F1 (5'-0" X 5'-0") F1 (5'-0" X 5'-0") F2 (5'-9" X 6'-9") : Column Layout Plan (Above PL)
F1 (5'-0" X 5'-0") F1 (5'-0" X 5'-0") F2 (5'-9" X 6'-9") : Column Layout Plan (Above PL)
PL (1'-6")
SCHEDULE OF FOOTING
Column
FOOTING SIZE THICKNESS REINFORCEMENT
1'-6"
E.G.L. (±0'-0") FOOTING INDEX
LONG DIRECTION SHORT DIRECTION
L S T1 T2
(Asl) (Ass)
9"
F2 5'-9" 6'-9" 14" 9" Ø 16 mm @ 5" c/c Ø 16 mm @ 5" c/c
GB (12"x18")
F3 7'-9" 7'-9" 16" 9" Ø 16 mm @ 5" c/c Ø 16 mm @ 5" c/c
212" clear cover
8'-0"
T1 T1
T
2" Clear cover
T
3" C.C. with brick chips Ass Asl
3"
(nominal mix proportion 1:3:6)
SEC: ON A-A
Ass
Asl
A A
L (Short)
S (Long)
38'-0"
3'-0"
5'-0"
5'-9"
5'-0"
F1 (5'-0" x 5'-0" ) F1 (5'-0" x 5'-0" )
F2 (5'-9" x 6'-9" )
18'-0"
F3 (7'-9" x 7'-9" )
F2 (5'-9" x 6'-9" ) 7'-9" F2 (5'-9" x 6'-9" )
5'-9" 5'-9"
6'-9"
6'-9"
7'-9"
22'-112"
78'-0"
1'-1012"
3'-412"
CF-1 CF-1
CF-1
9'-9"
1'-1012"
3'-412"
3'-9"
6'-9"
22'-112"
5'-0"
F1 (5'-0" x 5'-0" )
5'-0"
6'-9"
5'-0"
5'-0"
F1 (5'-0" x 5'-0" )
5'-9"
5'-0"
3'-0"
15'-0"
8'-0"
Road