Cp44-Mec+ Cp16-Lcd+ CP-MDP-BW+ CP-MDP-CL+: Vikinx Ip-Based Control Panels For Multicon
Cp44-Mec+ Cp16-Lcd+ CP-MDP-BW+ CP-MDP-CL+: Vikinx Ip-Based Control Panels For Multicon
CP16-LCD+
CP-MDP-BW+
CP-MDP-CL+
User manual
Rev. P
Nevion
Nordre Kullerød 1
3241 Sandefjord
Norway
Tel: +47 33 48 99 99
nevion.com
IP Based Control Panels Rev. P
Nevion Support
Nevion Europe Nevion USA
E-mail: [email protected]
See http://www.nevion.com/support/ for service hours for customer support globally.
Revision history
Current revision of this document is the uppermost in the table below.
Rev. Repl. Date Sign Change description
Cover page update; DoC removed; no other
P 13 2015-05-11 MB
changes to content
13 12 2012-04-19 JGS Removed EPC information
12 11 2009-08-17 JIH Updated for Multicon
11 10 2008-10-10 NBS New format, updated illustrations, etc.
10 9 2007-10-23 New front page.
Added Materials Declaration and EFUP; updated EC
9 8 2007-03-30
Declaration of Conformity.
8 7 08/05/06 Added Software note at the end of this document.
7 6 16/11/04 Added information about GPI pinout. (Chapter 3.5).
Redesigned document, added Control Panel
6 5 29/06/04
Configurator features
5 4 26/03/04 Added warranty description.
4 3 19/02/04 Corrected DIP information table.
3 2 06/01/04 Updated DIP information.
2 1 19/12/03 Added more configuration options.
1 0 05/12/03 Updated with more programming facilities.
0 - 25/11/03 Initial Revision
nevion.com | 2
IP Based Control Panels Rev. P
Contents
Revision history ..................................................................................................................... 2
Definitions, Acronyms and Abbreviations............................................................................... 4
1 Product overview ................................................................................................................ 5
1.1 Control Panel Features .................................................................................................... 5
2 Specifications ..................................................................................................................... 7
2.1 Front view ........................................................................................................................ 7
2.2 Rear view ........................................................................................................................ 7
2.3 Power connection ............................................................................................................ 8
3 Configuration ...................................................................................................................... 9
3.1 Router Control Interface .................................................................................................. 9
3.2 Ethernet setup ................................................................................................................11
3.3 Panel Group Setup .........................................................................................................12
3.4 DIP switches on the panel ..............................................................................................12
3.4.1 Upper DIP switch block (SW1).....................................................................................13
3.4.2 Lower DIP switch block (SW2).....................................................................................13
3.5 LED Status .....................................................................................................................13
4 Connections ......................................................................................................................14
4.1 GPI I/O connections .......................................................................................................14
5 Troubleshooting.................................................................................................................15
5.1 Checklist.........................................................................................................................15
General environmental requirements for Nevion equipment .................................................16
Important notes regarding Software in the VikinX Modular router family range .....................17
Product Warranty .................................................................................................................18
Appendix A Materials declaration and recycling information .................................................19
A.1 Materials declaration ......................................................................................................19
A.2 Recycling information .....................................................................................................19
nevion.com | 3
IP Based Control Panels Rev. P
nevion.com | 4
IP Based Control Panels Rev. P
1 Product overview
Important firmware notice:
CP-44MEC+, CP-16LCD+, CP-MDP-BW+ and CP-MDP-CL+ products comes
pre-installed with firmware (version 2.X) for Multicon and cannot be used with
legacy ETH-CON and Syscon products. It is possible to downgrade these
products with firmware (version 1.X) for use with ETH-CON and Syscon.
CP-44MEC, CP-16LCD, CP-MDP-BW and CP-MDP-CL products comes pre-
installed with firmware (version 1.X) for use with ETH-CON and Syscon. It is
possible to upgrade these products with firmware (version 2.X) for Multicon.
Nevion’s IP-based Control Panel series includes advanced programmable control panels, for
control of Nevion VikinX routers and Flashlink cards. The Multicon controller also gives you
possibility to control 3rd party router systems from these panels. All buttons on the control
panels are configurable. The configuration is done from a Windows computer with Nevion
Configurator installed.
The IP-based Control Panel series includes three different panel types: CP-44MEC+, CP-
16LCD+ and CP-MDP+. In addition, CP-44MEC+ and CP-16LCD+ may be combined to form
larger control panels, by using the Expandable Panel Concept (EPC).
The CP-44MEC+ is a 1RU programmable control panel, offering 44 buttons, with tri-color
illumination and 16 GPI (I/O). The panel communicates with the router via TCP/IP panel
bus.
The CP-16LCD+ is a 1RU programmable control panel, offering 16 LCD buttons, with tri-
color illumination and 16 GPI (I/O). The panel communicates with the router via TCP/IP
panel bus.
The CP-MDP+ is a 2RU programmable control panel, offering 64 buttons, with tri-color
illumination and 16 GPI (I/O). The panel communicates with the router via TCP/IP panel
bus. Further, the panel offers a 320x240 QVGA display, either color or B/W.
nevion.com | 5
IP Based Control Panels Rev. P
A button can be configured to be a GPI Output trigger. A GPI Input can also trigger a switch
command, or a salvo.
Layout features
Support features like button copy, button move and clear button function.
Special Functions
Take
Panel Enable
Audio/Video Toggle
X-point Lock/Unlock
Additional special functions available on CP-44MEC:
Take On/Off
Additional special functions available on CP-16LCD:
Take On/Off
Additional special functions available on CP-MDP:
Source or Destination mode selection
Scroll Up/Down
Clear Preset
Previous Source
Menu functions (Display, Enter, Up, Down, Clear)
Numeric Keypad (0 – 9) and numeric backspace
nevion.com | 6
IP Based Control Panels Rev. P
2 Specifications
2.1 Front view
Note that in Figure 4 and Figure 5 the two Status LEDs are not shown on the
drawings.
nevion.com | 7
IP Based Control Panels Rev. P
Connect the DB9 female connector from the desktop power supply to the main unit. Tighten
the screws to assure a proper contact. To connect mains to the desktop power supply you
need a mains cord with IEC 320 connector.
The VikinX IP-based Control Panels are normally delivered with the desktop power model
AC ±5V/35W. Upon customer request the panels can also be delivered with DC ±5V/30W,
which may be fed by a 36 – 72 VDC mains power source. A Frame mounted power supply
solution is also available.
Please refer to the latest VikinX Product Catalogue for power supply types, or call Nevion for
this information.
Current draw by the panels, without any load on the GPI output:
CP-44MEC +5V / 1.2A
CP-16LCD +5V / 1.1A
CP-MDP +5V / 1.7A
nevion.com | 8
IP Based Control Panels Rev. P
3 Configuration
Use the accompanying software package; Nevion Configurator when configuring
communications setting, button functions, etc.
Each subnet, or site, must have a PC with Nevion Configurator installed, in order
to configure your systems.
When this software package has been installed on your PC, just start the program identified
by the icon;
Note that Nevion Configurator has to run with Administrator rights on Windows
Vista operating systems.
Follow the instructions documented in the User Manual for Nevion Configurator in order to
configure your CP-44MEC+, CP-16LCD+ and/or CP-MDP+.
Please read the chapters hereunder, as the information provided forms a useful background
before configuring your system.
nevion.com | 9
IP Based Control Panels Rev. P
Note that the NCB must be either looped, or as in the figure above, terminated at
both ends.
nevion.com | 10
IP Based Control Panels Rev. P
Ethernet setup must be done with the Nevion Configurator software package,
which is supplied together with any of the CPs or routers.
If using managed Ethernet switch; set all ports to panels and routers to auto
negotiation.
nevion.com | 11
IP Based Control Panels Rev. P
The figure below shows both types of dipswitch blocks that may be used on this panel.
nevion.com | 12
IP Based Control Panels Rev. P
The figure above may not show the dipswitches in their default position.
nevion.com | 13
IP Based Control Panels Rev. P
4 Connections
4.1 GPI I/O connections
GPI I/O connector type is DB25 female.
In-/Output # DB25 Pin #
1 12
2 24
3 23
4 10
5 9
6 21
7 20
8 7
9 6
10 18
11 17
12 4
13 3
14 15
15 14
16 1
All GPI inputs are internally connected to +5V via a pull-up resistor. The inputs will be
activated when pulling them to Ground (GND).
GND (on both in-/output connector) is available on the following pins: 2, 5, 8, 11, 13, 16, 19,
22, and 25 and on the connector chassis.
The GPI outputs are of open collector type. An output can switch a maximum load of 100mA
at 30V. Any device to be controlled by the GPI outputs (lamp, LED or similar) needs to be
connected to an external supply voltage on one end and to the GPI output on the other end.
Warning! Do not connect external supply voltages higher than 30V DC.
nevion.com | 14
IP Based Control Panels Rev. P
5 Troubleshooting
Please read this chapter before calling Nevion Support.
5.1 Checklist
Question Actions to follow
Is the latest Nevion Configurator Check the website:
installed? http://www.nevion.com/support/
Has the System Controller the latest Check the website:
firmware (Multicon)? http://www.nevion.com/support/
Are System Controller, Control Panels Check your switch / hub
and computer connected to the same
LAN?
Are System Controller, Control Panels Check the IP settings (using System
and computer in the same IP range? Configurator).
Are System Controller, Control Panels Check the IP settings (using System
and computer in the same subnet Configurator).
mask?
Are System Controller, Control Panels Check the IP settings (using System
and computer in the same Default Configurator).
Gateway?
Does the control panel have the correct Check the IP settings (using System
system controller IP address set in the Configurator).
configuration view?
nevion.com | 15
IP Based Control Panels Rev. P
2. The equipment will operate without damage under the following environmental
conditions:
- Temperature range: -10°C to 50°C
- Relative humidity range: <95% (non-condensing)
nevion.com | 16
IP Based Control Panels Rev. P
This product utilizes software components that are licensed with open source licenses. The
source code for these components and our modifications are available from:
http://labs.nevion.com/open-source/
You may also send Nevion a recordable CD and a self-addressed envelope, and we will burn
the contents of http://labs.nevion.com/open-source/ to your CD and send it back to you.
nevion.com | 17
IP Based Control Panels Rev. P
Product Warranty
The warranty terms and conditions for the product(s) covered by this manual follow the
General Sales Conditions by Nevion, which are available on the company web site:
www.nevion.com
nevion.com | 18
IP Based Control Panels Rev. P
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous
materials used for this part is above the limit requirement in SJ/T11363-2006.
nevion.com | 19