CHARACTERISTICS
General Specifications
Interface 716 DIN Female
Body Style Straight
Brand HELIAX® | Positive Stop™
Mounting Angle Straight
Electrical Specifications
Connector Impedance 50 ohm
Operating Frequency Band 0 – 8800 MHz
Cable Impedance 50 ohm
3rd Order IMD 120 dBm @ 910 MHz
3rd Order IMD Test Method Two +43 dBm Carriers
RF Operating Voltage, maximum (vrms) 1415.00 V
dc Test Voltage 4000 V
Outer Contact Resistance, maximum 1.50 mOhm
Inner Contact Resistance, maximum 0.80 mOhm
Insulation Resistance, minimum 5000 MOhm
Average Power 1.1 kW @ 900 MHz
Peak Power, maximum 40.00 kW
Insertion Loss, typical 0.05 dB
Shielding Effectiveness 110 dB
Outline Drawing
Mechanical Specifications
Outer Contact Attachment Method Ringflare
Inner Contact Attachment Method Captivated
Outer Contact Plating Trimetal
Inner Contact Plating Silver
Attachment Durability 25 cycles
Interface Durability 50 cycles
Interface Durability Method IEC 1694:9.5
Connector Retention Tensile Force 890 N | 200 lbf
Connector Retention Torque 5.42 Nm | 48.00 in lb
Insertion Force 200.17 N | 45.00 lbf
Insertion Force Method IEC 1691:15.2.4
Pressurizable No
Dimensions
Nominal Size 1/2 in
Diameter 29.01 mm | 1.14 in
Length 76.00 mm | 2.99 in
Weight 134.00 g | 0.30 lb
Environmental Specifications
Standard Conditions
Attenuation, Ambient Temperature 20 °C | 68 °F
Average Power, Ambient Temperature 40 °C | 104 °F
Return Loss
Frequency Band VSWR Return Loss (dB)
45–1000 MHz 1.02 39.00
1000–2200 MHz 1.02 39.00
2210–3000 MHz 1.04 34.00
3010–5000 MHz 1.08 28.00
Regulatory Compliance/Certifications
Agency Classification
RoHS 2002/95/EC Compliant by Exemption
China RoHS SJ/T 113642006 Above Maximum Concentration Value (MCV)
* F o o t n o t e s
Immersion Depth Immersion at specified depth for 24 hours
Insertion Loss, typical 0.05√¯freq (GHz) (not applicable for elliptical waveguide)