0% found this document useful (0 votes)
50 views

Ultracore 360 C71: Conformances Key Features

This document provides information on ULTRACORE® 360TM C71 mild steel flux-cored wire, including its key features, conformances, applications, welding positions, diameters, packaging, mechanical properties, deposit composition, typical operating procedures, and other specifications.

Uploaded by

Yousab Creator
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views

Ultracore 360 C71: Conformances Key Features

This document provides information on ULTRACORE® 360TM C71 mild steel flux-cored wire, including its key features, conformances, applications, welding positions, diameters, packaging, mechanical properties, deposit composition, typical operating procedures, and other specifications.

Uploaded by

Yousab Creator
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

FLUX-CORED (FCAW-G) WIRE

ULTRACORE® 360™ C71


Mild Steel, All Position • AWS E71T-1C-JH4, E71T1-C1A2-CS1-H4

KEY FEATURES CONFORMANCES

• Seamless design protects the flux core from environmental AWS A5.20: E71T-1C-JH4
exposure helping to maintain low diffusible hydrogen and AWS A5.36: E71T1-C1A2-CS1-H4
extend shelf life EN ISO 17632-A: T46 3 P C 1 H5
• Copper coating offers superior feedability and extended
contact tip life TYPICAL APPLICATIONS
• Low spatter and fume levels for less post-weld clean up
• Offshore
and a better work environment
• Shipbuilding
• Low H4 diffusible hydrogen levels minimize the risk of
hydrogen induced cracking • Structural
• Premium arc performance and bead appearance • Oil & Gas

WELDING POSITIONS SHIELDING GAS


All 100% CO2
Flow rate: 28-38 CFH

DIAMETERS / PACKAGING
Diameter 33 lb (15 kg)
in (mm) Fiber Spool

0.045 (1.2) W000403771


0.052 (1.3) W000403772
1/16 (1.6) W000403773

MECHANICAL PROPERTIES (1)


Charpy V-Notch
Yield Tensile J (ft•lbf)
Strength(2) Strength Elongation
MPa (ksi) MPa (ksi) % @ -29°C (-20°F) @ -40°C (-40°F)

Requirements
AWS A5.20: E71T-1C-JH4 400 (58) min 490-660 (70-95) 22 min - 27 (20) min
AWS A5.36: E71T1-C1A2-CS1-H4 400 (58) min 490-660 (70-95) 22 min 27 (20) min -
Typical Results (3)

As-Welded with 100% CO2 480-520 (70-76) 560-620 (81-90) 24-28 50-80 (36-59) 30-60 (22-45)

Typical all weld metal. (2)Measured with 0.2% offset. (3)See test results disclaimer
(1)

D-27 | www.lincolnelectric.com
FLUX-CORED (FCAW-G) WIRE

DEPOSIT COMPOSITION(1)

%C %Mn %Si %S
Requirements
AWS A5.20: E71T-1C-JH4 0.12 max 1.75 max 0.90 max 0.03 max
AWS A5.36: E71T1-C1A2-CS1-H4 0.12 max 1.75 max 0.90 max 0.030 max
Typical Results(3)
As-Welded with 100% CO2 0.04-0.07 1.20-1.50 0.30-0.50 < 0.015
Diffusible Hydrogen
%P %Cu %B (mL/100g weld deposit)
Requirements
AWS A5.20: E71T-1C-JH4 0.03 max. 0.35 max. Not Specified 4.0 max.
AWS A5.36: E71T1-C1A2-CS1-H4 0.030 max. 0.35 max. Not Specified 4 max.
Typical Results(3)
As-Welded with 100% CO2 < 0.015 0.10-0.20 0.002-0.006 2-4

TYPICAL OPERATING PROCEDURES


Diameter, Polarity CTWD(5) Wire Feed Speed Voltage Approx. Current Melt-Off Rate Deposition Rate Efficiency
Shielding Gas mm (in) m/min (in/min) (volts) (amps) kg/hr (lb/hr) kg/hr (lb/hr) (%)

6.0 (236) 21-23 160 2.5 (5.5) 2.2 (4.8)


7.5 (295) 23-24 190 3.1 (6.9) 2.7 (6.0)
9.0 (354) 24-26 220 3.8 (8.3) 3.3 (7.3)
0.045 in (1.2 mm), DC+ 15-20
10.5 (413) 26-28 250 4.4 (9.7) 3.9 (8.6) 85-88
100% CO2 (3/4)
11.5 (453) 27-29 260 4.8 (10.6) 4.3 (9.4)
13.0 (512) 28-30 270 5.4 (12.0) 4.8 (10.7)
15.0 (590) 28-31 290 6.3 (13.8) 5.6 (12.3)
5.0 (197) 21-22 210 2.7 (6.1) 2.4 (5.3)
6.0 (236) 23-24 240 3.3 (7.3) 2.9 (6.3)
0.052 in (1.3 mm), DC+ 15-20 8.0 (315) 26-27 280 4.4 (9.7) 3.9 (8.5)
85-88
100% CO2 (3/4) 9.0 (354) 27-29 300 4.9 (10.9) 4.4 (9.7)
10.0 (394) 27-29 320 5.5 (12.1) 4.9 (10.8)
12.5 (492) 29-30 350 6.9 (15.1) 6.1 (13.5)
3.1 (122) 21-22 190 2.4 (5.3) 2.1 (4.6)
5.0 (197) 23-26 280 3.9 (8.6) 3.4 (7.6)
1/16 in (1.6 mm), DC+ 15-20
6.5 (256) 26-28 350 5.1 (11.2) 4.5 (10.0) 85-88
100% CO2 (3/4)
7.5 (295) 27-29 370 5.9 (12.9) 5.2 (11.5)
9.0 (354) 28-30 400 7.0 (15.5) 6.3 (13.8)

Typical all weld metal. (3)See test results disclaimer (4)In order to meet the requirements of the G group, the undiluted weld metal shall have not less than the minimum specified for one or more of the elements listed.
(1)

To estimate ESO, subtract 1/4 in (6.0 mm) from CTWD. NOTE: This product contains micro-alloying elements. Additional information available upon request
(5)

www.lincolnelectric.com | D- 2 8
Material Safety Data Sheets (MSDS) and Certificates of Conformance are available on our website at www.lincolnelectric.com

TE S T R E S U LTS
Test results for mechanical properties, deposit or electrode composition and diffusible hydrogen levels were obtained from a weld produced and tested
according to prescribed standards, and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary
depending on many factors, including, but not limited to, weld procedure, plate chemistry and temperature, weldment design and fabrication methods.
Users are cautioned to confirm by qualification testing, or other appropriate means, the suitability of any welding consumable and procedure before use in
the intended application.

CU S TO M E R AS S I S TA N C E P O L I C Y
The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet
the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of
our products. Our employees respond to inquiries to the best of their ability based on information provided to them by the customers and the knowledge
they may have concerning the application. Our employees, however, are not in a position to verify the information provided or to evaluate the engineering
requirements for the particular weldment. Accordingly, Lincoln Electric does not warrant or guarantee or assume any liability with respect to such information
or advice. Moreover, the provision of such information or advice does not create, expand, or alter any warranty on our products. Any express or implied
warranty that might arise from the information or advice, including any implied warranty of merchantability or any warranty of fitness for any customers’
particular purpose is specifically disclaimed.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains
the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of
fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any
updated information.

THE LINCOLN ELECTRIC COMPANY


22801 St. Clair Avenue • Cleveland, OH • 44117-1199 • U.S.A.
Phone: +1.216.481.8100 • www.lincolnelectric.com

Publication C3.12.50 | Issue Date 12/18