0% found this document useful (0 votes)
416 views

RS-232/485/422 UT-242E Self-Powered Converter User Manual: III. Connector and Signal

UT-242E is a self-powered converter that can convert RS-232 signals to balanced differential RS-422 or RS-485 signals to extend communication distances up to 1.2km without an external power source. It automatically adapts to data stream direction without handshaking signals. It is compatible with RS-232, RS-422, and RS-485 in both half-duplex and full-duplex modes without jumper settings. The converter uses DB-9 and 6-pin connectors and can communicate over STP/UTP cable at rates from 300-115.2kbps, making it suitable for industrial automation and other applications.

Uploaded by

Thắng Trần
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
416 views

RS-232/485/422 UT-242E Self-Powered Converter User Manual: III. Connector and Signal

UT-242E is a self-powered converter that can convert RS-232 signals to balanced differential RS-422 or RS-485 signals to extend communication distances up to 1.2km without an external power source. It automatically adapts to data stream direction without handshaking signals. It is compatible with RS-232, RS-422, and RS-485 in both half-duplex and full-duplex modes without jumper settings. The converter uses DB-9 and 6-pin connectors and can communicate over STP/UTP cable at rates from 300-115.2kbps, making it suitable for industrial automation and other applications.

Uploaded by

Thắng Trần
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

III. Connector and signal .

Communication sketch map


RS-232 pin definition RS-232 to RS-422
Power
DB9 Female positive
(PIN)
RS-232C Interface signal
1 Earth protection 1. RS-422 point to point 4 wires Full-duplex
RS-232/485/422 UT-242E 2 Receive data SIN(RXD)
Power
negative
3 Send data SOUT (TXD)
SELF-POWERED CONVERTER 4 Data terminal ready DTR
1
2
5 Ground signal GND 3
USER MANUAL 6 Data setting ready DSR 4

7 Request send RTS


8 Clear send CTS
I. Summary 9 Ring indication RI
UT-242E RS-422 Machine

RS-485/422 data output & connector and bay-line distribution


Compatible with RS-232C, RS-422 and RS-485, UT-242E self-powered 2. RS-422 point to multipoint 4 wires Full-duplex
PIN Signal Output RS-422 Full-Duplex RS-482 Half-Duplex
converter can convert RS-232 signal into balance differential RS-422 or
1 T/R+ RS-485 (A+)
RS-485 signal and extend the communication distance to 1.2km, no 2 T/R- RS-485 (B-) 1
2
3 RXD+ None 3
external-power needed. Auto-adapt data stream direction without any 4 RXD- None 4

5 GND Ground Wire Ground Wire


handshaking signal (for example RTS, DTR etc). Plug-and-play without
6 VCC None UT-242E RS-422 Machine
any jumper settings needed for RS-422 or RS-485.Baud rate is 300-115.2Kbps.
IV. Hardware installation & application
Suit for industrial automation, all-one-card, door safe, car parking,
The product exterior adopts DB-9 all-purpose transit plugs,
ATM, bus charge, eatery sell out, staff attendance management, and
output plug carries ordinary connection pole, can use TP or
highway's tolling etc. STP and easy connection and disassembly T/R+ T/R- stands for
dispatching A+ B-, VCC stands for standby power input, GND RS-422 Machine
stands for public ground wire point-to-point or point-to-multipoint
II. Performance Full-duplex communication need 2 connection (T/R+ T/R-),
connection principle is T/R+ connects to opposite T/R+ T/R-
1. Interface: RS-232C& RS485/RS-422 EIA/TIA. connects to opposite T/R-, RS-422 Full-duplex mode connection
is to connect T/R+ to opposite A+ and T/R-to opposite B-.
2. DB9 female RS-232 ,6 Pin post for RS-422/RS-485
Remark: A+ for (422+), B- for (422-).
3. Operation mode : asynchronous half duplex or asynchronous RS-422 Machine
UT-242E Using STP/UTP for the installation, 4 working modes
full duplex, without any jumper setting needed.
as below: 3. UT-242E Full-duplex communication connect between
4. Transmission media : STP/UTP interface converter
1. Point-to-point 4-line full duplex
5. Transmission rate : 300-115.2KBPS
2. Point-to-multipoint 4-line full duplex
6. Dimensions: 62mm 40.5mm 21mm. 1 3
3. Point-to-point 2-line half duplex 2 4
7. Working circumstance: -40 to 80 , relative humidity 3 1
4. Point-to-multipoint 2-line half duplex 4 2
5%- 95%.
8. Transmission distance: 1,200m (RS-485 end) 5m(RS-232 end). In order to prevent interference in RS485/422, a 120
UT-242E UT-242E
9. Protection grade: 2000A lighting strike surge protection 1/4W terminal resistor may be used according to particular
situation.

1 2 3
VI. Problem and resolution
RS-232 to RS-485 conversion
1. Communication failure
1.RS-485 point to point 2 wires Full-duplex A. Make sure RS-232 interface connection is correct.
B. Make sure RS-485/RS-422 output interface connection
is correct.
1 C. Make sure the wire terminal connection is OK.
2

2. Data missing or incorrect


A. Check to see whether if the data rate and format at both ends
of the communication equipment are consistent.
UT-242E RS-485 Machine

. Product outline
2. RS-485 point to multipoint 2 wires Full-duplex

1
2

UT-242E RS-485 Machine

62mm

RS-485 Machine

40.5mm
RS-485 Machine

21mm
3. UT-242E Half-duplex communication connect between
interface converter

1 1
2 2

40.5mm
UT-242E UT-242E

4 5