Deep Learning Access ANPR Camera Users Manual V 1.0.0 1
Deep Learning Access ANPR Camera Users Manual V 1.0.0 1
User's Manual
V1.0.0
Cybersecurity Recommendations
Mandatory actions to be taken towards cybersecurity
1. Change Passwords and Use Strong Passwords:
The number one reason systems get “hacked” is due to having weak or default passwords. It is
recommended to change default passwords immediately and choose a strong password whenever
possible. A strong password should be made up of at least 8 characters and a combination of special
characters, numbers, and upper and lower case letters.
2. Update Firmware
As is standard procedure in the tech-industry, we recommend keeping NVR, DVR, and IP camera
firmware up-to-date to ensure the system is current with the latest security patches and fixes.
“Nice to have” recommendations to improve your network security
1. Change Passwords Regularly
Regularly change the credentials to your devices to help ensure that only authorized users are able to
access the system.
2. Change Default HTTP and TCP Ports:
● Change default HTTP and TCP ports for systems. These are the two ports used to communicate and
to view video feeds remotely.
● These ports can be changed to any set of numbers between 1025-65535. Avoiding the default ports
reduces the risk of outsiders being able to guess which ports you are using.
3. Enable HTTPS/SSL:
Set up an SSL Certificate to enable HTTPS. This will encrypt all communication between your devices
and recorder.
4. Enable IP Filter:
Enabling your IP filter will prevent everyone, except those with specified IP addresses, from accessing
the system.
5. Change ONVIF Password:
On older IP Camera firmware, the ONVIF password does not change when you change the system’s
credentials. You will need to either update the camera’s firmware to the latest revision or manually
change the ONVIF password.
6. Forward Only Ports You Need:
● Only forward the HTTP and TCP ports that you need to use. Do not forward a huge range of numbers
to the device. Do not DMZ the device's IP address.
● You do not need to forward any ports for individual cameras if they are all connected to a recorder on
site; just the NVR is needed.
7. Disable Auto-Login on SmartPSS:
Those using SmartPSS to view their system and on a computer that is used by multiple people should
disable auto-login. This adds a layer of security to prevent users without the appropriate credentials from
accessing the system.
8. Use a Different Username and Password for SmartPSS:
Cybersecurity Recommendations II
In the event that your social media, bank, email, etc. account is compromised, you would not want
someone collecting those passwords and trying them out on your video surveillance system. Using a
different username and password for your security system will make it more difficult for someone to
guess their way into your system.
9. Limit Features of Guest Accounts:
If your system is set up for multiple users, ensure that each user only has rights to features and functions
they need to use to perform their job.
10. UPnP:
● UPnP will automatically try to forward ports in your router or modem. Normally this would be a good
thing. However, if your system automatically forwards the ports and you leave the credentials defaulted,
you may end up with unwanted visitors.
● If you manually forwarded the HTTP and TCP ports in your router/modem, this feature should be
turned off regardless. Disabling UPnP is recommended when the function is not used in real
11. SNMP:
applications.
Disable SNMP if you are not using it. If you are using SNMP, you should do so only temporarily, for
tracing and testing purposes only.
12. Multicast:
Multicast is used to share video streams between two recorders. Currently there are no known issues
involving Multicast, but if you are not using this feature, deactivation can enhance your network security.
13. Check the Log:
If you suspect that someone has gained unauthorized access to your system, you can check the system
log. The system log will show you which IP addresses were used to login to your system and what was
accessed.
14. Physically Lock Down the Device:
Ideally, you want to prevent any unauthorized physical access to your system. The best way to achieve
this is to install the recorder in a lockbox, locking server rack, or in a room that is behind a lock and key.
15. Connect IP Cameras to the PoE Ports on the Back of an NVR:
Cameras connected to the PoE ports on the back of an NVR are isolated from the outside world and
cannot be accessed directly.
16. Isolate NVR and IP Camera Network
The network your NVR and IP camera resides on should not be the same network as your public
computer network. This will prevent any visitors or unwanted guests from getting access to the same
network the security system needs in order to function properly.
General
This user’s manual (hereinafter referred to be "the Manual") introduces the functions and
operations of the deep learning access ANPR camera (hereinafter referred to be "the Device").
Models
ITC215-PW4I-LZF27135
ITC215-PW4I-IRLZF27135
Safety Instructions
The following categorized signal words with defined meaning might appear in the Manual.
Signal Words Meaning
TIPS Provides methods to help you solve a problem or save you time.
Revision History
As the device user or data controller, you might collect personal data of other such as face,
fingerprints, car plate number, Email address, phone number, GPS and so on. You need to be
in compliance with the local privacy protection laws and regulations to protect the legitimate
rights and interests of other people by implementing measures include but not limited to:
providing clear and visible identification to inform data subject the existence of surveillance
area and providing related contact.
Foreword IV
About the Manual
The Manual is for reference only. If there is inconsistency between the Manual and the
actual product, the actual product shall prevail.
We are not liable for any loss caused by the operations that do not comply with the Manual.
The Manual would be updated according to the latest laws and regulations of related
regions. For detailed information, see the paper manual, CD-ROM, QR code or our official
website. If there is inconsistency between paper manual and the electronic version, the
electronic version shall prevail.
All the designs and software are subject to change without prior written notice. The product
updates might cause some differences between the actual product and the Manual. Please
contact the customer service for the latest program and supplementary documentation.
There still might be deviation in technical data, functions and operations description, or
errors in print. If there is any doubt or dispute, please refer to our final explanation.
Upgrade the reader software or try other mainstream reader software if the Manual (in PDF
format) cannot be opened.
All trademarks, registered trademarks and the company names in the Manual are the
properties of their respective owners.
Please visit our website, contact the supplier or customer service if there is any problem
occurred when using the device.
If there is any uncertainty or controversy, please refer to our final explanation.
Foreword V
Important Safeguards and Warnings
This Chapter describes the contents covering proper handling of the Device, hazard prevention,
and prevention of property damage.Read these contents carefully before using the Device,
comply with them when using, and keep it well for future reference.
Power Requirements、
All installation and operation should conform to your local electrical safety codes.
The power source shall conform to the Safety Extra Low Voltage (SELV) standard. Please
note that the power supply requirement is subject to the device label.
Make sure the power supply is correct before operating the device.
A readily accessible disconnect device shall be incorporated in the building installation
wiring.
Prevent the power cable from being trampled or pressed, especially the plug, power socket
and the junction extruded from the device.
Environment
Do not aim the device at strong light to focus, such as lamp light and sun light; otherwise it
might cause over brightness or light marks, which are not the device malfunction, and
affect the longevity of Complementary Metal-Oxide Semiconductor (CMOS).
Do not place the device in a damp or dusty environment, extremely hot or cold
temperatures, or the locations with strong electromagnetic radiation or unstable lighting.
Keep the device away from any liquid to avoid damage to the internal components.
Keep the indoor device away from rain or damp to avoid fire or lightning.
Keep sound ventilation to avoid heat accumulation.
Transport, use and store the device within the range of allowed humidity and temperature.
Heavy stress, violent vibration or water splash are not allowed during transportation,
storage and installation.
Pack the device with standard factory packaging or the equivalent material when
transporting the device.
Install the device in the location where only the professional staff with relevant knowledge
of safety guards and warnings can access. The accidental injury might happen to the
non-professionals who enter the installation area when the device is operating normally.
Do not touch the heat dissipation component of the device to avoid scald.
Carefully follow the instructions in the Guide when performing any disassembly operation
about the device; otherwise, it might cause water leakage or poor image quality due to
unprofessional disassemble. Please contact after-sale service for desiccant replacement if
there is condensed fog found on the lens after unpacking or when the desiccant turns
green. (Not all models are included with the desiccant).
Please strengthen the protection of network, device data and personal information by
adopting measures which include but not limited to using strong password, modifying
password regularly, upgrading firmware to the latest version, and isolating computer
network. For some device with old firmware versions, the ONVIF password will not be
modified automatically along with the modification of the system password, and you need
to upgrade the firmware or manually update the ONVIF password.
Use standard components or accessories provided by manufacturer and make sure the
device is installed and maintained by professional engineers.
The surface of the image sensor should not be exposed to laser beam radiation in an
environment where a laser beam device is used.
Do not provide two or more power supply sources for the device unless otherwise specified.
A failure to follow this instruction might cause damage to the device.
FCC Information
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
FCC conditions:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause
undesired operation.
FCC compliance:
This equipment has been tested and found to comply with the limits for a digital device,
pursuant to part 15 of the FCC Rules. This equipment generate, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communication.
For class A device, these limits are designed to provide reasonable protection against
harmful interference in a commercial environment. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
For class B device, these limits are designed to provide reasonable protection against
harmful interference in a residential installation. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Table of ContentsIX
5.4.3 Network ............................................................................................................................... 63
5.4.4 Event ................................................................................................................................... 66
5.4.5 Storage................................................................................................................................ 70
5.4.6 System ................................................................................................................................ 74
5.4.7 Information .......................................................................................................................... 93
Alarm.............................................................................................................................................. 95
Logout............................................................................................................................................ 96
6 Technical Parameters ........................................................................................................................... 97
7 FAQ .......................................................................................................................................................... 99
Table of ContentsX
1 Introduction
Overview
Deep learning access ANPR camera adopts deep learning smart algorithm. It supports vehicle
detection, license plate recognition, logo recognition, model recognition, vehicle brand and
color recognition and H.265 encoding.
The device consists of protection housing, flash light and HD smart camera. Built-in camera
adopts HD progressive scanning CMOS, which owns several features such as high definition,
low illuminance, high frame rate and excellent color rendition etc. Meanwhile, it supports
simultaneous processing of two channels’ video for both master and slave cameras. It will
automatically select one channel video with better recognition result to report.
The product is widely applied to vehicle capture and recognition of community road, parking lot
and other entrance and exit surveillance.
Features
Some product functions are listed below, which is for reference only. Product functions might
not be completely same according to different models. The actual product shall prevail.
Authority Management
Each user group owns a permission set, which can be freely modified. It is a subset of the
total permission set, and user permission within the group cannot exceed the set of group
permission
Supports 2 user levels.
Sets if the vehicle owns the permission of opening barrier and supports blacklist alarm
function.
Realizes device config management and control permission management via Ethernet.
Storage
Stores corresponding video data onto the central server according to users’ config and
strategy (such as alarm and timing setting)
Users can record via WEB according to their requirements. The recorded video file will be
stored on the computer where client is located.
Supports local hot swapping of storage card and storage when network disconnected. It
implements circulated coverage of picture storage automatically when memory becomes
insufficient.
Supports log function. It can store 1024 log records and support user permission control.
Supports FTP storage and ANR.
Introduction 1
Alarm
It can trigger alarm upon camera operation exceptions via network, such as memory card
damage and so on.
Some devices support alarm output terminal connecting to various alarm peripherals,
responding to external alarm input (within 200ms) in real time. It can correctly deal with
various alarms according to the linkage setting defined by users in advance (such as
informing user via email) and generate corresponding voice prompt (users are allowed to
record voice in advance).
Network Monitoring
Transmit video data of single channel compressed by device to network terminal and make
it reappear after decompression via network. Keep delay within 500ms when bandwidth is
allowed.
The device supports max. 10 users on line at the same time.
Supports system access via WEB, applied to WAN.
Supportsdevice management via WEB mode.
Video data transmission adopts HTTP, TCP, UDP, MULTICAST and RTP/RTCP etc.
Supports system access via WEB, applied to WAN.
Peripheral Control
Supports peripheral control function, it can freely set various peripheral control protocol
and connection interface.
It can externally connect to vehicle detector, signal detector and other devices.
Auto Adjustment
AWB: It can still accurately display the object color when light condition changes
Auto exposure: It can automatically set shutter speed according to the exposure value of
the image measured by metering system, according to shutter and iris exposure set by
factory default.
Auto gain: It can automatically increase camera sensitivity when illuminance is very low,
enhance image signal output so that it can acquire clear and bright image
Introduction 2
Panoramic Camera
It can receive HDCVI image signal input of panoramic camera. Video stream of panoramic
camera can be accessed in real time via WEB.
Introduction 3
2 Device Structure
Deep learning access ANPR camera is an integrated device. The camera is installed in the
housing, the interface board of the camera is concealed and the camera port is connected via
cable.
Dimension
General product dimension diagram (Unit: mm)
Device Structure 4
Structure
Device Structure 5
Device External Cable
Port diagram
Device Structure 6
No. Port Function Description
Alarm output
Brown: ALARM_NO1
Green: ALARM_NC1
Blue: ALARM_NO2
White: ALARM_NC2
Yellow: ALARM_NO3
7 ALARM Alarm port
Orange: ALARM_NC3
Alarm input
Purple: IO_IN1
Pink: IO_IN2
Red: ALARM_IN1
Black: GND
Inputs DC 12V power. Please be sure to supply power as
instructed in the Guide.
Power input
8 Power
port
Device abnormity or damage could occur if power is not
supplied correctly.
Device Structure 7
3 Device Installation
The actual product shall prevail. The following installation figures are for reference only.
Adjust the universal joint UDLR and adjust the camera location.
So far, device installation is completed.
Device Installation8
Bracket Installation
Bracket installation
Device Installation9
4 Basic Configuration
Quick Config Tool
In this chapter, it only introduces the general operations of quick config tool. Please refer to
Quick Config Tool User's Manual
The figures shown in this chapter are for reference only. The actual interface shall prevail.
The default IP of the device is 192.168.1.108. Please modify device IP address according to
network plan when you use it for the first time or network is adjusted.
You can modify device IP address individually or in batches via ConfigTool or you can log in
WEB client and modify device IP address as well.
It can modify device IP address individually when there are fewer devices or device login
password does not match.
When there are more devicesand device login password matches, you can modify IP
addresses in batches.
Preparation
It has acquired ConfigTool setup package, if not, please contact technical support.
The PC which is installed with ConfigTool is interconnected with device via network.
Associated operations cannot be implemented for uninitialized device, which will display gray in
the device list. Besides, it fails to display associated information in other interfaces.
Click .
The Modify IP interface is displayed. See Figure 4-1.
Basic Configuration10
Modify IP
The interface might be different depending on the model you purchased. The
actual product shall prevail.
The initialization interface of the first selected device will be displayed during
initialization in batches.
Basic Configuration11
Device initialization (2)
4.1.2.1 Single
Please refer to 5.4.3 Network for details of logging in WEB client and modifying IP address.
Basic Configuration12
Click .
The Modify IP interface is displayed.
Click Search Setup.
The Setting dialog box is displayed. See Figure 4-4.
Setting
Set device segment, enter login username and password. Click OK.
The searched devices will be displayed after searching is completed.
As for the devices which need to be initialized, they can be used after initialization.
Basic Configuration13
Manual mode: Set Mode as Static, and fill in Target IP, Subnet Mask and
Gateway, and then the device can automatically acquire IP address from DHCP
server.
Click OK to complete modification.
4.1.2.2 Batch
Click .
The Modify IP interface is displayed.
Click Search Setup.
The Setting dialog box is displayed. See Figure 4-6.
Setting
As for the devices which need to be initialized, they can be used after initialization.
Basic Configuration14
Modify IP
Select Same IP and the selected device will be set as the same IP address.
Click OK to complete modification.
Basic Configuration15
Upgrade
Upgrade device.
Single: Click Upgrade and the system begin to upgrade and display progress.
Basic Configuration16
Batch: Click OK and the system begins to upgrade.
If the device is disconnected during upgrade process, it will continue to upgrade when
the device is connected to network again as long as ConfigTool continues to stay at the
upgrade interface.
Web Login
It supports logging in device WEB interface via browser on PC, and realizes device operation,
configuration and maintenance.
The interface and setting are for reference only. The actual interface shall prevail.
It needs to implement initialization when it is the first time to log in or it logs in after
restoring factory default setting.
Please confirm that both PC IP and device IP are in the same network segment, otherwise
it fails to enter initialization interface.
Set IP address, subnet mask and gateway of PC and device respectively.
Distribute IP address of the same segment if there is no router in the network.
It needs to set corresponding gateway and subnet mask if there is router in the
network.
The default IP is 192.168.1.108.
Use ping ***.***. ***. *** (device IP address) command and check if network is
connected.
Open browser, input the IP address of the device in the address bar and press Enter.
After it is successfully connected, the Device Initialization interface is displayed. See
Figure 4-10.
Basic Configuration17
Device Initialization
The new password can be set from 8 characters to 32 characters and contains at
least two types from capital letter, small letter, number and special characters
(excluding “'”, “"”, “;”, “:” and “&”)
If it needs to update password again, go to Setting > System > User > User and
modify.
Prompt box will pop out when username or password is incorrect, see Figure 4-11,
and it will remind you of remaining attempts The account will be locked if user
enters incorrect username or password for 5 times consecutively, the lock time is
300s.See Figure 4-12
Login error
Basic Configuration18
Account locked
Click Finish.
The login interface is displayed. See Figure 4-14.
Login interface
Basic Configuration19
Enter the Password, and then click Login.
The WEB interface (1) is displayed. See Figure 4-15.
WEB interface (1)
Click Please click here to download and install the plug-in in the video window.
The system automatically downloads webplugin.exe and installs it according to prompt.
Before installing plug-in, please make sure the associated plug-in option of active has
been modified as Enable or Prompt in Internet Option > Security.
After installation is completed, the WEB interface (2) is displayed. See Figure 4-16.
WEB Interface (2)
It will pop out the prompt box of authorization failed when the WEB interface hasn’t
been operated for a long time, and then it needs to log in again.
Prompt
Basic Configuration20
4.2.3 Direct Login
Click Run.
The system automatically downloads webplugin.exe and installs it according to prompt.
Before installing plug-in, please make sure the associated plug-in option of active has
been modified as Enable or Prompt in Internet Option > Security.
After installation is completed, the WEB main interface is displayed. See Figure 4-20.
WEB main interface (2)
Basic Configuration21
4.2.4 Password Reset
When you forget the password of admin user, you can set new password via password reset
function.
If you use IE browser, the system might prompt Stop running the script, click No and
continue to run the script.
Basic Configuration22
Reset password (1)
Scan the QR code according to the interface prompt, and send the scanning result to
designated email and acquire security code.
Input received security code in the text box of Security code.
Click Next.
The Reset the password is displayed.See Figure 4-23.
Reset password (2)
Basic Configuration23
4.2.5 Interface Layout
The chapter mainly introduces the operation of following 6 functions on the WEB interface.
SeeFigure 4-24. Please refer to0for more details.
Tab
Basic Configuration24
5 WEB Client
The interface and its setting are for reference only, the actual interface shall prevail.
Guide
WEB Client 25
Work Mode
Configure plate pixel box and make it the optimal plate size.
1) Drag zoom and focus bar.
Adjust visual field to the best.
2) Click Snapshot.
Snapshot becomes Resume.
WEB Client 26
3) Drag the yellow plate pixel box to the plate location.
4) Click Zoom.
Zoom in the picture selected by the plate pixel box. It can realize 2x or 4x zoom
rate.
5) Adjust the location of plate pixel box and make it the optimal plate size. See Figure
5-4.
Plate pixel size
WEB Client 27
Recognition
Live
Click Live tab. The system will display live interface. On this interface it can realize several
functions such as live video, live picture, realtime capture, record and config (LPR) etc.
Live
WEB Client 28
5.2.1 Stream
Set the stream, protocol, fluency and other parameters on the live interface.
Stream
Window switch Switch to big window and display image adjustment window.
WEB Client 29
Big window
The function can only adjust image brightness, contrast, hue and saturation of local WEB.
As for the adjustment of system brightness, contrast, hue and saturation, it needs to go to
Setting > Camera > Image and make settings.
Table 5-4 Image adjustment
Icons Name Note
Adjust monitoring image brightness. The range is from 0 to
Brightness
128. It is 64 by default.
WEB Client 30
Adjust monitoring image contrast. The range is from 0 to
Contrast
128. It is 64 by default.
Adjust monitoring image hue. The range is from 0 to 128. It
Hue
is 64 by default.
Adjust monitoring image saturation. The range is from 0 to
Saturation
128. It is 64 by default.
Click the icon to restore brightness, contrast, saturation and
Reset —
hue to default value.
Talk
Click to enable talk. Click again to end talk.
WEB Client 31
Click , enter the interface of Config (LPR).
Config (LPR)
The configured area line and detection line in the Guide are displayed in the video
interface.
Table 5-7 Config line parameters description
Parameter Note
Click it and draw the area range which needs to be detected.
Recognition
The recognition area line is displayed as red box.
WEB Client 32
Parameter Note
Draw the detection line which triggers video capture, it is as functional as the
line in traffic. It will trigger and take snapshot when the vehicle crosses the
Snap Line
detection line.
Snap line is displayed as green line.
Set the area range which needs to be shielded. LPR is not implemented within
Shielded
the shielded area. It supports setting max two shielded areas.
Area
Area line is displayed as gray box.
Optimal Click it and drag the yellow plate pixel box to proper location on the video
Plate interface.
Draw lines on the view interface.
Query
Click Query tab and the system displays query interface where users can inquire picture and
record info.
WEB Client 33
5.3.1 Picture Query
5.3.1.1 SD Picture
Query condition can be set in this section. It inquires the event info and plate info of the SD card
within the period.
Select Query > Picture Query > SD Picture.
The SD Picture interface is displayed. See Figure 5-15.
SD Picture
Configure parameters according to actual requirement. Please refer to Table 5-9 for
more details.
Table 5-9 SD picture parameter description
Parameter Note
Start Time Set the start time of picture query.
End Time Set the end time of picture query.
Inquire all pictures, or it can inquire the pictures which conform to
Event Type
requirements according to filtering condition based on violation type.
Vehicle Logo Take vehicle logo as query condition, then it can select one or all.
Select Plate, take plate feature as query condition and then inquire the
pictures which conform to requirements.
Plate
It can also set some parameters of the plate and realize fuzzy query of plate
no.
Click Searchand it will display all the picture file lists which conform to query condition
in the file list.
Click some line in the list and the plate picture info will be displayed in the Real Plate
Info.
Download picture.
Single download: Select the picture which needs to be downloaded from the file list
and click Download.
Check All: Click it and download all the picture files of the current page from the
search list. Click Download.
Download by time: Click it and download all the picture files from start time and
end time. Click Download.
Set the storage path of picture in the dialog box. The system starts to download the
pictures to local PC.
WEB Client 34
Click Open or double click the picture if you need to preview the picture.
If several picture files are selected at the same time, click Open to open all the pictures.
Configure the parameters. Please refer to Table 5-10 for more details.
Table 5-10 Download attribute parameters description
Parameter Note
Create time: It uses PC time when the picture is downloaded to PC.
Download
Snap time: It uses device snapshot time when the picture is downloaded
Time
to PC.
Selected file: Select the needed picture (It supports selecting single
picture or several pictures at the same time, which is download in
Download
batches), click Download and the system will pop out the save dialog box.
Mode
Selected time: Click Download and the system will automatically
download all the pictures from start time and end time.
Reset Restore the picture name to the system default name.
Help View the naming rule of downloaded pictures.
Click OK to finish configuration.
WEB Client 35
5.3.1.3 PC Picture
In this section, it is to check if the watermark of PC picture is tampered.
Select Query > Picture Query > PC Picture.
The PC Picture interface is displayed. See Figure 5-17.
PC picture
Click Open Local and select the folder where the verified picture is located.
Select the picture which needs to be verified.
Click Watermark Verify and view result in the picture list.
Click Open or double click the picture if you need to preview the picture.
5.3.2.1 Record
It can realize playing video of local PC on this interface.
SelectQuery > Record Query > Record.
The Record interface is displayed, see Figure 5-18.
Record
WEB Client 36
Click Open Record, select record path, click Open and view the video.
For the function description of video play button, see Table 5-11.
Table 5-11 Play function description
Icons Name Note
Play by
Click the icon to skip to the next frame.
Frame
Slow-down
Play Click this icon to slow down video playing.
Speed-up
Play Click this icon to speed up video playing.
5.3.2.2 Watermark
It needs to go to Setting > Camera > Stream > Video Stream and select watermark setting if
you want to enable the function, and set corresponding watermark character. The default
watermark character is DigitalCCTV.
In this section, it is able to verify if the watermark of local record is tampered.
Select Query > Record Query > Watermark.
The Watermark interface is displayed. See Figure 5-19.
Watermark
Click Open Record and select a file that you want to verify.
Click Water Verify and the system displays verify progress, normal watermark and
some other info.
WEB Client 37
The interface of Watermark Verification Completed will be displayed after verification
is finished.
It supports max 10,000 records and 1024 records respectively when the camera is
installed with TF card or not.
If the passing vehicle records are unreadable in excel after being imported, change them
into UTF-8 encoding in txt and then they can be opened normally.
Set start time and end time, inquire the vehicle record within the period.
Select Query > Plate Query > Plate Query.
The Plate Query interface is displayed. See Figure 5-20.
Plate Query
Setting
In this interface, you can configure several parameters such as ITC, camera, network, event,
storage, system and system info etc.
5.4.1 ITC
In this section, you can set business rules of ITC.
WEB Client 38
Work Mode
When work mode is selected as Main Camera Mode + Panoramic Camera Mode,
then Panoramic Camera will be displayed in the video stream bar on the upper left
corner of the Live interface.
5.4.1.2 Detection
5.4.1.2.1 Snapshot
WEB Client 39
Snapshot
Configure parameters according to actual requirement. Please refer to Table 5-12 for
more details.
Table 5-12 Snapshot setting parameters description
Parameter Note
Auto Automatically select work mode according to actual scenario.
Loop: Forced to use loop for snapshot.
Work Mode Video: Forced to use video for snapshot.
Manual
Mix: Forced to use coil + video mixed mode to take
snapshot.
Snapshot
It can take 1 to 2 snapshots.
Amount
Approach: Capture the entered vehicles.
Snapshot
Away: Capture the exited vehicles.
ANPR Direction
Double: Both entered and exited vehicles are captured.
Parameters
Input max vehicle passing time, the unit is s, it is 5s by default.
Max pass For example, set max vehicle passing time as 5s, when using
time mix in and mix out with loop, after the logical loop is triggered, it
will trigger capture loop camera not to take snapshot within 5s.
Click OK to finish configuration.
5.4.1.2.2 I/O
In this section, it will configure 485 interface associated config info and loop IO snapshot config.
Select Setting > ITC > Detection > I/O, the I/O interface is displayed.
WEB Client 40
RS485/IO(Start RS485)
Select COM Port, and then you can select COM 1, COM 2 and COM3.
Select COM1 and support vehicle detector, transparent 485 and com port push
protocol.
Select COM2, support transparent 485 and com port push protocol.
Select COM3, support transparent 485, transparent 232 and com port push
protocol.
Select Protocol, and set protocol type according to the number of com port.
Select Car Detect from Protocol. The setting steps are shown as follows.
1) Set the baud rate of the protocol.
2) Select scheme.
◇ Single_in 1 snapshot: Lay single coil and it will take snapshot when the
vehicle enters coil.
◇ Vehicle_double_in 1 snapshot: Lay double coil and it will take snapshot when
the vehicle enters the first coil.
◇ Vehicle_double_in 2 snapshot: Lay double coil and it will take snapshot when
the vehicle enters the second coil.
3) Click Setting and it pops up the dialog box of Coil Map. Select the corresponding
relationship between logical coil and physical coil and click OK.
The function needs to be configured in the mix in and mix out mode. Please refer
to Standard Construction Scheme for more details.
When the scheme is Single_in_1 snapshot, then it only needs to select the
corresponding physical coil of logical coil.
For Protocol, it selects Transparent 485 or Transparent 232. The steps are
shown as follows.
1) Select the baud rate of the protocol and complete setting.
2) If it needs test, then it needs to select Hexadecimal Push. Click Open on the right
of reception area and test the reception status of transparent 485 according to
actual situation.
For Protocol, it selects COM Push. The setting steps are shown as follows.
Select the baud rate of the protocol and complete setting.
Click OK to finish configuration.
WEB Client 41
Start Coil IO
Select Start Coil IO butnot select Start RS485 Port.
The Setting interface is displayed. See Figure 5-24.
I/O (Start Coil IO)
Configure the parameters. Please refer to Table 5-13 for more details.
Table 5-13 Coil IO parameters description
Parameter Note
IO Select IO, and only Coil IO can be selected here.
Coil 1 Set the coil trigger mode.
No trigger: No snapshot is triggered.
Rise Edge: Snapshot is triggered when the vehicle enters
Trigger
coil.
Mode Config
Coil 2 Fall Edge: Snapshot is triggered when the vehicle exits coil.
WEB Client 42
I/O (Start RS-485 and Coil IO)
Push the snapshot and data info mode to server according to actual requirement.
Select Setting > ITC > Detection > Com Port.
The Com Push interface is displayed. See Figure 5-26.
Com Push
Configure parameters according to actual requirement. Please refer to Table 5-14 for
more details.
Table 5-14 Com Push
Parameter Note
Select fast configuration mode, which includes common config and all config.
Fast
Common config: Click it and select the common vehicle passing option.
Configuration
All config: Click it and select all the vehicle passing options in the list.
Configure picture data information.
Tag Head: Com port protocol head, the standard is 4 bit, it can only input
hexadecimal character.
General
Tag Tail: Com port protocol tail, the standard is 4 bit, it can only input
Configuration
hexadecimal character.
Encode mode: It is the encoding mode of Com port push content.
Check mode: verification mode of com port protocol.
Up Move: Click it and select the corresponding option and move up.
WEB Client 43
Down Move: Click it and select the corresponding option and move down.
5.4.1.3 Intelligent
5.4.1.3.1 Recognition
In this section, you can set vehicle recognition parameter, recognition mode and some other
functions.
Select Setting > ITC > Intelligent > Video Analysis > Recognition.
The Recognition interface is displayed. See Figure 5-27.
Recognition
Configure the parameters. Please refer to Table 5-15 for more details.
Table 5-15 Recognition parameters description
Parameter Note
Car Series Detect
Vehicle Logo
Vehicle Type
Select parameters of car series recognition according to requirement.
Vehicle Color
Non-Structured
Data
Set plate’s min width, max width; min height and max height. The unit
is pixel.
Plate Size The setting item is combined with config (LPR) or guide plate pixel on
the live interface, which is used to set the optimal location of plate and
the optimal width of the location. Try to make sure the location and size
of plate is in accordance with that of the yellow line box.
WEB Client 44
Parameter Note
Repeat plate
One plate can only trigger one ANPR event within the period.
detection time
Click OK to finish configuration.
In this section, you can configure the advanced functions of plate recognition and customize
special functions.
Select Setting > ITC > Intelligent > Video Analysis > Advance Config.
The Advance Config interface is displayed. See Figure 5-28.
Advance Config
Configure parameters according to actual requirement. Please refer to Table 5-16 for
more details.
Table 5-16 Advance config parameters description
Parameter Note
Confidence level, used to set the range of limiting plate
recognition condition, adjustment range is from 0 to 100.
The lower the confidence level is, the less limited conditions
there will be, and correspondingly the plate is easier to be
Plate confidence filtering recognized and false capture rate becomes higher as well.
The higher the confidence level is, the more limited
conditions there will be, and correspondingly the plate is
harder to be recognized and false capture rate becomes
lower as well.
Algorithm Customized Inputs customized algorithm expression and realize customized
Expression special function.
Click OK to finish configuration.
WEB Client 45
Select Setting > ITC > OSD Config > Video OSD.
The Video OSD interface is displayed, see Figure 5-29.
Video OSD
Click Customize , add customized region and set OSD info and its display location
according to requirement.
WEB Client 46
Picture OSD
Move the title box to displayed location, or manually input coordinate value into the X/Y
box in the lower right corner of the interface.
Select Black Position, which includes top, bottom or none.
Set font size and scheme of OSD info. You can set font color of picture OSD info in the
lower right corner of the interface.
Click More.
Line feed and separator are displayed. See Figure 5-31.
Line and separator
Select New Line according to actual requirement and set separator types of OSD info.
You can manually input other separators when selecting Customize from OSD
Separator.
Set OSD option.
WEB Client 47
Parameter Note
Click it and all the OSD info status is displayed as except line feed. Click
Modify
to modify the prefix, suffix, content and separator of corresponding OSD
option.
Delete Click it and all the selected OSD info status is displayed as , click to
delete corresponding OSD option.
Clear Delete all the OSD info.
After selecting some OSD info, click New Line and next OSD info will be
Line Feed
displayed on the picture.
Click OK to finish configuration.
Select Snap Cutout and Plate, and then plate cutout function is enabled.
Click OK to finish configuration.
In this interface, it can view the type, number, status and match status of extra device.
If it is connected to vehicle detector of our company and the com protocol selects vehicle
detector, then it can detect if the associated info and status of vehicle detector is normal.
Select Setting > ITC > Extra Device > Extra Device Status and the interface of Extra Device
Status is displayed. See Figure 5-33.
WEB Client 48
Extra Device Status
5.4.1.6.2 Spotlight
In this section, you can configure light array and output mode of spotlight.
Select Setting > ITC > Extra Device > Spotlight.
The Spotlight interface is displayed, see Figure 5-34.
Spotlight
WEB Client 49
Parameter Note
When Work Mode is Auto, then you can automatically turn on or turn off
spotlight according to time or brightness.
Time: Set the period during which the spotlight is enabled. Independent
Auto Mode config 7 days a week, each day supports 6 periods.
Brightness: Set brightness default value. Spotlight is enabled when
environmental brightness is lower than the default value and the spotlight
is disabled when it is higher than default value.
Click OK to finish configuration.
5.4.1.7 BW List
Enable white list. When the system detects the vehicles in the white list, then it will enable
open-barrier mode and set white list matching function.
Select Setting > ITC > BW List > White List Setup.
The White List Setup interface is displayed. See Figure 5-35.
White List Setup
WEB Client 50
5.4.1.7.2 White List Search
In this section, you can inquire if some plate exists in the white list, import and export white list
vehicle info.
Select Setting > ITC > BW List >White List Setup.
The White List Search interface is displayed. See Figure 5-36.
White List Search
WEB Client 51
Add
Please make sure the time format in list is in accordance with that of the camera when
importing white list.
Click OK to finish configuration.
WEB Client 52
5.4.1.7.3 Black List Search
In this section, you can inquire if some plate exists in black list, import and export black list plate
number and vehicle info.
Select Setting > ITC > BW List >Black List Setup.
The Black List Search interface is displayed. See Figure 5-38.
Black List Search
The query, import and export function of black list is similar to those of white list. Please
refer to 5.4.1.7.2White List Search for more details.
Click OK to finish configuration.
In this section, you can set the barrier control mode; configure info of opening barrier and
closing barrier.
Select Setting > ITC > BW List >Barrier Control.
The Barrier Control interface is displayed, see Figure 5-39.
Barrier control ,
Configure the parameters. Please refer to Table 5-19 for more details.
Table 5-19 Barrier control parameter description
Parameter Note
Select it and enable the function of barrier normally on. Configure the period
Keep Open
of barrier normally on. The barrier will not close during the period you set.
Enable Select it to enable barrier control and config.
WEB Client 53
Parameter Note
It can trigger alarm via different barrier mode.
White List Open: Capture the vehicle which conforms to white list or
fuzzy matching and then output open barrier signal.
Every Trigger (Camera): Capture any vehicle and output open barrier
Barrier
signal.
Control Type
Every Plate (Camera): Capture any plated vehicle and output open
barrier signal.
Order (Server): Platform issues command and output open barrier
signal.
Manual Open Click the button and manually trigger outputting signal of opening barrier.
Manual Close Click the button and manually trigger outputting signal of closing barrier.
Open Config Relay-out: Activate alarm linkage output port. You can select anyone out
of 3 ports.
Close Config Signal Duration: It is the time for which the open barrier or close barrier
signal is going to last.
Click OK to finish configuration.
Click Default.
The DEFAULT interface is displayed. See Figure 5-41.
WEB Client 54
Default
5.4.2 Camera
In this section, you can set image parameter, video and stream parameters.
5.4.2.1 Attributes
5.4.2.1.1 General
In this section, you can set parameters such as image brightness, contrast, hue, saturation and
ICR switch etc.
Select Setting > Camera > Attributes > General.
The GENERAL interface is displayed. See Figure 5-43.
WEB Client 55
General system settings
Configure parameters according to actual requirement. Please refer to Table 5-20 for
more details.
Table 5-20 General parameters description
Parameter Note
It is used to adjust the overall image brightness, change the value when the
image is too bright or too dark.
The bright and dark areas will have equal changes. The image becomes blurry
Brightness
when the value is too big. The recommended value is from 40 to 60. The range
is from 0 to 100.
The default value is 50. The bigger the value is, the brighter the image becomes.
Change the value when the image brightness is proper but contrast is not
enough.
If the value is too big, the dark area is likely to become darker and the bright
area is likely to be overexposed.
Contrast
The picture might be blurry if the value is set too small. The recommended
value is from 40 to 60 and the range is from 0 to 100.
The default value is 50. The bigger the value is, the more obvious the contrast
between the bright area and dark area will become.
It is used to adjust the image hue. For example, change red into blue. The
default value is made by the light sensor and normally it doesn’t have to be
adjusted. The recommended value is from 40 to 60 and the range is from 0 to
Hue
100.
The default value is 50. The threshold is used to adjust image hue and ot will not
influence image overall brightness.
WEB Client 56
Parameter Note
It is used to adjust the color vividness and will not influence the image overall
brightness.
The image becomes too flamboyant if the value is too big.
Saturation The image is not flamboyant enough if the value is too small. The
recommended value is from 40 to 60 and the range is from 0 to 100.
The default value is 50. The bigger the value is, the more flamboyant the image
becomes.
Auto: Set brightness default value, it will realize auto switch when it exceeds
ICR the default value.
Switch IR: The filter is switched to IR mode when the image is black and white.
General: The filter is switched to general mode when the image is color.
Click OK to finish configuration.
5.4.2.1.2 Shutter
In this section, you can set camera shutter config, including shutter mode, exposure mode, gain
mode and scene mode etc.
Select Setting > Camera > Attributes > Shutter.
The Shutter interface is displayed. See Figure 5-44.
Shutter
Configure parameters according to actual requirement. Please refer to Table 5-21 for
more details.
Table 5-21 Shutter parameters description
Parameter Note
Shutter Mode Both video recording and image capture adopt the same exposure mode.
Video 3D NR Select On to enable 3D NR function and lower video noise.
Scene Switch to different scene for config.
WEB Client 57
Parameter Note
Set the image sharpness under the scene.
The bigger the value is, the higher the detail contrast becomes, the clearer
Sharpness
the image becomes. The image tends to generate noise when the value is
set too big.
The system dims bright areas and compensates dark areas to ensure the
WDR clarity of both areas. The bigger the value is, the higher the WDR level
becomes.
Select lens exposure mode, which includes auto and manual.
Auto: Auto exposure.
Exposure Mode Manual: Fixed exposure value. It needs to set the time of manual
exposure, including 8 options between 1/50 and 1/10000.
Users can customize value and range.
Auto Gain: Set the range of auto gain.
Gain Mode
Fixed Gain: Set the fixed gain value.
Select the device environment and set scene mode. Adjust the device
Scene Mode
monitoring image to its best status.
Click OK to finish configuration.
In this section, you can set the measure mode of metering zone.
Select Setting > Camera > Attributes > Metering Zone.
The Metering Zone interface is displayed, see Figure 5-45.
Metering Zone
Configure parameters according to actual requirement. Please refer to Table 5-22 for
more details.
WEB Client 58
Table 5-22 Metering zone parameter description
Parameter Note
Select measure mode: It includes spot measure, global measure ans partial
measure.
Spot measure: Measure the brightness of moving vehicle and
intelligently adjust the overall image brightness.
Global measure: Measure the brightness of the whole image area and
Measure Mode intelligently adjust the overall image brightness.
Partial measure: Measure the brightness of sensitive area and
intelligently adjust the overall image brightness. If the measured area
becomes bright, then the whole area becomes dark, and vice versa.
Drag the mouse to select the measured area and the system displays
yellow box; Drag the box to proper location, click OK and complete config.
Backlight When selecting Spot Measure, you can select backlight and frontlight
according to scene requirement, and then improve the backlight image
Frontlight
brightness.
When selecting Partial Measure, you can select if it is to enable plate
Plate Meter exposure mode according to actual requirement.
Enable If there is vehicle plate in the selected partial area, it will adjust the image
according to plate info and display plate info more clearly.
Click OK to finish configuration.
5.4.2.2 Video
5.4.2.2.1 Video
When selecting the work mode of two cameras from Setting > ITC > Work Mode, the main
camera needs to configure main stream and sub stream, besides, the panoramic camera
needs to configure main stream as well.
In this chapter, it is to select the work mode as Main Camera + Panoramic Camera and
introduce the stream config.
In this section, you can set the camera stream information.
Select Setting > Camera > Video > Video.
The Video interface is displayed, see Figure 5-46.
WEB Client 59
Video
Configure parameters according to actual requirement. Please refer to Table 5-23 for
more details.
Table 5-23 Video parameters description
Parameter Note
Stream
Currently it supports general stream.
Type
Encode Currently it only supports H.264B, H.264M, H.264H, H.265 and
Mode MJPEG.
Resolution Select resolution according to the actual situation.
Frame
Select frame rate according to the actual situation.
Rate (FPS)
Include VBR and CBR.
Bit Rate
Image quality can be set only in VBR mode while it cannot be set in
Type
CBR mode.
Main Image
Image quality can be set in VBR mode. There are 6 levels optional.
Stream Quality
The value is the upper limit of the stream in VBR mode while it is fixed
Bit Rate
in CBR mode.
I Frame P frame quantity between two I frames, it is max 150. The system
Interval default is set twice as big as frame rate.
You can view if the video is tampered via verifying watermark
character.
Watermark Select Watermark Settings and enable the function.
Settings Default Watermark character is: DigitalCCTV.
The watermark character can only consist of number, letter,
underline and maximum length contains 85 characters.
Enable Select it and enable sub stream.
Stream
Sub Currently it only supports general stream.
Type
Stream
Encode Currently it only supports H.264B, H.264M, H.264H, H.265 and
Mode MJPEG.
WEB Client 60
Parameter Note
Currently it only supports 720P and D1.
Resolution
The resolution of sub stream cannot be greater than main stream.
Frame
Select frame rate according to the actual situation.
Rate (FPS)
Include VBR and CBR.
Bit Rate
Image quality can be set only in VBR mode while it cannot be set in
Type
CBR mode.
Image
Image quality can be set in VBR mode. There are 6 levels optional.
Quality
The value is the upper limit of the stream in VBR mode while it is fixed
Bit Rate
in CBR mode.
I Frame P frame quantity between two I frames, it is max 150. The system
Interval default is set twice as big as frame rate.
Click OK to finish configuration.
5.4.2.2.2 Snapshot
In this section, you can set the picture stream, including resolution, quality or picture size.
Select Setting > Camera > Video > Snapshot.
The Snapshot interface is displayed, see Figure 5-47.
Snapshot
Configure parameters according to actual requirement. Please refer to Table 5-24 for
more details.
Table 5-24 Snapshot parameters description
Parameter Note
Snapshot
Currently it only supports general snapshot.
Type
Resolution The snapshot resolution.
Picture Size It is in accordance with resolution value.
Image Quality Set the snapshot quality which includes 6 levels optional.
WEB Client 61
Parameter Note
Set picture coding size, there are 8 levels optional; Or select Customized,
Picture the range is from 50 to 1024.
Coding Size
You can select either picture quality or picture coding size to make setting.
Click OK to finish configuration.
5.4.2.2.3 ROI
Configure parameters according to actual requirement. Please refer to Table 5-25 for
more details.
Table 5-25 ROI parameter description
Parameter Note
Image Quality Set snapshot quality which includes 6 levels optional.
WEB Client 62
Click it and delete the latest ROI. It can click for several times. Right click any
Delete
position in the image to realize the same effect.
Click OK to finish configuration.
5.4.3 Network
In this section, you can set IP address, port and other parameters.
5.4.3.1 TCP/IP
Some models support dual network port. Please do not set them in the same network segment;
otherwise it may cause network error.
You need to configure the device IP address and DNS server. Make sure it is connected to
other devices in the network.
Select Setting > Network > TCP/IP.
The TCP/IP interface is displayed. See Figure 5-49.
TCP/IP
Configure parameters according to actual requirement. Please refer to Table 5-26 for
more details.
WEB Client 63
Table 5-26 TCP/IP parameter description
Parameter Note
Host Name The name of host device Supports max 15 characters.
Ethernet Card Select the Ethernet Card you need to configure, the default one is Wire.
Network mode, including static and DHCP.
DHCP Mode: Automatically acquire IP, at this moment IP, subnet
Mode
mask and gateway cannot be set.
Static Mode: It needs to manually set IP, subnet mask and gateway.
MAC Address Host MAC Address
IP version, including IPv4 and IPv6. The IP address of both versions can
IP Version
be accessed.
Address Device IP Address
Subnet Mask The corresponding subnet mask of device IP address.
Default Gateway Corresponding gateway of device IP address.
Preferred DNS IP address of DNS server.
Alternate DNS Alternate IP address of DNS server.
Click OK to finish configuration.
5.4.3.2 Connection
5.4.3.2.1 Connection
In this interface, it can set the connected port info, it can access device via different protocols or
config tool.
Select Setting > Network > Connection > Connection.
The Connection interface is displayed, see Figure 5-50.
Connection
Configure each port value of the device. Please refer to Table 5-27 for more details.
Table 5-27 Connection parameters description
Parameter Note
WEB Client 64
Parameter Note
The max number of clients (web client, platform client and so on) that
Max Connection
can connect to the device simultaneously; the value is 20 by default.
TCP Port TCP protocol communication provides service. The default is 37777.
UDP Port User data packet protocol port. The default is 37778.
HTTP Port HTTP communication port, the value is 80 by default.
HTTPS Port HTTPS communication port. The default is 443.
Click OK to finish configuration.
5.4.3.2.2 ONVIF
ONVIF (Open Network Video Interface Forum) enables network video framework agreement.
Enable ONVIF, and realize network video framework agreement to make different network
video products interconnected.
WEB Client 65
ITC push config
Configure parameters according to actual requirement. Please refer to Table 5-28 for
more details.
Table 5-28 ITC Push
Parameter Note
Enable Select it and enable the push function of passing vehicle info.
No Plate Upload Select it and enable the unlicensed push function.
Server IP It is the IP of server which receives passing vehicle info.
Server Port The port of server which receives passing vehicle info.
Username
Username and password used to log in server.
Password
Http URL Http URLprefix info of uploaded picture data.
Device ID Device ID
Http Timeout Timeout of Http push message.
Keep Alive Time It can set keep alive time.
Encode Mode Encode mode of push content, which includes UTF8 and GB2312.
Select the pushed picture type, which includes original picture and dig
Push Picture Config
picture.
Click OK to finish configuration.
5.4.4 Event
In this section, you can set alarm and abnormality.
5.4.4.1 Alarm
In this interface, you can set several parameters of relay activation such as relay-in, period,
anti-dither and sensor type etc.
Select Setting > Event > Alarm> Relay Activation.
WEB Client 66
The Relay Activation interface is displayed, see Figure 5-53.
Relay Activation
2) Click the Setting behind the day you need to configure time period.
WEB Client 67
3) Select the period you need to enable and input start time and end time of
corresponding period.
4) If you need to apply this period setting to any other day, select the check box of the
corresponding days.
5) Click OK and make the period of the day valid.
Repeat the steps above and make settings upon any other day.
Make setting upon other parameters. Please refer to Table 5-29 for more details.
Table 5-29 Relay activation parameter description
Parameter Note
Anti-dither Input anti-dither time. It ranges from 0s to 100s.
Select relay-in type according to the connected alarm input device.
Sensor Type NO: Low level valid.
NC: High level valid.
Optocoupler output, select check box and it will activate corresponding
Relay-out
alarm output device when alarm occurs.
Alarm Delay The time that delays alarm when alarm occurs.
Click OK to finish configuration. ,
5.4.4.1.2 Relay-out
5.4.4.2 Abnormality
In this section, you can set relay-out mode of different events.
Select Setting > Event > Abnormality.
WEB Client 68
The Abnormality interface is displayed. See Figure 5-56, Figure 5-57, Figure 5-58,
Figure 5-59, Figure 5-60 and Figure 5-61.
No Storage Card
SC Space Lack
SC Error
Disconnection
WEB Client 69
IP Conflict
Illegal access
Configure parameters according to actual requirement. Please refer to Table 5-30 for
more details.
Table 5-30 Abnormality parameters description
Parameter Note
Enable Select it and enable corresponding functions of processing abnormality.
Floor Level of SC Set the remaining max space which triggers abnormality.
Select it and enable corresponding relay-out function, select the port
Relay-out
number of relay-out.
Relay-out lasts a period of time and stops after alarm is over.
Signal Duration
The time unit is second and it ranges from10s to 300s.
Login Error Set the max times of login error, it ranges from 3 to 10
Click OK to finish configuration.
5.4.5 Storage
In this section, you can set associated info of storage and record control.
5.4.5.1 Point
Set the storage path of snapshot.
Select Setting > Storage > Destination > Path.
The Point interface is displayed, see Figure 5-62.
WEB Client 70
Point
5.4.5.2 Local
WEB Client 71
5.4.5.3 FTP
It can set picture name and storage path, click Help to view naming rule.
FTP function can be enabled only when it was selected as destination path. When the network
doesn’t work, you can save all the files to the internal SD card for emergency.
Select Setting > Storage > Destination > FTP.
The FTP interface is displayed, see Figure 5-64.
FTP
Configure parameters according to actual requirement. Please refer to Table 5-31 for
more details.
Table 5-31 FTP parameter description
Parameter Note
Protocol Type Select FTP storage protocol, which includes SFTP and FTP.
Select it and enable offline transfer.
When network is disconnected or failed, you can store the picture into local
Offline Transfer
storage card and it will automatically upload to FTP server or platform after
network resumes.
Enable Enable the storage path of FTP server.
Server IP IP address of FTP server.
Encode mode of Chinese character when naming picture, which includes
UTF8 and GB2312. Click Test and it create two files adopting UTF-8 and
Encode Mode
GB2312 on the FTP server, which can be used to confirm server’s encoding
mode.
Port The port number of FTP server.
Username Username and password of FTP server.
WEB Client 72
Parameter Note
Password
Set the naming mode of picture and storage path. Please refer to Help for
FTP Naming
more details.
Click OK to finish configuration.
5.4.5.4 Client
In this section, you can set the parameters of offline transfer.
Select Setting > Storage > Destination > Client.
The Client interface is displayed. See Figure 5-65.
Client
Configure parameters according to actual requirement. Please refer to Table 5-32 for
more details.
Table 5-32 Client
Parameter Note
When network is disconnected or failed, you can store the picture into local
Offline Transfer storage card and it will automatically upload to platform server after network
resumes.
Select connection type with platform server.
Type IP: Connect to platform server via IP address.
MAC: Connect to platform service via MAC address.
Server Select server which includes server 1 and server 2.
When the type is selected as IP, then it has to fill in the server’s IP
address.
Server IP
When the type is selected as MAC, then it has to fill in the server’s
MAC address.
Click OK to finish configuration.
5.4.5.5 Path
In this section, you can set picture, record naming and path.
Select Setting > Storage > Destination > Path.
The Path interface is displayed. See Figure 5-66.
WEB Client 73
Storage path
According to your actual requirement, set the naming of picture and storage path.
Please refer to Help for more details.
Set the root path of record and snapshot according to actual requirement.
Click OK to finish configuration.
5.4.6 System
The system supports configuring general info, adding user, restoring default setting and
configuring import & export file etc.
5.4.6.1 General
5.4.6.1.1 General
In this section, you can set device SN, language and video standard etc.
Select Setting > System > General > General.
The General interface is displayed. See Figure 5-67.
WEB Client 74
General
Configure the parameters. Please refer to Table 5-33 for more details.
Table 5-33 General parameters description
Parameter Note
Device SN The device’s ID number. Supports English or number.
Device Code Device Code Failed to support OSD info overlay.
The language displayed on WEB. The language will be automatically
Language switched after logging in WEB again. Currently it only supports
simplified Chinese.
PAL: Phase Alternating Line currently most countries around the
world (including most countries in Europe, Africa, Australia and
Video Standard China) adopts this standard.
NTSC: National Television System Committee The main countries
which adopt this standard include America, Canada and Japan etc.
Machine Group The device’s group information.
Machine Address Set the location info of device capture.
Click OK to finish configuration.
In this interface, you can set date and time format, system time, DST (Daylight Saving Time) or
NTP server and so on.
Select Setting > System > General > Date & Time.
The Date & Time interface is displayed. See Figure 5-68.
WEB Client 75
Date & Time
Configure the parameters. Please refer to Table 5-34 for more details.
Table 5-34 Date & Time parameter description
Parameter Note
Date Format Select date format.
Time Format Select 24h or 12h system.
System Set current system time of the device. It becomes valid immediately after
Time setting.
Sync PC Modify the device system time to the PC system time.
Enable the function and then set start time and end time of DST. Set according
DST
to data or week.
NTP Select to enable the function of network time sync.
NTP Server. Time server address.
Port Port number of time server.
Time Zone The time zone where the device is located.
Interval The sync interval between device and time server.
Click OK to finish configuration.
5.4.6.2 Account
5.4.6.2.1 Account
The system supports configuring operation user of WEB. You need to configure user group
before configuring user account.
WEB Client 76
Username
The user with Account control authority can also modify the password of other users.
It is recommended to give fewer authorities to normal users than premium users in order to
make user management convenient.
Cannot delete the user in the login status.
In this interface, it can add, delete or modify user.
Select Setting > System > Account > Account > Username.
The User interface is displayed. See Figure 5-69.
Username
Configure the parameters of dialog box. Please refer to Table 5-35 for more details.
Table 5-35 Add user parameters description
Parameter Note
WEB Client 77
Parameter Note
Username It can only consist of number, letter, underline and hyphen, the
Username maximum length contains 15 characters and it cannot be the same as the
existed username.
User’s password and confirm password.
Password The password can be set from 8 characters to 32 nonblank characters and
contains at least two types from capital letter, small letter, number and
special characters (excluding “'”, “"”, “;”, “:” and “&”)
Confirm
Follow the password security notice to set a high security level password.
Password
The new password should be in accordance with the confirm password.
User
Select the group that new users belong to. Each group has different authorities.
Group
Authority Select the authorities which belong to the user.
Click Save to finish configuration.
The newly added user is displayed in the user list.
After adding user, click to modify user password, group, memo and
authorities; click to delete the added user, admin user cannot be deleted.
Click in the admin row to modify user name and email address.
User Group
You have two groups named admin and user by default, you can add new group, delete added
group or modify group authority and memo.
Select Setting > System > Account > Account > Group Name.
The Group Name interface is displayed, see Figure 5-71.
The system supports max 8 user groups and the default initialization user groups
are admin and user.
You can modify and delete the added user group, but not the initialization user
group.
User Group
WEB Client 78
Add Group
Group Name can only consist of number, letter, underline and hyphen, the
maximum length contains 15 characters.
Group cannot be repeated.
Click Save to finish configuration.
The newly added group is displayed in the group list.
Click in the row of admin group or user group to modify group memo.
Onvif (Open Network Video Interface Forum), it can add, delete, modify Onvif in the user
management interface
Select “Setting > System > Account > ONVIF user”.
The ONVIF user interface is displayed, see Figure 5-73.
Configuring Onvif Users
WEB Client 79
Add user
Configure user parameters. For the detailed description, see Table 5-36.
Table 5-36 User parameter description
Parameter Note
Username User’s unique identification. You cannot use existing user name.
Password User’s password and confirm password.
The password can be set from 8 characters to 32 nonblank
characters and contains at least two types from capital letter,
small letter, number and special characters (excluding “'”, “"”,
“;”, “:” and “&”)
Confirm Password
Follow the password security notice to set a high security
level password.
The new password should be in accordance with the confirm
password.
The group that users belong to. Each group has different
Group
authorities.
Click Save to finish configuration.
The newly added user is displayed in the user list.
After adding user, click to modify user password, group, memo and
authorities; click to delete the added user, admin user cannot be deleted.
Click in the admin row to modify user name and email address.
5.4.6.3 Safety
5.4.6.3.1 IP Filter
In order to strengthen network security and protect device data, you can set the user who has
access to the device via IP filter.
Set trusted list mode: It only allows the user whose IP address exists in trusted list to log in
device.
WEB Client 80
Set banned list mode: The user whose IP address exists in banned list is forbidden to log in
device.
It fails to support enabling trusted list and banned list at the same time.
Select Setting > System > Safety > IP filter.
The IP Filter interface is displayed, see Figure 5-75.
IP Filter
2) Configure address information. Please refer to Table 5-37 for more details.
Table 5-37 Address parameter description
Parameter Note
IP Address Input the host IP address which needs to be added.
WEB Client 81
Select Trusted List and select some line in the list.
Click OK on the bottom of Trusted List tab. The system will prompt Successfully
saved.
You can also implement following operations in the Trusted List tab.
The setting method of banned list is similar to trusted list. Please make settings by referring to
the setting method of trusted list.
Select the system service which needs to be enabled according to actual requirement.
Select Setting > System > Safety > System Service.
The System Service interface is displayed. See Figure 5-78.
System Service
Select needed system service. Please refer to Table 5-38 for more details.
Table 5-38 System service parameters description
Parameter Note
SSH (Secure Shell) implements data encrypted transmission and
SSH
effectively avoid information leakage during remote management.
Multicast: It realizes point-to-multipoint network connection between
Multicast/Broadcast sender and receiver.
Search Broadcast: Broadcast data packet in IP subnet, all the hosts in the
subnet will receive these data packets.
When you forget the password of admin user, you can set new
Password Reset
password via password reset function.
WEB Client 82
Parameter Note
CGI Service CGI is the port between external application program and WEB server.
It realizes network video framework agreement to make different
Onvif Service
network video products interconnected.
Audio and Video
Transmission It needs to be encrypted during audio and video transmission.
Encryption
Click OK to finish configuration.
5.4.6.3.3 Https
You need to create server certificate and install root certificate if it is the first time to use
HTTPS or after changing device IP address.
After creating server certificate and installing root certificate, if it replaces the PC which
logs in WEB, then it needs to redownload and install root certificate on the new PC or copy
the downloaded root certificate on the new PC and install.
In the HTTPS setting interface, users can make PC log in normally via HTTPs by creating
certificate or uploading authenticated certificate. It can ensure security of communication data
and provide guarantee for user information and device safety via reliable and stable technical
approach.
Create certificate or upload the authenticated certificate
If you select Create Certificate, follow the steps below.
1) Select Setting > Network > Https.
The HTTPs interface is displayed. See Figure 5-79
HTTPS (1)
2) Click Create.
The HTTPs dialog box is displayed. See Figure 5-80.
WEB Client 83
HTTPS (2)
3) Enter the required information such as Country and IP/Domain Name etc. and then
click Create.
If the operation is correct, then the Create successful prompt is displayed.
The entered IP or Domain name must be the same as the IP or domain name of
the device.
4) Click Install, see Figure 5-81.
Certificate Installation
WEB Client 84
Download Root Certificate
WEB Client 85
7) Click Install Certificate.
The Certificate Import Wizard interface is displayed, see Figure 5-84.
Certificate import wizard
8) Click Next.
Select Trusted Root Certification Authorities, see Figure 5-85.
WEB Client 86
Certificate Store
9) Click Next.
The Completing the Certificate Import Wizard interface is displayed, see Figure
5-86.
WEB Client 87
Completing certificate import wizard
WEB Client 88
11) Click Yes.
The Import was successful dialog box is displayed, click OK to finish download,
see Figure 5-88.
Import succeeded!
2) Click “Browse” to upload the signed certificate and certificate key, and then click
Upload.
3) To install the root certificate, see operation steps from 5) to 11) in Create
Certificate.
Select Enable HTTPS and click OK.
Need to Reboot Device interface is displayed. Config takes effect.
Need to reboot device
WEB Client 89
Use HTTPs
WEB Client 90
Default setting
5.4.6.5 Import/Export
Export the system configuration file to backup the system configuration; Import system
configuration file to make quick configuration or recover system configuration.
Select Setting > System > Import/Export.
The Import/Export interface is displayed. See Figure 5-93.
Import/Export
WEB Client 91
Select Setting > System > Auto Maintain.
The Auto Maintain interface is displayed. See Figure 5-94.
Automatic Maintenance
Configure parameters according to actual requirement. Please refer to Table 5-39 for
more details.
Table 5-39 Auto maintain parameter description
Parameter Note
The system will automatically reboot within the set period and
Auto Reboot time.
Select and set reboot period and time.
Auto delete old files Customize time and delete all the old files before the time.
Reboot device Manual Reboot
Click OK to finish configuration.
Upgrading the wrong program might result in the device not working properly.
During upgrading, make sure the device is not disconnected from power and network, and
reboot or shut down the Web.
Upgrade device firmware.
Select Setting > System > Upgrade.
The Upgrade interface is displayed. See Figure 5-95.
WEB Client 92
Firmware Upgrade
5.4.7 Information
The system supports viewing version, user and log etc.
5.4.7.1 Version
In this section, it can view the version information of current WEB.
Select Setting > Information > Version, and the Version interface is displayed. See Figure
5-96.
Versions of different devices might vary, and the actual WEB interface shall prevail.
WEB Client 93
Version
5.4.7.2 Log
5.4.7.2.1 Log
The earliest log records will be covered when the number of log records reaches 2014.
In this interface, you can view log information such as system, config, data:, event, record, user
management and clear log etc.
Select Setting > Information > Log > Log.
The Log interface is displayed. See Figure 5-97.
Log
Enter Start Time and End Time, and then select log type.
Click Search and it can stop searching according to requirement.
View, backup and clear the searching result.
Backup: Backup the inquired system log information to local, the backup is .txt file.
WEB Client 94
Select Setting > Information > Log > Log.
The Remote Log interface is displayed. See Figure 5-98.
Remote Log
Alarm
Click the Alarm tab and the alarm tab is displayed. See Figure 5-100.
In this interface, you can select alarm type, operation and tone, view the alarm time, type and
channel. Please refer to Table 5-40 for more details.
Alarm
WEB Client 95
Table 5-40 Alarm parameters description
Type Parameter Parameters description
Storage Card Full It triggers alarm when storage card is full.
Storage Card Fault It triggers alarm when storage card fault occurs.
It generates alarm via peripheral device when alarm is
Peripheral Alarm
triggered.
Alarm Type
No Storage Card It triggers alarm when there is no storage card.
Plate Black List It triggers alarm when the blacklist vehicle appears.
It triggers alarm when the times of login password error
Illegal access
reach the max value.
Operation Listen Alarm The WEB will prompt user when device alarm occurs.
It generates alarm prompt tone when alarm occurs. Alarm
Play Alarm Tone
Alarm Tone tone supports customized setting
Tone Path The path of customized alarm tone.
Logout
Click Logout to exit the system. You need to log in again for access.
Login again
WEB Client 96
6 Technical Parameters
Table 6-1 Technical parameter table
Parameter
Parameter Name Value
Category
Model ITC215-PW4I-LZF27135, ITC215-PW4I- IRLZF27135
Sensor type 1/2.8 inch CMOS
Shutter 1/50~1/10000, auto or manual.
Scanning mode Progressive scanning
Exposure mode Supports full auto; customized auto; customize.
Camera
Supports full auto; color temperature auto; customized color
White balance
temperature
Edge enhance Supported
WDR Supported
Lens mount Φ14 (motorized vari-focal)
Lens Lens Focal Length 2.7mm~13.5mm
Iris Control Auto iris
Image
compression JPEG
standard
Image resolution 1920×1080 or 1280×720
Video
compression Standard H.264 high profile 5.0
Image standard
Video bit rate H.265 Or H.264 bit rate adjustable
PAL 25fps
Video frame rate
NTSC 30fps
Video resolution 1920×1080 or 1280×720
Saturation, brightness, contrast, white balance, gain, 3DNR
Image setting
can be adjusted via software, supports WDR.
I/O coil trigger Supported
RS-485 coil trigger Supported
Video detection Supported
Supports max 10,000 white list vehicles, and directly
links barrier output.
Black/white list
Supports max 10,000 black list vehicles, and generates
Trigger Mode
alarm event.
Vehicle recognition, plate recognition, vehicle color
Smart Recognition recognition, logo recognition, model recognition, series
recognition, head direction and vehicle features.
Remote control Implement remote config and control via WEB.
OSD info overlay Supported, it can customize time, location and plate etc.
Technical Parameters 97
Parameter
Parameter Name Value
Category
Image Tampering Supported, video/picture equipped with watermark and
proof verification function.
Built-in LED Built-in 6 LED lights NO, flash light brightness adjustable.
Network port 1 , 10M/100M Ethernet port
2, RS-485 port, used to externally connect to 485 devices
RS-485 port
such as vehicle detector, display screen and so on.
1, RS-485/232 signal switchable, used to externally connect
RS-485/232 port
to 485 or 232 device.
2, optocoupler input (switching value), used for vehicle
I/O input port
Interface detector signal input.
1, optocoupler input (switching value), used to trigger voice
Alarm input port
intercom and so on.
2 channel optocoupler output, 1 channel relay output; used
Relay-out
to link barrier and so on.
1 channel, connect to panoramic camera and used for scene
HDCVI port
monitoring.
Storage port Built-in 1 TF card port, supports max 64G.
Power supply DC 12V or POE802.3at
Power
<24W
Consumption
Working
﹣ 30℃~﹢65℃
temperature
General
Working humidity 10%~90%
Parameter
Enclosure
Plastic decoration accessory + die casting aluminum
material
Size (mm) 296.5×124×108
Weight 1.9kg
Protection level IP67
Technical Parameters 98
Table 7-1
7 FAQ
FAQ Measures
Device error. Failed to Press the Reset button for 5 seconds and make the device restore
normally operate or start. to default setting.
Please stop recording and snapshot before removing storage
card. Operation can be made after 15 seconds in order to
Storage card hot swap
guarantee data completeness; otherwise it may cause the danger
of data loss.
Please do not set the storage card as the storage media of
Write times limit of
scheduled record, otherwise it will rapidly reach the write longevity
storage card
and cause damage to the storage card.
Failed to use disk for When the storage card shows sleep mode or 0 capacity, please
storage first format it via WEB interface.
When network upgrade fails, the status indicator light shows red.
Network upgrade failed
At this moment, upgrade can be continued via port 3800.
Kingston 16GB, Kingston 32GB, Kingston 64GB, Dahua 16GB,
TF card recommended
Dahua 32GB, Dahua 64GB. It is recommended to use class 10
type
high capacity card, which supports max 128G TF card.
Failed to pop up the Please set the security level of IE browser as Low, Active Plug-in
installation dialog box of and Control is set as Enable.
WEB control
webrec.cab.
FAQ 99