Ultrafast Soft Recovery Rectifier Diode: Dual Die Isotop Package

The document provides specifications for ultrafast soft recovery rectifier diodes with part numbers APT2X60D100J and APT2X61D100J. It lists maximum ratings, static and dynamic electrical characteristics, and thermal and mechanical characteristics. Key features include ultrafast recovery times, soft recovery, low forward voltage, and high blocking voltage.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views4 pages

Ultrafast Soft Recovery Rectifier Diode: Dual Die Isotop Package

The document provides specifications for ultrafast soft recovery rectifier diodes with part numbers APT2X60D100J and APT2X61D100J. It lists maximum ratings, static and dynamic electrical characteristics, and thermal and mechanical characteristics. Key features include ultrafast recovery times, soft recovery, low forward voltage, and high blocking voltage.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

2 3 2 3

2 3

7
22
1 4 1 4
1 4
TO - ®
Anti-Parallel Parallel S
APT2X60D100J APT2X61D100J
"UL Recognized" APT2X61D100J 1000V 55A
ISOTOP ®
APT2X60D100J 1000V 55A

DUAL DIE ISOTOP® PACKAGE


ULTRAFAST SOFT RECOVERY RECTIFIER DIODE
PRODUCT APPLICATIONS PRODUCT FEATURES PRODUCT BENEFITS
• Anti-Parallel Diode • Ultrafast Recovery Times • Low Losses
-Switchmode Power Supply
-Inverters • Soft Recovery Characteristics • Low Noise Switching
• Free Wheeling Diode
-Motor Controllers • Popular SOT-227 Package • Cooler Operation
-Converters
• Snubber Diode • Low Forward Voltage • Higher Reliability Systems
• Uninterruptible Power Supply (UPS)
• Induction Heating • High Blocking Voltage • Increased System Power
• High Speed Rectifiers Density
• Low Leakage Current

MAXIMUM RATINGS All Ratings: TC = 25°C unless otherwise specified.

Symbol Characteristic / Test Conditions APT2X61_60D100J UNIT

VR Maximum D.C. Reverse Voltage

VRRM Maximum Peak Repetitive Reverse Voltage 1000 Volts

VRWM Maximum Working Peak Reverse Voltage

IF(AV) Maximum Average Forward Current (TC = 95°C, Duty Cycle = 0.5) 55
IF(AV) RMS Forward Current (Square wave, 50% duty) 75 Amps

IFSM Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms) 540


TJ,TSTG Operating and StorageTemperature Range -55 to 175
°C
TL Lead Temperature for 10 Sec. 300

STATIC ELECTRICAL CHARACTERISTICS


Symbol Characteristic / Test Conditions MIN TYP MAX UNIT

IF = 60A 1.9 2.5


VF Forward Voltage IF = 120A 2.2 Volts

IF = 60A, TJ = 125°C 1.7


VR = VR Rated 250
3-2005

IRM Maximum Reverse Leakage Current µA


VR = VR Rated, TJ = 125°C 500
053-0005 Rev F

CT Junction Capacitance, VR = 200V 65 pF

APT Website - http://www.advancedpower.com


DYNAMIC CHARACTERISTICS APT2X61_60D100J

Symbol Characteristic Test Conditions MIN TYP MAX UNIT


trr Reverse Recovery Time IF = 1A, diF/dt = -100A/µs, VR = 30V, TJ = 25°C - 34
ns
trr Reverse Recovery Time - 280
Qrr IF = 60A, diF/dt = -200A/µs
Reverse Recovery Charge - 760 nC
VR = 667V, TC = 25°C
IRRM Maximum Reverse Recovery Current - 6 - Amps
trr Reverse Recovery Time - 350 ns
Qrr IF = 60A, diF/dt = -200A/µs
Reverse Recovery Charge - 3600 nC
VR = 667V, TC = 125°C
IRRM Maximum Reverse Recovery Current - 16 - Amps
trr Reverse Recovery Time - 170 ns
IF = 60A, diF/dt = -1000A/µs
Qrr Reverse Recovery Charge - 5650 nC
VR = 667V, TC = 125°C
IRRM Maximum Reverse Recovery Current - 50 Amps

THERMAL AND MECHANICAL CHARACTERISTICS


Symbol Characteristic / Test Conditions MIN TYP MAX UNIT

RθJC Junction-to-Case Thermal Resistance .56


°C/W
RθJA Junction-to-Ambient Thermal Resistance 20
1.03 oz
WT Package Weight
29.2 g

10 lb•in
Torque Maximum Mounting Torque
1.1 N•m
APT Reserves the right to change, without notice, the specifications and information contained herein.

0.60
Z JC, THERMAL IMPEDANCE (°C/W)

0.9
0.50

0.40 0.7

0.30 0.5
Note:
PDM

t1
0.20
0.3
t2

0.10 t
0.1 Duty Factor D = 1/t2
θ

SINGLE PULSE Peak TJ = PDM x ZθJC + TC


0.05
0
10-5 10-4 10-3 10-2 10-1 1.0
RECTANGULAR PULSE DURATION (seconds)
FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION
RC MODEL
Junction
temp (°C)

0.148 °C/W 0.00600 J/°C


3-2005

Power
0.238 °C/W 0.0909 J/°C
(watts)
053-0005 Rev F

0.174 °C/W 0.524 J/°C

Case temperature (°C)

FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL


TYPICAL PERFORMANCE CURVES APT2X61_60D100J
200 500
T = 125°C
J
180 V = 667V
R
120A

trr, REVERSE RECOVERY TIME


IF, FORWARD CURRENT 160 400

140
60A
120 300
TJ = 150°C

(ns)
(A)

100 30A
80 200
TJ = 125°C TJ = 25°C
60

40 100
TJ = -55°C
20
0 0
0 0.5 1 1.5 2 2.5 3 0 200 400 600 800 1000 1200
VF, ANODE-TO-CATHODE VOLTAGE (V) -diF /dt, CURRENT RATE OF CHANGE(A/µs)
Figure 2. Forward Current vs. Forward Voltage Figure 3. Reverse Recovery Time vs. Current Rate of Change
8000 60

IRRM, REVERSE RECOVERY CURRENT


T = 125°C T = 125°C
J J
Qrr, REVERSE RECOVERY CHARGE

V = 667V
R
V = 667V
R
120A
7000
120A 50
6000
40
5000
60A
(nC)

(A)
60A
4000 30

3000
30A 20
2000 30A

10
1000

0 0
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200
-diF /dt, CURRENT RATE OF CHANGE (A/µs) -diF /dt, CURRENT RATE OF CHANGE (A/µs)
Figure 4. Reverse Recovery Charge vs. Current Rate of Change Figure 5. Reverse Recovery Current vs. Current Rate of Change
1.4 90
Duty cycle = 0.5
T = 175°C
trr 80 J
1.2
Kf, DYNAMIC PARAMETERS

Qrr
(Normalized to 1000A/µs)

70
1.0
60
IRRM
IF(AV) (A)

0.8 50

0.6 t 40
rr
Qrr
30
0.4
20
0.2
10

0.0 0
0 25 50 75 100 125 150 75 100 25125 50
150 175
TJ, JUNCTION TEMPERATURE (°C) Case Temperature (°C)
Figure 6. Dynamic Parameters vs. Junction Temperature Figure 7. Maximum Average Forward Current vs. CaseTemperature
600
CJ, JUNCTION CAPACITANCE

500

400
(pF)

300
3-2005

200

100
053-0005 Rev F

0
1 10 100 200
VR, REVERSE VOLTAGE (V)
Figure 8. Junction Capacitance vs. Reverse Voltage
APT2X61_60D100J
Vr

+18V diF /dt Adjust


APT10035LLL

0V
D.U.T.
30µH trr/Qrr
Waveform

PEARSON 2878
CURRENT
TRANSFORMER

Figure 9. Diode Test Circuit

1 IF - Forward Conduction Current


1 4
2 diF /dt - Rate of Diode Current Change Through Zero Crossing.
Zero
3 IRRM - Maximum Reverse Recovery Current.
5 0.25 IRRM
4 trr - Reverse Recovery Time, measured from zero crossing where diode 3
current goes from positive to negative, to the point at which the straight 2
line through IRRM and 0.25 IRRM passes through zero.

5 Qrr - Area Under the Curve Defined by IRRM and trr.

Figure 10, Diode Reverse Recovery Waveform and Definitions

SOT-227 (ISOTOP®) Package Outline


11.8 (.463)
31.5 (1.240) 12.2 (.480)
31.7 (1.248) 8.9 (.350)
7.8 (.307) W=4.1 (.161) 9.6 (.378)
8.2 (.322) W=4.3 (.169) Hex Nut M4 H100
H=4.8 (.187) (4 places)
H=4.9 (.193)
(4 places)

25.2 (0.992)
r = 4.0 (.157)
(2 places) 4.0 (.157) 0.75 (.030) 12.6 (.496) 25.4 (1.000)
4.2 (.165) 0.85 (.033) 12.8 (.504)
(2 places)

3.3 (.129) 1.95 (.077)


3.6 (.143) 2.14 (.084)
14.9 (.587) Anti-parallel Parallel
15.1 (.594)
3-2005

APT2X60D100J APT2X61D100J
30.1 (1.185)
30.3 (1.193) Anode 2 Cathode 1 Cathode 1 Anode 1
38.0 (1.496)
38.2 (1.504)
053-0005 Rev F

Dimensions in Millimeters and (Inches) Cathode 2 Anode 1 Cathode 2 Anode 2

ISOTOP® is a Registered Trademark of SGS Thomson.


,