0% found this document useful (0 votes)
124 views

GP-4402WW/GP-4502WW: Hardware Manual

Uploaded by

MP K
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
124 views

GP-4402WW/GP-4502WW: Hardware Manual

Uploaded by

MP K
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 62

GP-4402WW/GP-4502WW

Hardware Manual

GP4X02WW-MM01-EN-PDF_04
07/2021

www.pro-face.com
The information provided in this documentation contains general descriptions and/or technical
characteristics of the performance of the products contained herein. This documentation is not
intended as a substitute for and is not to be used for determining suitability or reliability of these
products for specific user applications. It is the duty of any such user or integrator to perform the
appropriate and complete risk analysis, evaluation and testing of the products with respect to the
relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or
subsidiaries (hereinafter, referred to as Schneider Electric) shall be responsible or liable for misuse
of the information that is contained herein. If you have any suggestions for improvements or
amendments or have found errors in this publication, please notify us.
You agree not to reproduce, other than for your own personal, noncommercial use, all or part of
this document on any medium whatsoever without permission of Schneider Electric, given in
writing. You also agree not to establish any hypertext links to this document or its content.
Schneider Electric does not grant any right or license for the personal and noncommercial use of
the document or its content, except for a non-exclusive license to consult it on an "as is" basis, at
your own risk. All other rights are reserved.
All pertinent state, regional, and local safety regulations must be observed when installing and
using this product. For reasons of safety and to help ensure compliance with documented system
data, only the manufacturer should perform repairs to components.
When devices are used for applications with technical safety requirements, the relevant
instructions must be followed.
Failure to use Schneider Electric software or approved software with our hardware products may
result in injury, harm, or improper operating results.
Failure to observe this information can result in injury or equipment damage.
Copyright © 2021 Schneider Electric Japan Holdings Ltd. All Rights Reserved.

2
GP-4402WW/GP-4502WW Hardware Manual

Table of Contents

Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
About the Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Chapter 1 GP-4402WW/GP-4502WW Panels . . . . . . . . . . . . . . . . 9
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Parts Identification and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Certifications and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
GP-4402WW/GP-4502WW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Chapter 2 Device Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
System Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Chapter 3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.1 General Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.2 Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Display Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Memory, Clock, and Touch Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.3 Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Serial Interface Specifications RS-232C . . . . . . . . . . . . . . . . . . . . . . . 31
Serial Interface Specifications RS-422/485 . . . . . . . . . . . . . . . . . . . . . 32
Ethernet Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.4 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
GP-4402WW Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
GP-4502WW Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Panel-cut Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Installation Fasteners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Chapter 4 Installation and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Real Time Clock (RTC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
4.2 Wiring Principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Connecting the Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Connecting the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
4.3 USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
USB Type A Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Chapter 5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Precaution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Periodic Check Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Regular Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
After-sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

3
4
GP-4402WW/GP-4502WW Hardware Manual

Safety Information

Important Information

NOTICE
Read these instructions carefully, and look at the equipment to become familiar with the device
before trying to install, operate, or maintain it. The following special messages may appear
throughout this documentation or on the equipment to warn of potential hazards or to call attention
to information that clarifies or simplifies a procedure.

PLEASE NOTE
Electrical equipment should be installed, operated, serviced, and maintained only by qualified
personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of
the use of this material.
A qualified person is one who has skills and knowledge related to the construction and operation
of electrical equipment and its installation, and has received safety training to recognize and avoid
the hazards involved.

5
6
GP-4402WW/GP-4502WW Hardware Manual

About the Book

At a Glance

Document Scope
This manual describes how to use this product.

Validity Note
This documentation is valid for this product.
The technical characteristics of the device(s) described in this manual also appear online at
http://www.pro-face.com/trans/in/manual/1053.html.
The characteristics presented in this manual should be the same as those that appear online. In
line with our policy of constant improvement we may revise content over time to improve clarity and
accuracy. In the event that you see a difference between the manual and online information, use
the online information as your reference.

Registered Trademarks
Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States
and/or other countries.
Product names used in this manual may be the registered trademarks owned by the respective
proprietors.

Related Documents
You can download the manuals related to this product, such as the software manual, from our
website at http://www.pro-face.com/trans/en/manual/1001.html.

Product Related Information


If the equipment is used in a manner not specified by the manufacturer, the protection provided by
the equipment may be impaired.

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
 Disconnect all power from all equipment including connected devices before removing any
covers or doors, or installing or removing any accessories, hardware, cables, or wires except
under the specific conditions specified in the appropriate hardware guide for this equipment.
 Always use a properly rated voltage sensing device to confirm that the power is off.
 Unplug the power cable from both the equipment and the power supply.
 Replace and secure all covers, accessories, hardware, cables, and wires and confirm that a
proper ground connection exists before applying power to the equipment.
 Use only the specified voltage when operating this equipment and any associated products.
Failure to follow these instructions will result in death or serious injury.

7
WARNING
LOSS OF CONTROL
 Consider the potential failure modes of control paths in the machine control system design,
such as:
 the possibility of backlight failure,
 unanticipated link transmission delays or failures,
 the operator being unable to control the machine,
 the operator making errors in the control of the machine.

 Provide a means to achieve a safe state during and after a path failure for critical control
functions such as emergency stop and overtravel stop.
 Provide separate or redundant control paths for critical control functions.
 Test individually and thoroughly each implementation of the panel for correct operation before
service.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

WARNING
UNINTENDED EQUIPMENT OPERATION
 Only use software approved by Schneider Electric for use with this equipment.
 Update your application program every time you change the physical hardware configuration.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

8
GP-4402WW/GP-4502WW Hardware Manual
GP-4402WW/GP-4502WW Panels
GP-4402WW4502WW_EN 12/2016

GP-4402WW/GP-4502WW Hardware Manual

Chapter 1
GP-4402WW/GP-4502WW Panels

GP-4402WW/GP-4502WW Panels

Overview
This chapter describes the series of panels and connectable devices.

What Is in This Chapter?


This chapter contains the following topics:
Topic Page
Package Contents 10
Parts Identification and Functions 11
Certifications and Standards 13
GP-4402WW/GP-4502WW 14

9
GP-4402WW/GP-4502WW Panels

Package Contents

Overview
Make sure that all applicable items listed here are included in your package:

1 GP-4402WW (PFXGP4402WADW) or GP-4502WW (PFXGP4502WADW) x 1


2 Installation Gasket (attached to the panel)
3 DC power connector
4 Screw installation fasteners (GP-4402WW x 4, GP-4502WW x 6)
5 GP-4402WW/GP-4502WW Installation Guide
6 Warning/Caution Information

Revision
You can identify the product version (PV), revision level (RL), and the software version (SV) from
the product label.
This diagram is a representation of a typical label:

10
GP-4402WW/GP-4502WW Hardware Manual

Parts Identification and Functions

Front View

GP-4402WW GP-4502WW

Part Description
A Touch panel
B LED indicator

Rear View

GP-4402WW GP-4502WW

Part Description
C USB mini B
D Locker USB Type A
E Screw installation fasteners:
 GP-4402WW x 4
 GP-4502WW x 6

11
GP-4402WW/GP-4502WW Panels

Bottom View

GP-4402WW GP-4502WW

Part Description
F Power connector
G Serial interface RS-232C
H Serial interface RS-422/485
I Ethernet
J USB Type A

12
GP-4402WW/GP-4502WW Hardware Manual

Certifications and Standards

Compliance Standards
Schneider Electric submitted this product for independent testing and qualification by third party
listing agencies.
These agencies have certified this product as meeting the following standards:
Europe:
CE
 Directive (2014/30/EU) (EMC)
 Programmable Controllers: EN 61131-2
 EN61000-6-4
 EN61000-6-2

Qualification Standards
Schneider Electric voluntarily tested this product to additional standards. The additional tests
performed, and the standards under which the tests were conducted, are specifically identified in
Environmental Characteristics (see page 22).

Hazardous Substances
This product is a device for use in factory systems. When using this product in a system, the system
should comply with the following standards in regards to the installation environment and handling:
 RoHS, Directive 2011/65/EU
 RoHS China, Standard GB/T 26572
 REACH regulation EC 1907/2006

Hazardous Location

DANGER
RISK OF EXPLOSION IN HAZARDOUS LOCATION
Do not use this product in hazardous location.
Failure to follow these instructions will result in death or serious injury.

European (CE) Compliance


The product described in this manual comply with the European Directives concerning
Electromagnetic Compatibility and Low Voltage (CE marking) when used as specified in the
relevant documentation, in application for which they are specifically intended, and in connection
with approved third-party products.

13
GP-4402WW/GP-4502WW Panels

GP-4402WW/GP-4502WW

Introduction
This topic presents the GP-4402WW/GP-4502WW human-machine interface (HMI) products. The
features of the screen technology are color and TFT (Thin Film Transistors also known as active
matrix) with WVGA pixel resolution. The operating voltage is 24 Vdc. The products offered in this
series have various features and benefits listed below:
 Screen size
 RTC battery
 Communication interfaces

Model Number Configuration


The following describes the configuration of model numbers.

Digit 1 2 3 4 5 6 7 8 9 10 11 12 13
Position
P F X (model) (series) (size) (type) (LCD) (touch (power -
panel) supply)
GP 4 4: 7” 02: RS-232C W: Wide A: D: DC W: Entry
5: 10” and RS-422/485 TFT Analog model
are available

Model Numbers

Series Model Names Model Numbers


GP4000 Series GP-4400 Series GP-4402WW PFXGP4402WADW
GP-4500 Series GP-4502WW PFXGP4502WADW

Global Code
A global code is assigned to every Pro-face product as a universal model number. For more
information on product models and their matching global codes, please refer to the following URL.
http://www.pro-face.com/trans/en/manual/1003.html

Critical Systems, Alarms, and Handling Requirements


Critical alarm indicators and system functions require independent and redundant protection for
hardware and/or mechanical interlocks.
When you cycle power, wait at least 1 second before restoring the power to the panel after it has
been turned off. Switching the power OFF and ON quickly can damage the panel.
In the event the screen cannot be properly read, for example, if the backlight is not functioning, it
may be difficult or impossible to identify a function. Functions that may present a hazard if not
immediately executed, such as a fuel shut-off, must be provided independently of the panel. The
design of the control system of the machine must take into account the possibility of the backlight
no longer functioning and the operator being unable to control the machine or making mistakes in
the control of the machine.

14
GP-4402WW/GP-4502WW Hardware Manual

WARNING
LOSS OF CONTROL
 Consider the potential failure modes of control paths in the machine control system design,
such as:
 the possibility of backlight failure,
 unanticipated link transmission delays or failures,
 the operator being unable to control the machine,
 the operator making errors in the control of the machine.

 Provide a means to achieve a safe state during and after a path failure for critical control
functions such as emergency stop and overtravel stop.
 Provide separate or redundant control paths for critical control functions.
 Test individually and thoroughly each implementation of the panel for correct operation before
service.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

WARNING
UNINTENDED EQUIPMENT OPERATION
 Do not use this equipment as the only means of control for critical system functions such as
motor start/stop or power control.
 Do not use this equipment as the only notification device for critical alarms, such as device
overheating or overcurrent.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

Handling the LCD Panel


The following characteristics are specific to the LCD panel and are considered normal behavior:
 LCD screen may show unevenness in the brightness of certain images or may appear different
when seen from outside the specified viewing angle. Extended shadows, or crosstalk may also
appear on the edges of screen images.
 LCD screen pixels may contain black and white-colored spots and the color display may look as
if it is changing.
 When the same image is displayed on the panel screen for a long period, an after-image may
appear after changing the image. If this happens, turn OFF the panel, wait 1 second, and then
restart the panel.
 The panel brightness may decrease when used for a long time in an environment continuously
filled with inert gas. To prevent deterioration of panel brightness, regularly ventilate the panel.
For more information, please contact customer support.
http://www.pro-face.com/trans/in/manual/1015.html
NOTE: Change the screen image periodically and try not to display the same image for a long
period time.

15
GP-4402WW/GP-4502WW Panels

CAUTION
SERIOUS EYE AND SKIN INJURY
The liquid in the LCD panel contains an irritant:
 Avoid direct skin contact with the liquid.
 Wear gloves when you handle a broken or leaking unit.
 Do not use sharp objects or tools in the vicinity of the LCD touch panel.
 Handle the LCD panel carefully to prevent puncture, bursting, or cracking of the panel material.

Failure to follow these instructions can result in injury or equipment damage.

If the panel is damaged and any liquid comes in contact with your skin, immediately rinse the area
with running water for at least 15 minutes. If the liquid gets in your eyes, immediately rinse your
eyes with running water for at least 15 minutes and consult a doctor.

Cybersecurity Best Practices


To help keep your Pro-face products secure and protected, we recommend that you implement the
cybersecurity best practices. Following the recommendations may help significantly reduce your
company's cybersecurity risk. For the recommendations, refer to the following URL:
https://www.pro-face.com/trans/en/manual/1087.html

16
GP-4402WW/GP-4502WW Hardware Manual
Device Connectivity
GP-4402WW4502WW_EN 12/2016

GP-4402WW/GP-4502WW Hardware Manual

Chapter 2
Device Connectivity

Device Connectivity

Overview
This chapter presents the equipment that you can connect to the GP-4402WW/GP-4502WW.

What Is in This Chapter?


This chapter contains the following topics:
Topic Page
System Design 18
Accessories 19

17
Device Connectivity

System Design

Introduction
The following diagram presents the most common equipment you can connect to the panel.

*1 Refer to Accessories (see page 19).


*2 For information on how to connect controllers and other types of equipment, refer to the
corresponding device driver manual of your screen editing software.
*3 For supported models, refer to our support site
http://www.pro-face.com/trans/in/manual/1053.html.

18
GP-4402WW/GP-4502WW Hardware Manual

Accessories

Serial Interface Items


For host controllers and connection cables, refer to the corresponding device driver manual of your
screen editing software.

USB Interface Items

Product name Model number Description


USB-Serial (RS-232C) CA6-USB232-01 Cable for converting a USB interface into a serial
Conversion Cable (0.5 m) interface (RS-232C). Allows connection to modems*1
or bar code readers*1 that support RS-232C.
USB Transfer Cable (USB ZC9USCBMB1 Cable for transferring screen data from a PC (USB
Type A/mini-B) (1.8 m) Type A) to this product (USB mini-B).
EZ Illuminated Switch PFXZCCEUSG1 A unit of 5 illuminated switches with multiple color
LED connected to this product via USB.
EZ Fingerprint Recognition PFXZCCEUSS1 Fingerprint recognition unit connected to this product
Unit via USB.
EZ Numpad PFXZCCEUKB1 Numpad connected to this product via USB.
EZ Tower Light tube PFXZCETWHA1 USB Connection Type Monolithic EZ Tower Light
mounting with fixing plate tube mounting with fixing plate.
3 tiers, Ø60, lighting and flashing with a buzzer.
EZ Tower Light with base PFXZCETWW1 USB Connection Type Monolithic EZ Tower with
mounting base mounting.
3 tiers, Ø60, lighting and flashing with a buzzer.

*1 For supported models, refer to our support site


http://www.pro-face.com/trans/in/manual/1053.html.

Option Items

Product name Model number Description


7.0-inch Wide Screen PFXZCBDS72 Disposable, dirt-resistant sheet for the display
Protection Sheet (5 sheets/set).
7-inch Wide UV Protection PFXZCFUV72 Ultraviolet protection for display (1 piece).
Sheet
10-inch Wide UV PFXZCFUV102
Protection Sheet
Battery for Data Backup PFXZGEBT1 Primary battery for time data backup (1 piece).

19
Device Connectivity

Maintenance Options

Product name Model number Description


Installation Fastener PFXZCFAF1 Used to install this product into a solid panel
(4 pieces/set).
DC Power Supply CA5-DCCNM-01 Connector to connect power supply cables
Connector (5 pieces/set).
7-inch Wide Installation PFXZCCWG7W1 Provides dust and moisture resistance when this
Gasket product is installed into a solid panel (1 piece).
10-inch Wide Installation PFXZCCWG10W1
Gasket

20
GP-4402WW/GP-4502WW Hardware Manual
Specifications
GP-4402WW4502WW_EN 12/2016

GP-4402WW/GP-4502WW Hardware Manual

Chapter 3
Specifications

Specifications

Overview
This chapter presents the GP-4402WW/GP-4502WW specifications.

What Is in This Chapter?


This chapter contains the following sections:
Section Topic Page
3.1 General Specifications 22
3.2 Functional Specifications 25
3.3 Interface Specifications 28
3.4 Dimensions 35

21
Specifications

Section 3.1
General Specifications

General Specifications

Specifications

Specification Value
Rated input voltage 24 Vdc
Input voltage limits 20.4...28.8 Vdc
Acceptable voltage drop ≤ 1 ms with lowest input voltage
≤ 10 ms with rated input voltage
Power supply

Power consumption GP-4402WW: 9.2 W


GP-4502WW: 10 W
In-rush current ≤ 50 A 1
Voltage endurance between power 1000 Vac 5 mA for 1 min
terminal and functional ground (FG)
Insulation resistance between power 10 MΩ or higher at 500 Vdc
terminal and FG.
Ambient operating temperature 0...50 °C (32...122 °F)
(cabinet interior and panel face)
Storage temperature -20...60 °C (-4...140 °F)
Relative humidity ≤ 90 % non-condensing
Physical

Air purity (dust) ≤ 0.1 mg/m3 (3.5-6 oz/ft3) (non-conductive levels)


Pollution degree 2
Corrosive gases Free of corrosive gases
Atmospheric pressure 800...1,114 hPa (2,000 m (6,561 ft) or less)
Vibration immunity IEC 61131-2 ed.3 (07)
Mechanical

5...150 Hz, 3.5 mm (0.38 in) max., 1 g on 3 axes.


Shock immunity IEC 61131-2 ed.3 (07)
1/2 sinusoidal pulse for 11 ms, 15 g on 3 axes
Cooling method Natural air circulation
Protection (front panel) IP 65 - (IEC 60529)
Structural

Protection (rear panel) IP 20 - (IEC 60529)

1 For in-rush current, the FWHM (full-width, half maximum) value is approximately 50 μs (when exceeding 25 A).

22
GP-4402WW/GP-4502WW Hardware Manual

Specification Value
Radiated radio frequency 10 V/m / 80 MHz...1 GHz, 3 V/m / 1.4 MHz...2 GHz, 1 V/m /
electromagnetic field 2 GHz...3 GHz, sinus amplitude modulated 80 % / 1 kHz and
internal clock frequency
Electrical fast transient EN/IEC 61131-2 zone B
Electrical

2 kV power supply and 1 kV shielded cables


High energy surges IEC 61000 - 4 - 5
0.5 kV (Differential mode on power supply)
1 kV (Common mode on power supply)
Electrostatic discharge immunity EN/IEC 61131-2
4 kV contact, 8 kV air
1 For in-rush current, the FWHM (full-width, half maximum) value is approximately 50 μs (when exceeding 25 A).

The front face of the panel, installed in a solid panel, has been tested using conditions equivalent
to the standards shown in the specification.

CAUTION
EQUIPMENT DAMAGE
 Ensure that the panel is not in permanent and direct contact with oils.
 Do not expose the device to direct sunlight.
Failure to follow these instructions can result in injury or equipment damage.

NOTICE
STORAGE AND OPERATION OUTSIDE OF SPECIFICATIONS
 Store this product in areas where temperatures are within the product’s specifications.
 Do not restrict or block this product’s ventilation slots.
Failure to follow these instructions can result in equipment damage.

NOTICE
GASKET AGING
 Inspect the gasket periodically as required by your operating environment.
 Change the gasket at least once a year, or as soon as scratches or dirt become visible.
Failure to follow these instructions can result in equipment damage.

23
Specifications

Air Quality Requirements


Do not operate or store the panel where any of the following chemicals may evaporate or where
these chemicals are present in the air:
 Corrosive chemicals such as acids, alkalines, and liquids containing salt.
 Flammable chemicals such as organic solvents.

CAUTION
INOPERATIVE EQUIPMENT
Do not allow water, liquids, metal, and wiring fragments to enter the panel case.
Failure to follow these instructions can result in injury or equipment damage.

24
GP-4402WW/GP-4502WW Hardware Manual

Section 3.2
Functional Specifications

Functional Specifications

Overview
This section presents the GP-4402WW/GP-4502WW functional specifications of the display,
memory, and interfaces.

What Is in This Section?


This section contains the following topics:
Topic Page
Display Specifications 26
Memory, Clock, and Touch Panel 27

25
Specifications

Display Specifications

Displays

Specification GP-4402WW GP-4502WW


Type TFT color LCD
Display size 7” 10”
Resolution (pixels) 800 x 480 800 x 480
(WVGA) (WVGA)
Active display area 154.08 x 85.92 mm 219.6 x 131.76 mm
(W x H) (6.066 x 3.382 in) (8.645 x 5.187 in)
Colors 65,536 colors
For details about display colors, refer to the manual for your screen
editing software.
Backlight While LED (Not user replaceable. When replacement is required,
contact customer support.)
Backlight service life 20,000 hours or more (continuous operation at 25 °C [77 °F] before
backlight brightness decreases to 50 %)
NOTE: To extend the life of the backlight set the panel to standby
mode, which automatically turns off the backlight when no touch input
is detected within a set time.
Brightness 16 levels available through the touch panel

26
GP-4402WW/GP-4502WW Hardware Manual

Memory, Clock, and Touch Panel

Memory
This table describes the memory parameters:

Specification GP-4402WW/GP-4502WW
User application 32 MB
Backup memory 128 KB

Clock
Variations in operating conditions and battery life can cause a clock inaccuracy from -60 seconds
to +60 seconds per month.
For systems where this level of precision is insufficient, the user should monitor and make
adjustments when required.

Touch Panel

Specification GP-4402WW/GP-4502WW
Type Resistive Film (analog)
Resolution 1,024 x 1,024
Service life 1 million switch and 100 thousand slide operations

Multiple touch operations on models with analog-resistive touch panels may cause unexpected
inputs around touched positions.

WARNING
UNINTENDED EQUIPMENT OPERATION
Do not simultaneously touch two or more points on the panel.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

27
Specifications

Section 3.3
Interface Specifications

Interface Specifications

Overview
This section presents the interface specifications of the panels.

What Is in This Section?


This section contains the following topics:
Topic Page
Interface Specifications 29
Serial Interface Specifications RS-232C 31
Serial Interface Specifications RS-422/485 32
Ethernet Port 33

28
GP-4402WW/GP-4502WW Hardware Manual

Interface Specifications

Introduction
GP-4402WW/GP-4502WW is provided with serial, USB, and Ethernet interfaces.
Use only the SELV (Safety Extra-Low Voltage) circuit to connect the serial, USB, and LAN
interfaces.

Serial Interface RS-232C


This table describes the RS-232C serial interface:

Interface Description
Serial interface D-Sub9
Asynchronous transmission RS-232C
Data length 7 bits or 8 bits
Stop bit 1 bit or 2 bits
Parity None, odd or even
Data transmission speed 2,400...115,200 bps

Serial Interface RS-422/485


This table describes the RS-422/485 serial interface:

Interface Description
Serial interface D-Sub9
Asynchronous transmission RS-422/485
Data length 7 bits or 8 bits
Stop bit 1 bit or 2 bits
Parity None, odd or even
Data transmission speed 2,400...115,200 bps, 187,500 bps (MPI)

USB Interface (USB Peripherals)


This table describes the USB Type A interface:

Interface Description
Host interface
Maximum current supplied 500 mA
Maximum transmission distance 3 m (9.84 ft) at 1.5/12/480 Mbps
Connector USB Type A 2.0

USB Interface (Application Download)


This table describes the USB mini-B interface:

Interface Description
USB interface is used for application download
Maximum transmission distance 3 m (9.84 ft) at 12 Mbps, no long-term connections
Connector USB mini-B 2.0
Isolated None

29
Specifications

Ethernet Interface
Refer to Ethernet Port (see page 33).

30
GP-4402WW/GP-4502WW Hardware Manual

Serial Interface Specifications RS-232C

Introduction
This interface is used to connect GP-4402WW/GP-4502WW to remote equipment, via a RS-232C
cable. The connector used is a D-Sub 9-pin male connector.
By using a long PLC cable to connect to the panel, it is possible that the cable can be at a different
electrical potential than the panel, even if both are grounded.
The serial port of the panel is not isolated. The SG (signal ground) and the FG (functional ground)
terminals are separated inside the panel.

DANGER
ELECTRIC SHOCK
 Make a direct connection between the functional ground (FG) terminal and ground.
 Do not connect other devices to ground through the functional ground (FG) terminal of this
device.
 Install all cables according to local codes and requirements. If local codes do not require
grounding, follow a reliable guide such as the US National Electrical Code, Article 800.
Failure to follow these instructions will result in death or serious injury.

Serial Interface RS-232C


This table describes COM1 with its D-Sub 9-pin connector for a RS-232C cable.

Pin connection Pin Signal name Meaning


1 CD Carrier Detect
2 RD(RXD) Receive Data
3 SD(TXD) Send Data
4 ER(DTR) Data Terminal Ready
5 SG Signal Ground
6 DR(DSR) Data Set Ready
7 RS(RTS) Request to Send
8 CS(CTS) Send possible
9 Reserved –
Shell FG Functional Ground

Any excessive weight or stress on communication cables disconnect communication with the
equipment.

CAUTION
LOSS OF COMMUNICATION
 All connections to the communication ports must not put excessive stress on the ports.
 Securely attach communication cables to the panel or cabinet.
 Use only D-Sub 9-pin cables with a locking system in good condition.
Failure to follow these instructions can result in injury or equipment damage.

31
Specifications

Serial Interface Specifications RS-422/485

Introduction
This interface is used to connect GP-4402WW/GP-4502WW to remote equipment, via a RS-
422/485 cable. The connector used is a D-Sub 9-pin male connector.
By using a long PLC cable to connect to the panel, it is possible that the cable can be at a different
electrical potential than the panel, even if both are grounded.
The serial port of the panel is not isolated. The SG (signal ground) and the FG (functional ground)
terminals are separated inside the panel.

DANGER
ELECTRIC SHOCK
 Make a direct connection between the functional ground (FG) terminal and ground.
 Do not connect other devices to ground through the functional ground (FG) terminal of this
device.
 Install all cables according to local codes and requirements. If local codes do not require
grounding, follow a reliable guide such as the US National Electrical Code, Article 800.
Failure to follow these instructions will result in death or serious injury.

Serial Interface RS-422/485


This table describes COM2 with its D-Sub 9-pin connector for a RS-422/485 cable.

Pin connection Pin Signal name Meaning


1 RDA Receive Data A (+)
2 RDB Receive Data B (-)
3 SDA Send Data A (+)
4 –
5 SG Signal Ground
6 –
7 SDB Send Data B (-)
8 –
9 –
Shell FG Functional Ground

Any excessive weight or stress on communication cables may disconnect communication with the
equipment.

CAUTION
LOSS OF COMMUNICATION
 All connections to the communication ports must not put excessive stress on the ports.
 Securely attach communication cables to the panel or cabinet.
 Use only D-Sub 9-pin cables with a locking system in good condition.
Failure to follow these instructions can result in injury or equipment damage.

32
GP-4402WW/GP-4502WW Hardware Manual

Ethernet Port

Introduction
The GP-4402WW/GP-4502WW is equipped with an IEEE802.3 compliant Ethernet
communication port that transmits and receives data at 10 Mbps or 100 Mbps.
NOTE:
 Ethernet networks must be installed by a trained and qualified person.
 One to one (1:1) connections must be made with a hub or a switch. You can use the 1:1
connection with a cross cable depending on the connected PCs and network cards.

Characteristics
The table describes the different Ethernet characteristics:

Characteristics Description
Connector type RJ45
Driver  10 M half duplex (auto negotiation)
 100 M full duplex (auto negotiation)

Cable type Shielded


Automatic cross-over Yes
detection

Pin Assignment
The figure shows the RJ45 Ethernet connector pin assignment:

The table describes the RJ45 Ethernet connector pins:

Pin Signal
1 TD+
2 TD-
3 RD+
4 –
5 –
6 RD-
7 –
8 –

NOTE: The GP-4402WW/GP-4502WW supports the MDI/MDIX auto-crossover cable function.


You do not have to use special Ethernet crossover cables to connect devices directly to this port
(connections without an Ethernet hub or switch).

33
Specifications

Status LEDs
The figure shows the LEDs of the Ethernet connector:

The table describes the Ethernet status LEDs operation:

Label Description LED


Color Status Description
IND1 Ethernet status Green Off No connection or subsequent
transmission failure.
On Data transmission is available.
IND2 Ethernet activity Green Off No data transmission.
On Data transmission is occurring.

34
GP-4402WW/GP-4502WW Hardware Manual

Section 3.4
Dimensions

Dimensions

Overview
This section presents the dimensions of GP-4402WW/GP-4502WW.

What Is in This Section?


This section contains the following topics:
Topic Page
GP-4402WW Dimensions 36
GP-4502WW Dimensions 37
Panel-cut Dimensions 39
Installation Fasteners 40

35
Specifications

GP-4402WW Dimensions

Panel Dimensions

Dimensions with Cables

Dimensions with Installation Fasteners

36
GP-4402WW/GP-4502WW Hardware Manual

GP-4502WW Dimensions

Panel Dimensions

Dimensions with Cables

37
Specifications

Dimensions with Installation Fasteners

38
GP-4402WW/GP-4502WW Hardware Manual

Panel-cut Dimensions

Inserting a GP-4402WW/GP-4502WW
Create a panel-cut and insert the panel from the front. This figure shows the panel-cut for the GP-
4402WW/GP-4502WW:

Dimensions
The following table shows the panel-cut dimensions for each panel:

Model A B C (Panel thickness) R


GP-4402WW ±1
190 mm 135 ±0.7
mm 1...5 mm 3 mm
(7.48±0.04 in) (5.31±0.03 in) (0.04...0.19 in) (0.12 in) max.

GP-4502WW 255±1 mm 185+1 mm 1...5 mm 3 mm


(10.04±0.04 in) (7.28+0.04 in) (0.04...0.19 in) (0.12 in) max.

39
Specifications

Installation Fasteners

Introduction
The fasteners are used to mount the GP-4402WW/GP-4502WW:

Model Screw installation fasteners


GP-4402WW 4
GP-4502WW 6

Dimensions

40
GP-4402WW/GP-4502WW Hardware Manual
Installation and Wiring
GP-4402WW4502WW_EN 12/2016

GP-4402WW/GP-4502WW Hardware Manual

Chapter 4
Installation and Wiring

Installation and Wiring

Overview
This chapter describes the installation procedures and wiring principles for GP-4402WW/GP-
4502WW.

What Is in This Chapter?


This chapter contains the following sections:
Section Topic Page
4.1 Installation 42
4.2 Wiring Principles 49
4.3 USB Port 55

41
Installation and Wiring

Section 4.1
Installation

Installation

Overview
This section describes the installation procedures for GP-4402WW/GP-4502WW.

What Is in This Section?


This section contains the following topics:
Topic Page
Installation Procedures 43
Real Time Clock (RTC) 47

42
GP-4402WW/GP-4502WW Hardware Manual

Installation Procedures

Introduction
This product is designed for use on flat surfaces of Type 1 enclosure, or IP65.
Be aware of the following when building this product into an end-use product:
 The rear face of this product is not approved as an enclosure. When building this product into
an end-use product, be sure to use an enclosure that satisfies standards as the end-use
product’s overall enclosure.
 Install this product in an enclosure with mechanical rigidity.
 This product is not designed for outdoor use. UL certification obtained is for indoor use only.
 Install and operate this product with its front panel facing outward.

The installation gasket and screw fasteners are required when installing the panel.
Mount the panel in an enclosure that provides a clean, dry, robust, and controlled environment
(IP65 enclosure).
NOTE:
 The protection level of the product may vary from that shown on the label, as the value on the
label considers product aging.
 IP65 is not part of the UL certification.

Gasket Setup Requirements


The gasket helps to maintain the protection ratings (IP65, IP20) of the panel, and provides
additional protection from vibration.
An old gasket can lose its dust and drip resistance. Changing the gasket once a year or when
scratches or dirt become visible is recommended.

Step Action
1 Before installing the panel into a cabinet, check that the installation gasket is securely attached
to the panel.
2 A gasket that has been used for a long period may have scratches or dirt on its surface, and
could have lost much of its dust and drip resistance. Change the gasket once a year or when
scratches or dirt become visible.
3 Make sure that the gasket is inserted into the bottom face of the panel.

Panel Setup Procedure

Step Action
1 Check that the installation panel or the surface of the cabinet is flat, in good condition and has
no jagged edges. Metal reinforcing strips may be attached to the inside of the panel wall, near
the panel-cut, to increase the rigidity of the panel.
2 Decide on the installation of the thickness of the panel based on the level of panel strength
required: 1 mm (0.04 in) to 5 mm (0.19 in).
3 Be sure that the ambient operation temperature and the ambient humidity are within their
designated ranges. (When installing the panel in a cabinet or enclosure, the ambient operation
temperature is the internal temperature of the cabinet or enclosure.)
4 Be sure that heat from surrounding equipment does not cause the panel to exceed its standard
operating temperature (see page 22).

43
Installation and Wiring

Step Action
5 When mounting this product vertically, ensure that the right side of this product faces up. In other
words, the DC power connector should be at the top.

1 Power connector
6 When installing the panel in a slanted position, the panel face should not incline more than 30°:

When installing the panel in a slanted position, and the panel face inclines more than 30°, the
ambient temperature must not exceed 40 °C (104 °F). You may need to use forced air cooling
(fan, A/C) to ensure that the ambient operating temperature is 40 °C or below.
7 For easier maintenance, operation and improved ventilation, install the panel at least 100 mm
(3.94 in) away from adjacent structures and other equipment:

44
GP-4402WW/GP-4502WW Hardware Manual

Pressure Differences
When applying and installing this product, it is important that steps are taken to eliminate any
pressure difference between the inside and the outside of the enclosure in which this product is
mounted. Higher pressure inside the enclosure can cause delamination of the front membrane of
the display. Even a small pressure difference inside the enclosure will act on the large area of the
membrane and can result in sufficient force to delaminate the membrane and thus cause failure of
the touch capability. Pressure differences can often occur in applications where there are multiple
fans and ventilators moving air at different rates in different rooms. Please follow these techniques
to ensure that this product's function is not impacted by this mis-application:
1. Seal all conduit connections inside of the enclosure, especially those that lead to other rooms
that may be at a different pressure.
2. Where applicable, install a small weep hole at the bottom of the enclosure to allow equalization
of the internal and external pressure.

Panel Mounting Procedure

NOTICE
PANEL UNSTEADY WHEN UNSECURED
Keep panel stabilized in the panel-cut while you are installing or removing the screw fasteners.
Failure to follow these instructions can result in equipment damage.

Step Action
1 Place the panel on a clean and level surface with the display face pointing downward.
2 Check that the installation gasket of the panel is seated securely and runs all the way around
the perimeter of the frame.
3 Create the correct sized opening required to install the panel, using the installation dimensions
(see page 39).
4 Insert the panel into the panel-cut.
5 Insert the installation fasteners into the panel‘s insertion slots on the left and right sides (and on
the top and bottom sides of the GP-4502WW):

45
Installation and Wiring

Step Action
6 Slide the fasteners flat against the panel. If the fasteners are not correctly attached, the panel
may shift or fall out:

7 Use a Phillips screwdriver to tighten each fastener and secure the panel in place. The necessary
torque is 0.8 N·m (7.08 lb-in) maximum:

NOTICE
BROKEN ENCLOSURE
Do not exert more than 1 N•m (8.85 lb-in) of torque when tightening the fastener’s screws.
Failure to follow these instructions can result in equipment damage.

46
GP-4402WW/GP-4502WW Hardware Manual

Real Time Clock (RTC)

Overview
GP-4402WW/GP-4502WW includes a RTC to provide system date and time information, and to
support related functions requiring a real-time clock. To keep time continuity when power is off, a
non-rechargeable but replaceable battery is provided with GP-4402WW/GP-4502WW.
NOTE: After power is disconnected, the GP-4402WW/GP-4502WW cannot retain the time when
you change the RTC battery.

Installing and Replacing the RTC Battery


While lithium batteries are preferred due to their slow discharge and long life, they can present
hazards to personnel, equipment, and the environment, and must be handled properly.

DANGER
EXPLOSION, FIRE, OR CHEMICAL HAZARD
Follow these instructions for the lithium batteries:
 Use this product’s replacement battery only.
 Remove all replaceable batteries before discarding panel.
 Recycle or properly dispose of used batteries.
 Protect battery from any potential short circuit.
 Do not recharge, disassemble, heat above 80 °C (176 °F), or incinerate.
 Use your hands or insulated tools to remove or replace the battery.
 Maintain proper polarity when inserting and connecting a new battery.

Failure to follow these instructions will result in death or serious injury.

NOTE: Use only the replacement battery (model number PFXZGEBT1).


To install or replace the RTC battery, follow these steps:

Step Action
1 Power off your panel.
2 Open the cap to access the backup battery compartment as shown:

1 Safety alert symbol (see the safety messages above)


3 Remove the used battery from the compartment.
4 Insert the new battery in the compartment in accordance with the polarity markings in the
compartment and on the battery.
5 Close the cap.
6 Power up your GP-4402WW/GP-4502WW.
NOTE: If you do not power up your GP-4402WW/GP-4502WW immediately, the external
backup battery life might be reduced.

47
Installation and Wiring

Step Action
7 Set the internal clock. For further details on the internal clock, refer to your screen editing
software manual on how to set up the clock.

A lithium battery life is:


 3 years when the battery's ambient temperature is ≤ 40 °C (104 °F).
 3 years when the panel's ambient temperature is ≤ 25 °C (77 °F).

48
GP-4402WW/GP-4502WW Hardware Manual

Section 4.2
Wiring Principles

Wiring Principles

Overview
This section presents GP-4402WW/GP-4502WW wiring principles.

What Is in This Section?


This section contains the following topics:
Topic Page
Connecting the Power Cord 50
Connecting the Power Supply 52
Grounding 54

49
Installation and Wiring

Connecting the Power Cord

Introduction
Follow these instructions when supplying power to the panel.
 When the functional ground (FG) terminal is connected, be sure that the wire is grounded. If not
grounded, the panel can result in excessive Electromagnetic Interference (EMI). Grounding is
required to meet EMC level immunity.
 The shield ground (SG) and FG terminals are connected internally in the panel.
 Disconnect the power before wiring the panel's power terminals.
 The panel uses only 24 Vdc power. Using any other level of power can damage both the power
supply and the panel.
 Since the panel is not equipped with a power switch, be sure to connect a power switch to the
panel’s power supply.
 Be sure to ground the panel's FG terminal.

Power Cord Preparation


 Make sure that the ground wire is either the same or heavier gauge than the power wires.
 Do not use aluminum wires in the power supply's power cord.
 If the ends of the individual wires are not twisted correctly, the wires may create a short circuit.
To avoid this, use D25CE/AZ5CE cable ends.
 Wherever possible, use wires that are 0.75 to 2.5 mm2 (AWG 18 - 12) for the power cord, and
twist the wire ends before attaching the terminals.
 The conductor type is solid or stranded wire.

Power Plug Description

Pin connection Pin Wire


+ 24 Vdc
- 0 Vdc
FG Grounded terminal connected to the panel chassis.

1 Mounting screw

50
GP-4402WW/GP-4502WW Hardware Manual

How to Connect the Power Cord


This figure shows a connection of the power cord:

This table explains how to connect the power plug:

Step Action
1 Remove the power cord from the power supply.
2 Remove the power plug from the panel.
3 Remove 7 mm (0.28 in) of the vinyl cover off the ends of the power cord wires.
4 If using stranded wire, twist the ends. Tinning the ends with solder reduces risk of fraying and
ensures good electrical transfer.
5 Connect the wires to the power plug by using a flat-bladed screwdriver (size 0.6 X 3.5).
6 Tighten the mounting screws using the defined torque: 0.5 N·m (4.42 lb-in).
7 Replace the power plug with the power connector.

NOTE:
 Do not solder the wire directly to the power receptacle pin.
 The power supply cord should meet the specification mentioned above. Be sure to twist the
power cords together, up to the power plug, for EMC cancellation.

51
Installation and Wiring

Connecting the Power Supply

Precautions
Excessive stress on the power connection or attempting to install this product with the power
cables connected may disconnect or cause damage to the power connections. This can cause
short circuits, fire or unintended equipment operation.

DANGER
SHORT CIRCUIT, FIRE, OR UNINTENDED EQUIPMENT OPERATION
Avoid excessive force on the power cable to prevent accidental disconnection
 Securely attach power cables to an installation panel or cabinet.
 Use the designated torque to tighten this product's terminal block screws.
 Install and fasten this product on installation panel or cabinet prior to connecting power supply
and communication lines.
Failure to follow these instructions will result in death or serious injury.

Improving Noise/Surge
 This product’s power supply cord should not be bundled with or kept close to main circuit lines
(high voltage, high current), power lines, or input/output lines, and their various systems should
be kept separate. When power lines cannot be wired via a separate system, use shielded cables
for input/output lines.
 Make the power cord as short as possible, and be sure to twist the ends of the wires together
(i.e. twisted pair cabling) from close to the power supply unit.
 If there is an excess amount of noise on the power supply line, reduce the noise with a noise
filter before turning on the power.
 Connect a surge protection device to handle power surges.
 To increase noise resistance, attach a ferrite core to the power cable.

Power Supply Connections


 When supplying power to this product, connect the power as shown below.

 Use SELV (Safety Extra-Low Voltage) circuit and LIM (Limited Energy) circuit for DC input.

52
GP-4402WW/GP-4502WW Hardware Manual

 The following shows a surge protection device connection:

 Attach a surge protection device to prevent damage to this product as a result of a lightning-
induced power surge from a large electromagnetic field generated from a direct lightning strike.
We also strongly recommend to connect the crossover grounding wire of this product to a
position close to the ground terminal of the surge protection device.
It is expected that there will be an effect on this product due to fluctuations in grounding potential
when there is a large surge flow of electrical energy to the lightning rod ground at the time of a
lightning strike. Provide adequate distance between the lightning rod grounding point and the
surge protection device grounding point.
 If the voltage variation is outside the prescribed range, connect a regulated power supply.

1 Regulated power supply


2 Twisted-pair cord
3 This product

53
Installation and Wiring

Grounding

Exclusive Grounding
Always ground the FG (functional ground) terminal. Be sure to separate this product from the FG
of other devices as shown below.

Precautions
 Check that the grounding resistance is 100 Ω or less.*1
 The FG wire should have a cross sectional area greater than 2 mm2 (AWG14)*1. Create the
connection point as close to this product as possible, and make the wire as short as possible.
When using a long grounding wire, replace the thin wire with a thicker wire, and place it in a duct.
*1 Observe local codes and standards.

Common Grounding
Electromagnetic Interference (EMI) can be created if devices are improperly grounded. EMI can
cause loss of communication. If exclusive grounding is not possible, use a common grounding
point as shown in the configuration below. Do not use any other configuration for common
grounding.
Correct grounding

Incorrect grounding

54
GP-4402WW/GP-4502WW Hardware Manual

Section 4.3
USB Port

USB Port

USB Type A Installation

Introduction
When using a USB device, locking the USB interface with the panel helps prevent the USB cable
from being disconnected.
The USB locker does not work with the slim type USB memory stick.

Locking the USB

Step Action
1 Insert the USB cable into the USB host interface:

2 Lock the USB using a screw driver, torque is 0.5...0.8 N•m (4.42...7.07 lb-in):

Releasing the USB


Unlock the USB and then remove the USB memory key.

55
Installation and Wiring

56
GP-4402WW/GP-4502WW Hardware Manual
Maintenance
GP-4402WW4502WW_EN 12/2016

GP-4402WW/GP-4502WW Hardware Manual

Chapter 5
Maintenance

Maintenance

Overview
This chapter explains how to maintain your GP-4402WW/GP-4502WW.

What Is in This Chapter?


This chapter contains the following topics:
Topic Page
Precaution 58
Periodic Check Points 59
Regular Cleaning 60
After-sales Service 61

57
Maintenance

Precaution

Precaution for Long and Safe Use Without Any Breakdowns


Operating the screen with sharp objects may result in damage to the front sheet or
the touch panel, and cause abnormal operation. (A switch in a different location from
the one you touched may be activated.)

Dropping this product or impacting the screen with excessive pressure may result in
breakage of the glass of the touch panel or liquid crystal display. In addition, when
mounting this product with the installation fasteners, applying force exceeding the
appropriate torque specified in the manual may result in breakage of the front panel.
Using HMI in sunlight or ultraviolet light may shorten the lifetime of the touch panel
and may cause the failure of touch functions.

Cleaning the product with chemical agents or allowing penetration of liquids into the
product may cause abnormal operation or breakdowns.

NOTICE
EQUIPMENT DAMAGE
 Power off the unit before cleaning it.
 Do not touch the screen with sharp objects when operating this product.
 Do not touch the screen with excessive pressure when operating this product.
 Avoid using HMI in sunlight or ultraviolet light.
 Avoid using chemical agents or allowing liquids to get into this product.
Failure to follow these instructions can result in equipment damage.

58
GP-4402WW/GP-4502WW Hardware Manual

Periodic Check Points

Operation Environment
 The operating temperature should be within the allowable range (0...50 °C) (32...122 °F).
 The operating humidity should be within the specified range.
 The operating atmosphere should be free of corrosive gases.

Electrical Specifications
The input voltage should be within 20.4 to 28.8 Vdc.

Related Items
 Are all power cords and cables connected properly? Have any become loose?
 Are all mounting brackets holding the unit securely?
 Are there many scratches or traces of dirt on the installation gasket?

NOTICE
EQUIPMENT DAMAGE
 Do not use hard or pointed objects to operate the touch panel.
 Do not apply excessive pressure to the panel.
 Do not expose the panel to direct sunlight/ultraviolet rays.
 Do not use paint thinner, organic solvents, or a strong acid compound to clean the unit.
Failure to follow these instructions can result in equipment damage.

59
Maintenance

Regular Cleaning

Cleaning the Unit

NOTICE
EQUIPMENT DAMAGE
 Power off the unit before cleaning it.
 Do not use hard or pointed objects to operate the touch panel.
 Do not use paint thinner, organic solvents, or a strong acid compound to clean the unit.
Failure to follow these instructions can result in equipment damage.

When the unit gets dirty, soak a soft cloth in water with a neutral detergent, wring the cloth tightly
and wipe the unit.

Replacing the Gasket


The gasket protects the panel and improves its water resistance.
During normal maintenance and reinstallation, check the gasket for dirt and scratches.

NOTICE
GASKET AGING
 Inspect the gasket periodically as required by your operating environment.
 Change the gasket at least once a year, or as soon as scratches or dirt become visible.
Failure to follow these instructions can result in equipment damage.

Insert the gasket correctly into the groove to comply with IP65.

60
GP-4402WW/GP-4502WW Hardware Manual

After-sales Service

Information
For details on after-sales service, refer to our website at
http://www.pro-face.com/trans/in/manual/1015.html

61
Maintenance

62

You might also like