the results were found to be
positive.
34
cooling in Roof, Floor, Seat, Door, front dashboard with proper insulation. Well-known
TEC brands (.i.e. Melcor, FerroTEC etc) must be chosen if there is only one high power
TEC selected for the cooling system. Bigger hot side heat sinks have to be selected
accurately based its calculated thermal resistances for best cooling efficiency. With a
single TEC, one hot side and a cold side heat sink a smaller personal TEC cooler which
gives comfort can be fabricated and can be installed on roof for individual cooling by
changing the airflow and some mechanical or electronics section modification, the TEC
air cooling for car can be used for heating applications too
35
References
Buist, RJ & Streitwieser, GD March 16-18,1988, The thermoelectricly cooled
helmet, The Seventeenth International Thermoelectric Conference, Arlington,
Texas.
Bulat, L & Nekhoroshev, Y 2003, Thermoelectric cooling-heating unit for
thermostatic body of pickup refrigerated trucks, 22nd international conference on
thermoelectrics.
Goldsmid H. (1986). Electronic Refrigeration.London:Pion.
Goldsmid H.(1964). Thermoelectric Refrigeration. New York:Plenum
Harrington, SS 2009, Thermoelectric air cooling device, Patent Application
Publication, US Patent Number 5623828.
Harvie, MR 2005, Personal cooling and heating system, Patent Application
Publication, US Patent Number 6915641.
Hyeung,SC, Sangkook, Y & Kwang-il, W 2007, Development of a temperature-
controlled car-seat system utilizing thermoelectric device, Applied Thermal
Engineering, pp 2841-2849.
Koetzsch, J & Madden, M 2009, Thermoelectric cooling for industrial
enclosures, Rittal White Paper 304, pp 1- 6.
Larid 2009, Thermoelectric AssembliModules for Industrial Applications,
Application Note, Larid Technologies.
Lauwers, W & Angleo, SD 2009, The Cooling VestEvaporative Cooling, Final
Year Degree Project, Worcester polytechnic institute.
Marlow Industries, Thermoelectric Cooling systems Design Guide, pp -11,
Dallas, Texas.
Melcor 2010, Thermoelectric Handbook, Laird Technologies.
McStravick, M et.al 2009, Medical travel pack with cooling System, Patent
Application Publication, US Patent Number 49845A1.
Rowe, DM & Bhandari CM 2000, Modern thermoelectrics. Reston Publishing,
USA.
36
Rowe, DM 1995, CRC handbook of thermoelectrics. Boca Raton, FL: CRC
Press.
Rowe, DM 2006, Thermoelectrics Handbook: Macro to Nano. Boca Raton, FL:
CRCPress.
ST Microelectronics 2004, 300W Secondary Controlled Two switch forward
converter with L5991A, AN1621 Application Note.
Tellurex. (2002). Retrieved May 2006. http://www.tellurex.com
Tellurex. (2002). The 12 Most Frequently Asked Questions About Themoelectric
Cooling. Retrieved May 2006. http://www.tellurex.com/12most.html
TE Technology, Inc. (2005) Cold Plate/Solid. Free Design Service. Retrieved
June 2006. http://www.tetech.com/design/3081.shtml
TE Technology, Inc. Retrieved May 2006. http://www.tetech.com/techinfo/
TE Technology, Inc. (2005). Thermoelectric Modules. Retrieved April 2006.
http://www.tetech.com/modules/
Taylor, R.A. and Solbrekken, G.L., 2008, "Comprehensive System-Level
Optimization of Thermoelectric Devices for Cooling Electronic
Applications", IEEE Trans. Compon. Packag. Technol., vol. 3, no. 1, pp.
23-31.
Teertstra, P., Yovanovich, M.M. and Culham, lR., 1999, "Analytical Forced
Convection
Modeling of Plate Fin Heat Sinks", Proc. 15th IEEE SEMI-THERM
symphosium, pp. 34-41.
Venkatasubramanian, R., Siivola, E., Colpitts, T. and o'Quinn, B., 2001, "Thin-
Film
Thermoelectric Devices with High Room-Temperature Figure of Merit", Nature
vol. 413, no. 11, pp. 597-602.
Yazicioglu, B. and Yiincii, H., 2007, "Optimum Fin Spacing of Rectangular Fins
on a Vertical base in Free Convection Heat Transfer", Heat Mass Transfer, vol.
44, pp. 11-21.
Yiincii, H. and Kakac, S., Basic Heat Transfer, Bilim Yayincilik Ltd., Sti,
Anfara.
Zhang, H.Y., Pinjala, D., Teo, Poi-siong, 2003, "Thermal Management of High
Power Dissipation Electronic Packages: from Air Cooling to Liquid Cooling",
Electronics Packaging Technology Conference, pp. 620-625.
Zhang, H.Y., Mui, Y.C. and Tarin, M., 2009, "Analysis of Thermoelectric Cooler
Performance for High Power Electronic Packages", Appl. Therm. Eng., vol. 30,
no. 6-7, pp. 561-568.
38
Appendix A(i): Technical Specification of Purchased Items
Regulated DC
Power Supply
Features:
1.Universal AC
input / full range
2.It's good
quality & high
performance
3.Input:AC110-
240V 50/60Hz
6.Protections:
overload/ over
voltage/ short
circuit
7.Cooling by free
air convection
39
1) TEC1-12710
Benefits:
Capable of generating electricity when one side is kept cool and heat is applied to
the other
No moving internal parts to damage when in transit
Makes absolutely no noise and does not vibrate
Long life
Slim and compact
Excellent quality
Brand new and unused
40
Performance curves
41
2) Axial Fan
Product Description
Model Number:AFC1212DE
Size: 120x120x38 mm
Bearing System: Double Ball Bearing
Rated Voltage: 12V (4.00 ~ 13.40)
Input Current: 1.60A
Max Speed: 3900 RPM
Air Flow: 148.34 CFM
Tachometer (RPM Sensor): Yes
PWM (Pulse Width Modulation): Yes
Connector & Wire Length: 4 10" inch wires (white,
red, black, blue) to 5 pin plug
Also replaces AVC DD1203B12HP and NMB MAT
4715KL-04W-B56
Dell OptiPlex GX520, GX620, 745, 740, 755, 760,
960, 320, 330, 210L ,(BTX) MT Dell Dimenision
3100, 5100, 5150, E310, E510, E520 , E521 XPS420
DIM9200
42
Appendix B(i): Calculations
Temperature Difference
∆T=
Cooling load
Qc = ΔΤ
Thermal resistance
- /
= +
43
−10 325.18 1.3413 436.1
−15 322.07 1.3673 440.3
−20 318.94 1.3943 444.6
−25 315.77 1.4224 449.1
Mass flow rate, =
= 1.1644x(0.03x0.14)x5.2
= 0.0254 kg/s
Heat absorbed, Qc = ΔΤ
= ( - )
= 0.0254x1005x(32-25)
= 178.7 W
44
Thermal resistance
- /
= 10x12x6
= 720 W
= +
= 178.7 + 720
= 898.7 W
- /
= (44.3-32) / 898.7
= 0.013 K/W(Therefore liquid cold convection to be used)
45
APPENDIX C1
Pictures of prototype
Axial fan
Cold side
Hot side
46